Case Report
QUICK LINKS
Volume 6, Number 1-2, June 2017, pages 14-17 Instructions to Authors
Submit Manuscript
Editorial Board
Publication Ethics
Do Sterilization Processes Really Make Difference in Dialysis-Induced Human & Animal Rights
Genotoxicity? Informed Consent
Conflict of Interest
a, c a a a, b a, b a a
Emna El Golli-Bennour , Chiraz Zaied , Chayma Bouaziz , Yosra Guedri , Abdellatif Achour , Salwa Abid , Hassen Bacha Copyright and Permission
a Journal Contact
Laboratory for Research on Biologically Compatible Compounds, Faculty of Dentistry, Monastir, Tunisia
b Publishing Charge
Nephrology Department, CHU, Sousse, Tunisia
c
Corresponding Author: Emna El Golli-Bennour, Laboratory for Research on Biologically Compatible Compounds, Faculty of Dentistry,
Monastir, Tunisia
Manuscript accepted for publication December 14, 2016
Short title: Sterilization in Dialysis-Induced Genotoxicity
doi: https://doi.org/10.14740/wjnu296e
Abstract
Introduction
Case Report
Discussion
References
Abstract ▴Top
The major problem associated with hemodialysis (HD) therapy is the choice of dialyzer membrane matters as
well as the mode of sterilization required before utilization. In this context, we aimed to determine the effect of
two sterilization processes (steam and gamma rays) on genotoxicity of polysulfone dialysis membranes. A 38-
year-old man with end-stage renal disease and one age-matched healthy subject were enrolled in our study.
We analyzed lipid peroxidation measured by serum malondialdehyde (MDA) formation and DNA fragmentation
assessed by agarose gel electrophoresis and diphenylamine quantification. Our results clearly showed that
there is a rising generation of MDA and DNA fragmentation in patient sera during HD session when compared COVID-19 RESEARCH
to healthy subject data. This increase in MDA and DNA fragmentation amounts followed respectively the
The COVID-19 outbreak
sterilization process. As classified from the more biocompatible one, the steam sterilized polysulfone dialyzer is presents the unprecedented
the top ranked, followed by the gamma rays sterilized one. We concluded that using steam instead of gamma challenge for world public and
medical practitioners and
rays for sterilization may improve the biocompatibility of polysulfone dialyzer membranes.
health care providers, the post
COVID-19 condition (or long
Keywords: Dialyzer membranes; Sterilization process; Oxidative stress; Genotoxicity
COVID) includes long term
symptoms which may persist
for months or years after
Introduction ▴Top SARS-CoV-2 infection. We will
consider submissions related
to all aspects of COVID-19 and
Hemodialysis (HD) is the routine treatment for chronic renal failure [1, 2]. The major problem associated with Long COVID, and process the
this therapy is the bioincompatibility of dialyzer membranes [3]. Several polymeric membranes have been used manuscripts in priority.
as materials for HD and these require sterilization processes before utilization. The methods currently used for
sterilization of dialyzers include treatment with ethylene oxide and gamma irradiation. Meanwhile, alternative Collection of COVID-19 Articles
sterilization modes such as steam sterilization have been suggested [4, 5]. In this study, we tried to check if
the sterilization process really makes any difference in dialysis-induced genotoxicity.
Case Report ▴Top
Subjects
This study involved one HD patient (man, aged 38 years) with end-stage renal disease, who had undergone
chronic HD treatment for 4 h, three times a week for 6 years. The patient has given his informed consent. For
this study, before sample collecting, the patient underwent dialysis with every membrane type for at least 3
months. Results were then compared with those from one age-matched healthy subject from the general
population.
Samples
Blood venous samples (5 mL) were drawn from HD patient at the beginning (T0), the middle; after 2 h (T2)
and the end; after 4 h (T4) of HD session and were placed in heparinized tubes. Serum was obtained by
centrifugation at 1,500 × g for 10 min at 4 °C.
Dialyzer membranes
Dialyzer membranes include: 1) F6-HPS: polysulfone dialyzer, surface area 1.3 m2 sterilized by steam (M1)
and from Fresenius Medical Care AG, Bad Homburg, Germany. 2) APS 650: polysulfone dialyzer, surface area
1.3 m2 sterilized by gamma rays (M2) and from Asahi Kasei Medical, Tokyo, Japan.
All dialyzers are high-flux dialyzers.
Methods
Lipid peroxidation measurement
Lipid peroxidation was carried out by the measurement of malondialdehyde (MDA) according to the method of
Ohkawa et al (1979) [6]. Serum (100 µL) was combined with 0.2 mL of 8.1% SDS, 1.5 mL of 20% acetic acid
adjusted to 3.5 of pH and 1.5 mL of 0.8% thiobarbituric acid. The mixture was brought to a final volume of 4
mL with distilled water and heated at 95 °C for 2 h. After being cooled at room temperature, 5 mL of n-butanol
and pyridine mixture (15:1, v/v) was added to each sample and the whole was shaken vigorously. After
centrifugation at 15,000 rpm for 10 min, the supernatant fraction was isolated and the absorbance was
measured at 532 nm. The concentration of MDA was determined according to a standard curve.
DNA extraction and quantification
DNA was extracted from peripheral blood leucocytes using blood DNA purification kit (Promega) and was
quantified by UV spectrophotometry at 260 nm.
DNA fragmentation by agarose gel electrophoresis
Loading buffer (0.25% bromophenol blue and 40% saccharose) was added to 5 µg of DNA for each sample.
Samples were then analyzed by electrophoresis on a 1% agarose gel (1 h at 80 V/30 mA) with a Tris-Borate-
EDTA running buffer (44 mM Tris-HCl, 44 mM boric acid, 50 mM EDTA, pH 8.0), stained with ethidium bromide
and photographed with a SynGene GeneStore system.
DNA quantification by diphenylamine
DNA fragmentation was measured according to the method described by Sandau et al (1997) [7].
Diphenylamine solution (320 µL) (in 10 mL glacial acetic acid: 150 mg diphenylamine, 150 mL H2SO4 and 50
mL acetaldehyde 16 mg/mL) was added to each sample tube containing 5 µg of DNA, followed by incubation
overnight at room temperature. The optical density was determined at 600 nm. DNA fragmentation was
calculated as follows: % fragmented DNA = (OD supernatant/OD supernatant + OD pellet) × 100.
Discussion ▴Top
In the uremic state, many factors could be involved in DNA damage, in particular an enhanced generation of
oxidative stress [8, 9]. The increased DNA damage in cells of patients with chronic renal insufficiency and long-
term HD therapy may be causally linked to the high cancer incidence, in particular, cancer of the kidney,
prostate, liver, and uterus, compared with the general population [10, 11]. In the present study, we have
demonstrated that the sterilization processes of dialyzer membranes can interfere with the oxidative and
genotoxic status of HD patient. As compared to healthy subject, there was a rising generation of MDA in
patient blood during HD session. Nevertheless, this MDA production differs with the sterilization process.
Indeed, at the end of HD session (T4), the serum MDA amounts were about 5 and 15 folds respectively for
steam sterilized M1 and gamma rays sterilized M2 as compared to the MDA amount in control (Fig. 1).
Consequently, utilization of radiation as sterilization process induced more ROS than the steam procedure.
Even so, the steam method for sterilization is still the most biocompatible one. In fact, we have previously
shown that steam-sterilized membranes improve endothelial cell viability and limit lipid peroxidation
enhancement when compared to ethylene oxide or gamma rays-sterilized ones [12].
Figure 1. Lipid peroxidation levels in patient and
healthy subject sera measured by production of
malondialdehyde (MDA), at the beginning (T0), the
middle (after 2 h, T2) and the end (after 4 h, T4) of
HD session and using different dialyzer sterilization
processes: M1 (sterilized by steam) and M2
Click for large image
(sterilized by gamma rays). MDA amounts (µg/mL)
were determined according to a standard curve.
Results were expressed as mean ± SD from three
independent experiments.
Slight DNA fragmentation was observed with dialyzer sterilized by steam (M1). The DNA fragmentation profile
was more pronounced with dialyzer sterilized by gamma rays (M2). DNA fragments (DNA ladders) showing
varying sizes between 750 and 2,000 base pairs were clearly visible after agarose gel electrophoresis, but no
specific DNA fragments were detected when controls were analyzed (Fig. 2). Using a quantitative analysis of
DNA fragmentation, a significant effect was observed after peripheral blood leucocytes exposure to different
sterilized dialyzer membranes. This DNA fragmented level reached at the end of HD session 19±0.624% and
28±0.975%, respectively for steam sterilized M1 and gamma rays-sterilized M2 (Fig. 3). However, these
genotoxic effects should be consequences of oxidative injury. Our finding is in concordance with other data that
report a significant DNA fragmentation level in HD patient lymphocytes [13, 14].
Figure 2. DNA fragmentation induced by exposure
to different dialyzer membranes sterilization mode:
M1 (sterilized by steam) and M2 (sterilized by
Click for large image gamma rays), in patient leucocytes at the end (after
4 h, T4) of HD session and revealed by agarose gel
electrophoresis.
Figure 3. Percentage of DNA fragmentation caused
by exposure to different dialyzer membranes
sterilization mode: M1 (sterilized by steam) and M2
(sterilized by gamma rays), in patient leucocytes at
the beginning (T0), the middle (after 2 h, T2) and
the end (after 4 h, T4) of HD session and
Click for large image
determined using the diphenylamine assay. Results
were expressed as mean ± SD from three
independent experiments.
Finally, steam sterilization of dialyzers offers considerable safety advantages to the patient and is preferred to
other sterilization modes, such as gamma irradiation.
Acknowledgments
This research was supported by Le Ministere Tunisien de l’Enseignement Superieur, de la Recherche
Scientifique et de la Technologie, through the Laboratoire de Recherche sur les Substances Biologiquement
Compatible.
References ▴Top
1. Iseki K, Tozawa M, Takishita S. Determinants of prescribed dialysis dose and survival in a cohort of
chronic hemodialysis patients. Clin Exp Nephrol. 2003;7(3):231-237.
doi pubmed
2. Chan R, Brooks R, Erlich J, Chow J, Suranyi M. The effects of kidney-disease-related loss on long-term
dialysis patients' depression and quality of life: positive affect as a mediator. Clin J Am Soc Nephrol.
