Riigihangete vaidlustuskomisjon
Tartu mnt 85, Tallinn, Harju maakond, 10115
E-post:
[email protected] 27. juuli 2023
Riigihanke viitenumber: 266125
Vaidlustuse esitaja: ühispakkujad Netbits OÜ ja Proekspert AS
Registrikoodid 16498137 ja 10331577
Sõpruse pst 157, Tallinn 13417
Tel: +372 5028016
E-post:
[email protected]
Volitatud esindaja: Ove Tüksammel
Netbits OÜ juhatuse liige
E-post:
[email protected]
Hankija: Eesti Kunstiakadeemia
Registrikood: 74000624
Põhja pst 7, 10412 Tallinn
Tel: +372 6267301
E-post:
[email protected]
Riigihanke eest vastutav isik: AndresTammsaar
Haldus- ja finantsdirektor
E-post:
[email protected]
Kolmas isik: Reminet OÜ
Registrikood: 10447156
Iru tee 5, Iru küla Jõelähtme vald, Harjumaa 74206
Tel: +372 5106455
E-post:
[email protected]
VAIDLUSTUS
Riigihankes “Ruumikasutuse ja sisekliima monitooringu süsteem energiatarbimise
optimeerimiseks”
RESOLUTSIOON:
1. Tunnistada kehtetuks riigihanke “Ruumikasutuse ja sisekliima monitooringu
süsteem energiatarbimise optimeerimiseks” (viitenumber 266125) menetluses
Eesti Kunstiakadeemia otsuse 17. juuli 2023 osa 1, millega tunnistati vastavaks
Reminet OÜ (regitrikood 10447156) pakkumus;
2. Mõista ühispakkujate Netbits OÜ ja Proekspert AS kasuks välja menetluskulud.
I. ASJAOLUD JA MENETLUSE SENINE KÄIK
1. 13. juunil 2023 avaldas Eesti Kunstiakadeemia (Hankija) riigihangete registris
pakkumiskutse (lisa1), paludes esitada pakkumus hankemenetlusega riigihankele Eesti
Kunstiakadeemiale süsteemi loomiseks, et monitoorida õpperuumide kasutamist ja
täituvust eesmärgiga saavutada märgatav energiasääst ja sisekliima paranemine.
2. Tähtpäevaks (28. juuni 2023) esitasid riigihanke pakkumused Reminet OÜ (Kolmas
isik/Pakkuja) ning ühispakkujad Netbits OÜ ja Proekspert AS (Vaidlustaja)
3. Pakkuja pakkumus tunnistati Hankija otsusega 17. juuli 2023 (lisa 3) vastavaks, kuna
pakkumus vastas Hankija hinnangul riigihankes sätestatud tingimustele. Sama otsusega
tunnistati RHS § 114 lg 2 alusel mittevastavaks ja lükati tagasi Vaidlustaja pakkumus,
mis ei vastanud Hankija hinnangul riigihanke alusdokumentides esitatud tingimustele
(lisa 2).
4. Pakkuja poolt pakutav kliimaanduri Elsys ERS CO2 tehniline kirjeldus (lisa 4) ei vasta
riigihanke alusdokumentides esitatud tingimustele.
5. Vaidlustaja poolt pakutav kliimaandur Milesight AM307 on samaväärne Pakkuja poolt
pakutava kliimaanduriga Elsys ERS CO2.
6. Vaidlustaja sai otsuse kätte 17. juuli 2023, järelikult on käesolev vaidlustus esitatud
tähtaegselt.
7. Vaidlustaja leiab, et on rikutud tema subjektiivseid õigusi.
8. Vaidlustaja ei nõustu Hankija otsuses esitatud väidetega ja leiab, et Pakkuja pakkumus
on tunnistatud vastavaks põhjendamatult. Eeltoodud põhjusel esitab Vaidlustaja
käesoleva vaidlustuse.
II. VAIDLUSTUSE PÕHJENDUSED
Pakkuja pakkumuse mittevastavusest
9. Hankijal oli nõutud kliimaanduri puhul CO2 mõõtmisel ulatus vähemalt 0-10000 ppm,
täpsus vähemalt ±50 ppm / ±3% loetust. Pakkuja poolt pakutava kliimaanduri Elsys ERS
CO2 laiendatud ulatus on küll 0-10000 ppm, kuid seda ainult täpsusega ± 10%.
Täpsus ± 50 ppm / ± 3% loetust kehtib ainult kalibreeritud ulatuse 0-2000 ppm kohta
(lisa 4). See tähendab, et pakutava CO2 anduri täpsus ja ulatus ei vasta hanke
alusdokumentides esitatud tingimustele, kuna pakkuja poolt pakutava anduri täpsus ja
ulatus on väiksemad hankija nõutust (täpsus ± 10% loetust on väiksem kui ±50 ppm /
±3% loetust ning kalibreeritud ulatus 0-2000 ppm on väiksem kui 0-10000 ppm).
Eeltoodust tulenevalt on Hankija eksinud pakkumuse vastavaks tunnistamisel, kuna
pakkumus ei vasta riigihanke alusdokumentides esitatud tingimustele.
10. Leiame, et Hankija 17. juuli 2022 otsus ei ole kooskõlastatud objektiivselt ja kooskõlas
seadusega. Hankija poolt tuvastatud asjaolud ei vasta tegelikkusele, mistõttu tuleb
viidatud otsus tühistada.
Pakutud seadmete samaväärsusest
11. Pakkuja poolt pakutava kliimanduri Elsys ERS CO2, CO2 mõõteulatus täpsuse ± 50 ppm
/ ± 3% loetust juures on 0-2000 ppm. Vaidlustaja poolt pakutava kliimaanduri Milesight
AM307 CO2 mõõteulatus täpsuse ±30 ppm / ±3 % loetust juures on 400 - 5000 ppm (lisa
5). (Täpsus ±30 ppm on suurem, kui täpsus ± 50 ppm, ulatus 400-5000 on suurem kui
ulatus 0-2000). Milesight AM307 CO2 mõõteulatust on võimalik tootjapoolse püsivara
uuendusega laiendada 0-10000, täpsusega ± 10%.
Pakkuja poolt pakutava kliimanduri Elsys ERS CO2 resolutsioon suhtelise niiskuse
mõõtmisel on 0.1% RH. Vaidlustaja poolt pakutava kliimaanduri Milesight AM307
vaikimisi resolutsioon suhtelise niiskuse mõõtmisel on 0.5% RH, kuid seda on võimalik
tõsta tootja poolse püsivara uuendusega tasemele 0.1% RH. Mõlemad pakutavad
seadmed kasutavad temperatuuri ja niiskuse mõõtmisel samaväärseid sama tootja
sensoreid. Elsys ERS CO2 kasutab sensorit Sensirion SHT40 ning Milesight AM307
kasutab sensorit Sensirion SHT41 (lisa 6).
Vaidlustaja subjektiivsete õiguste rikkumisest
12. Kuigi Hankija on Vaidlustaja pakkumuse õiguspäraselt tagasi lükanud, pole praegusel
juhul võimalik üheselt järeldada, et Kolmanda isiku pakkumuse vastavaks ja edukaks
tunnistamise otsuste õiguspärasus ei omaks Vaidlustaja õiguslikult kaitstud huvidele
mingisugust mõju. Praegusel juhul on tegemist olukorraga, kus pakkumuse esitasid kaks
isikut. Kui mõlematel isikutel pole võimalik vaidlusaluses hankemenetluses hankelepingu
sõlmimiseni jõuda ning Hankija pole loobunud soovist osta ruumikasutuse ja sisekliima
monitooringu süsteem, võib esineda tõenäosus, et Hankija korraldab sama või sarnaste
esemete ostmiseks uue hankemenetluse. Uues hankemenetluses oleks võimalik
osaleda ka Vaidlustajal (vt TlnRnKo 22.04.2022, 3-22-127, p 14).
III. MENETLUSLIKUD AVALDUSED
13. Allakirjutanu kinnitab esindusõiguse olemasolu.
14. Vaidlustaja on nõus asja läbivaatamisega kirjalikus menetluses.
15. RHS § 186 sätestab, et vaidlustuskomisjonile vaidlustuse ja kahju hüvitamise taotluse
esitamisel tasutakse riigilõivu riigilõivuseaduses §-s 258 sätestatud korras.RLS § 258 lg
1 p 1 sätestab, et riigihanke vaidlustuse esitamisel tasutakse riigilõivu: 640 eurot, kui
riigihanke eeldatav maksumus on rahvusvahelisest piirmäärast väiksem. Vaidlustaja on
vastavas määras riigilõivu tasunud (lisa 7).
