dokumendiregister.ee
OtsingAsutusedMCP
Otsing›Rahandusministeerium
Sissetulev kiriAvalik

Vaidlustus

Rahandusministeerium · 14. september 2023
Seotud ettevõtted
DMI Capital OÜ (adressaat)
Viit
12.2-10/23-139/409-1
Registreeritud
14. september 2023
Dokumendi liik
Sissetulev kiri
Adressaat
DMI Capital OÜ
Saabumis/saatmisviis
e-post
Funktsioon
12.2 RIIGIHANGETEALANE TEGEVUS
Sari
12.2-10 Riigihangete vaidlustusmenetluse toimikud
Toimik
12.2-10/23-139
Vastutaja
Angelika Timusk (Rahandusministeerium, Riigihangete vaidlustuskomisjon)

Failid

  • 📎DMI Capital OÜ vaidlustus riigihankes 257906 MOSS Legal 20230913.asice731 KB

Sisu (failidest)

Rando Maisvee | MOSS Saatja: Sven Pedari <[email protected]> Saatmisaeg: kolmapäev, 13. september 2023 18:04 Adressaat: Rando Maisvee | MOSS Teema: Fwd: Uus sõnum riigihankes 257906 -------- Esialgne kiri -------- Pealkiri: Uus sõnum riigihankes 257906 Kuupäev: 06.09.2023 16:28 Saatja: Riigihangete register <[email protected]> Saaja: <[email protected]> Teile on riigihangete registris uus teade: Riigihanke 257906 "Ballistilised kiivrid ja lisadetailid" raames on saadetud teade: Tere Riigi Kaitseinvesteeringute Keskuse peadirektori 06.09.2023 käskkirjaga nr 2-1/23/395H otsustati: 1. Tunnistan vastavaks järgmiste pakkujate esitatud pakkumused, kuna need vastavad riigihanke alusdokumentides kehtestatud nõuetele: 1.1 TAMREX OHUTUSE OSAÜHING (10590451); 1.2 Bristol Trust OÜ (11699990) ja alltöövõtja, kelle näitajatele tuginetakse: MKU LIMITED (U19202UP2001PLC026027); 1.3 MKU GmbH (HRB 121400) ja alltöövõtja, kelle näitajatele tuginetakse: MKU LIMITED (U19202UP2001PLC026027). 2. Lükkan tagasi pakkuja DMI Capital OÜ (14258386) ja alltöövõtja, kelle näitajatele tuginetakse: Garanti Giyim Kompozit Teknolojileri Sanayi ve Ticaret A.S (2539), pakkumuse protokollis toodud põhjustel, millest pakkujat informeeritakse eraldi. 3. Tunnistan edukaks kõik punktis 1 vastavaks tunnistatud pakkumused esitanud pakkujad. 4. Käskkirjaga tehtud otsused teha pakkujatele teatavaks. Edukaks tunnistatud pakkujatega ei sõlmita lepingut enne riigihangete seaduse § 120 lg 2 sätestatud ooteaja möödumist. Käskkirjaga tehtud otsuste peale on õigus esitada vaidlustus, mis peab olema laekunud riigihangete vaidlustuskomisjonile riigihangete seaduses sätestatud korras. lugupidamisega Teadet saab lugeda registris hanke töölehel Teabevahetus - Sõnumid pakkujale. https://riigihanked.riik.ee/rhr-web/#/procurement/5261740/communication/message/775655 https://riigihanked.riik.ee/rhr-web/#/settings/users/my-notifications?notificationId=18395309 See on automaatteavitus. Palume sellele kirjale mitte vastata. 1 ________________________________ Käesolev e-kiri võib sisaldada asutusesiseseks kasutamiseks tunnistatud teavet. Kui te ei ole selle kirja adressaat, palun võtke ühendust saatjaga ning kustutage e-kiri arvutist. This e-mail may contain information which is classified for internal use. If you are not the intended recipient of this message, please notify the sender immediately and delete the message. -- Sven Pedari Project Manager DMI Capital PLC Phone +372 523 3562 2 Vaidlustuskomisjon Tartu mnt 85, Tallinn, 10115 [email protected] Esitatud e-kirjaga. 13. september 2023. a. Riigihange: Viitenumber 257906, Ballistilised kiivrid ja lisadetailid Vaidlustatud otsus: Riigi Kaitseinvesteeringute Keskuse peadirektori 06.09.2023 käskkiri nr 2-1/23/395H Vaidlustaja: DMI Capital OÜ, registrikood 14258386, aadress Rahe tn 23, 10618, Tallinn, e-post: [email protected] Vaidlustaja esindaja: vandeadvokaat Rando Maisvee, Advokaadibüroo MOSS Legal, Tatari 25, Tallinn 10116, telefon 5277506, e-post: [email protected] Hankija: Riigi Kaitseinvesteeringute Keskus, registrikood 70009764, aadress Järve tn 34a, 11314, Tallinn, e-post: [email protected] VAIDLUSTUS Tegemist on kaitse- ja julgeoleku sektoris rahvusvahelist piirmäära ületava etappideks jaotatud piiratud hankemenetlusega, millega kaasneb raamlepingu sõlmimine kuni viie pakkujaga ballistiliste kiivrite ja lisavarustuse tarnimiseks. All toodud põhjendustel, vaidlustaja, p a l u b: 1. Tunnistada riigihankes viitenumbriga 257906 kehtetuks Riigi Kaitseinvesteeringute Keskuse peadirektori 06.09.2023 käskkiri nr 2- 1/23/395H osaliselt, s.o käskkirja punkt: 1 osas, millega DMI Capital OÜ pakkumus jäeti vastavaks tunnistamata; 2 kogu ulatuses; 3 osas, millega jäeti DMI Capital OÜ pakkumus edukaks tunnistamata; 2. Mõista hankijalt välja riigilõiv ja kulud lepingulisele esindajale. 