2009;4(1):160-167.
doi pubmed
3. Hoenich NA. Membranes for dialysis: can we do without them? Int J Artif Organs. 2007;30(11):964-970.
pubmed
4. Muller TF, Seitz M, Eckle I, Lange H, Kolb G. Biocompatibility differences with respect to the dialyzer
sterilization method. Nephron. 1998;78(2):139-142.
doi pubmed
5. Aucella F, Tetta C, Tessore V, De Nitti C, Vigilante M, Gatta G, Grandone E, et al. Is steam sterilization
really making any difference in dialysis-induced cytokine release? Int J Artif Organs. 2002;25(9):832-
837.
pubmed
6. Ohkawa H, Ohishi N, Yagi K. Assay for lipid peroxides in animal tissues by thiobarbituric acid reaction.
Anal Biochem. 1979;95(2):351-358.
doi
7. Sandau K, Pfeilschifter J, Brune B. Nitric oxide and superoxide induced p53 and Bax accumulation during
mesangial cell apoptosis. Kidney Int. 1997;52(2):378-386.
doi pubmed
8. Inagi R, Miyata T. Oxidative protein damage with carbohydrates and lipids in uremia: 'Carbonyl stress'.
Blood Purif. 1999;17(2-3):95-98.
doi pubmed
9. Himmelfarb J, Stenvinkel P, Ikizler TA, Hakim RM. The elephant in uremia: oxidant stress as a unifying
concept of cardiovascular disease in uremia. Kidney Int. 2002;62(5):1524-1538.
doi pubmed
10. Matas AJ, Simmons RL, Kjellstrand CM, Buselmeier TJ, Najarian JS. Increased incidence of malignancy
during chronic renal failure. Lancet. 1975;1(7912):883-886.
doi
11. Iseki K, Osawa A, Fukiyama K. Evidence for increased cancer deaths in chronic dialysis patients. Am J
Kidney Dis. 1993;22(2):308-313.
doi
12. Golli-Bennour EE, Kouidhi B, Dey M, Younes R, Bouaziz C, Zaied C, Bacha H, et al. Cytotoxic effects
exerted by polyarylsulfone dialyser membranes depend on different sterilization processes. Int Urol
Nephrol. 2011;43(2):483-490.
doi pubmed
13. Horoz M, Bolukbas C, Bolukbas FF, Kocyigit A, Aslan M, Koylu AO, Gumus M, et al. Assessment of
peripheral DNA damage by alkaline comet assay in maintenance hemodialysis subjects with hepatitis C
infection. Mutat Res. 2006;596(1-2):137-142.
doi pubmed
14. Bagatini PB, Palazzo RP, Rodrigues MT, Costa CH, Maluf SW. Induction and removal of DNA damage in
blood leukocytes of patients with type 2 diabetes mellitus undergoing hemodialysis. Mutat Res.
2008;657(2):111-115.
doi pubmed
This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits
unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
World Journal of Nephrology and Urology is published by Elmer Press Inc.
Browse Journals
Journal of Clinical Medicine Research Journal of Endocrinology and Metabolism Journal of Clinical Gynecology and Obstetrics
World Journal of Oncology Gastroenterology Research Journal of Hematology
Journal of Medical Cases Journal of Current Surgery Clinical Infection and Immunity
Cardiology Research World Journal of Nephrology and Urology Cellular and Molecular Medicine Research
Journal of Neurology Research International Journal of Clinical Pediatrics
World Journal of Nephrology & Urology, quarterly, ISSN 1927-1239 (print), 1927-1247 (online), published by Elmer Press Inc.
The content of this site is intended for health care professionals.
This is an open-access journal distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted
non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Creative Commons Attribution license (Attribution-NonCommercial 4.0 International CC-BY-NC 4.0)
This journal follows the International Committee of Medical Journal Editors (ICMJE) recommendations for manuscripts submitted to biomedical journals,
the Committee on Publication Ethics (COPE) guidelines, and the Principles of Transparency and Best Practice in Scholarly Publishing.
website: www.wjnu.org editorial contact:
[email protected]
Address: 9225 Leslie Street, Suite 201, Richmond Hill, Ontario, L4B 3H6, Canada
© Elmer Press Inc. All Rights Reserved.
Disclaimer: The views and opinions expressed in the published articles are those of the authors and do not necessarily reflect the views or opinions of the editors and Elmer Press Inc. This website is provided for medical
research and informational purposes only and does not constitute any medical advice or professional services. The information provided in this journal should not be used for diagnosis and treatment, those seeking medical
advice should always consult with a licensed physician.
This website uses cookies to ensure you get the best experience on our website. Learn more Got it!
Cardioprotective Haemodialysis
FX CorDiax
Designed to Dialyse. Built for Cardioprotection
Cardioprotective Haemodialysis SP T
Protect your Patient
Cardioprotective Haemodialysis Wide-ranging cardioprotection
The reduction of risk factors for cardiovascular There have been tremendous improvements in the
diseases (CVD) is core to the development of dialysis quality and efficacy of haemodialysis (HD) therapy
systems and products at Fresenius Medical Care. in recent years. Despite this, cardiovascular diseases
Outstanding cardioprotection must be reflected in (CVD) remain the leading cause of death for patients
all levels of product development and application. with end-stage renal disease (ESRD).
Cardioprotective
Services Products
Over 30 years of experience in dialysis State-of-the-art technologies enable advanced
at your service. cardioprotective therapies.
}CorDiax product line:
}Project Planning and Consulting
• 5008 CorDiax and 5008S CorDiax
}Training and Education
• FX CorDiax haemodiafilter
}Technical Services
• BCM-Body Composition Monitor
}Water Quality Service (WQS)
}Classix product line:
}Medical Information Services
• 4008S classix
• FX classix dialysers
}Therapy Data Management System (TDMS)
}Online Purification Cascade (OPC)
2
Moreover, both overall and cardiovascular mortality are achieve the best therapeutic performance – meaning
markedly greater in ESRD patients than in the general improved clinical outcomes and better quality of life,
population. This is why we put Cardioprotective Haemo- enhanced control of therapy costs, and simpler, safer
dialysis on the SPOT. A comprehensive approach that handling.
includes services, products and therapies is needed to
Haemodialysis
Outcomes Therapies
Achieving better outcomes with cardioprotective Cardioprotective therapies designed by
therapies. the world market leader in haemodialysis.
}Reduced mortality risk
}High-Flux dialysis
}Fewer cardiovascular complications
}HighVolumeHDF ®
}Optimised use of resources
}Advanced Fluid Management
3
The new FX CorDiax
Cardioprotection – at the heart of long-term haemodialysis
The effects of chronic kidney disease (CKD) as well as Middle molecule removal means the selective
the effects of dialysis itself can lead to cardiovascular filtration of a broad range of uraemic toxins with a
diseases [e.g. atherosclerosis and left ventricular molecular weight higher than 500 Dalton (Da). At the
hypertrophy (LVH)], the largest causes of death in same time, the membrane should prevent the loss of
haemodialysis patients. Improved middle molecule
1
substances known to be associated with patient
removal, through enhanced High-Flux membranes survival, such as serum albumin. This high sieving
for haemodiafiltration, can substantially reduce potential must be accompanied by excellent
these risks.2 biocompatibility.
Innovative membranes such as Helixone® provide
A number of large, multi-centre studies show that enhanced filtration, with high sieving of low molecular
the use of High-Flux membranes improves patient weight (LMW) and middle molecular weight (MMW)
survival and quality of life. 3
substances as well as volume exchange, while
Urea
Albumin
β2-microglobulin
PR
O
D
U
CT
S
4
reducing the induction of inflammatory cascades SPOT on:
CVD are the largest
that are central to many aspects of CVD. }
causes of death in
State-of-the-art technologies such as Fresenius’ dialysis patients.
Nano Controlled Spinning (NCS™) and INLINE steam } High-Flux membranes
enhance middle
sterilisation are the result of continual innovation at molecule removal and
reduce risk factors.
Fresenius Medical Care.
} FX CorDiax for
Advances in material and production technologies enhanced survival and
have permitted improvements in the wall structure better outcomes.
by opening up the support region of the membrane.
The Helixone®plus membrane in the new
FX CorDiax dialysers improves the clearance of
middle molecules while the loss of essential blood
components such as albumin is curtailed. The
Helixone®plus membrane upgrades the FX-class®
dialyser into the CorDiax product line, which provides
products for superior cardioprotective therapies.
5
The new FX CorDiax
Advances in fibre design allow better removal of uraemic toxins
The fibre support region underneath the inner
}
surface has been “opened up”, optimising
porosity and therefore also the convective
filtration (“flushing”) of larger uraemic toxins such
as β2-microglobulin (5 11,800 Da) or myoglobin
(5 17,000 Da).
} At the same time the size of the pores of the inner
surface area was not increased to avoid flushing
of albumin.
FX CorDiax eliminates more middle molecules 100
90
than FX 80
Removal ratio [%]
Maduell et al. determined middle molecule removal of 70
60
FX CorDiax 60 compared to FX 60 in HDF postdilution
50
treatments. Significantly higher removal rates were 40
observed with FX CorDiax for 30
20
}Urea (60 Da)
10
}β2-microglobulin (11.8 kDa) 0
0 10,000 20,000 30,000 40,000 50,000 60,000 70,000
}Myoglobin (17.2 kDa) Molecular weight [Da]
}Prolactin (22.9 kDa) FX CorDiax 60 FX 60
}α1-microglobulin (33 kDa)
Removal ratios of FX 60 and FX CorDiax 60 dialysers in post-
dilution HDF 1 (QB = 400 mL/min, QD = 500 mL/min)
The authors concluded that “… treating patients with
online haemodiafiltration and FX CorDiax 60 instead
of FX 60 dialysers results in significantly increased
reduction ratios of middle sized molecules without
clinically relevant changes in albumin loss.
PR
O
D
U
CT
S
1 Maduell et.al.; ERA-EDTA Congress 2013, May 20, Poster Number MP 390.
6
}The benefits of the advanced fibre design is SPOT on:
High selective
not limited to better middle molecule removal. }
permeability for
The reduced transmembrane resistance of middle molecules
the FX CorDiax improves the removal of low Improved removal
}
of phosphate
molecular weight substances, e.g. phosphate.
280
Phosphate clearance (mL/min)
260
240
220
200
180
FX CorDiax 60 Xevonta Hi 15 Polyflux® 140 H
Comparison of aqueous in-vitro clearances of phosphate
(QB = 300 mL/min, QD = 500 mL/min). Investigations carried out
by EXcorLab GmbH, an Accredited Calibration and Testing
Laboratory.