Lisad:
1. Pakkumiskutse;
2. Tehniline kirjeldus;
3. Hankija otsus 17. juuli 2023;
4. Pakkuja pakutava kliimaanduri Elsys ERS CO2 tootja poolne tehniline spetsifikatsioon ja selle
tõlge;
5. Vaidlustaja pakutava kliimaanduri Milesight AM307 tootja poolne tehniline spetsifikatsioon ja
selle tõlge;
6. Sensirion SHT4x niiskuse ja temperatuuri sensori andmeleht ja selle tõlge
7. Riigilõivu tasumist tõendav dokument.
Lugupidamisega
/digitaalselt allkirjastatud/
Ove Tüksammel
Netbits OÜ, juhatuse liige
RIIGIHANKE VIITENUMBER 266125
Ruumikasutuse ja sisekliima monitooringu süsteem energiatarbimise optimeerimiseks
Avatud hankemenetlus
Hankedokument
Eesti Kunstiakadeemia
2023
1
Ruumikasutuse ja sisekliima monitooringu süsteem energiatarbimise optimeerimiseks
1. Riigihanke nimetus ja iseloomustus
Kutsume Teid esitama pakkumust riigihanke alusdokumentides toodud tingimustel Eesti
Kunstiakadeemiale süsteemi loomiseks, et monitoorida oma õpperuumide kasutamist ja täituvust
eesmärgiga saavutada märgatav energiasääst ja sisekliima paranemine. Täpsem objekti kirjeldus
on toodud hankedokumendi lisades.
Riigihange ei ole ühe menetluse raames osadeks jagatud, kuna tegemist on ühe tervikliku
süsteemiga, mis ei ole osadeks jagatav.
2. Hankija:
Eesti Kunstiakadeemia
Põhja pst 7, 10412 Tallinn
Eesti Vabariik
3. Informatsioon riigihanke alusdokumentide kohta
3.1. Riigihanke alusdokumentideks (edaspidi lühendatult nimetatud ka „RA“) on kogu hankija poolt
avalikustatud käesoleva riigihankega seonduv dokumentatsioon, sealhulgas hanketeade, käesolev
hankedokument koos oma lisadega, riigihangete registris käesoleva riigihanke kohta avalikustatud
dokumendid jms.
3.2. Hanke alusdokumentide sisu kohta saab selgitusi kirjalikul pöördumisel hankija poole läbi
riigihangete registri.
3.3. Selgitustaotlused palume esitada aegsasti, kuna tulenevalt RHS § 46 lg 2 ei ole hankija
kohustatud selgitustaotlusele vastama, kui selgitustaotluse hankijale laekumise ja pakkumuste
esitamise tähtpäeva vahele ei jää vähemalt kuut päeva.
3.4. Hankija edastab selgitused riigihangete registris riigihanke juurde osalejana registreeritud
isikutele riigihangete registri kaudu. Hankemenetluse käigus selgituste saamiseks tuleb huvitatud
isikul end riigihangete registris riigihanke juurde riigihankes osalejana/huvitatud isikuna
registreerida.
3.5. Iga viidet, mille hankija teeb riigihanke alusdokumentides mõnele RHS-i § 88 lõikes 2 nimetatud
alusele (standardile, tehnilisele tunnustusele, tehnilisele kontrollisüsteemile vms), tuleb lugeda
selliselt, et see on täiendatud märkega „või sellega samaväärne“. Iga viidet, mille hankija teeb
riigihanke alusdokumentides ostuallikale, protsessile, kaubamärgile, patendile, tüübile, päritolule,
tootmisviisile, märgisele või vastavushindamisasutuse väljastatud katsearuandele või tõendile,
tuleb lugeda selliselt, et see on täiendatud märkega „või sellega samaväärne“ (RHS § 88 lg-d 5-6,
§ 89 lg 2, 114 lg-d 5-7).
Hankija aktsepteerib objektiivsetel põhjustel muid asjakohaseid tõendeid, kui pakkuja tõendab
hankijale vastuvõetaval viisil, et pakutav asi, teenus või ehitustöö vastab konkreetse märgise või
hankija esitatud nõuetele, välja arvatud juhul, kui hankija nõutud märgis, samaväärne märgis või
konkreetse või samaväärse vastavushindamisasutuse väljastatud katsearuanne või muu tõend on
seaduse alusel eelduseks asja, teenuse või ehitustöö pakkumiseks turul (RHS § 114 lg 7)
3.6. Hankija ei vastuta e-posti side ja riigihangete registri toimimise eest.
3.7. Hankedokumendi lisadeks on:
Lisa 1- Tehniline kirjeldus
Lisa 2 - Lepingu projekt
Lisa 3 – Monitooritavate ruumide nimekiri
Lisa 4 – Pakkumuse maksumuse lahtikirjutus
4. Pakkumuse esitamine
4.1. Hankemenetlus viiakse läbi e-riigihangete keskkonnas (edaspidi nimetatuna ka e-RHR) e-
hankena.
4.2. Pakkumuse koostamisel tuleb lähtuda hankija esitatud nõuetest ja riigihangete seadusest ning
teistest Eesti Vabariigis kehtivatest õigusaktidest.
4.3. Pakkujal ei ole lubatud kaasata üle 10% hankelepingu maksumusest hankelepingu täitmisele
alltöövõtjaid, tarnijaid ega tugineda kvalifitseerimistingimuste täitmisel selliste ettevõtjate
näitajatele, kes on:
4.3.1. Vene Föderatsiooni kodanik, resident või Vene Föderatsioonis asutatud ettevõtja, sh
füüsilisest isikust ettevõtja, juriidiline isik, asutus või muu üksus;
2
4.3.2. rohkem kui 50% ulatuses otseselt või kaudselt punktis 4.3.1. nimetatud isiku, asutuse või
muu üksuse omandis;
4.3.3. punktis 4.3.1 või 4.3.2 nimetatud isiku, asutuse või muu üksuse esindaja või tegutseb
sellise isiku juhiste alusel.
Hankijal on õigus nõuda andmeid alltöövõtjate ja tarnijate ning tuginetavate isikute, nende
esindajate või muu juhtimis-, haldus- või järelevalveorgani liikmete, otseste ja kaudsete
omanike ja tegelike kasusaajate kohta, sh füüsiliste isikute isikut tõendavate dokumentide
koopiaid, millelt nähtub isiku kodakondsus ja juriidiliste isikute kohta isiku asukohamaa
äriregistri või muu pädeva asutuse tõendit või väljavõtet. Hankijal on õigus nõuda andmeid
alltöövõtja ja tarnija poolt täidetava hankelepingu osa suuruse kohta. Hankija lükkab
tagasi pakkumuse, mille alusel sõlmitav hankeleping oleks RSanS § 7 lg 1 alusel tühine.
4.4. Pakkumuse esitamisega kinnitab pakkuja täielikku nõustumist kõigi riigihanke tingimustega,
sealhulgas lepingute tingimustega, ning pakkuja ei saa lisada pakkumusele omapoolseid
tingimusi.
4.5. Pakkumuse võib esitada vaid nende asjaolude kohta, mille kohta hankija on võistlevaid
pakkumusi soovinud.
4.6. Pakkuja kannab kõik pakkumuse ettevalmistamise ning esitamisega seotud kulud.
4.7. Pakkumus tuleb esitada arvestusega, et pakutavad objektid peavad vastama täies ulatuses
hanke alusdokumentides ja Eesti Vabariigi õigusaktides kehtestatud nõuetele.
4.8. Pakkumuse esitamist e-RHRis tuleb alustada piisava ajavaruga (soovitavalt mitte hiljem kui 2
tundi enne pakkumuste esitamise tähtpäeva) ning probleemide tekkimise korral pöörduda
riigihangete registri kasutajatoe poole. Kui süsteemis tehnilisi tõrkeid ei ole tuvastatud, üritab
kasutajatugi pakkujat e-RHRi kasutamisel abistada.
4.9. Pakkumus tuleb esitada elektrooniliselt e-RHRi kaudu aadressil https://riigihanked.riik.ee.
Pakkumuse allkirjastamine ei ole nõutav.
4.10. Hankija aktsepteerib esitatavate pakkumuse dokumentide osas kõiki üldlevinud dokumendi
formaate (näiteks .pdf Portable Document Format; .txt Text; .rtf RichTextFormat; .odt Open
Office; MS Office formaate).
4.11. Pakkumuse dokumentide mahupiirangud e-RHR-is on soovitavalt 20MB ühe dokumendi
kohta ja 100MB pakkumuse kogumahu kohta.
4.12. Pakkuja ei krüpteeri pakkumuse dokumente, kuna e-RHR-is on tagatud pakkumuste
konfidentsiaalsus ning see, et pakkumused saab avada ning tutvuda nende sisuga alles pärast
pakkumuste esitamise tähtpäeva möödumist.
4.13. Hankija ei vastuta võimalike viivituste, tõrgete või katkestuste eest, mida põhjustavad e-
RHR-is hankija kontrolli alt väljas olevad asjaolud nagu force majeure, elektrikatkestused,
häired pakkuja või hankija telefoni- või internetiühenduses või muude elektrooniliste seadmete
ja vahendite, sealhulgas tarkvara tööd. Hankija ei vastuta e-RHR-i kasutamisest või
mittekasutamisest tekkinud kahjude või saamata jäänud tulu eest.
4.14. Kui hankija esitatud nõuded või tähtajad on hanketeates ja hanke alusdokumentides
erinevad, tuleb lähtuda hanketeatest.
4.15. Pakkumuse esitamise tähtpäev
4.15.1. Pakkumused esitada hanketeates toodud pakkumuse esitamise tähtpäevaks. Peale
vastava tähtpäeva saabumist ei võimalda e-RHR-i süsteem pakkumust esitada.