1. ASJAOLUD 1.1. Hankija teavitas vaidlustajat 06.09.2023 e-kirjaga peadirektori 06.09.2023 käskkirjaga nr 2-1/23/395H otsustest (Lisa 1), mille punktiga: 1) Tunnistati vastavaks järgmiste pakkujate esitatud pakkumused, kuna need vastavad riigihanke alusdokumentides kehtestatud nõuetele: 1.1. TAMREX OHUTUSE OSAÜHING; 1.2. Bristol Trust OÜ ja alltöövõtja, kelle Advokaadibüroo MOSS Legal OÜ | aadress: Tatari 25, 10116, Tallinn | www.moss.legal | e-post: [email protected] 2 näitajatele tuginetakse: MKU LIMITED; 1.3 MKU GmbH (HRB 121400) ja alltöövõtja, kelle näitajatele tuginetakse: MKU LIMITED; 2) Lükati tagasi vaidlustaja ja alltöövõtja, kelle näitajatele tuginetakse: Garanti Giyim Kompozit Teknolojileri Sanayi ve Ticaret A.S (2539), pakkumus (ref.) „protokollis toodud põhjustel, millest pakkujat informeeritakse eraldi"; 3) Tunnistati edukaks kõik punktis 1 vastavaks tunnistatud pakkumused esitanud pakkujad; 4) Otsustati teha otsus teatavaks pakkujatele ja teavitati, et edukaks tunnistatud pakkujatega ei sõlmita lepingut enne riigihangete seaduse § 120 lg 2 sätestatud ooteaja möödumist. 1.2. Hankija 07.09.2023 e-kirjaga (Lisa 2) selgitati, et vaidlustaja pakkumus tunnistati mittevastavaks, sest pakkumusega esitatud "Stanag 2920 V50 Test Report NIJ accredited Test Laboratory" (Lisa 3) kohaselt ei vasta testitud ja pakkumuses esitatud tooted hanke tehnilises kirjelduses sätestatud tingimusele ehk testitud kiivrite V50 oli alla 550 m/s. 2. VAIDLUSTUSE PÕHJENDUS 2.1. HD lisa 3 tehnilise kirjelduse p 1 kohaselt peab kiiver vastama ”NATO STANAG 2920 (või samaväärne), kus V50= 550 m/s või rohkem.”. Ülal viidatud testi (Lisa 3) lk 7 kirjeldatud kokkuvõtte kohaselt ületab eelviidatud arvnäitaja oluliselt tehnilises kirjelduses määratletud miinimumi, moodustades V50= 2299 jalga1/sekundis ehk V50= 700,74 m/s (2299 jalga = 700,7352 meetrit). 2.2. Võimalik põhjus, miks hankija leidis teisiti, võib avalduda ülal viidatud testi (Lisa 3) lk 11 kirjeldatus, kus ei tulistatud kiivrit, vaid klaasi meenutavat visiiri. Vaidlusaluses hankes aga visiiri ei hangita. 2.3. Kuivõrd pakutud kiiver vastab tehnilise kirjelduse p 1 toodud nõudele, välistab vaidlustatud otsus vaidlustaja õigust raamlepingut sõlmida ja selle tingimustel minikonkurssidel osaleda ning hankelepinguid sõlmida. Kirjeldatud tagajärg on vastuolus pakkujate võrdse kohtlemise ja konkurentsi efektiivse ärakasutamise põhimõtetega ega taga rahaliste vahendite säästlikku ja otstarbekat kasutamist. 3. MENETLUSE VORM 3.1. Vaidlustaja on nõus vaidlustuse läbivaatamisega kirjalikus menetluses. 1 https://et.wikipedia.org/wiki/Jalg_(pikkus%C3%BChik) Advokaadibüroo MOSS Legal OÜ | aadress: Tatari 25, 10116, Tallinn | www.moss.legal 3 Lisatud dokumentide nimekiri: Lisa 1 – 06.09.2023 e-kiri Lisa 2 – 07.09.2023 e-kiri Lisa 3 – Pakkumusega esitatud dokument "Stanag 2920 V50 Test Report NIJ accredited Test Laboratory" Lisa 4 – Volikiri Lisa 5 – Riigilõivu maksekorraldus. Lugupidamisega Rando Maisvee Vandeadvokaat Vaidlustaja lepinguline esindaja Advokaadibüroo MOSS Legal OÜ | aadress: Tatari 25, 10116, Tallinn | www.moss.legal Maksekorraldus NR 1048 Maksja NIMI Advokaadibüroo MOSS Legal OÜ ISIKUKOOD / REGISTRIKOOD 14853485 KONTONUMBER EE137700771004316139 MAKSJA PANGA NIMI, BIC KOOD JA AADRESS AS LHV Pank, LHVBEE22XXX, Tartu mnt. 2, 10145 Tallinn Saaja NIMI Rahandusministeerium ISIKUKOOD / REGISTRIKOOD KONTONUMBER EE777700771003813400 SAAJA PANGA NIMI, BIC KOOD JA AADRESS AS LHV Pank, LHVBEE22XXX, Tartu mnt. 2, 10145 Tallinn Makse KUUPÄEV 13.09.2023 SUMMA 1 280.00 EUR SUMMA SÕNADEGA üks tuhat kakssada kaheksakümmend EUR SELGITUS JA VIITENUMBER DMI Capital OÜ, reg. kood 14258386, vaidlustus riigihankes 257906 / 2900082126 PANGA KINNITUS TEENUSTASU 2023091349405275 Vastavalt hinnakirjale AS LHV PANK TARTU MNT 2, 10145 TALLINN 6800400 [email protected] LHV.EE KLIENDILEPINGU NR 20230913/01 LISA 1 “VOLIKIRI ÕIGUSTEENUSE OSUTAMISEKS“ Digiallkirjastamise kuupäeval DMI Capital OÜ , registrikood 14258386 , asukoha ga Harju maakond, Tallinn, Haabersti linnaosa, Rahe tn 23, 10618 (edaspidi Klient ), mida esindab juhatuse liige Meelis Järva , annab käesolevaga Advokaadibüroo MOSS Legal OÜ-le (edaspidi Advokaadibüroo ) ja vandeadvokaat Rando Maisvee’le volituse esindada Klienti