}In a postdilution HDF treatment the use of
FX CorDiax 100 dialysers resulted in a significantly
higher clearance of β2-microglobulin than FX 100
and Polyflux® 210H dialysers. The albumin loss was
low and similar for all dialysers.2
* p < 0.001 FX CorDiax 100 vs. FX 100 vs. Polyflux® 210 H
200
Albumin loss (g/4h)
β2-m clearance (mL/min)
150.4*
136.6
150
115.5
FX CorDiax 100 1.74 ± 1.01
100
50
FX 100 2.10 ± 1.00
0
FX CorDiax 100 FX 100 Polyflux® 210H Polyflux® 210H 1. 31 ± 0.12
FX CorDiax offers significantly better β2-m clearance Comparison of albumin loss in a post-dilution HDF treatment
than FX and Polyflux® 2 (QB = 350 mL/min, QD = 800 mL/min, QS = 80 mL/min) 2
2 Bock A. et al., J Am Soc Nephrol (2013); 24: SA-PO404.
7
The new FX CorDiax
Clearing middle molecules improves survival rates
The use of High-Flux membranes instead of Low-Flux
membranes improved patient survival rates.
}A meta-analysis of 33 randomised controlled
trials and 3,820 patients showed a reduction in
cardiovascular mortality of 17 %.1
}All-cause mortality in diabetics and patients
with albumin ≤ 4 g/dl was significantly improved.2
250 Patients with serum albumin ≤ 4 g/dL
p < 0.001
Survival probability of patients
235 1.0
200
Cardiovascular events
17 % 195 0.8
Reduction p = 0.032
150
0.6
100 0.4
High-Flux Membrane
50 0.2
Low -Flux Membrane
0
0 0 12 24 36 48 60 72 80
Low-Flux HD High-Flux HD
N = 1,302 N = 1,310 Months
Comparison of cardiovascular mortality when High-Flux Comparison of all-cause mortality when High-Flux
instead of Low-Flux dialysers were used 1 instead of Low-Flux dialysers were used 2
(Graph adapted from original publication) (Graph adapted from original publication)
PR
O
D
U
CT
S
1 Palmer S.C. et al., Cochrane Database of Systematic Reviews (2012);
Issue 9.
2 Locatelli F. et al., J Am Soc Nephrol (2009); 20: 645-654.
8
Cardioprotective Haemodialysis
FX-class® Design
Innovation at all Levels
FX-class® Design
Cardioprotective Haemodialysis SP T
Protect your Patient
Superior by Design
Several state-of-the-art technologies have Optimised dialysate flow
been combined to create the distinctive, The 3-dimensional microwave structure of
functional features of FX-class dialysers,
®
the fibre ensures uniform radial dialysate
which are refined and optimised for flow around each fibre within the bundle by
performance, safety and handling: preventing fluid channelling, thereby further
enhancing clearance values and improving
Design of dialyser housing and fibre
} the overall performance of the dialyser.
bundle for more uniform dialysate flow.
Better haemodynamics
Refined blood inlet port for improved
} The lateral blood-inlet port ensures more
haemodynamics. homogenous blood flow in the dialyser
header, preventing stagnation zones. The
Advances in material and production design essentially eliminates the risk of
technologies have permitted improvements kinking, contributing to improved safety.
in the wall structure of the Helixone®plus
membrane of the FX CorDiax. Enhanced convection
The more open structure of the
More porous Helixone plus membrane
} ®
Helixone®plus membrane support region
wall for higher clearance of middle serves to reduce diffusion resistance
molecules. and increases convective filtration.
This facilitates clearance of a broad range
of uraemic toxins, especially the middle
molecules.
PR
O
D
U
CT
S
10
Kind to the environment SPOT on:
Optimised performance
Advanced design goes beyond direct }
due to radial dialysate
functionality, it also has to be easy on flow.
the environment. FX-class® dialysers weigh Enhanced clearance
}
of middle molecules
less than half as much as previous dialysers, enabled by a more
porous support region
and at the same time use ecologically
of the membrane.
friendly plastics. This means a lower car-
bon-footprint as a result of fewer materials,
less packaging, less fuel for transport and
cleaner waste management. Due to less
priming volume and easy preparation,
costs are reduced as well.
Homogenous blood Advanced
flow path Helixone®plus membrane
3-dimensional wave structure
of the fibre
Radial dialysate flow
11
Cardioprotective Haemodialysis
INLINE Steam Sterilised Dialysers
The Pure Difference
INLINE Steam Sterilised Dialysers
Cardioprotective Haemodialysis SP T
Protect your Patient
Clean and safe Purity ensured – with steam
FX-class® dialysers are sterilised using No chemical residuals with INLINE
the unique INLINE steam sterilisation steam sterilisation
process specifically developed by No need for gamma sterilisation – high en-
Fresenius Medical Care. ergy ionising radiation can degrade and alter
the material chemistry, producing potential
During the INLINE steam sterilisation cytotoxic and carcinogenic residuals inside
process, both the blood and the dialysate the dialyser.1
compartments are rinsed continuously
with steam > 121°C. Since no additional Low rinsing volumes
chemicals are needed for cleaning or Minimal preparation time – since dialysers
sterilisation, the finished dialysers have are clean on arrival, rinsing times prior to use
extremely low levels of residuals. are substantially reduced.
Less rinsing – lower costs
Lower rinsing volumes mean reduced
preparation times and costs.
PR
O
D
U
CT
S
1 Shintani H. et al., Journal of Analytical Toxicology (1989);
13: 354-357.
2 Müller T. F. et al., Nephron (1998); 78: 139-142.
14
SPOT on:
Reduced risk of blood
}
contact with toxic
residuals.1
Activation of the
}
complement system
is reduced.2
Integrity test: Air pressure is applied to the fibre
bundle from one side while the other side contains sterile
water. If any leakages were present in the membrane,
air would pass the membrane and create bubbles.
INLINE steam sterilisation process and integrity test
15
Cardioprotective Haemodialysis
Superior Endotoxin Retention
Purity by Design
Superior Endotoxin Retention
Cardioprotective Haemodialysis SP T
Protect your Patient
What are endotoxins? Greater protection through
active prevention
Endotoxins are large molecules from the Once in the patient’s blood, endotoxins can
outer membrane wall of gram-negative induce complement and leucocyte activation,
bacteria. Chemically, endotoxins are lipopoly- leading to inflammatory responses.
saccharides (LPS), having lipid and poly- Sometimes, these may result in acute reactions
saccharide components. such as fever, headaches, convulsions or low
blood pressure. In the longer term, they may
Microbial contamination of water or fluid also contribute to chronic conditions such as
conduits can therefore lead to the presence amyloidosis, an increased need for EPO,
of endotoxins in dialysis fluid. immune disorders or accelerated atheroscler-
osis. Atherosclerosis and cardiovascular
While intact endotoxins are relatively large mol- diseases are the most frequent causes of
ecules, their smaller endotoxin fragments death for dialysis patients.
may pass across dialysis membranes into the
patient’s blood via backdiffusion or backfiltration.
Endotoxins Dialysate
Dialysis
Membrane
Complement Activation
Blood
Membrane-Leucocyte Interaction
+ C5a C5b Blood
Leucocyte Activation
Reactive Cytokine
Oxygen Release
Species (IL-1, IL-6, TNF-_)
Complement + Endotoxin
Mediated Leucocyte Activation
Inflammatory responses simulated by blood-membrane interactions and bacterial dialysate contaminants
PR
O
D
U
CT
S
18
Membranes, such as Helixone®, which have SPOT on:
Absence of endotoxins
a high endotoxin retention capacity, protect the }
minimises inflammation.
patient from inflammation, particularly when Reduced cardiovascular
}
ultrapure dialysate is not available.1 risk factors.
4.5
4.0
0.56
3.5
Endotoxin Adsorption
(EU/cm2 membrane)
3.0
2.5
2.0 0.48
1.5
0.17
1.0
0.5
0.03
0
Polyflux®
Nephral® FX 60 – Diacap®
140H – ST 400 – Helixone® HI PS 18 –
Polyether- Polyacrylo- α-Poly-
sulfone nitrile sulfone
Endotoxin adsorption per cm2 membrane surface area
after 120 min in-vitro dialysis with contaminated dialysate
(endotoxin from bacterial culture filtrates; initial concentra-
tion 50 EU/mL).1
(Graph adapted from original publication)
How to prevent endotoxins
entering dialysis fluids
} Improved overall hygiene management.
} Mandatory use of ultrapure dialysis
fluid by using dialysis fluid filters such
as DIASAFE®plus to remove residual
endotoxins from dialysis fluid.
} Use of dialysis membranes with high
endotoxin retention capacities, particularly
when ultrapure dialysate is not available
(e.g. Helixone® or Helixone®plus).
1 Weber V. et al., Blood Purif (2003); 21: 365.
19
Cardioprotective Haemodialysis
Enhanced Middle Molecule Removal
Open up to Porosity
Enhanced Middle Molecule Removal
Cardioprotective Haemodialysis SP T
Protect your Patient
Key to optimal middle molecule removal
Solutes encounter resistance while traversing
the membrane wall. Resistance to solute
transport is affected, in part, by pore size
Inner surface
at the inner surface and the porosity of the
membrane wall.
Furthermore, wall structure and thickness
Support region
as well as inner fibre dimensions and
3-dimensional microwave structure play
important roles in transmembrane flux.
Close-up of the inner surface and the
support region of the Helixone®plus membrane
The new membrane structure of
Helixone®plus allows the easy passage of
middle molecules across the more porous
support region of the membrane.
}The structure of the support region
is crucial to overall performance.
}Membrane porosity, together with the
pore size, regulates the transport of
middle molecules.
PR
O
D
U
CT
S
22
Refined membrane architecture SP T
New production technology combined with SPOT on:
Optimised membrane
INLINE steam sterilisation allows crucial }
porosity for
enhancements of membrane porosity, enhanced removal of
middle molecules.
reducing flow resistance and improving
transport across the membrane.
}Significantly improved removal of middle
molecules while preventing the loss of
useful substances, such as serum
albumin.
23
Cardioprotective Haemodialysis
High-Flux Dialysis
Improved Survival – Better Outcomes
High-Flux Dialysis
Cardioprotective Haemodialysis SP T
Protect your Patient
Extended survival
Use of High-Flux membranes enhances the lities such as HighVolumeHDF® may contribute
removal of uraemic toxins, particularly middle towards reduced risk of death.
molecules such as β2-microglobulin.