4.15.2. Hankija kasutab käeolevas hankemenetluses RHS § 93 lg 2 p 2 sätestatud pakkumuste
esitamise tähtaja lühendamist, kuna hankemenetluse läbiviimine on muutunud kiireloomuliseks.
Varasemalt läbi viidud hankemenetluse ebaõnnestumise tõttu ei ole hankijal võimalik rakendada
30-päevast pakkumuste esitamise tähtaega, kuna pikem tähtaeg ei võimalda seadmetega
seonduvad olulisemaid paigaldustöid piisavas mahus teostada 2023.a suveperioodil, mil koolis ei
toimu aktiivset õppetööd.
4.15.3. Pakkuja võtab enda kanda pakkumuse e-RHR-i sisestamise kogu riski, kaasa arvatud
vääramatu jõu toime võimaluse.
4.16. Pakkumuse vormistamine
4.16.1. Pakkumus peab vastama hanke alusdokumentides esitatud tingimustele ning
riigihangete seadusele.
4.16.2. Hinnapakkumus tuleb esitada vastavalt Hankija poolt e-RHR-s koostatud vormil. Kui
hankija on ette näinud e-RHR maksumuse vormile täiendava maksumuse vormi, siis tuleb
pakkujal esitada ka täiendav maksumuse vorm. Kui pakkumuse maksumused erinevad e-RHR-s
koostatud vormil ja hankija täiendaval vormil, siis lähtutakse hankija antud täiendavast
3
maksumuse vormist ning see on aluseks ka tööde akteerimisel ja võimalike muudatustööde
arvestamisel.
4.16.3. Hinnapakkumuse täitmisel peab pakkuja arvestama, et esitatud hindadega oleks
võimalik täita sõlmitavaid lepinguid nõuetekohaselt ja pakutavad hinnad sisaldaksid kõiki
tulemuse saavutamiseks vajalikke lisateenuseid.
4.16.4. Pakkuja peab pakkumuse koosseisus esitama kõik e-RHR-i keskkonnas nimetatud
informatsiooni ja dokumendid.
4.17. Ühispakkumuse esitamine
4.17.1. Ühispakkujad võivad oma majandusliku ja finantsseisundi ning tehnilise ja kutsealase
pädevuse tõendamiseks tugineda teiste ühispakkujate vahenditele vastavalt RHS paragrahvi
103 lõigetes 1–3 ja 7 sätestatud tingimustele.
4.17.2. Kõrvaldamise aluseid ei tohi esineda ühelgi ühispakkujal.
4.17.3. Kõikide ühispakkujate kohta eraldi tuleb esitada hankepass koos kõrvaldamise aluste
puudumise kinnitustega ning vastavatele kvalifitseerimistingimustele vastamise kinnituste ja
andmetega.
4.17.4. Kui pakkumuse esitavad mitu pakkujat ühiselt, peavad nad hankemenetluse ning
hankelepingu sõlmimise ja täitmisega seotud toimingute tegemiseks volitama enda hulgast
esindaja.
4.18. Rahaühik
Pakkumuse hinnad esitada eurodes ilma käibemaksuta.
4.19. Keel
Pakkumus ja pakkumusele lisatavad dokumendid tuleb esitada eesti keeles kui hanke
alusdokumendid ei sätesta vastavas osas teisiti. Välisriigi ametiasutuse poolt väljastatud mitte
eesti keelse dokumendiga koos tuleb esitada tõlge eesti keelde. Eesti keeles esitatakse ka
selgitustaotlused ja selgitused.
4.20. Pakkumuste jõusoleku aeg
Pakkumused peavad olema jõus 4 kuud pakkumuse esitamise päevast arvates.
4.21. Alternatiivsete lahenduste esitamine
Alternatiivsete lahenduste esitamine ei ole lubatud.
4.22. Lepingu täitmise kohaga tutvumine
4.22.1. Enne pakkumuse esitamist ei ole vajalik lepingu täitmise asukohaga tutvuda.
5. Vastavustingimused
5.1. Kui esitatakse ühispakkumus, siis esitada kirjalik volikiri ühele pakkujale teis(t)e pakkuja(te)
esindamise kohta;
5.2. Esitada kinnitus, kas pakkumus sisaldab või ei sisalda ärisaladust ja vastavalt
hankedokumendi punktile 7 pakkumuses ärisaladuse määratlemisel lisada põhjendus, et miks
on vastava informatsiooni puhul tegemist ärisaladusega;
5.3. Esitada kinnitus, et pakutav kaup ei ole rahvusvahelise sanktsiooni objektiks ega pärit
sanktsiooni all olevatest piirkondadest rahvusvahelise sanktsiooni seaduse (RSanS) § 7 lg 1
mõttes;
5.4. Esitada kinnitus, et pakkuja pakub hankeobjekti vastavuses hankija poolt esitatud nõuetega;
5.5. Esitada pakutavate ruumiandurite ja kliimaandurite tehniline spetsifikatsioon;
5.6. Esitada pakutava süsteemi ja selle funktsionaalsuse kirjeldus;
5.7. Esitada kinnitus, et pakkuja suudab hankija tingimustele vastava süsteemi üle anda hiljemalt
20. detsember 2023.a;
5.8. Esitada kinnitus, et pakkuja suudab hankija nõudmisel pakkumuse vastavuse kontrolli etapis
tõendada pakutava tarkvara vastavust hankija tingimustele reaalse töötava antud hankes
pakutava tarkvara peal;
5.9. Esitada pakkumuse maksumuse lahtikirjutus vähemalt lisa 4 detailsuses;
5.10. Esitada kinnitus, et pakkuja vastab hankedokumendi punktis 4.3 kehtestatud tingimusele.
6. Pakkumuse tagatis
6.1. Pakkumuse tagatist ei rakendata.
4
7. Pakkumuses sisalduv ärisaladus
7.1. Pakkuja kohustub pakkumuses arusaadavalt märgistama, milline tema poolt esitatud teave on
pakkuja ärisaladus.
7.2. Kui pakkuja on pakkumuses ärisaladuse vastavalt märgistanud, peab pakkuja põhjendama,
miks on vastava teabe puhul tegemist ärisaladusega.
7.3. Teabe ärisaladuseks määramisel lähtub pakkuja ebaausa konkurentsi takistamise ja
ärisaladuse kaitse seaduse § 5 lõikes 2 sätestatust.
7.4. Pakkujal ei ole õigust ärisaladusena märgistada RHS 46¹ lg 1 nimetatud teavet.
7.5. Pakkuja peab arvestama, et pakkumus on konfidentsiaalne kuni RHS § 117 lõikes 1 nimetatud
pakkumuse edukaks tunnistamise otsuse tegemiseni ja peale nimetatud otsuse tegemist on
hankija kohustatud vastava taotluse saamisel pakkumuse avalikustama ulatuses, mis pole
märgistatud ärisaladusena.
8. Pakkujate hankemenetlusest kõrvaldamine ja kvalifitseerimine
8.1. Hankijal on õigus teostada kõrvaldamise aluste kontrolli ja kvalifitseerimist RHS § 52 lg 3 ja §
104 sätestatud korras, mis tähendab, et kõrvaldamise aluste kontroll ja kvalifitseerimise
tingimustele vastavuse kontroll viiakse sellisel juhul läbi peale eduka pakkuja välja valimist.
8.2. Hankija kontrollib riigihangete seaduses ja riigihanke alusdokumentides kehtestatud
kõrvaldamise alustest ja kvalifitseerimise tingimustest lähtuvalt, et edukal pakkujal (sh
ühispakkujal ja isikul kellele pakkuja on tuginenud) ei esineks riigihankest kõrvaldamise aluseid
ning et pakkuja vastaks kvalifitseerimiseks esitatud nõuetele.
8.3. Hankija kõrvaldab hankemenetlusest pakkuja (sh ühispakkuja ja isiku, kellele pakkuja on
tuginenud) kellel esineb riigihangete seaduse § 95 lg 1 nimetatud kõrvaldamise alus. Hankijal
on õigus kõrvaldada menetlusest pakkuja, kellel esineb § 95 lg 4 nimetatud kõrvaldamise alus.
8.4. Hankija rakendab käesolevas hankemenetluses RHS § 97 sätesatud heastamise võimalust.
9. Pakkumuste vastavaks tunnistamine ja pakkumuste tagasilükkamine
9.1. Hankija kontrollib vastavalt riigihangete seadusele pakkumuste vastavust riigihanke
alusdokumentides sätestatud tingimustele.
9.2. Hankija lükkab pakkumuse tagasi, kui see ei vasta riigihanke alusdokumentides esitatud
tingimustele, kui pakkuja ei esita tähtajaks hankija nõutud selgitusi või pakkuja selgituste põhjal
ei ole võimalik üheselt hinnata pakkumuse vastavust riigihanke alusdokumentides esitatud
tingimustele.
9.3. Hankija lükkab pakkumuse tagasi, kui hankelepingu sõlmimine selle pakkumuse alusel rikuks
rahvusvahelist või Vabariigi Valitsuse sanktsiooni rahvusvahelise sanktsiooni seaduse
tähenduses.