alljärgneva õigusteenuse osutamisel (edaspidi käsund ): Õigusabi ja esindamine riigihankes nr 257906 vaidlustuse esitamisel ja selle menetlemisel . Ülalnäidatud eesmärkide saavutamiseks on Advokaadibürool ja tema advokaatidel õigus võtta tarvitusele kõiki õiguspäraseid meetmeid, mida nad peavad vajalikuks käsundi täitmiseks. Sealhulgas hõlmab esindus õigust esitada päringuid. Käesolev volikiri on kehtiv kuni käsundi täitmiseni või kliendilepingu ülesütlemiseni. Lugupidamisega Meelis Järva DMI Capital OÜ 11 March 2021 GARANTI Giyim Kompozit Teknolojileri Sanayi ve Ticaret A.S. Yozgat O.S.B. 66900 Yerkoy Yozgat, Turkey Attention: Mr. Mumtaz Ozbilen Subject: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Ticaret A.S., Armor Protection Ballistic Limit, V50 BL(P) and Ballistic Resistance Test: Job No. 3519‐028, Tested 17 February 2021, Purchase Order No. Signed quote Dear Mr. Ozbilen: Please find enclosed a report documenting the subject test series conducted by NTS‐Chesapeake Testing on 17 February 2021. This report includes a summary of the test as well as a detailed record for each armor sample tested. If you have any questions related to this test, please call Mr. Mike Hinder at 410 297 8154 or contact him via e‐mail at [email protected]. Sincerely, Chris Schueler General Manager, NTS‐Chesapeake Testing cdh Enc. a/s This report shall not be used to claim product certification, approval or endorsement. The results of the testing relate only to the samples submitted for testing. This test report shall not be interpreted as an endorsement by NTS-Chesapeake Testing as to the continued quality or performance of any items of the same or similar design. The information contained in this report may be subject to the provisions of the Export Administration Act (50 USC 2401 et seq.), the Export Administration Regulations (15 CFR 768-799), or the U.S. Arms Export Control Act (22USC 2778 et seq.) and the International Traffic in Arms Regulations (22 CFR 120-130). These statutes and regulations impose restrictions on import, export and transfer to foreign entities and persons, whether within the U.S. or abroad, of certain data and articles without approved licenses from the U.S. Department of State and/or the U.S. Department of Commerce. NTS‐Chesapeake Testing is an independent testing facility and has no affiliation with GARANTI Giyim Kompozit Teknolojileri Sanayi ve Ticaret A.S. 1 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION 4603B Compass Point Rd., Belcamp, MD 21017 v: 410.297.8154 f: 410.297.8160 POC: Mr. Mumtaz Ozbilen Purchase Order No.: Signed quote Test Date: 17 February 2021 Job No.: 3519-028 GARANTI Giyim Kompozit Teknolojileri Sanayi ve Ticaret A.S., Armor Protection Ballistic Limit, V50 BL(P) and Ballistic Resistance Test Prepared by: Craig Thomas Colleen Hallock NTS-Chesapeake Testing 4603B Compass Point Road Belcamp, MD 21017 2 March 2021 Further dissemination only as directed by GARANTI Giyim Kompozit Teknolojileri Sanayi ve Ticaret A.S., March 2021. This report shall not be used to claim product certification, approval or endorsement. The results of the testing relate only to the samples submitted for testing and are not representative of a complete model or lot. This test report shall not be interpreted as an endorsement by NTS-Chesapeake Testing as to the continued quality or performance of any items of the same or similar design. The information contained in this report may be subject to the provisions of the Export Administration Act (50 USC 2401 et seq.), the Export Administration Regulations (15 CFR 768-799), or the U.S. Arms Export Control Act (22USC 2778 et seq.) and the International Traffic in Arms Regulations (22 CFR 120-130). These statutes and regulations impose restrictions on import, export and transfer to foreign entities and persons, whether within the U.S. or abroad, of certain data and articles without approved licenses from the U.S. Department of State and/or the U.S. Department of Commerce. NTS-Chesapeake Testing is an independent testing facility and has no affiliation with GARANTI Giyim Kompozit Teknolojileri Sanayi ve Ticaret A.S. 2 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION POC: Mr. Mumtaz Ozbilen Purchase Order No.: Signed quote Test Date: 17 February 2021 Job No.: 3519-028 TABLE OF CONTENTS Page(s) DELIVERY LETTER………………………………………………………………………… 1 COVER PAGE………………………………………………………………………………... 