The results of the MPO study indicate the bene-
A growing body of evidence has emerged in recent ficial effect of High-Flux membranes in terms of
years demonstrating that use of High-Flux dialysis reduced mortality for patients with serum albumin
membranes as well as advanced treatment moda- levels ≤ 4.0 g/dL or diabetes.1
High-Flux Membrane
Diabetic patients (p = 0.039)
Low-Flux Membrane
1.00
0.90
Survival probability of patients
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0 12 24 36 48 60 72 84
Months
Kaplan-Meier survival curves for the subpopulation of patients with diabetes (log-rank test p = 0.039) 1
(Graph adapted from original publication)
PR
O
D
U
CT
S
26
Reduced complications
Enhanced middle molecule removal contributes SPOT on :
High-Flux dialysis
towards reducing the complications of haemo- }
can reduce secondary
dialysis as well as improving long-term patient diseases.
outcomes by affecting:2 Prolonging patients’
}
lives.1
Control of anaemia
}
} Inflammation – lower CRP levels.3 and amyloidosis.
} Anaemia – haemoglobin levels improve
at lower EPO doses.4
} Amyloidosis – efficient removal of β2-micro-
globulin and other middle molecules can redu-
ce the relative risk of developing amyloidosis
by up to 50 %.5, 6
} Immune dysfunction – aberrant suppression
of IFN-amay be corrected.7
The clinical benefits of High-Flux HDF are described
in more detail in the chapter “Clinical Benefits of
the Removal of Middle Molecules”.
27
Protect your Patient
Evolution of fibre design
Reducing the inner fibre diameter from 200 µm to partments. Together with structural refinements
185 µm acts to increase internal filtration, thereby to the support region of the fibre, this enables
increasing the pressure gradient along the length improvements in both diffusive and convective
of the fibre. This results in a greater pressure transport, which is of particular importance when
difference between the blood and dialysate com- performing High-Flux haemodialysis.
Blood Inlet
Pressure
Dialysate Inlet
Pressure
6p
6p
Dialysate
Outlet Blood Outlet
Pressure Pressure
Ultrafiltration Internal Filtration
Length Dialyser
PR
O
D
U
1 Locatelli F. et al., Journal of American Society of Nephrology
CT
(2009); 20: 645-654.
S
2 Tattersall J. et al., Nephrol Dial (2007); 22(Suppl.2); ii5-ii21.
3 Pedrini L. A. et al., Nephrol Dial Transplant (2011);
doi: 10.1093/ndt/gfq761.
4 Merello Godino J. I. et al., Int J Artif Organs (2002);
25(11): 1049-1060.
28
} Modification of the inner diameter increases the SPOT on:
Specific fibre design
pressure gradient between blood and dialysate }
leads to increased removal
compartments. of middle molecules.
} The result is improved clearance of middle
molecules such as vitamin B12, inulin,
β2-microglobulin and myoglobin.8
} The increased pressure gradient combined
with structural refinements to the membrane
(support region) enhances diffusive as well as
convective filtration, especially when performing
High-Flux haemodialysis with FX CorDiax.
70 210
β2-microglobulin
60 200
β2-m clearance (mL/min)
Urea Clearance (mL/min)
50 190
Urea
40 180
30 170
20 160
10 150
QB= 250 mL/min, QD= 500 mL/min
0 140
175 200 250
Inner diameter of membrane [µm]
Reduced inner diameter improves middle molecule elimination8
(Graph adapted from original publication)
5 Koda Y. et al., Kidney Int (1997); 52: 1096-1101.
6 Locatelli F. et al., Kidney Int (1999); 55: 286-293.
7 Lonnemann G. et al., Blood Purif (2003); 21(3): 225-231.
8 Dellanna F. et al., (1996); NDT 11 (Suppl 2): 83-86.
29
Protect your Patient
Guidelines recommend High-Flux dialysers
Clinical practice guidelines in Europe recommend
the use of High-Flux haemodialysers:
European Renal Best Practice Advisory
Board; Guideline 2.1:
“Synthetic High-Flux membranes should
be used to delay long-term complications of
haemodialysis therapy … even in low-risk
patients...” 1
The Renal Association (UK):
“Suggest that high-flux dialysers should be
used instead of low-flux dialysers to provide
haemodialysis. Evidence of improved patient
survival with the use of high-flux membranes
is restricted to incident patients, who have
lower serum albumin concentrations (< 4 g/L)
or have diabetes mellitus, and prevalent
patients who have been on haemodialysis
> 3.7 years” 2
1 Tattersall J., Nephrol Dial Transplant (2010); 25: 1230–1232.
2 Mactier R. et al., Renal Association 2009, Renal Association
Clinical Practice Guidelines. Haemodialysis membranes
(Guidelines 4.1 to 4.5). http://www.renal.org/clinical/
GuidelinesSection/Haemodialysis.aspx. Accessed 2 Dec. 2012.
Cardioprotective Haemodialysis
HighVolumeHDF ®
Advance the Experience
HighVolumeHDF ®
Cardioprotective Haemodialysis SP T
Protect your Patient
Better filtration
In recent years, there has been increased interest in HighVolumeHDF ® improves patient outcomes and
more efficient haemodialysis treatment modalities. exerts beneficial effects on the main cardiovascular
The main emphasis today is on the efficient removal risk factors:
of a wide range of uraemic toxins, particularly larger
middle molecules such as β2-microglobulin, a }Intradialytic haemodynamic stability 1
surrogate of middle molecules. However, excessive }Anaemia 2
loss of useful substances such as albumin needs }Inflammation 3
to be curtailed. }Serum β2-m and phosphate levels 4, 5, 6
The high removal of larger solutes during HighVolumeHDF ® is currently considered as the
HighVolumeHDF® is achieved through a combina- most efficient renal replacement therapy.
tion of two principles: diffusion and convection at
high substitution volumes. Solute removal by con-
vection occurs along a pressure gradient facilitated
by the ultrafiltration of fluid across a highly perme-
able membrane.
PR
O
D
U
CT
S
32
Improved survival
The Catalonian high-volume HDF study,7 on behalf SPOT on:
High convective
of the Estudio de Supervivencia de Hemodiafil- }
transport enhances
tración On-Line (ESHOL) study group, is a mul- the removal of uraemic
toxins, especially in the
ti-centre, prospective randomised controlled trial, middle molecular range.
which showed a wide range of benefits for patients
being treated with high-efficiency post-dilution HDF
(HighVolumeHDF ®). Achieving a mean delivered
total substitution volume of 21 L/session should
therefore be the target for every HDF treatment.
The primary outcome all-cause mortality was
significantly reduced for the patients being treated
with HighVolumeHDF ®.
Follow-up (months)
1.0
Survival probability of patients
0.8
0.6
p = 0.010
0.4
Online haemodiafiltration*
0.2
High-Flux HD**
0
0 6 12 18 24 30 36
Results from the Catalonian high-volume HDF study 7
*median delivered convective volume ranged from 23 to 24L /
session
**92% on High-Flux HD
Improved survival Reduced treatment costs
30% (p = 0.01) 22% risk
risk reduction in all-cause mortality reduction in all-cause
hospitalisation (p = 0.001)
55% risk
reduction in mortality from infection
(p = 0.03) Better patient well-being
61% risk 28% risk
reduction in mortality from stroke reduction in incidence of
(p = 0.03) hypotensive episodes (p < 0.001)
1 Locatelli F. et al., J Am Soc Nephrol (2010); 21: 1798–1807.
2 Bonforte G. et al., Blood Purif (2002); 20: 357–363.
3 Pedrini L. et al., Nephrol Dial Transplant, advanced access published Jan 18, 2011.
4 Canaud B., Contrib Nephrol (2007); 158: 216–224.
5 Penne L. et al., Clin J Am Soc Nephrol (2010); 5: 80–86.
6 Davenport A., Nephrol Dial Transplant (2010); 25: 897–901.
7 Maduell F. et al., J Am Soc Nephrol (2013); 24: 487–497.
33
Protect your Patient
FX CorDiax haemodiafilter – Superior by design
HighVolumeHDF ® therapy requires specially
p < 0.001
designed filters. Stepping up to this challenge, we 650
developed the FX CorDiax haemodiafilter for 600
HighVolumeHDF with the most efficient removal of
® 550
middle molecules while minimising albumin loss. 500
PDP mmHg
450
}Increased fibre lumen for better flow 400
conditions 350
An increase of its inner diameter results in a 300
200
substantially reduced pressure drop within 15' 1h 2h 3h 4h 15' 1h 2h 3h 4h
FX 80 FX 800
a hollow fibre according to the Hagen Poiseuille
law. Differences in the capillary diameter of a
Reduced dialyser inlet pressure of FX 800 (210 µm) vs. FX 80
dialyser can therefore affect its performance and (185 µm) 1
the quality of the treatment provided to a (Graph adapted from original publication)
patient. The inner diameter of FX-class® haemo-
diafilters is 210 µm compared to 185 µm of
FX-class® HD filters. The larger inner diameter
facilitates improved flow conditions which
allowed for a significantly higher convective
volume in a HDF treatment.1
210 µm
The 210 µm fibre lumen of FX CorDiax haemodiafilters
optimises blood flow conditions within the dialyser for
maximal HighVolumeHDF ® performance.
PR
O
D
U
CT
S
1 Vega Vega O. et.al.; ERA-EDTA Congress 2012, Poster 457—FP.
34
Cardioprotective Haemodialysis
Clinical Benefits of the Removal of Middle Molecules
When Performance is Priority
Clinical Benefits of the Removal of Middle Molecules
Cardioprotective Haemodialysis SP T
Protect your Patient
Improved survival with High-Flux membranes
On top of traditional cardiovascular risk factors, in-
creased middle molecule levels such as β2-micro-
globulin (β2-m) pose an additional risk for the devel-
opment of cardiovascular diseases (CVD) in end
stage renal disease (ESRD) patients. The European
Uremic Toxin Work Group (EUTox) confimed the
power of β2-m to predict overall and cardiovascular
mortality and cardiovascular events in patients at
different stages of CKD.1
Thus, enhanced middle molecule removal contrib-
utes towards improving long-term patient outcomes
and reducing dialysis related complications.