9.4. Hankijal on õigus tunnistada pakkumus mittevastavaks kui hinnapakkumus või maksumuse
lahtikirjutus ei ole esitatud hankija poolt nõutud vormi ja struktuuri kohaselt või on esitamata
muud hindamise aluseks olevad andmed või dokumendid.
9.5. Hankija võib tunnistada pakkumuse vastavaks, kui selles ei esine sisulisi kõrvalekaldeid
riigihanke alusdokumentides nimetatud tingimustest.
9.6. Hankijal on õigus tagasi lükata kõik pakkumused kui:
9.6.1.pakkumuste hinnad ületavad lepingu eeldatavaid maksumusi;
9.6.2.tekib vajadus riigihanke objekti olulisel määral muuta;
9.6.3.hankijal kaob vajadus hankeobjekti järele.
10. Pakkumuste võrdlemine ja hindamine
10.1. Hankija hindab vastavaks tunnistatud pakkumusi vastavalt riigihanke alusdokumentides
nimetatud pakkumuste hindamise kriteeriumitele. Hankija tunnistab põhjendatud kirjaliku
otsusega edukaks pakkumuste hindamise kriteeriumide kohaselt majanduslikult soodsaima
pakkumuse.
10.2. Hankija arvestab majanduslikult soodsaima pakkumuse väljaselgitamisel kogumaksumust
ilma käibemaksuta. Madalaima maksumusega pakkumus saab 100 punkti ja teised
pakkumused saavad proportsionaalselt vähem punkte. Edukaks tunnistatakse pakkumus, mis
saavutas suurima punktisumma. Hindamistäpsus on kaks kohta peale koma. Võrdsete
tulemuste korral, toimub liisu heitmine.
10.3. Liisu heitmisele võimaldatakse kõikide pakkujate volitatud esindajate juurdepääs. Liisu
heitmiseks valmistatakse ette nii mitu sedelit, kui on võrdseid pakkumusi. Ühele sedelile
märgitakse peale „edukas pakkumus“, ülejäänud jäetakse tühjaks. Sedelid suletakse
5
läbipaistmatusse konteinerisse. Loosikastist konteineri võtmine toimub pakkumuste esitamise
ajalisest järjekorrast lähtuvalt (esimesena pakkumuse esitanu valib esimesena). Pakkuja
esindaja, kes saab loosikastist sedeli, millele on peale märgitud „edukas pakkumus“,
tunnistatakse käesolevas riigihankes edukaks. Liisuheitmise koht ja ajakava teatatakse
eelnevalt pakkujatele.
11. Lepingu sõlmimise tingimused
11.1. Eduka pakkujaga sõlmitakse pärast pakkumuse edukaks tunnistamist leping lisa nr 2 alusel.
11.2. Pakkuja peab allkirjastama ja tagastama talle allkirjastamiseks edastatud lepingu hiljemalt 3
tööpäeva jooksul alates hankija poolsest lepingu edastamisest. Antud tähtaja jooksul lepingu mitte
allkirjastamisel ja mitte tagastamisel on hankijal õigus rakendada RHS § 119 lg.
6
Lisa 1 – tehniline kirjeldus
Hankija: Eesti Kunstiakadeemia
Riigihanke nimetus: Ruumikasutuse ja sisekliima monitooringu süsteem energiatarbimise
optimeerimiseks
Riigihanke viitenumber: 266125
1. Riigihanke eesmärk ja üldine info
1.1. Hankija soovib monitoorida oma õpperuumide kasutamist ja täituvust eesmärgiga
saavutada märgatav energiasääst ja sisekliima paranemine. Selleks hangitakse “võtmed
kätte lahendusena” ruumikasutuse monitoorimise IT süsteem, mis kasutab ruumiandureid,
lidartehnoloogiat ning tehisintellekti.
1.2. Riigihanke tulemusena sõlmitakse pakkujaga hankeleping andurite paigalduseks, IT
süsteemi juurutamiseks, garantii ning hooldustöödeks ning IT süsteemi kasutusõiguse
ostuks.
1.3. Eesti Kunstiakadeemia (EKA) soovib monitoorida oma:
1.3.1. õpperuumide kasutamist ja täituvust eesmärgiga saavutada olemasolevate ruumide
tõhusam kasutamine ning
1.3.2. ruumide sisekliimat reaalajas eesmärgiga selle kvaliteeti parandada ja stabiliseerida.
Mõlema tegevuse tulemusena soovitakse saada märgatav energiasääst, mis on projekti
lõppeesmärk. Selleks plaanitakse hankida ruumikasutuse monitoorimise IT süsteem, mis
koosneb tarkvarast ja riistvarast. Süsteem kasutab lidartehnoloogial ruumiandureid ning
tehisintellekti.
1.4. Õpperuumide kasutuse monitoorimise lahendus digitaliseerib andmekogumise protsessi,
millega saadakse infot ruumi kasutavate inimeste arvust ja ruumide kasutamise aegadest
reaalajas ning ruumide siseõhu näitajatest. Kogutud andmete põhjal saab teha täpset
analüütikat, mille baasilt langetada edasisi otsuseid.
Andmed kogutakse internetti ühendatud (IoT) andurite poolt reaalajas ning saadava
informatsiooni alusel on võimalik saavutada oluline energiakokkuhoid juhtides nutikalt ja
vajaduspõhiselt ruumidega seotud ventilatsiooni, kütte ja valgustuse vajadust. Kogutud
andmete baasil saadakse vajalik komplekt graafiliselt kuvatud aruandeid, mille alusel saab
hankija teha kvalifitseeritud otsuseid.
1.5. Lisaks eelpool toodud energiasäästu ning pinnakasutuse suurendamisele, kaasuvad
projektiga veel järgmised oodatavad tulemused:
1.5.1. Kasutajate teadlikkuse tõstmine oma rollist energiakokkuhoiu saavutamiseks;
1.5.2. Hoone ja ruumide kasutajate harjumuste kujundamine jätkusuutlikkuse
põhimõtteid järgides;
1.5.3. Jätkusuutlikkuse põhimõtete kasutamine tudengite õppeprotsessis, uurides
kogutud analüütikat;
1.5.4. Andmete kasutamine ja uute sisendite kogumine järgnevateks teadus-
arendusprojektideks, innovaatiliste tudengitööde tutvustamine laiemalt;
1.5.5. EKA unikaalse Targa Maja lahenduste tutvustamine teistele sidusrühmadele nii
Eestis kui välismaal;
1.5.6. EKA maine tõus innovatiivse organisatsioonina, mille kogukond kaasatakse
unikaalsetesse teadus-arendusprojektidesse.
2. Nõuded ruumianduritele, monitoorimise süsteemile ning paigaldusele
2.1. Ruumiandurid ja monitoorimise süsteem peavad vastama vähemalt alljärgnevatele
nõuetele:
2.1.1. Pakutav süsteem peab olema terviklik süsteem, mis täidab punktis 1 kirjeldatud
hankija eesmärgid ja koosneb sobivast tarkvarast ning sellega integreeritud
reaalajas toimivatest anduritest.
2.1.2. Igas 83 ruumis (lisa 3) tuleb monitoorida reaalajas inimeste arvu, kasutades
lidaripõhist tehnoloogiat. Tulemused tuleb kuvada graafiliselt hoone plaanidele
vastavalt ruumidele. Lisaks tuleb igas ruumis mõõta temperatuuri, CO2 ja niiskuse
taset ning need tulemused tuleb samuti graafiliselt kuvada.
2.1.3. Süsteem peab kasutama tehisintellekti, rakendades süvaõppe (deep learning) ja
objektijälgimise algoritme.
2.2. Nõuded ruumikasutusanduritele:
2.1.1. Andurid peavad pakkuma reaalajas andmeid ja ülevaadet hoone ruumikasutuse,
hõivatuse taseme kohta.
2.1.2. Andurid peavad olema ühendatud võrku ja edastama turvaliselt mittejälgitavaid
metaandmeid ja analüütikat pakutavale pilvepõhisele haldus- ja
analüüsiplatvormile.
2.1.3. Andurid peavad töötama lidartehnoloogial ega ei tohi koguda ning salvestada
isikustatud teavet ega väljastada pilte.
2.1.4. Andurid peavad töötama täiesti anonümiseeritult, tajudes vaid inimese
individuaalset liikumist. Andurid ei tuvasta ega jälgi isiklikke seadmeid, nagu
näiteks mobiiltelefone.
2.1.5. Andurid peavad töötama vähemalt LAN või WIFI võrgus.
2.1.6. Seadmed peavad kasutama PoE toidet. Töötab vahelduvvoolul (DC) või PoE (RJ-
45 (Cat 5e kaabel või parem).
2.1.7. Andurid peavad võimaldama paigaldust kõrguse vahemikus vähemalt 2,5m-4,6m
põrandapinnast.
2.1.8. Anduritel peavad olema sertifikaadid – FCC, CE. Andurite turvalisus peab vastama
EN 60950-1, ekvivalentne UL_IEC/UL 60950 Infotehnoloogia seadmed –
turvalisus - Osa 1 (või samaväärne).