2 TABLE OF CONTENTS……………………………………………………………………... 3 SECTION 1 INTRODUCTION……………………………………………………………… 4 SECTION 2 BALLISTIC LIMIT TEST, V50 BL(P).............................................................. 4 SUBSECTION 2.1 THREATS AND INSTRUMENTATION………………………………………… 4 SUBSECTION 2.2 DETAILS OF TEST (OBJECTIVE/STANDARDS/PROCEDURES)……………..... . 4 SUBSECTION 2.3 SUMMARY OF RESULTS…………………………………………………….. 5 TABLE 1 SUMMARY OF V50 BALLISTIC LIMIT TESTING .......……………………… 6 DATA SHEETS………………………………………………………………………………… .. 7-12 SECTION 3 BALLISTIC RESISTANCE TEST..................................................................... 13 SUBSECTION 3.1 THREATS AND INSTRUMENTATION…………………………………………13 SUBSECTION 3.2 DETAILS OF TEST (OBJECTIVE/STANDARD/PROCEDURES)………………... 13 SUBSECTION 3.3 SUMMARY OF RESULTS…………………………………………………..... 13 TABLE 2 SUMMARY OF BALLISTIC RESISTANCE TESTING …………………….…. 14 DATA SHEET…………………………………………………………………………………… 15-16 ATTACHMENT A (CALIBRATION DATA)………………………………………………………. 17 END OF REPORT ……………………………………………………………………………. 18 3 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION POC: Mr. Mumtaz Ozbilen Purchase Order No.: Signed quote Test Date: 17 February 2021 Job No.: 3519-028 1 Introduction GARANTI Giyim Kompozit Teknolojileri Sanayi ve Ticaret A.S. provided five helmets to NTS- Chesapeake Testing for testing on 17 February 2021. This is a two part report. The results of the ballistic limit, V50 BL(P) test are presented Section 2, and the results of the ballistic resistance test are presented in Section 3. 2 Ballistic Limit Test, V50 BL(P) Four samples were used for ballistic limit, V50 testing. 2.1 Threats and Instrumentation 2.1.1 Threats*  .22-cal., 17-grain fragment simulating projectiles (FSP) V2 *The projectiles were fired from a universal receiver which was fitted with the appropriate barrel and mounted on a NTS- Chesapeake Testing mount. The threat projectiles were required to have no greater than 5° total yaw. Projectile yaw was measured to ensure that the test impacts were within this constraint by placing a yaw card at the appropriate gun-to-target range during velocity verification shots. 2.1.2 Instrumentation Projectile velocity measurements were obtained using Oehler Research model No. 57 infrared screens with Y.I.S. Cowden Group Chrono-USB chronographs. Calibration data is provided in Attachment A. 2.2 Details of Test The objective of this test was to conduct a ballistic limit, V50 performance test on the helmets in accordance with Stanag 2920 Edition 3, dated 15 June 2015 and the customer’s request. Shot spacing between multiple impacts on a single helmet was in accordance with the referenced performance standard. Shots against the helmets were performed at 0.0 obliquity and ambient range temperature (68.4 F). For each shot, the target was clamped to a rigid test fixture. A piece of 0.508 mm thick (0.020 in) type 2024 T3 aluminum was mounted along the shotline, approximately 50.8 mm ±13 mm (2 in ±0.5 in) for Job No. 3519-028-1 and -3; and for Job No. 3519-028-2 approximately 152 mm ±13 mm (6 in ±0.5 in) behind the inside surface of the strike face, to verify complete penetrations. A complete penetration was scored only when the witness material was perforated (i.e., light was visible through the material). All firings were conducted at 15.000 ft from the target. The projectile velocities used for the test were in accordance with the customer’s request. Velocities for subsequent shots were based on the result of the previous shot. 4 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION POC: Mr. Mumtaz Ozbilen Purchase Order No.: Signed quote Test Date: 17 February 2021 Job No.: 3519-028 2.3 Summary of Results The results of the V50 ballistic limit testing are summarized in Table 1. The round-by-round ballistic data sheets and scatter plots for all testing performed are provided on the following pages. The following is a list of abbreviations used in the test data sheets: C = Complete penetration (same as CP). Gap = For V50 data, the difference in velocities between the highest partial penetration and the lowest complete penetration when the complete penetration occurs at a higher velocity than the partial penetration. HP = For V50 data, the highest velocity at which a partial penetration occurred. LC = For V50 data, the lowest velocity at which a complete penetration occurred. P = Partial penetration (same as PP). ROR = Range of results; for V50 data, difference between the highest and lowest velocities. V50 = Statistical velocity at which the threat defeats the armor 50% of the time. RMR = Range of mixed results; for V50 data, the difference in velocities between the highest partial penetration and the lowest complete penetration when the partial penetration occurs at a higher velocity than the complete penetration. Yes = Round was used in calculating a V50 or an approximate V50. No = Round was not used in calculating a V50 or an approximate V50. 