1.0
Cardiovascular event-free survival
0.8
0.6
Log-rank P-value 0.0077
0.4
0.2
Above median β2-m Below median β2-m
0
0 200 400 600 800 1000 1200 1400
Months
Kaplan-Meier estimates of the probability of cardiovascular
event-free survival of predialysis patients, as a function of median
plasma β2-m level 1
(Graph adapted from original publication)
PR
O
D
U
CT
S
36
Cardioprotective Haemodialysis
} Dyslipidaemia – the use of High-Flux Helixone® SPOT on:
Improved patient
membranes improves plasma lipid profiles,2 }
survival.1
reducing levels of LDL (low-density lipoprotein) Reduced risk factors of
}
and VLDL (very low-density lipoprotein) and atherosclerosis.3
increasing those of protective HDL (high-density
lipoprotein). The levels of triglycerides and oxidised
LDL, an indicator of oxidative stress and a specific
risk factor for atherosclerosis, are also significantly
reduced using Helixone® membranes.3
300 60
p = 0.02 p = 0.008
250 50
Triglycerides (mg/dL)
200 40
Ox-LDL (U/L)
150 30
100 20
50 10
0 0
F7 HPS FX 100 F7 HPS FX 100
Improving plasma lipid profiles: reduction of ox-LDL and
triglycerides with FX 100 dialysers 3
(Graph adapted from original publication)
37
Protect your Patient
Cardioprotective Haemodialysis
}Amyloidosis – a debilitating complication of }Inflammation – specialised production processes
longterm haemodialysis, amyloidosis involves the such as INLINE steam sterilisation as well as the
build-up of β2-microglobulin. FX-class High-Flux
®
high endotoxin retention properties of FX-class®
dialysers efficiently remove β2-microglobulin dialysers contribute to reducing the levels of endo-
and other middle molecules, reducing the risk of toxin exposure during haemodialysis. This results in
carpal tunnel syndrome.4, 5 the reduced induction of inflammatory responses.2
Haemoglobin constant at 10.5 g/dL
7,000
HDF
EPO dosage (U/week)
6,000
5,000
4,000
0
0 3 6 9
Months
With High-Flux membranes, it was possible to progressively reduce
the EPO dose while maintaining Hb control 6
(Graph adapted from original publication)
PR
O
D
U
CT
S
38
}Anaemia management – it was shown that SPOT on:
Improved anaemia
High-Flux membranes improved control of anaemia }
control.6, 7
in EPO hypo-responsive patients while allowing a Reduced inflammation.2
}
progressive reduction in the exogenous EPO dose Reduced risk of CVD
}
due to minimising the
by 25 to 45 %.7 Hence, High-Flux membranes offer
risk factors.
the potential to reduce EPO costs.
Low-Flux Fresenius High-Flux Fresenius High-Flux Fresenius
Polysulfone® Polysulfone® Polysulfone®
14.0 250
p < 0.001
Weekly EPO dose [IU/kg/week]
12.0
200
Haemoglobin (g/dL)
10.0
p < 0.001
8.0 150
6.0 100
4.0
50
2.0
0.0 0
before after 6 before after 6 before after 6
months months months
Recovery of haemoglobin (Hb) levels was significantly better after 6 months for patients treated with
High-Flux vs Low-Flux membranes. Further, in this patient group the mean EPO dose was significantly lower.7
(Graph adapted from original publication)
The FX CorDiax allows the enhanced removal of
middle molecules which, together with other factors,
contributes towards improved survival.
1 Liabeuf S. et al., Kidney International (2012) 82, 1297.
2 Merello Godino J. I. et al., Int J Artif Organs (2002); 25(11): 1049-1060.
3 Wanner C. et al., JASN (2002); 13 (SU-P0645): 600A.
4 Ahrenholz P. G. et al., Clinical Nephrology (2004); 62: 21-28.
5 Koda Y. et al., Kidney Int (1997); 52: 1096-1101.
6 Bonforte G. et al., Blood Purif (2002); 20: 357-363.
7 Ayli D. et al., J Nephrol (2004); 17: 701-706.
39
Performance Data
Sieving coefficients of FX CorDiax High-Flux Dialysers Molecular weight
and Haemodia filters (Dalton)
Albumin 66,500 < 0.001
Myoglobin 17,053 0.5
β2-microglobulin 11,731 0.9
Inulin 5,200 1
Membrane material Helixone®plus
Sterilisation method INLINE steam
Housing material Polypropylene
Potting compound Polyurethane
Units per box 24
FX CorDiax High-Flux Dialysers FX CorDiax 40 FX CorDiax 50 FX CorDiax 60 FX CorDiax 80 FX CorDiax 100 FX CorDiax 120
Clearance (QB = 300 mL/min)
Cytochrome c 12,230 48 * 76 96 111 125 136
Inulin 5,200 56 * 88 116 127 144 149
Vitamin B12 1,355 96 * 144 175 190 207 213
Phosphate 132 142 * 215 237 248 258 262
Creatinine 113 155 * 229 252 261 272 274
Urea 60 175 * 255 271 280 283 284
Clearance (QB = 400 mL/min)
Cytochrome c 12,230 – – 100 117 133 145
Inulin 5,200 – – 122 135 154 160
Vitamin B12 1,355 – – 191 209 229 237
Phosphate 132 – – 270 285 299 305
Creatinine 113 – – 290 303 321 325
Urea 60 – – 319 336 341 343
* Clearance (Q B = 200 mL/min)
Ultrafiltration coeff. (mL/h x mmHg) 21 33 47 64 74 87
In vitro performance: Q D = 500 mL /min, Q F = 0 mL /min, T = 37 °C (EN 1283). Sieving coefficients: human plasma, Q Bmax, Q F = 0.2 x Q Bmax (EN1283).
Ultrafiltration coefficients: human blood (Hct 32 %, protein content 6 %).
Effective surface (m²) 0.6 1.0 1.4 1.8 2.2 2.5
K 0 A Urea 547 886 1,164 1,429 1,545 1,584
Priming volume (mL) 32 53 74 95 116 132
Article number F00001588 F00001589 F00001590 F00001591 F00001592 F00002384
FX CorDiax Haemodiafilters FX CorDiax 600 FX CorDiax 800 FX CorDiax 1000
Clearance (QB = 300 mL/min, QF = 75 mL/min)
Cytochrome c 12,230 131 141 151
Inulin 5,200 144 156 166
Vitamin B12 1,355 204 217 225
Phosphate 132 257 267 271
Creatinine 113 271 277 280
Urea 60 285 291 292
Clearance (QB = 400 mL/min, QF = 100 mL/min)
Cytochrome c 12,230 149 160 172
Inulin 5,200 166 178 190
Vitamin B12 1,355 235 251 262
Phosphate 132 307 321 328
Creatinine 113 327 339 343
Urea 60 354 365 367
Ultrafiltration coeff. (mL / h x mmHg) 46 62 76
In vitro performance: Q D = 500 mL /min, T = 37 °C (EN 1283). Sieving coefficients: human plasma, Q B max, Q F = 0.2 x Q B max (EN1283).
Ultrafiltration coefficients: human blood (Hct 32 %, protein content 6 %).
Effective surface (m²) 1.6 2.0 2.3
K 0 A Urea 1,148 1,365 1,421
Priming volume (mL) 95 115 136
Article number F00001593 F00001594 F00001595
40
41
certified, PEFC/04-31-0000
© Copyright 2012 Fresenius Medical Care Deutschland GmbH
F00006435 MT-EN (1.0 BG-pppp 08.14)
Head office: Fresenius Medical Care Deutschland GmbH · 61346 Bad Homburg v. d. H. · Germany
Phone: +49 (0) 6172-609-0 · Fax: +49 (0) 6172-609-2191
www.fmc-ag.com
Theranova
DIALYZER
CHANGE CHANGE
ONE THING EVERYTHING
INTRODUCING THERANOVA FOR
EXPANDED HEMODIALYSIS [HDx]
Specifications and Comparison Guide
The Theranova Dialyzer is indicated for patients with chronic kidney failure who are prescribed
intermittent hemodialysis. It provides an expanded solute removal profile with increased removal
of various middle and large molecules (up to 45 kDa) that may play a pathologic role in the uremic
clinical syndrome. The Theranova Dialyzer is not intended for hemofiltration or hemodiafiltration
therapy. The total extracorporeal blood volume for the Theranova Dialyzer and the set should
represent less than 10% of the patient’s blood volume. For single use only.
Rx Only. For safe and proper use of this device refer to the Instructions for Use.
HDx ENABLED BY THERANOVA:
ONE STEP CLOSER TO THE NATURAL KIDNEY
Theranova, the next evolution in hemodialysis brings us a step closer
to the natural kidney by expanding clearance of conventional/large middle
molecules (500 – 45,000 Da)* compared to traditional high-flux membranes. 1-5
50%
High-Flux
T
Conventional/large middle
CVD is associated with Traditional high-flux
molecular (500-45,000 Da)
inflammation, atherosclerosis membranes have limited
uremic toxins have been linked to
and calcification. capability to remove conventional
the development of inflammation,
~ 50% of patients with kidney and large middle molecular uremic
cardiovascular disease (CVD) and
failure (KF) die from CVD 10-12
toxins (up to 45,000 Da) 13
other dialysis related comorbidities
4,6,9
CHANGE ONE THING.
HDx therapy showed a significant
The unique design of the Theranova reduction in hospital days and
membrane delivers superior in-center medication usage, in HDx therapy may improve
removal of conventional/ a retrospective analysis (n=81) . 15
patient reported kidney disease
large middle molecules (up to A Randomized Control Trial (n=171) Quality of Life (QoL) outcomes
45,000 Da), compared to high-flux
2-5 showed a significant reduction of including symptom burden,
membranes, while selectively 45% in all-cause hospitalizations . 19
restless leg syndrome (RLS)
retaining essential proteins and Improvement in certain inflammatory criteria, uremic pruritus, and
maintaining stable albumin levels 2,7,8 markers were observed in select dialysis recovery time.
1,2,5,14,17
patients (n=41) .
16
CHANGE EVERYTHING.
SIMPLY CHANGE THE DIALYZER MEMBRANE
AND EXPAND CLEARANCE FOR HD PATIENTS.5
*Conventional middle molecules, 500 Da – <25,000 Da, such as κ-Free Light Chains, large middle molecules 25,000 Da – 45,000 Da
such as λ-Free Light Chains1.