2.3. Nõuded õhukvaliteedi anduritele:
2.2.1 Peab olema mõeldud siseruumides kasutamiseks.
2.2.2 Peab töötama PoE või patareitoitel. Patareitoite puhul peavad seadmed jälgima
patareide tööiga, patarei oodatav tööiga vähemalt 8 aastat.
2.2.3 Nõuded temperatuuri mõõtmisel: Resolutsioon vähemalt 0.1°C, täpsus vähemalt
+/-0.2°C.
2.2.4 Nõuded niiskuse mõõtmisel: Resolutsioon vähemalt 0.1 % RH, täpsus 25°C juures
vähemalt +/-2% RH.
2.2.5 Nõuded CO2 mõõtmisel: Ulatus vähemalt 0-10000 ppm, täpsus vähemalt +/-50
ppm/+ /-3% loetust.’
2.2.6 Andurite paigalduse kõrgus peab olema vähemalt vahemikus 2,5m-4,6m
põrandapinnast.
2.2.7 Vähemalt NFC (Near Field Communication) konfigureerimise võimalus.
2.2.8 Andurite paigalduskõrgus peab võimaldama mõõta andmeid ruumi kasutaja
mugavustsoonis.
2.4. Tööd hõlmavad endas vähemalt alljärgnevaid tegevusi:
2.4.1. Hankija annab ruumide nimekirja (lisa 3) ja ruutmeetrid, mille alusel pakkuja peab
andurite hulga ruumi kohta hindama ise vastavalt oma tehnoloogiale.
2.4.2. Pakkuja peab arvestama, et ruumid on erineva kõrgusega. Lisaks lisab hankija
hankesse kaasa ruumi lõiked, plaanid ja virtuaalse 3D tuuri ning muud vajalikud
tehnilised projektid.
2.4.3. Tellija poolsed LAN võrgu ühenduspunktid on toodud ruumide nimekirjas (2.3.1.)
Ülejäänud võrgulahendused (nt switchid jms) peab pakkuma pakkuja ise.
2.4.4. Pakkuja korraldab kõik projekteerimistööd ,ehitustööd ja hangib vajalikud
kooskõlastused, load ja muu süsteemi kasutusele võtuks vajaliku
dokumentatsiooni jms.
2.4.5. Põhja puiestee 7 hoone projektdokumentatsioon on kättesaadav
https://drive.google.com/drive/u/0/folders/13p_fco1MkzKS9RVPgdNWXiJIdIqyW-
jJ
2.4.6. Pakkujal on kohustus kontrollida esitatud tööde mahtusid/andmeid ning pakkumise
maksumuses arvestada hanke eesmärgi saavutamiseks vajalike tööde ja
töömahtudega. Hilisemaid pretensioone mahtude erinemisest tingitult ei rahuldata.
2.4.7. Objektidega on võimalik enne pakkumuse esitamist tutvuda (soovijatel
registreeruda
[email protected]). Tutvumise aeg hankest huvitatud
isikutele on 20.06.2023 kell 12:00. Hankijal on õigus määrata ka täiendav
tutvumise aeg, teatades sellest Riigihangete registri vahendusel riigihankest
huvitatud isikutele.
2.4.8. Kõigis osades täpsete juhiste puudumisel peavad tööd sisaldama kõiki kirjeldatud
eesmärgi saavutamiseks tavapäraselt vajalikke tegevusi.
2.4.9. Mitmeti tõlgendatavad lahendused/formuleeringud/tööd kui nende kohta ei ole
esitatud hanke ajal täpsustatavaid küsimusi, loetakse prioriteetseks hankijale
soodsam tõlgendus.
2.4.10. Seadmete paigaldus ja vahetus kooskõlastatakse operatiivselt hankijaga ,et
minimeerida häireid majade töös (tööd peab korraldama selliselt, et õppetegevust
häirida võivad olulised seadmete paigaldusega seonduvad tööd tuleb teostada
suveperioodil kuni 20. august 2023). Muul ajal paigaldustööde teostamisel tuleb
arvestada tunniplaaniga ja paigalduse aeg tuleb kooskõlastada hankijaga.
2.4.11. Tellija eelistab peidetud kaabeldust. Ruumides kus pole seda võimalik mõistlikult
saavutada on lubatud kasutada pinnapealset kaabeldust mis on peidetud
interjööriga sobivasse karbikusse ja kooskõlastatakse eelnevalt tellijaga. Üldjuhul
on võimalik enamus kohtades liikuda lamelllagede pealt või mööda erinevaid
kaabliredeleid. Nähtavad nõrkvoolu projektis.
2.4.12. Pakkumise mahtu kuuluvad ka kõik need tegevused, mis ei ole tehnilises
kirjelduses otseselt kirjeldatud, kuid mille tegemine on tavapäraselt vajalik
kirjeldatud eesmärgi saavutamiseks, samuti need tegevused, mis tulenevad
seadustest ja headest tavadest.
2.4.13. Teha süsteemi toimivuse kontroll pärast paigaldust (tulemused peavad vastama
hankija seatud nõuetele). Tulemused esitada digitaalselt ühes eksemplaris.
2.4.14. Pakkuja ei tohi tekitada kahju hankija varale ning nende tekkimisel kannab kulud
tekkinud kahjude osas.
2.4.15. Tööde käigus tekkinud jäätmed utiliseerida ja töömaa puhastada ning koristada
tekkinud prahist ning võimalikust mustusest.
2.4.16. Pakkumine peab sisaldama kõiki kulusid (transpordi, mahalaadimise, kauba
pakendamise, töö teostamiseks vajalike lisavahendite ja -materjalide hinda,
makse, tasusid jms) välja arvatud käibemaks ning olema hankija jaoks lõplik.
2.4.17. Pakkuja peab tegema töö vastavalt oma erialastele teadmistele, oskustele ja
võimetele, kasutades lepingus sätestatud töö tegemisel tööjõudu, kelle koolitus,
oskused ja kogemused vastavad töö ulatusele, iseloomule ja keerukusele.
2.4.18. Pakkuja annab tema poolt ja korraldusel tehtud töödele vähemalt 2 aastase
garantii.
3. Nõuded kasutajaliidesele ja aruandlusele
3.1. Pakutav tarkvara- ja riistvarakomponentidest koosnev süsteem peab andma
organisatsiooniülese paindliku, hästi süstematiseeritud ja kasutajasõbraliku tööriista
ruumikasutuse ja sisekliima kvaliteedi andmete kogumiseks, monitoorimiseks ja
analüüsimiseks. Töökeskkonna juhtimiseks ning parimate otsuste tegemiseks saavad seda
kasutada erinevate vastutusvaldkondade töötajad – näiteks haldusjuht, finantsjuht,
analüütik, kellele saab kuvada rollipõhised vaated.
3.2. Anduritelt kogutavat infot kuvatakse töölaudadele reaalajas, graafiliselt hästiarusaadavate
aruannetena, millel peab olema lai ja paindlik filtreerimise ja üldiselt detaili liikumise loogika,
need annavad kõikidest andmetest dünaamilise ülevaate.
3.3. Sensorandmed peavad olema anonümiseeritud ja need kuvatakse reaalajas 3D või 2D
korruseplaanidele, mistõttu on hoone kasutamise andmed alati terve päeva lõikes näha -
millised hoone osad on alakasutatud ja kuidas nende kasutamise tõhusust andmeanalüüsi
alusel parandada. Millistest ruumides on millisel ajal missugused siseõhu parameetrid ja
kuidas neid peaks vastavalt kasutusele muutma.
3.4. Süsteem peab kogutud andmeid analüüsima pinnakasutuse aspektist, välja peavad
joonistuma kindlad korduvad mustrid, mis võimaldavad edaspidi juba planeerida kütte-,
valgustuse-, ja ventilatsiooni vajadust ning saavutada olulist energia kokkuhoidu ja
vähendada CO2 emissiooni. Lisaks energiaäästule on loodav aruandlus ka sisendiks
efektiivsemale ruumi kasutuse plaanile.
3.5. Peab kuvama reaalajas andmed (vähemalt inimeste arv, ruumide temperatuurid, co2,
niiskus) hoone plaanidele vastava ruumi kontuuri sees.
3.6. Süsteem peab võimaldama reaalajas graafiliselt esitatud ülevaadet ruumide kasutamisest
dünaamilisel töölaual (sh filtrivalikud – kuupäev, piirkond, kategooria), sh:
3.6.1. Korruseplaanil peavad olema näha ruumid koos kasutusmääradega (isikustamata
inimeste arv, kes ruumis viibivad).
3.6.2. Hoonete erinevate tellija poolt määratud piirkondade (nt korpused, korrused jms)
kasutusmäärade võrdlemine.
3.6.3. Ruumide täituvuse diagramm nädalapäevade kaupa – ruumide kasutus tundide
lõikes igal päeval ja nädalal. Näiteks: kõige aktiivsemalt kasutuses olnud
piirkonnad hoones päevade ja tundide kaupa.