5 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION POC: Mr. Mumtaz Ozbilen Purchase Order No.: Signed quote Test Date: 17 February 2021 Job No.: 3519-028 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. Table 1. Summary of V50 Ballistic Limit Test Results Ballistic Limit Data PROPRIETARY INFORMATION Job Sample Target No. of No. No. Size Weight Threat Obliq. V50 Points RMR GAP ROR (lbs) (deg) (ft/s) (ft/s) (ft/s) (ft/s) .22-cal., 3519-028-1 Helmet-17gr Large 2.80 0.0 2299 6 155 NA 168 6 of 18 17-grain FSP V2 .22-cal., 3519-028-2 Nape-17gr 6.00 x 4.00 0.46 0.0 2013 6 14 NA 86 17-grain FSP V2 .22-cal., 3519-028-3 Visor-17gr NA 0.65 0.0 868 6 37 NA 97 17-grain FSP V2 6 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION PROTECTION BALLISTIC LIMIT TEST, V50 BL(P) NTS-Chesapeake Testing Client: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Tic Job No.: 3519-028-1 4603B Compass Point Road Test Date: 2/17/2021 Belcamp, MD 21017 Page 1 of 2 Test Panel Description: Helmet. Manufacturer: GARANTI Giyim Sample No.: Helmet-17gr Size: Large Weight: 2.80 lbs Date Received: 2/12/2021 Avg. Thick: 0.313 in Plies/Laminates: NA Via: FedEx Thickness: 0.321 in; 0.321 in; Required BL(P): NA Returned: FedEx 0.310 in; 0.299 in Setup Shot Spacing: Stanag 2920 Edition 3 Primary Vel. Screens (ft): 5.000, 5.333, Range No.: 2 Witness Panel: 0.02 in 2024-T3 Aluminum 9.667, 10.000 Temp: 68.4 F Backing Material: NA Primary Vel. Location (ft): 7.500 BP: 30.7 inHg Condition: Ambient Range to Target (ft): 15.000 RH: 33.6% Target to Witness (in): 2.000 Barrel/Gun: Test Barrel Gunner: M. Skrocki Recorder: Bret DeMond Ammunition Projectile Lot No. Powder (1) .22-cal., 17-grain FSP V2 17120320 Bullseye Applicable Standards or Procedures (1) Stanag 2920 Edition 3, dated 15 June 2015 (2) Customer request Shot Powder/ Avg. Striking Include No. Seating Weight Time 1 Vel. 1 Time 2 Vel. 2 Vel. Vel. Result in V50 Obliq. Footnotes (gr) (µs) (ft/s) (µs) (ft/s) (ft/s) (ft/s) () 1 8.4 17.0 2194 2279 1901 2280 2279 2182 P No 0.0 (a) 2 9.3 17.0 2057 2431 1779 2436 2433 2329 P Yes 0.0 (b) 3 10.0 17.0 1986 2518 1720 2519 2519 2411 C No 0.0 (c) 4 9.6 17.0 1986 2518 1720 2519 2519 2411 C No 0.0 (d) 5 9.4 17.0 2098 2383 1818 2384 2383 2282 C Yes 0.0 (e) 6 9.2 17.0 2184 2289 1891 2292 2290 2193 C Yes 0.0 (a) 7 9.0 17.0 2135 2342 1849 2344 2343 2243 P No 0.0 (b) 8 9.3 17.0 2098 2383 1815 2388 2385 2283 P Yes 0.0 (c) 9 9.5 17.0 2030 2463 1754 2471 2467 2361 C Yes 0.0 (d) 10 9.3 17.0 2040 2451 1766 2454 2452 2348 P Yes 0.0 (e) Remarks: V50 Summary: Requested starting velocity: 2233 ft/s. No. Points: 3 and 3 V50: 2299 ft/s High Partial: 2348 ft/s Footnotes: Low Complete: 2193 ft/s (a) Crown Range of Results (ROR): 168 ft/s (b) Front Range of Mix Results (RMR): 155 ft/s (c) Left Gap: NA (d) Back (e) Right 7 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION PROTECTION BALLISTIC LIMIT TEST, V50 BL(P) NTS-Chesapeake Testing Client: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Tic Job No.: 3519-028-1 4603B Compass Point Road Test Date: 2/17/2021 Belcamp, MD 21017 Page 2 of 2 Manufacturer: GARANTI Giyim Sample No.: Helmet-17gr V50 Summary: No. Points: 3 and 3 V50: 2299 ft/s High Partial: 2348 ft/s Low Complete: 2193 ft/s Range of Results (ROR): 168 ft/s Range of Mix Results (RMR): 155 ft/s Gap: NA 8 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION PROTECTION BALLISTIC LIMIT TEST, V50 BL(P) NTS-Chesapeake Testing Client: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Tic Job No.: 3519-028-2 4603B Compass Point Road Test Date: 2/17/2021 Belcamp, MD 21017 Page 1 of 2 Test Panel Description: Nape. Manufacturer: GARANTI Giyim Sample No.: Nape-17gr Size: 6.00 x 4.00 in Weight: 0.46 lbs Date Received: 