THERANOVA 400
PRODUCT CODE 955691
CLEARANCE/REDUCTION RATIOS
Theranova 400 Dialyzer Clearance (± 10 %, Cytochrome C ± 20 %, Myoglobin ± 30 %)
UF=0 mL/min QD = 300 mL/min QD = 500 mL/min QD = 800 mL/min
QB (mL/min) 200 300 400 500 600 200 300 400 500 600 200 300 400 500 600
Urea (60 Da) 191 246 272 285 291 198 282 344 388 418 199 293 376 445 502
Phosphate (95 Da) 179 225 250 266 276 192 261 311 348 376 196 279 345 400 446
Creatinine (113 Da) 184 232 258 273 282 194 269 323 362 391 198 285 357 416 465
Vitamin B12 (1.4 kDa) 148 178 199 214 226 164 207 239 264 285 174 227 267 301 329
Inulin (5.2 kDa) 119 140 156 169 180 133 161 183 200 216 144 178 204 225 245
Cytochrome C (12 kDa) 109 128 142 153 164 122 146 165 180 194 133 161 183 202 219
Myoglobin (17 kDa) 93 108 119 129 138 104 123 137 150 161 114 135 152 166 180
Mean Reduction Mean Overall Albumin Removal
Ratio (%)2 Clearance (mL/min)2 (g/treatment)2
300/500 400/600 300/500 400/600 QB/QD (mL/min) 300/500 400/600
β2-microglobulin [β2m] (12 kDa) 71.5 78.5 67.9 84.7 Median (range) 2.9 (1.5-3.9) 3.2 (1.9-3.9)
Myoglobin (17 kDa) 63.1 67.9 52.0 58.7
Kappa free light chains [κ-FLC] (23 kDa) 66.3 72.9 26.2 35.0
Complement Factor D [CFD] (24 kDa) 56.9 63.0 26.5 26.3
α1-microglobulin [α1m] (33 kDa) 21.7 24.8 3.8 3.3
Chitinase-3-like protein 1 [YKL-40] (40 kDa) 60.5 63.6 Only Reduction Ratio available
Lambda free light chains [λ-FLC] (45 kDa) 42.5 48.1 8.5 10.0
Theranova 400 Randomized Controlled Trial (RCT)18
Theranova High-Flux HD
Mean ± STD Reduction Ratio (%) Theranova 400 ELISIO-17H p value
(N=86) (N=85)
Lambda free light chains [λ-FLC] (45 kDa) 33.3±11.0* (p<0.001) 17.2±12.9 Hospitalization Events 18 31 --
Complement Factor D [CFD] (24 kDa) 45.0±10.4* (p<0.001) 23.6±12.1 Total Patient-Years 32.4 30.5 --
Kappa free light chains [κ-FLC] (23 kDa) 63.8±11.8* (p<0.001) 50.0±13.2 Hospitalization Rate (per PY) 0.56 1.02 0.0495
β2-microglobulin [β2m] (12 kDa) 18
73.6±10.4* (p<0.001) 65.4±9.4 Hospital Length of Stay (days) 4.11 4.63 0.4060
Open Label, Randomized Controlled Trial evaluating safety and efficacy; 21 US clinics; A post-hoc analysis of this RCT showed a significant
N=171; 86-Theranova 400; 85-Elisio-17H; 24 week study reduction of 45% (p<0.049) in all-cause hospitalizations.19
*Statistical signficance (< 0.001).
Pre-dialysis serum albumin levels (g/dL)18
Group Baseline Week 4 Chg vs Baseline Week 4 Week 8 Change vs Baseline Wk 8 Week 24
Control 4.0±0.3 4.0±0.2 0.0±0.2 4.0±0.3 0.0±0.2 4.1±0.4
Theranova 4.0±0.3 4.0±0.3 -0.1±0.2 3.9±0.3 -0.1±0.3 4.0±0.3
• Although small, a statistically-significant reduction in serum albumin noted at Weeks 4 and 8.
• The observed changes at 4 and 8 weeks were well below 5% and the mean levels were still below normal laboratory ranges.
• Changes from baseline were not statistically significant between the two study groups at Week 12 and thereafter.
• The primary safety endpoint of this study was the pre-dialysis serum level of albumin after 24 weeks of treatment.
• The analysis of the endpoint confirmed that Theranova 400 is non-inferior to Elisio-17H in maintaining pre-dialysis serum albumin
after 24 weeks of treatment based on a 5% non-inferiority margin (-0.1765 g/dL).
THERANOVA 400
PRODUCT CODE 955691
CHARACTERISTICS/COMPARISON GUIDE*
Characteristics
Theranova 400 Membrane Characteristics
Surface area (m ) 2
1.7 Maximum TMP (mmHg) 600
UF Coefficient in Vitro (mL/h.mmHg) 48 Storage conditions <30 °C / 86 °F
Residual blood volume (mL) <1 Blood flow rate QB (mL/min) 200 – 600
Priming volume (mL) ≥300 Dialysate flow rate QD (mL/min) 300 – 800
Comparison Guide
Baxter Fresenius Asahi KASEI Nipro BBraun
Theranova REVACLEAR Optiflux
(mL/min) 400 400 F200NR REXEED-18A REXEED-21A ELISIO-19H ELISIO-21H Diacap Pro 19H
Urea (60 Da) 344 338 330 330 340 343 346 332
Creatinine (113 Da) 311 315 289 309 317 309 319 305
Phosphate (95 Da) 323 297 290 289 299 296 304 278
Vitamin B12 (1.4 kDa) 239 213 189 197 212 215 219 202
UF Coefficient 48 54 62 71 74 76 82 97
Surface Area (m²) 1.7 1.8 2.0 1.8 2.1 1.9 2.1 1.9
Membrane PAES/PVP PAES/PVP Polysulfone Polysulfone Polysulfone Polynephron Polynephron Polysulfone
Electron
Sterilization Method Steam Steam Gamma-Ray Gamma-Ray Dry Gamma Dry Gamma Gamma
Beam
NOTE: Clearances in Vitro; QB=400 mL/min; QD=500 mL/min.
Comparison criteria is based on stated clearance values (Vitamin B12, Phosphate, Creatinine, Urea - in order, QB=400 mL/min).
This table may not be all-inclusive.
*Recommended cross-reference based on data from manufacturers’ published specification sheets.
FOR MORE INFORMATION, CONTACT YOUR BAXTER REPRESENTATIVE,
OR VISIT: HTTPS://HEMODIALYSIS.BAXTER.COM/HDx
REFERENCES
1. Theranova IFU, 2020. 2. Kirsch AH, et al. Performance of hemodialysis with novel medium cut-off dialyzers. Nephrol Dial Transpl 2017; 32(1):165-72. 3. Boschetti-de-Fierro
A, Voigt M, Storr M. et al. MCO Membranes: Enhanced Selectivity in High-Flux Class. Sci Rep 5, 18448 (2015). https://doi.org/10.1038/srep18448. 4. Zweigart C, Boschetti-de-
Fierro A, Hulko M, et al. Medium cut-off membranes - closer to the natural kidney removal function. Int J Artif Organs. 2017;40(7):328 -334. doi:10.5301/ijao.500060. 5. Lim JH,
Park Y, Yook JM, et al Randomized controlled trial of medium cut-off versus high-flux dialyzers on quality of life outcomes in maintenance hemodialysis patients. Nature/Sci Rep.
2020; 10:7780. 6. Hutchison CA, et al. The Rationale for Expanded Hemodialysis Therapy (HDx). Contrib Nephrol 2017; 191:142-52. 7. Krishnasamy R, Hawley CM, Jardine MJ,
Roberts MA, Cho Y, Wong M, Heath A, Nelson CL, Sen S, Mount PF, Pascoe EM, Vergara LA, Paul-Brent PA, Toussaint ND, Johnson DW, Hutchison CA. A tRial Evaluating Mid
Cut-Off Value Membrane Clearance of Albumin and Light Chains in HemoDialysis Patients (REMOVAL-HD): A Safety Device Study. Blood Purif. 2020; 1-11. 8. Bunch A, Sanchez
R, Nilsson LG, Bernardo AA, Vesga JI, Ardila F, Guerrero IM, Sanabria RM, Rivera AS. Medium Cut-Off Dialyzers in a Large Population of Hemodialysis Patients in Colombia:
COREXH Registry. Ther Apher Dial. 2020; 1-11. doi: 10.1111/1744-9987.13506. 9. Wolley M, Jardin M, Hutchison CA, Exploring the Clinical Relevance of Providing Increased
Removal of Large Middle Molecules. Clin J Am Soc Nephrol 2018;13:805-814. 10. Foley RN et al. Clinical epidemiology of cardiovascular disease in chronic renal disease Am J
Kidney Dis. 1998;32 (Suppl 3):112-9. 11. Cobo G et al. C-reactive Protein: Repeated Measurements Will Improve Dialysis Patient Care. Sem Dialysis 2016;29:7-14. 12. Yeun JY, et
al. C-Reactive Protein Predicts All-Cause and Cardiovascular Mortality. Am J Kidney Dis 2000;35:469-476. 13. Ronco C & La Manna G. Expanded Hemodialysis: A New Therapy
for New Class of Membranes. Contrib Nephrol, 2017:190:124-133. 14. Alarcon JC et al. Impact of medium cut-off dialyzers on patient-reported outcomes (PROs): COREXH
Registry. Blood Purif. 2020. doi: 10.1159/000508803. 15. Ariza JG et al. Measuring the association of switching patients from hemodialysis to expanded hemodialysis, with
hospitalizations, medication use, costs and patient utility. Virtual International ISPOR 2020. Poster PUK15. 16. Cantaluppi V et al. Removal of large-middle molecules, inhibition
of neutrophil activation and modulation of inflammation-related endothelial dysfunction during expanded hemodialysis (HDx). Nephrol Dial Transplant 2019. Abstract FO048.
17. Kharbanda K et al. A randomised study investigating the effect of medium cut-off haemodialysis on markers of vascular health compared with on-line haemodiafiltration
(MoDal study). Manchester University NHS Foundation Trust. Poster clinicaltrials.gov (NCT03510520). 18. Weiner DE et al. Efficacy and safety of expanded hemodialysis with
the Theranova 400 dialyzer: A randomized controlled trial. CJASN 2020. doi:10.2215/CJN.01210120. 19. Tran H et al. Reduction in All-Cause Hospitalization Events Seen in a
Randomized Controlled Trial Comparing Expanded Hemodialysis vs. High-Flux Dialysis. ADC Conference 2021 Poster #1070
Baxter and Theranova are trademarks of Baxter International Inc. or its subsidiaries
All other trademarks are the property of their respective owners.