3.6.4. Ülevaate saamine ruumivajaduse kokkuhoiuvõimalustest ja kulude kokkuhoidu
muudetavate parameetrite põhjal, näiteks ruutmeetri hind või tööruumi keskmise
ruutmeetri võrdlusalus, mis mõjutab kulusid ja ruumi kokkuhoidu.
3.6.5. Inimeste arvu suhe ruumi tegelikku mahutavusse (%), eeldusel, et vastava
ruumiinfo on süsteemi sisestatud.
3.7. Süsteem peab võimaldama analüütikat ja aruandlust, mille alusel saab teha vähemalt
alljärgnevaid otsuseid:
3.7.1. Ruumi tagasikorraldus - milliseid loenguid/praktikume saab ruumidesse planeerida
nende tegeliku kasutuse alusel.
3.7.2. milliseid ruume on võimalik vähese kasutamise tõttu sulgeda/kasutusotstarvet
muuta.
3.7.3. vajaminevate ruumide arv ja nende mahutavus.
3.7.4. millised päevad ja kellaajad on konkreetsete ruumide puhul kõige enam nõutud.
3.7.5. kas ja kuidas on võimalik optimeerida ruumide paigutus, näiteks kas on vaja
rohkem väiksemaid või rohkem suuremaid ruume.
3.7.6. Boxplot (või samaväärne) analüüs, mis näitab ülevaatlikult võimalike
kõrvalekalletega andmepunktide jaotust.
3.8. Süsteem peab võimaldama energia kokkuhoiu analüütikat, mille alusel saab teha vähemalt
alljärgnevaid otsuseid:
3.8.1. Millistes ruumides vähendada kütet, valgustust ja ventilatsiooni jooksvalt vastavalt
tegelikult täituvusele.
3.8.2. Kuidas planeerida ruumide kütte-, valgustuse-, ja ventilatsioonivajadust
ettevaatavalt toetudes andmeanalüüsile.
3.9. Süsteem peab võimaldama korruste ja ruumide kaupa sisekliima kvaliteedi andmeid ja
analüütikat, mille alusel saab sealhulgas teha vähemalt alljärgnevaid otsuseid:
3.9.1. Õhukvaliteediandurite kogutud info peab olema visualiseeritud ruumitäpsusega
hoone korruseplaanidel ühtses vaates.
3.9.2. süsteem peab olema võimeline kuvama temperatuuriandmete visuaalset esitlust
soojuskaardi (heat map) kujul.
3.9.3. Süsteem peab kuvama, millised on sisekliima näitajad reaalajas – CO2, niiskus,
temperatuur.
3.9.4. Süsteem peab näitama, et kuidas saavutada optimaalsed sisekliima näitajad ning
kuidas selleks hooneautomaatikat juhtida.
3.10. Klikkides ruumile peab saama välja võtta logid mõõtmise intervalliga minimaalselt 5
kuni 1 kord tunnis vastavalt filtrile iga ruumi kohta.
3.11. Kasutajaliidesest peab olema võimalik välja importida andmeid vähemalt PDF
formaadis ja Excel tarkvaras loetavas formaadis olenevalt filtrist ühe ruumi, ühe korruse,
ühe korpuse ja kogu hoone kohta.
3.12. Pakkuja peab suutma hankija nõudmisel pakkumuse vastavuse kontrolli etapis
tõendada pakutava tarkvara vastavust hankija tingimustele reaalse töötava antud hankes
pakutava tarkvara peal.
4. Nõuded andmete väljunditele järgmiste süsteemide tarbeks:
4.1. Täiendava võimalusena saab loodava lahenduse poolt edastav reaalajas info olla ka
sisendiks Fusebox.energy poolt pakutava paindliku energiatarbimise süsteemiga (virtual
power plant) integreerumiseks, mis annab täiendava võimaluse vähendada energiaga
seotud kulutusi.
4.2. REST API teenuse kaudu tuleb tagada teistele süsteemidele ligipääs tarkavasse loetud
andmetele. See loob eelduse hoone automaatikasüsteemi liidestamiseks ning võimaldab
anda REST API liidese teel infot hooneautomaatika süsteemi jälgimiseks ja juhtimiseks.
4.3. Hankija edaspidine vajadus on liidestus tunniplaanisüsteemiga „Tahvel“
(https://tahvel.edu.ee/) ja hoone automaatikaga.
5. Tööde teostamise tähtajad ja etapid
5.1. Seadmete paigaldustööd ning hankija nõutud tingimustel süsteemi töö tuleb tagada
hiljemalt 20. detsember 2023.a.
5.2. Süsteemi kasutusõigus ostetakse kuni tähtajaga 30.06.2026.a.
6. Maksumus
6.1. Pakkumuse maksumus peab sisaldama kõiki vajalike seadmeid, nende paigaldust ja
tarkvara kasutustasu kuni tähtajani 30.06.2026.a. Sealhulgas hõlmab maksumus:
6.1.1. korruseplaanide sisestamist tarkvarasse
6.1.2. tarkvara kasutustasu kuni 30.06.2026.a
6.1.3. kasutajate lisamist ja nende litsentse (2 samaaegset administraatori õigustega
peakasutajat ja 5 tavakasutajat, kes tarbivad aruandlust)
6.1.4. tarkvara juurutamist
6.1.5. andureid ja nende paigaldust vastavalt plaanidele
6.1.6. aruannete seadistamist
6.1.7. eelduste loomist andmevahetuseks hooneautomaatikasüsteemiga REST API
teenuse kaudu
6.1.8. süsteemi testimist
6.1.9. kasutajakoolitusi
6.1.10. tehnilist tuge tarkvara kasutusperioodil ja tarkvarauuendusi
6.2. Pakkumuse maksumuse lahtikirjutus esitada vähemalt hankedokumendi lisa 4 detailsuses.
6.3. Makseetappidena aktsepteerib hankija ühte vahemakset, mis saab toimuda kas punktis
6.1.1-6.1.3 või 6.1.1.-6.1.4. tegevuste teostamise järgselt. Vahemakse suurus saab olla
kuni 20% kogu tööde kogu maksumusest. Ülejäänud osa tasust makstakse välja süsteemi
üleandmise-vastuvõtmise akti allkirjastamise järgselt 14 päeva jooksul alates arve
esitamisest.
6.4. Peale lepingu lõppemist peab olema võimalik sõlmida uus leping jätkates teenuse
kasutamist iga-aastase teenustasu alusel.
7. Garantii, hooldus ja remont
7.1. Pakkuja tagab süsteemile ja paigaldatud anduritele vähemalt 24 kuulise garantii alates
süsteemi üleandmise akti allkirjastamisest.
7.2. Nõuded tehnilisele toele:
7.2.1. Pakkuja kohustuseks on lepingu kehtivuse ajal pakkuda tehnilise toe teenust (sh
telefoni ja e-posti teel) tööpäevadel vahemikus kell 9-17;
7.2.2. Reageerimisaega arvestatakse hetkest, mil kasutaja on edastanud teate
intsidendist teenusepakkujale;
7.2.3. Tehnilise toe puhul tuleb tagada juhtumite lahendamine vähemalt järgmise
operatiivsusega:
Prioriteetsus Juhtumi ulatus ja mõju Reageerimisaeg Lahendamise
aeg
Kiireloomuline - Tarkvara pole täielikult kättesaadav 4 tundi 8 tundi
- Peamine funktsioon pole saadaval, mis mõjutab
kasutaja tegevust kriitiliselt
- Kriitiline jõudluse halvenemine kõikidele
kasutajatele
Kõrge - Tarkvara olulised osad pole kättesaadavad 8 tundi 16 tundi
- Mõned funktsioonid pole saadaval, mis mõjutavad
kasutaja tegevust oluliselt
- Märkimisväärne jõudluse halvenemine kõikidele
kasutajatele
Keskmine - Tarkvara mittekriitilised osad pole kättesaadavad 2 tööpäeva 5 tööpäeva
- Mõned funktsioonid pole saadaval, mis mõjutavad
kasutaja tegevust mitteoluliselt
- Mittekriitiline jõudluse halvenemine kõikidele
kasutajatele
Madal Ebaolulised puudused tarkvara töös 5 tööpäeva 15 tööpäeva
Uus sõnum riigihankes 266125
Riigihanke 266125 "Ruumikasutuse ja sisekliima monitooringu süsteem energiatarbimise
optimeerimiseks" raames on saadetud teade: Tere, Teatame Teile, et hankementluses
„Ruumikasutuse ja sisekliima monitooringu süsteem energiatarbimise optimeerimiseks“
viitenumbriga 266125 tehti Eesti Kunstiakadeemia poolt järgmised otsused: 1) Hankementluses
„Ruumikasutuse ja sisekliima monitooringu süsteem energiatarbimise optimeerimiseks“
viitenumbriga 266125 tunnistati vastavaks Reminet OÜ pakkumus, mis vastas riigihanke
alusdokumentides esitatud tingimustele. 2) Hankementluses „Ruumikasutuse ja sisekliima
monitooringu süsteem energiatarbimise optimeerimiseks“ viitenumbriga 266125 tunnistati RHS
§ 114 lg 2 alusel mittevastavaks ja lükati tagasi Netbits OÜ ja Proekspert AS ühispakkumus, mis
ei vastanud riigihanke alusdokumentides esitatud tingimustele. Pakkumuse tagasilükkamise
põhjendused: Hankijal oli nõutud kliimaanduri puhul niiskuse mõõtmisel resolutsioon vähemalt
0.1 % RH, täpsus 25°C juures vähemalt +/-2% RH. Pakkuja poolt pakutava kliimaanduri
Milesight AM307 resolutsioon on niiskuse mõõtmisel 0.5% RH, täpsus 25°C juures ± 2% RH.