2/12/2021 Avg. Thick: NA Plies/Laminates: NA Via: FedEx Thickness: NA Required BL(P): NA Returned: FedEx Setup Shot Spacing: Stanag 2920 Edition 3 Primary Vel. Screens (ft): 5.000, 5.333, Range No.: 2 Witness Panel: 0.02 in 2024-T3 Aluminum 9.667, 10.000 Temp: 68.4 F Backing Material: NA Primary Vel. Location (ft): 7.500 BP: 30.8 inHg Condition: Ambient Range to Target (ft): 15.000 RH: 32.9% Target to Witness (in): 6.000 Barrel/Gun: Test Barrel Gunner: M. Skrocki Recorder: Bret DeMond Ammunition Projectile Lot No. Powder (1) .22-cal., 17-grain FSP V2 17120320 Bullseye Applicable Standards or Procedures (1) Stanag 2920 Edition 3, dated 15 June 2015 (2) Customer request Shot Powder/ Avg. Striking Include No. Seating Weight Time 1 Vel. 1 Time 2 Vel. 2 Vel. Vel. Result in V50 Obliq. Footnotes (gr) (µs) (ft/s) (µs) (ft/s) (ft/s) (ft/s) () 1 6.8 17.0 2543 1966 2201 1969 1967 1884 P No 0.0 2 7.6 17.0 2330 2146 2015 2151 2148 2056 C Yes 0.0 3 7.1 17.0 2489 2009 2155 2011 2010 1924 P No 0.0 4 7.4 17.0 2372 2108 2054 2110 2109 2019 P Yes 0.0 5 7.6 17.0 2318 2157 2006 2160 2159 2066 C No 0.0 6 7.5 17.0 2364 2115 2047 2117 2116 2026 C Yes 0.0 7 7.3 17.0 2389 2093 2067 2096 2095 2005 C Yes 0.0 8 7.1 17.0 2430 2058 2106 2058 2058 1970 P Yes 0.0 9 7.3 17.0 2499 2001 2162 2004 2003 1917 P No 0.0 10 7.5 17.0 2391 2091 2069 2094 2093 2004 P Yes 0.0 Remarks: V50 Summary: Requested starting velocity: 1905 ft/s. No. Points: 3 and 3 V50: 2013 ft/s High Partial: 2019 ft/s Footnotes: Low Complete: 2005 ft/s Range of Results (ROR): 86 ft/s Range of Mix Results (RMR): 14 ft/s Gap: NA 9 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION PROTECTION BALLISTIC LIMIT TEST, V50 BL(P) NTS-Chesapeake Testing Client: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Tic Job No.: 3519-028-2 4603B Compass Point Road Test Date: 2/17/2021 Belcamp, MD 21017 Page 2 of 2 Manufacturer: GARANTI Giyim Sample No.: Nape-17gr V50 Summary: No. Points: 3 and 3 V50: 2013 ft/s High Partial: 2019 ft/s Low Complete: 2005 ft/s Range of Results (ROR): 86 ft/s Range of Mix Results (RMR): 14 ft/s Gap: NA 10 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION PROTECTION BALLISTIC LIMIT TEST, V50 BL(P) NTS-Chesapeake Testing Client: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Tic Job No.: 3519-028-3 4603B Compass Point Road Test Date: 2/17/2021 Belcamp, MD 21017 Page 1 of 2 Test Panel Description: Visor. Manufacturer: GARANTI Giyim Sample No.: Visor-17gr Size: NA Weight: 0.65 lb Date Received: 2/12/2021 Avg. Thick: 0.169 in Plies/Laminates: NA Via: FedEx Thickness: 0.177 in; 0.155 in; Required BL(P): NA Returned: FedEx 0.173 in; 0.172 in Setup Shot Spacing: Stanag 2920 Edition 3 Primary Vel. Screens (ft): 5.000, 5.333, Range No.: 2 Witness Panel: 0.02 in 2024-T3 Aluminum 9.667, 10.000 Temp: 68.4 F Backing Material: NA Primary Vel. Location (ft): 7.500 BP: 30.7 inHg Condition: Ambient Range to Target (ft): 15.000 RH: 32.9% Target to Witness (in): 2.000 Barrel/Gun: Test Barrel Gunner: M. Skrocki Recorder: Bret DeMond Ammunition Projectile Lot No. Powder (1) .22-cal., 17-grain FSP V2 17120320 Gray Applicable Standards or Procedures (1) Stanag 2920 Edition 3, dated 15 June 2015 (2) Customer request Shot Powder/ Avg. Striking Include No. Seating Weight Time 1 Vel. 1 Time 2 Vel. 2 Vel. Vel. Result in V50 Obliq. Footnotes (gr) (µs) (ft/s) (µs) (ft/s) (ft/s) (ft/s) () 1 10 17.0 4618 1083 3998 1084 1083 1045 C No 0.0 2 13 17.0 4867 1027 4208 1030 1029 993 C No 0.0 3 17 17.0 5936 842 5135 844 843 818 P Yes 0.0 4 15 17.0 5294 944 4581 946 945 915 C Yes 0.0 5 16 17.0 5772 866 4994 868 867 841 P Yes 0.0 6 15 17.0 5487 911 4745 913 912 884 P Yes 0.0 7 14 17.0 5125 976 4435 977 976 944 C No 0.0 8 15 17.0 5370 931 4647 933 932 902 C Yes 0.0 9 16 17.0 5728 873 4959 874 873 847 C Yes 0.0 Remarks: V50 Summary: Requested starting velocity: 920 ft/s. No. Points: 3 and 3 V50: 868 ft/s High Partial: 884 ft/s Footnotes: Low Complete: 847 ft/s Range of Results (ROR): 97 ft/s Range of Mix Results (RMR): 37 ft/s Gap: NA 11 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION PROTECTION BALLISTIC LIMIT TEST, V50 BL(P) NTS-Chesapeake Testing Client: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Tic Job No.: 3519-028-3 4603B Compass Point Road Test Date: 2/17/2021 Belcamp, MD 21017 Page 2 of 2 Manufacturer: GARANTI Giyim Sample No.: Visor-17gr V50 Summary: No. Points: 3 and 3 V50: 868 ft/s High Partial: 884 ft/s Low Complete: 847 ft/s Range of Results (ROR): 97 ft/s Range of Mix Results (RMR): 37 ft/s Gap: NA 12 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION POC: Mr. Mumtaz Ozbilen Purchase Order No.: Signed quote Test Date: 17 February 2021 Job No.: 3519-028 3 Ballistic Resistance Test Two helmets were used for ballistic resistance testing. 