US-RC46-200002 v5.0 03/21
INSPIRED BY LIFE
B. Braun Dialyzers
Diacap® Pro Dialyzer - THE TRUSTED PERFORMER
Easy Handling
Low priming volume
Efficient air elimination during preparation
Easy-to-open packaging and easy to remove and tighten protection
caps help staff to efficiently prepare and perform treatment
Removable second label for documentation
Efficient Performance
High permeability of a-Polysulfone Pro membrane enables HD targets
to be efficiently achieved during treatment
High fiber package density for consistent dialysate flow distribution
and less trapped air
High micro-undulation for homogeneous streaming behavior and less
membrane clustering
Wall thickness designed for better diffusive behavior
Technical and In-vitro
Performance Data Pro 13H Pro 16H Pro 19H
Blood flow (QB) mL/min 200 300 400 200 300 400 200 300 400
Urea 194 263 303 196 270 322 197 280 332
Creatinine 185 236 269 189 248 284 194 260 305
Clearance
Dialysate flow = 500mL/min Phosphate 178 220 249 184 230 261 186 242 278
Ultrafiltration flow (QF)=0mL/ Vitamin B12 133 151 167 143 166 183 150 180 202
min
Inulin 86 92 101 96 106 116 102 117 128
Cytochrome C 65 73 75 72 81 86 80 90 95
Inulin 1.0
SC, (Sieving Coefficient)
QB = 300mL/min ß₂-Microglobulin 0.7
QF = 60mL/min
Albumin < 0.001
Ultrafiltration coefficient mL/h/mmHg QB = 300mL/min 70 85 97
KoA Urea (QB = 300mL/min) 1010 1145 1415
Volume of blood compartment (mL) 82 100 120
Membrane material a Polysulfone Pro
Surface Area (m2) 1.3 1.6 1.9
Sterilization Oxygen-free Gamma
Recommended blood flow rate (mL/min) 200-500 200-500 200-500
Max. dialysate flow (mL/min) 800 800 800
Pressure drop blood (QB = 300mL/min) mmHg 101 82 72
Article No. 720DH13 720DH16 720DH19
Measuring conditions and physical data according to ISO 8637. Ultrafiltration coefficient according to
ISO 8637: bovine blood, Hct. 32%, protein 60 g/l, T=37 °C,
For more information: bbraunusa.com/diacappro
xevonta® Dialyzer - THE SCIENCE-BASED EXPERT
xevonta is the state-of-the-art dialyzer that
pushes the limits for the most challenging
dialysis tasks. The unique amembris membrane is designed to
accomplish dialysis therapy targets for non-adhering patients.
Sufficient elimination of uremic toxins (such as urea and phosphate)
The high permeability enables a high removal of middle molecules
Despite high permeability and toxin removal, albumin loss is minimal2
Maximized numbers of pores with precisely defined pore size for a
distinctive sieving profile
X-design provides the consistent homogeneous distribution of dialysis
fluid in the dialyzer
Technical and In-vitro
Performance Data Hi 18 Hi 20 Hi 23
Dialysate flow (Qd) mL/min 500 500 500 800 500 500 500 800 500 500 500 800
Blood flow (Qb) mL/min 200 300 400 500 200 300 400 500 200 300 400 500
Urea 198 281 341 414 199 287 349 427 199 290 354 439
Clearance Creatinine 194 263 304 372 196 271 316 390 197 276 324 403
Ultrafiltration flow
(QF)=0mL/min Phosphate 194 263 297 196 271 309 198 277 320
Vitamin B12 155 184 210 239 161 195 220 259 166 204 227 272
SC, (Sieving Coefficient) ß₂-Microglobulin > 0.8
QB = 300 mL/min
QF = 60mL/min Albumin < 0.001
Ultrafiltration coefficient mL/h/mmHg QB = 300mL/min 99 111 124
KoA Urea (QB = 300mL/min, QD = 500mL/min) 1450 1714 1900
Volume of blood compartment (mL) 110 125 141
Membrane material amembris polysulfone
Surface area (M2) 1.8 2.0 2.3
Sterilization Oxygen-free gamma
Wall thickness/inner diameter (µm) 35/195
Units per box 20
Article No. 7204403 7204404 7204405
Technical and In-vitro Performance Data is contained in product instructions for use.
For more information: bbraunusa.com/xevonta
Diacap® Pro and xevonta® Dialyzers
What is the Difference?
Diacap Pro Dialyzer xevonta Dialyzer
a Polysulfone Pro Type/Name Amembris Polysulfone
Inner
200 µm Diameter 195 µm
Wall
37 µm 35 µm
Thickness
~ 31,000 Da Cut Off ~ 35,000 Da
Permeability
70-97 99-124
Kuf mmHg
Surface
1.3/1.6/1.9 1.8/2.0/2.3
Area
High Flux Flux High Flux
Maximum 300mL Priming 300-450mL
Designed to achieve HD Designed for patients
targets with a smaller Strength with difficulty in
surface area achieving HD targets
Data On File
A better dialysis experience doesn’t just come from a box. It’s built from better
products, better partnerships, and better support.
For more information contact B. Braun Medical Inc. at 1-800-848-2066
www.bbraunusa.com/DiacapPro
B. Braun Medical Inc. | Bethlehem. PA |
www.bbraunusa.com/xevonta
Rx Only ©2019 B. Braun Medical Inc., Bethlehem, PA. All rights reserved. AVT005 12/19
Riigihangete vaidlustuskomisjon
Tartu mnt 85
10115 Tallinn Meie:23.01.2024 nr 2-10/7-1
[email protected]
VOLIKIRI
1. Käesolevaga volitab AS Lääne-Tallinna Keskhaigla (edaspidi LTKH) õigus- ja
hankeosakonna juristi Kaisa Suvi (isikukood 48705290369) esindama LTKH-t riigihangete
vaidlustuskomisjonis vaidlustusmenetluses riigihankele „Dialüüsi tarvikute ostmine“,
viitenumber 272185. Esindajal on õigus teha LTKH nimel kõiki menetlustoiminguid.
2. Volikiri on antud edasivolitamise õiguseta ning on tähtajatu.
(allkirjastatud digitaalselt)
Arkadi Popov
juhatuse esimees
[email protected]
AS Lääne-Tallinna Keskhaigla, Paldiski mnt 68, 10617 Tallinn, Eesti Vabariik
Telefon: 650 7393, Faks 650 7265, e-post
[email protected]
Registrikood: 10822269, Arvelduskonto: EE081010220022881019 SEB Pank
Riigihangete vaidlustuskomisjon Teie:
[email protected]
Meie: 23.01.2024 nr 2-6/14-3
Vastus OÜ MP AlpinTech vaidlustusele riigihankes „Dialüüsi tarvikute ostmine“,
viitenumber 272185
Hankija: AS Lääne-Tallinna Keskhaigla
registrikood: 10822269
aadress: Paldiski mnt 68, 10617 Tallinn
Hankija esindaja: jurist Kaisa Suvi
telefon: 6507 399
e-post:
[email protected]
Vaidlustaja: OÜ MP AlpinTech
registrikood: 16209624
Vaidlustaja esindaja: advokaat Ringo Heidmets
Adokaadibüroo GLIMSTEDT Estonia OÜ
registrikood: 14233883
e-post:
[email protected]
telefon: 5663 2589
1. SENINE MENETLUS
OÜ MP AlpinTech (vaidlustaja) esitas 17.01.2024 vaidlustuse (vaidlustus) riigihankes
„Dialüüsi tarvikute ostmine“ viitenumbriga 272185 (riigihange). Vaidlustaja taotles
Riigihangete vaidlustuskomisjoni (VAKO) kohustama AS-i Lääne-Tallinna Keskhaigla
(hankija) viima riigihanke alusdokumendid osades 1, 6 ja 35 vaidlustaja soovidega kooskõlla.
VAKO edastas vaidlustuse hankijale 18.01.2024 ning palus hankijal esitada kirjalik seletus
vaidlustuse kohta ja asja lahendamiseks vajalikud dokumendid hiljemalt 23.01.2024.
Käesolevaga esitab hankija enda vastuse vaidlustuse osas.
AS Lääne-Tallinna Keskhaigla, Paldiski mnt 68, 10617 Tallinn, Eesti Vabariik
Telefon: 650 7393, Faks 650 7265, e-post
[email protected]
Registrikood: 10822269, Arvelduskonto: EE081010220022881019 SEB Pank
2. HANKIJA KAHTLUS VAIDLUSTAJA REAALSES VÕIMALUSES RIIGIHANKES
OSALEDA
Riigihangete seaduse (RHS) § 192 lg 3 p 6 kohaselt jätab vaidlustuskomisjon vaidlustuse läbi
vaatamata ja tagastab selle oma otsusega vaidlustajale, kui vaidlustaja ei tõenda riigihanke
alusdokumentide vaidlustamisel vaidlustuskomisjonile vastuvõetaval viisil, et tal on reaalne
võimalus riigihankes osaleda.
Riigihangete seaduse kommenteeritud väljaande kohaselt võib riigihankes osalemise võime
hindamisel arvestada ettevõtja senist tegevusvaldkonda, praktilisi kogemusi, asjatundjate ja
oskustööliste töölerakendamise võimalusi, käivet jne1.
Riigihangete registrist nähtub, et vaidlustaja on varasemalt pakkujana osalenud kahes
riigihankes:
1. „Holste-Polli kunstlume tootmiseks vajaliku taristu ehitustööd“, viitenumber 269495;
2. „Pannjärve kunstlume tootmise süsteemi III etapi ehitus“, viitenumber 264505.
Kumbki eelpool nimetatud riigihangetest ei ole vähimalgi määral seotud dialüüsi tarvikute
müümisega. Avalikult kättesaadavate andmete kohaselt ei ole vaidlustaja ettevõttes töötajaid.
Viimase aasta jooksul pole vaidlustajal tekkinud maksustatavat käivet. Vaidlustaja 2022.
majandusaasta aruande kohaselt on vaidlustaja müügitulu 41651 eurot 100 %-liselt tekkinud
EMTAK-i koodi „Ärinõustamine jm juhtimisalane nõustamine“ alusel. Majandustegevuse
registri kohaselt on vaidlustaja 18.07.2023 esitanud kaks majandustegevusteadet, vastavalt
ehitamise ja elektritööde kohta.
Vaidlustaja poolt vaidlustatud riigihankega soovib hankija tervishoiuteenuse osutajana osta
dialüüsi tarvikuid 36 kuu jooksul kasutamaks neid lõppstaadiumi neerupuudulikkusega
patsiendite ravis. Sealjuures on riigihanke vaidlustatud osade eeldatav maksumus vastavalt:
1. osa 1 - 1 078 700,00 EUR;
2. osa 6 - 508 000,00 EUR;
3. osa 34 - 23 700,00 EUR;
s.o. kokku 1 610 400 EUR, mis ületab vaidlustaja 2022. a müügitulu rohkem kui 38-kordselt.