See tähendab, et pakutava anduri resolutsioon niiskuse mõõtmisel ei vasta hanke
alusdokumentides esitatud tingimustele, kuna pakkuja poolt pakutava anduri resolutsioon on
kehvem hankija nõutust (resolutsioon 0,5% on kehvem kui 0,1% RH). Hankijal oli nõutud CO2
mõõtmisel ulatus vähemalt 0-10000 ppm, täpsus vähemalt +/-50 ppm/+ /-3% loetust. Pakkuja
poolt pakutava kliimaanduri Milesight AM307 ulatus on 400 - 5000 ppm. See tähendab, et
pakutava anduri CO2 mõõteulatus ei vasta hanke alusdokumentides esitatud tingimustele, kuna
pakkuja poolt pakutava anduri mõõteulatus on väiksem hankija nõutust (mõõteulatus 400 - 5000
ppm on väiksem kui 0-10000 ppm) Eeltoodust tulenevalt tunnistab hankija RHS § 114 lg 2 alusel
pakkumuse mittevastavaks ja lükkab tagasi, kuna pakkumus ei vasta riigihanke
alusdokumentides esitatud tingimustele. Hankija ei saa ka antud mittevastavust lugeda RHS §
114 lg 2 teise lause alusel mittesisuliseks kõrvalekaldumiseks, kuna tegemist on anduri ühtede
põhifunktsioonidega ja mille puhul pakkuja pakutud andurite aktsepteerimine vähendaks hankija
jaoks saadava info täpsust ja ulatust. Hankija tehtud otsuste peale võivad isikud, kelle õigusi on
rikutud või huvisid kahjustatud, esitada vaidlustuse Rahandusministeeriumi juures asuvale
riigihangete vaidlustuskomisjonile riigihangete seaduses sätestatud korras. Teadet saab lugeda
registris hanke töölehel Teabevahetus - Sõnumid pakkujale.
https://riigihanked.riik.ee/rhr-web/#/procurement/6040100/communication/message/761849
Teavituse lisaandmed
Saaja:
OVE TÜKSAMMEL
E-post:
[email protected]
Koostatud:
17.07.2023 08:51
Saadetud:
17.07.2023 08:51
Loetud:
17.07.2023 10:24
Description
ERS CO2 is a sensor for measuring the indoor environment. It is enclosed in a
room sensor box and is designed to be wall mounted. ERS CO2 is completely
wireless and powered by two 3.6V AA lithium batteries. Inside you will find internal
sensors for measuring indoor CO2 levels, temperature, humidity, light, and motion.
Applications Product features
• Indoor environment measuring • LoRaWAN Certified CM
• Smart buildings • CO2 sensor
• Workplace management • Temperature sensor
• Room occupancy • Humidity sensor
• Light sensor
• Motion detection sensor (PIR)
• NFC for configuration
• Configuration over the air
Device Specifications
Mechanical specifications
Weight 80 g excluding batteries / 120 g including batteries
Dimensions 86 x 86 x 27 mm
Enclosure Plastic, PC/ABS
Operating conditions
Temperature 0 to 50 °C
Humidity 0 to 85% RH (non-condensing)
Device Power Supply
Battery Type 2 x 3.6V AA Lithium Batteries
Expected Battery Life <10 years (Depending on configurations and environment)
Device Logging Function
Sampling Interval Configurable via NFC and downlink configuration
Data Upload Interval Configurable via NFC and downlink configuration
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail:
[email protected] ǀ Web: www.elsys.se
Specifications in this document are subject to change without notice.
©Elektroniksystem i Umeå AB 2019
Radio / Wireless
Wireless Technology LoRaWAN® 1.0.3
Wireless Security LoRaWAN® End-to-End encryption (AES-CTR), Data Integrity Protection (AES-CMAC)
LoRaWAN Device Type Class A/C (configurable) End-device
Supported LoRaWAN® features OTAA, ABP, ADR, Adaptive Channel Setup
Supportet LoRaWAN® regions US902 – 928, EU863 – 870, AS923, AU915 – 928, KR920 – 923, RU864, IN865
Link Budget 137 dB (SF7) to 151 dB (SF12)
RF Transmit Power 14 dB / 20 dB (Region specific)
Data types
Type value Type Data size Comment
0x01 Temperature 2 -3276.5 °C → 3276.5 °C (Value of: 100 → 10.0 °C)
0x02 Humidity 1 0 – 100 %
0x04 Light 2 0 – 65535 Lux
0x05 Motion (PIR) 1 0 – 255 (Number of motion counts)
0x06 CO2 2 0 – 2000 ppm (Extended: 0 – 10000 ppm)
0x07 VDD (Battery voltage) 2 0 – 65535 mV
0x3D Debug information 4 Data depends on debug information
0x3E Sensor settings n Sensor setting sent to server at startup (first package). Sent on Port+1.
Sensors
Temperature
Resolution: 0.1 °C
Accuracy: ±0.2 °C (See figure 1)
Figure 1
Humidity
Resolution: 0.1 % RH
Accuracy at 25 °C: ± 2 % RH (See figure 2)
Accuracy of humidity over temperature: See figure 3
Figure 2
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail:
[email protected] ǀ Web: www.elsys.se
Specifications in this document are subject to change without notice.
©Elektroniksystem i Umeå AB 2019
Light
Range: 4 – 2000 LUX
Resolution: 1 LUX
Accuracy: ± 10 LUX
Figure 3
Motion (PIR)
Figure 4 - Detection pattern
Note:
There is a blanking time of 30 seconds of the PIR triggering after each PIR trig and
after each transmission. This is to reduce the risk of self-triggering from internal
events that could disturb the high sensitivity PIR circuits.
CO2
Range, calibrated: 0 – 2000 ppm Note:
Range, extended: 0 – 10000 ppm The CO2 sensor has an internal automatic calibration
Accuracy, calibrated: ± 50 ppm / ± 3% of reading routine. This routine calibrates the sensor to set 400
Accuracy, extended: ± 10% of reading ppm to the lowest value that has been read in the last
period of approximately 8 days. This means that in an 8
Accuracy is met at 10 – 40°C, 0 – 60%RH, after minimum day period, the sensor must be exposed to fresh (well
three (3) performed Automatic Baseline. Corrections, ventilated) air at least once for the calibration to work.
preferably spanning eight (8) days in-between, or a The sensor can also be manually calibrated.
successful zero-calibration
Noise: 14 ppm at 400 ppm / 25 ppm at 1000 ppm
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail:
[email protected] ǀ Web: www.elsys.se
Specifications in this document are subject to change without notice.
©Elektroniksystem i Umeå AB 2019
Machine Translated by Google
Kirjeldus
ERS CO2 on andur sisekeskkonna mõõtmiseks. See on suletud ruumianduri
karpi ja on mõeldud seinale kinnitamiseks. ERS CO2 on täiesti juhtmevaba
ja toiteallikaks on kaks 3,6 V AA liitiumakut. Seest leiate sisemised andurid
siseruumide CO2 taseme, temperatuuri, niiskuse, valguse ja liikumise mõõtmiseks.
Rakendused Toote omadused
• Sisekeskkonna mõõtmine • LoRaWAN sertifitseeritud CM
• Targad hooned • CO2 andur
• Töökoha juhtimine • Temperatuuriandur
• Toa täituvus • Niiskuseandur
• Valgusandur
• Liikumistuvastusandur (PIR)
• NFC konfigureerimiseks
• Konfiguratsioon õhu kaudu
Seadme spetsifikatsioonid
Mehaanilised näitajad
Kaal 80 g ilma patareideta / 120 g koos patareidega
Mõõtmed 86 x 86 x 27 mm
Korpus Plastik, PC/ABS
Töötingimused
Temperatuur 0 kuni 50 °C
Niiskus 0 kuni 85% suhteline õhuniiskus (mittekondenseeriv)
Seadme toiteallikas
aku tüüp 2 x 3,6 V AA liitiumakud
Eeldatav aku tööiga <10 aastat (olenevalt konfiguratsioonist ja keskkonnast)
Seadme logimise funktsioon
Proovivõtu intervall Konfigureeritav NFC ja allalingi konfiguratsiooni kaudu
Andmete üleslaadimise intervall Konfigureeritav NFC ja allalingi konfiguratsiooni kaudu
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Rootsi
E-post:
[email protected] ÿ Veebileht: www.elsys.se
Selle dokumendi spetsifikatsioone võidakse ette teatamata muuta.