3.1 Threats and Instrumentation 3.1.1 Threats*  .44-mag., 240-grain semi jacketed hollow point (SJHP) projectiles  .357-cal., 125-grain SIG full metal jacket flat nosed (FMJ FN) projectiles *All projectiles were fired from a universal receiver which was fitted with the appropriate barrel and mounted on a NTS- Chesapeake Testing mount. *The threat projectiles were required to have no greater than 3 total yaw. Projectile yaw was measured to ensure that the test impacts were within this constraint by placing a yaw card at the appropriate gun-to-target range during velocity verification shots. 3.1.2 Instrumentation Projectile velocity measurements were obtained using Oehler Research model No. 57 infrared screens with Y.I.S. Cowden Group Chrono-USB chronographs. A digital caliper was used to measure the post-impact deformation observed in the head form clay. Calibration data is provided in Attachment A. 3.2 Details of Test The objective of this test was to conduct a ballistic resistance test on the helmets in accordance with NIJ-STD-0101.06 Level IIIA (Modified) and the customer’s request. A single shot was fired at each sample in accordance with the referenced performance standard. Shots against the helmets were performed at 0.0 obliquity and ambient range temperature (68.4 F). For each shot, the target was strapped to a 5.5-in clay/plywood backing that was clamped to a rigid test fixture. All firings were conducted at 17.200 ft from the target. The projectile velocities used for the test were in accordance with the referenced performance standards. 3.3 Summary of Results The results of the ballistic resistance test are shown in Table 2. The round-by-round ballistic data sheets for all testing performed are presented on the following pages. 13 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION POC: Mr. Mumtaz Ozbilen Purchase Order No.: Signed quote Test Date: 17 February 2021 Job No.: 3519-028 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. Table 2. Summary of Ballistic Resistance Test Results PROPRIETARY INFORMATION Job Sample Target Shot Penetration Data No. No. Size Weight Threat Obliq. No. Velocity Result Def. (in) (lbs) (deg) (ft/s) (mm) 14 of 18 .44-mag., 3519-028-A Nape-.44 Mag 6.00 x 4.00 0.44 0.0 1 1431 None 59.4 240-grain SJHP .357-cal., 3519-028-B Nape-.357 Sig 6.00 x 4.00 0.45 0.0 1 1491 None 33.4 125-grain SIG FMJ FN BALLISTIC RESISTANCE TEST NTS-Chesapeake Testing Client: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Tic 4603B Compass Point Road Job No.: 3519-028-A Belcamp, MD 21017 Test Date: 2/17/2021 Test Panel Description: Nape. Manufacturer: GARANTI Giyim Sample No.: Nape-.44 Mag Size: 6.00 x 4.00 in Weight: 0.44 lbs Date Received: 2/12/2021 Avg. Thick: NA Plies/Laminates: NA Via: FedEx Thickness: NA Returned: FedEx Setup Shot Spacing: NIJ-STD-0101.06 Level IIIA Primary Vel. Screens (ft): 6.500, 6.833, Range No.: 2 Witness Panel: Clay 11.166, 11.500 Temp: 68.4 F Backing Material: 5.5-in clay/plywood Primary Vel. Location (ft): 9.000 BP: 30.9 inHg Condition: Ambient Range to Target (ft): 17.200 RH: 34.2% Target to Witness (in): 0.000 Barrel/Gun: Test Barrel Gunner: M. Skrocki Recorder: Bret DeMond Ammunition Projectile Lot No. Powder (1) .44-mag., 240-grain SJHP Speer B02X Accurate No. 5 Applicable Standards or Procedures Clay Drop 1 - Drop Time: 8:25 PM; Block No. 19; Temp: 92.7°F; Drop Depths: 17.7mm,17.1mm,18.1mm,17.7mm,17.1mm (1) NIJ-STD-0101.06 Level IIIA (Modified) (2) Customer request Shot Avg. No. Ammo Weight Time 1 Vel. 1 Time 2 Vel. 2 Vel. Penetration Deformation Obliq. Footnotes (gr) (µs) (ft/s) (µs) (ft/s) (ft/s) (mm) () 1 1 240.1 3497 1430 3026 1432 1431 None 59.4 0.0 Remarks: Required velocity: 1430 ± 30 ft/s Footnotes: 15 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION BALLISTIC RESISTANCE TEST NTS-Chesapeake Testing Client: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Tic 4603B Compass Point Road Job No.: 3519-028-B Belcamp, MD 21017 