Lähtudes eelpool toodust on hankijal tekkinud kahtlus, et vaidlustajal ei pruugi vaidlustuse
rahuldamise korral olla reaalset võimalust riigihankes osaleda ning pakkumust esitada. Ka
vaidlustust lugedes jääb hankijale selgusetuks millise tootja milliseid tooteid plaanib vaidlustaja
hankija riigihankele pakkuda.
Seetõttu on hankija seisukohal, et vaidlustaja vaidlustus tuleb jätta läbi vaatamata ning
tagastada vaidlustajale RHS § 192 lg 3 p 6 alusel.
1
I.Pilving, M. Parind. § 192 kommentaar 22, lk 1091 M. Parind, M.A. Simovart (koost).
Riigihangete seadus. Kommenteeritud väljaanne. Juura 2019.
AS Lääne-Tallinna Keskhaigla, Paldiski mnt 68, 10617 Tallinn, Eesti Vabariik
Telefon: 650 7393, Faks 650 7265, e-post
[email protected]
Registrikood: 10822269, Arvelduskonto: EE081010220022881019 SEB Pank
Alternatiivselt esitab hankija oma seisukoha vaidlustusele, kui vaidlustust ei peaks läbi
vaatamata jätma.
3. RIIGIHANKE OSA 1
Esiteks heidab vaidlustaja hankijale ette, et hankija poolt riigihanke osale 1 esitatud tingimus
„[...] auruga steriliseeritud [...]“ on seadusega vastuolus. Vaidlustaja hinnangul takistab tingimus
riigihankes osalemast pakkujatel (sh vaidlustajal), kes soovivad pakkuda kiirgusega
steriliseeritud dialüsaatoreid. Vaidlustaja leiab, et ei saa eksisteerida ühtegi eluliselt usutavat ja
objektiivset põhjendust sellele, miks peavad dialüsaatorid olema steriliseeritud just auruga.
Hankija vaidlustaja seisukohaga ei nõustu.
Vaidlustaja on õigesti märkinud, et kiirgusega steriliseeritud dialüsaatorid on maksumuselt ja
funktsionaalsuselt konkurentsivõimelised auruga steriliseeritud dialüsaatoritega. Kindlasti on
kiirgusega dialüsaatori steriliseerimine ka lihtsam ja odavam, kui auruga steriliseerimine.
Dialüsaatori membraani funktsionaalseid omadusi (kliirens, läbilaskvuskoefitsient, UF
koefitsient) steriliseerimise meetod ei mõjuta. Samas on oluline rõhutada, et hemodialüüsi
protseduuri vajavad enamasti kroonilised haiged, kes käivad protseduuril 3-4 korda nädalas ja
sageli mitukümmend aastat. Patsiendi tervise seisukohast on seega dialüsaatori biosobivus mitte
vähem oluline, kui dialüsaatori funktsionaalsed omadused. Meditsiinikirjanduses on küllaldaselt
artikleid, mis näitavad, et suures doosis kiirgus tekitab dialüsaatorite materjalides (polüuretaan jt)
muutusi ning tekkivad genotoksilised ühendid ning vabad radikaalid, mille suurenenud
kontsentratsiooni on määratud patsiendi vereseerumis. Hankija lisab vaidlustusele ühe näitena
väljaandes World Journal of Nephrology & Urology avaldatud asjakohase teadusartikli „Do
Sterilization Process Really Make Difference in Dialysis-Induced Genotoxicity“ (Lisa 1).
Hankija soovib oma patsientidele pakkuda parimat võimalikku dialüüsravi ja auruga
dialüsaatorite steriliseerimine ei ole unikaalne vaid mõnele üksikule tootjale. Antud meetodit
kasutavad näiteks kaks maailma juhtivat dialüüsitarvikute tootjat Fresenius (Lisa 2, lk 14) ja
Baxter (Lisa 3, lk 4).
Hankija lisab täpsustuse korras, et riigihanke osale 2 „Sünteetiline hepariniseeritud High-Flux
dialüsaator“ on hankija esitanud, erinevalt riigihanke osast 1, tingimuse „gammakiirtega
steriliseeritud“, kuna hepariniseeritud (kaetud) membraani ei saa auruga steriliseerida.
Hepariniseeritud membraaniga dialüsaatorit kasutab hankija vaid erandolukorras tõsise
hüübimisprobleemiga patsiendil, kellele tavapäraselt hemodialüüsi protseduuri ajal kasutatavat
antikoagulanti (peamiselt madalamolekulaarset hepariini) manustada ei saa. Hankija kasutab
riigihanke osas 2 nimetatud dialüsaatorit vaid erandolukorras, sest oma olemuselt ei ole
hepariiniga kaetud membraaniga dialüsaator nii füsioloogiline ja ohutu kui ilma hepariinita
membraaniga dialüsaatorid.
Teiseks heidab vaidlustaja hankijale ette, et hankija poolt riigihanke osale 1 esitatud tingimus
„[...] Tsütokroom C kliirens vähemalt 120 ml/min (verevoolukiirus 300 ml/min, dialüsaadi
voolukiirus 500 ml/min, Qf=75 ml/min vastavalt EN 1283 või ISO8637)“ ei ole objektiivselt
põhjendatav ega vajalik.
AS Lääne-Tallinna Keskhaigla, Paldiski mnt 68, 10617 Tallinn, Eesti Vabariik
Telefon: 650 7393, Faks 650 7265, e-post
[email protected]
Registrikood: 10822269, Arvelduskonto: EE081010220022881019 SEB Pank
Samuti on vaidlustaja seisukohal, et tsütokroom C kliirens ei ole dialüsaatori parameetrina
üleüldse laialt levinud. Hankija vaidlustaja seisukohaga ei nõustu. Tsütokroom C kliirens
iseloomustab suuremate neerutoksiinide eemaldamise suutlikkust ning vaidlustaja väide, et antud
parameeter on omane vaid ühe kindla tootja dialüsaatoritele, ei pea paika. Hankija toob näitena
kolme juhtiva dialüsaatorite tootja brošüürid - Fresenius (Lisa 2, lk 40), Baxter (Lisa 3, lk 3) ja
B.Braun (Lisa 4, lk 2).
Eeltoodust lähtuvalt on hankija seisukohal, et vaidlustaja vaidlustus riigihanke osas 1 tuleb jätta
rahuldamata.
4. RIIGIHANKE OSAD 6 JA 35
Vaidlustaja hinnangul on põhjendamatu ja asjakohatu hankija poolt riigihanke osale 6 esitatud
tingimus „[...] täitmise mahuga mitte rohkem, kui 125ml.“ Hankija on seisukohal, et mida
väiksem on dialüüsi protseduuril ekstrakorporaalse ringe maht, seda väiksem on tõenäosus
hüpotensiooni tekkeks ning 125 ml maht on kindlasti eelistatum kui 135 ml. Hankija möönab
samas, et dialüüsi saab läbi viia ka 135 ml täitmise mahuga vereliinidega ning on teinud seetõttu
menetlusökonoomiast lähtuvalt riigihanke alusdokumentides vastava muudatuse.
Vaidlustaja hinnangul on ebaseaduslik hankija poolt riigihanke osale 36 esitatud tingimus, mille
kohaselt on lubatud pakkuda üksnes Clear Surf Wipes lappe, mis on niisutatud 1% Clear Surf
lahusega. Hankija eelistuseks on kasutada hankija kasutuses olevate dialüüsiaparaatide tootja
poolt soovitatud desinfitseerimislappe, mis on vajaliku efektiivsusega bakteritele, viirustele ja
seentele ning oleks ohutud aparatuuri pinnamaterjalidele. Hankija möönab samas, et samasuguse
efektiivsusega võivad olla mõne teise tootja pakutavad desinfitseerimislapid ning on teinud
seetõttu riigihanke alusdokumentides vastava muudatuse.
5. MENETLUSKULUD
Hankija on seisukohal, et vaidlustaja menetluskulud tuleb jätta vaidlustaja kanda. Vaidlustaja
oleks võinud enne vaidlustuse esitamist pöörduda hankija poole läbi riigihangete registri
ettepanekuga riigihanke alusdokumentide muutmiseks. Vaidlustaja seda pole aga teinud.
Riigihange on riigihangete registris ja Euroopa Liidu Teatajas avaldatud 21.11.2023, s.o. 2 kuud
tagasi. Hankija hinnangul on 2 kuud enam kui piisav aeg hankijale ettepaneku esitamiseks ning
vastuse ära ootamiseks. Selle asemel on vaidlustaja alustanud koheselt vaidlustusmenetlust. Kui
vaidlustaja oleks pöördunud hankija poole omapoolse ettepanekuga, poleks riigihanke osade 6 ja
35 osas menetlustuskulusid üldse tekkinud. Riigihanke osa 1 osas on hankija seisukohal, et
vaidlustus tuleb jätta rahuldamata ning menetluskulud jätta vaidlustaja kanda.
Eeltoodud asjaolusid arvesse võttes palub hankija:
1. jätta vaidlustaja vaidlustus läbi vaatamata RHS § 192 lg 3 p 6 alusel;
2. jätta vaidlustuse esitamisega seotud kulud vaidlustaja kanda;
3. lahendada asi kirjalikus menetluses.
AS Lääne-Tallinna Keskhaigla, Paldiski mnt 68, 10617 Tallinn, Eesti Vabariik
Telefon: 650 7393, Faks 650 7265, e-post
[email protected]
Registrikood: 10822269, Arvelduskonto: EE081010220022881019 SEB Pank
või alternatiivselt:
1. jätta vaidlustaja vaidlustus rahuldamata riigihanke osa 1 osas;
2. jätta vaidlustaja vaidlustus riigihanke osade 6 ja 35 osas läbi vaatamata RHS § 192
lg 3 p 5 alusel ning lõpetada vaidlustusmenetlus RHS § 197 lg 1 p 8 alusel;
3. jätta vaidlustuse esitamisega seotud kulud vaidlustaja kanda;
4. lahendada asi kirjalikus menetluses.
Lugupidamisega
(allkirjastatud digitaalselt)
Kaisa Suvi
Volitatud esindaja
Lisatud:
Lisa 1 Teadusartikkel väljaandes World Journal of Nephrology & Urology „Do Sterilization
Process Really Make Difference in Dialysis-Induced Genotoxicity“