Test Date: 2/17/2021 Test Panel Description: Nape. Manufacturer: GARANTI Giyim Sample No.: Nape-.357 Sig Size: 6.00 x 4.00 in Weight: 0.45 lbs Date Received: 2/12/2021 Avg. Thick: NA Plies/Laminates: NA Via: FedEx Thickness: NA Returned: FedEx Setup Shot Spacing: NIJ-STD-0101.06 Level IIIA Primary Vel. Screens (ft): 6.500, 6.833, Range No.: 2 Witness Panel: Clay 11.166, 11.500 Temp: 68.4 F Backing Material: 5.5-in clay/plywood Primary Vel. Location (ft): 9.000 BP: 30.8 inHg Condition: Ambient Range to Target (ft): 17.200 RH: 34.6% Target to Witness (in): 0.000 Barrel/Gun: Test Barrel Gunner: M. Skrocki Recorder: Bret DeMond Ammunition Projectile Lot No. Powder (1) .357-cal., 125-grain SIG FMJ FN Speer A27R Accurate No. 2 Applicable Standards or Procedures Clay Drop 1 - Drop Time: 8:25 PM; Block No. 19; Temp: 92.7°F; Drop Depths: 17.7mm,17.1mm,18.1mm,17.7mm,17.1mm (1) NIJ-STD-0101.06 Level IIIA (Modified) (2) Customer request Shot Avg. No. Ammo Weight Time 1 Vel. 1 Time 2 Vel. 2 Vel. Penetration Deformation Obliq. Footnotes (gr) (µs) (ft/s) (µs) (ft/s) (ft/s) (mm) () 1 1 124.3 3356 1490 2904 1492 1491 None 33.4 0.0 Remarks: Required velocity: 1470 ± 30 ft/s Footnotes: 16 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION POC: Mr. Mumtaz Ozbilen Purchase Order No.: Signed quote Test Date: 17 February 2021 Job No.: 3519-028 ATTACHMENT A CALIBRATION DATA 3519-028 Job Number: GARANTI Giyim Kompozit Teknolojileri Sanayi ve Customer: Tic Date: 2/17/2021 Range: 2 Range Lead: Bret DeMond Range Equipment Serial Number NTS I.D. # Cal. Date Due Date Lead Initials Chronograph 1 103 WC027146 8/14/2020 8/14/2021 BD Chronograph 2 113 WC067023 8/14/2020 8/14/2021 BD Powder Scale A06233026 WC060532 12/7/2020 12/7/2021 BD Floor Scale 25459071 WC060652 12/9/2019 12/9/2021 BD 7/1/2019 7/1/2021 BD 100 ft. Tape Measure 103 WC060412 25 ft. Tape Measure WC074972 WC074972 8/24/2020 8/24/2021 BD Thermometer 192140234 WC067353 4/27/2019 4/27/2021 BD BFD Tool 19/090059 WC075101 12/15/2020 12/15/2021 BD BFD Bridge 12/450046 WC064227 12/9/2020 12/9/2021 BD Angle Block 840 WC027021 5/19/2020 5/19/2021 BD Temp/Humidity Monitor 200597950 WC075050 10/06/2020 10/06/2022 BD 17 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION POC: Mr. Mumtaz Ozbilen Purchase Order No.: Signed quote Test Date: 17 February 2021 Job No.: 3519-028 END OF REPORT 18 of 18 GARANTI GIYIM KOMPOZIT TEKNOLOJILERI SANAYI VE TICARET A.S. PROPRIETARY INFORMATION Rando Maisvee | MOSS Saatja: Sven Pedari <[email protected]> Saatmisaeg: kolmapäev, 13. september 2023 18:04 Adressaat: Rando Maisvee | MOSS Teema: Fwd: Uus sõnum riigihankes 257906 -------- Esialgne kiri -------- Pealkiri: Uus sõnum riigihankes 257906 Kuupäev: 07.09.2023 13:46 Saatja: Riigihangete register <[email protected]> Saaja: <[email protected]> Teile on riigihangete registris uus teade: Riigihanke 257906 "Ballistilised kiivrid ja lisadetailid" raames on saadetud teade: Tere selgituseks pakkumuse tagasi lükkamise kohta teatame, et tehnilise kirjelduse punktis 1 on sätestatud, et kiiver peab vastama NATO STANAG 2920 testimise strandardile (või samaväärne), kus V50= 550 m/s või rohkem. Pakkuja esitatud "Stanag 2920 V50 Test Report NIJ accredited Test Laboratory" kohaselt ei vasta testitud ja pakkumuses esitatud tooted hanke tehnilises kirjelduses sätestatud tingimusele ehk testitud kiivrite V50 oli alla 550 m/s. Seetõttu tunnistati pakkumus mittevastavaks. lugupidamisega Teadet saab lugeda registris hanke töölehel Teabevahetus - Sõnumid pakkujale. https://riigihanked.riik.ee/rhr-web/#/procurement/5261740/communication/message/775870 https://riigihanked.riik.ee/rhr-web/#/settings/users/my-notifications?notificationId=18402082 See on automaatteavitus. Palume sellele kirjale mitte vastata. ________________________________ Käesolev e-kiri võib sisaldada asutusesiseseks kasutamiseks tunnistatud teavet. Kui te ei ole selle kirja adressaat, palun võtke ühendust saatjaga ning kustutage e-kiri arvutist. This e-mail may contain information which is classified for internal use. If you are not the intended recipient of this message, please notify the sender immediately and delete the message. -- Sven Pedari Project Manager DMI Capital PLC Phone +372 523 3562 1
Allikas: Rahandusministeerium dokumendiregister →
dokumendiregister.eeAsutusedEesti avalike dokumendiregistrite otsing · nimistu.ee andmetel