©Elektroniksystem i Umeå AB 2019
Machine Translated by Google
Raadio / Juhtmeta
Juhtmevaba tehnoloogia LoRaWAN® 1.0.3
Traadita turvalisus LoRaWAN® end-to-end krüptimine (AES-CTR), andmete terviklikkuse kaitse (AES-CMAC)
LoRaWAN seadme tüüp Klass A/C (konfigureeritav) lõppseade
Toetatud LoRaWAN® funktsioonid OTAA, ABP, ADR, adaptiivse kanali seadistamine
Toetage LoRaWAN®-i piirkondi US902 – 928, EU863 – 870, AS923, AU915 – 928, KR920 – 923, RU864, IN865 137 dB (SF7) kuni 151
Lingi eelarve dB (SF12)
RF edastusvõimsus 14 dB / 20 dB (piirkonnapõhine)
Andmetüübid
Tüübi väärtus Tüüp Andmete suurus Kommentaar
0x01 Temperatuur 2 -3276,5 °C ÿ 3276,5 °C (väärtus: 100 ÿ 10,0 °C)
0x02 Niiskus 0–100 %
0x04 Valgus 12 0 – 65535 luksi
0x05 Liikumine (PIR) 1 0–255 (liigutuste arv)
0x06 CO2 2 0–2000 ppm (laiendatud: 0–10000 ppm)
0x07 VDD (aku pinge) 2 0 – 65535 mV
0x3D Silumisinfo 4 Andmed sõltuvad silumisinfost
0x3E Anduri seaded n Anduri seadistus saadeti serverile käivitamisel (esimene pakett). Saadetud Port+1 kaudu.
Andurid
Temperatuur
Eraldusvõime: 0,1 °C
Täpsus: ±0,2 °C (vt joonis 1)
Joonis 1
Niiskus
Eraldusvõime: 0,1% RH
Täpsus 25 °C juures: ± 2 % suhteline õhuniiskus (vt joonis 2)
Niiskuse täpsus üle temperatuuri: vt joonis 3
Joonis 2
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Rootsi
E-post:
[email protected] ÿ Veebileht: www.elsys.se
Selle dokumendi spetsifikatsioone võidakse ette teatamata muuta.
©Elektroniksystem i Umeå AB 2019
Machine Translated by Google
Valgus
Vahemik: 4 – 2000 LUX
Eraldusvõime: 1 LUX
Täpsus: ± 10 LUX
Joonis 3
Liikumine (PIR)
Joonis 4 – tuvastusmuster
Märge:
Pärast iga PIR-käivitust ja pärast iga edastust on PIR-i käivitusaeg 30 sekundit. Selle eesmärk on
vähendada iseenesliku käivitumise ohtu sisemiste sündmuste tõttu, mis võivad häirida kõrge
tundlikkusega PIR-ahelaid.
CO2
Märge:
Vahemik, kalibreeritud: 0 – 2000 ppm
CO2 anduril on sisemine automaatne kalibreerimine
Vahemik, laiendatud: 0 – 10000 ppm
rutiin. See rutiin kalibreerib anduri väärtusele 400
Täpsus, kalibreeritud: ± 50 ppm / ± 3% näidust
Täpsus, laiendatud: ± 10% näidust ppm madalaima väärtuseni, mis on loetud viimase ligikaudu 8
päeva jooksul. See tähendab, et 8-päevase perioodi jooksul peab
Täpsus on 10–40
kolmel
°C, 0–60% suhteline õhuniiskus, pärast minimaalset täitmist andur olema värske (hästi
(3) sooritatud automaatsel baasjoonel. Parandused, eelistatavalt
ventileeritud) õhku vähemalt üks kord, et kalibreerimine toimiks.
kaheksa (8) päeva vahel, edukas nullkalibreerimine või a
Andurit saab ka käsitsi kalibreerida.
Müra: 14 ppm 400 ppm juures / 25 ppm 1000 ppm juures
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Rootsi
E-post:
[email protected] ÿ Veebileht: www.elsys.se
Selle dokumendi spetsifikatsioone võidakse ette teatamata muuta.
©Elektroniksystem i Umeå AB 2019
AM300 Series Datasheet
In d o o r Am b i e n c e
Mo n i t o r i n g S e n s o r
Featuring LoRaWAN®
AM300 Series
Introduction
AM300 series is a compact indoor ambience monitoring sensor for
measurement of temperature, humidity, light, CO2 concentration,
HCHO/O3 level, TVOC, barometric pressure, PM2.5, PM10 and
motion. The data will be shown on the E-ink screen in real-time,
which helps to measure the indoor environment and comfort. AM300
series is widely used for offices, stores, classrooms, hospitals, etc.
Sensor data is transmitted using LoRaWAN® technology. Combining
Milesight LoRaWAN® gateway and Milesight IoT Cloud, users can
manage all sensor data remotely and visually.
Features
Integrated with multiple sensors like humidity, temperature, CO2, light, barometric pressure,
PM2.5, PM10, etc.
Multiple display modes and clear emoticon to easily understand the comfort levels via screen
Support batteries or DC power supply
Equipped with traffic light indicator and buzzer to indicate device status and threshold alarms
Store locally 18, 000 historical records and support retransmission to prevent data loss
Compliant with standard LoRaWAN® gateways and network servers
Quick and easy management with Milesight IoT Cloud
AM300 Series Datasheet
Specifications
Model AM307 AM308 AM319
Wireless Transmission
Technology LoRaWAN®
Frequency CN470/RU864/IN865/EU868/US915/AU915/KR920/AS923-1&2&3&4
Tx Power 16dBm(868MHz)/22dBm(915MHz)/19dBm(470MHz)
Sensitivity -137dBm @300bps
Work Mode OTAA/ABP Class A OTAA/ABP Class A OTAA/ABP Class C
Sensors
Temperature
Operating Principle Digital CMOSens® technology (MEMS)
Range -20°C - 60°C
Accuracy1 ± 0.2°C
Resolution 0.1°C
Humidity
Operating Principle Digital CMOSens® technology (MEMS)
Range 0% - 100% RH
Accuracy ± 2% RH
Resolution 0.5% RH
Motion
Operating Principle Passive infrared (PIR)
Detection Range 80 ° Horizontal, 55 ° Vertical, 5m
Status Vacant/Occupied
Light
Operating Principle Photodiode
Range 0-60000 Lux (Determine as 6 levels, 0-5)
TVOC
Operating Principle MOX (MEMS)
Range1 1.00 - 5.00 (IAQ Rating)
Accuracy ±1
Resolution 0.01
Barometric Pressure
Operating Principle Piezoresistive absolute pressure sensor (MEMS)
Range 260 - 1260 hPa
AM300 Series Datasheet
Accuracy ±0.5 hPa
Resolution 0.1 hPa
Carbon Dioxide (CO2)
Operating Principle Nondispersive Infrared (NDIR) Photoacoustic
Range 400 - 5000 ppm 400 - 2000 ppm
± (30 ppm + 3 % of reading) ± (50 ppm + 5 % of reading)
Accuracy
(0°C to +50°C) (-10°C to +60°C)
Resolution 1 ppm 1 ppm
PM2.5 & PM10
Operating Principle — Laser Scattering
Range — 0 - 1000 μg/m3
0-100(±10μg/m3), 100-1000(±10 %)
Accuracy —
(-10°C to +60°C)
Resolution — 1 μg/m3
Formaldehyde (HCHO)2
Operating Principle — — Electrochemical
Range3 — — 0 - 1.25 mg/m3
Accuracy — — ±10 %
Resolution — — 0.01 mg/m3
Working Life 6 Years
Ozone (O3)2
Operating Principle — — Electrochemical
Range — — 0 - 10 ppm
Accuracy — — ±5 % FS
Resolution — — 0.01 ppm
Working Life 2 Years
Display & Configuration
Display 4.2-inch Black & White E-Ink Screen
Button 1 × Power Button + 1 × Reset Button
LED & Buzzer 1 × Traffic Light Status Indicator + 1 × Buzzer
1. Mobile App via NFC
Configuration
2. PC software via NFC or USB Type-C port
Physical Characteristics
1. 4 × 2700 mAh ER14505 Li-SOCl2 Replaceable
Power Supply 5V/1A by Type-C Port
Batteries
AM300 Series Datasheet
2. 5V/1A by Type-C Port
Battery Life4
Around 3 Years Over 1 Year —
(10 min interval)
Operating Temperature -20°C - 60°C (E-Ink Screen: 0°C - 40°C)
Relative Humidity 10% - 90% (non-condensing)
Ingress Protection IP30
Dimension 100.8 × 114 × 22 mm (3.97 × 4.49 × 0.87 in)
Installation 3M Tape Mounting, Wall Screw Mounting, 86 Box Mounting
Approvals
Regulatory CE, FCC
Environmental RoHS
Note:
1. Reference to IAQ rating guideline (conversion from mg/m3 to ppm by the factor is about 0.5):
IAQ Rating TVOC (mg/m3) Air Quality
≤1.99 <0.3 Very Good
2.00 to 2.99 0.3 to 1.0 Good
3.00 to 3.99 1.0 to 3.0 Medium (not recommended for exposure > 12 months)
4.00 to 4.99 3.0 to 10.0 Poor (not recommended for exposure > 1 months)
≥5.00 >10.0 Bad (not recommended)
2. HCHO or O3 sensor is alternative option and both support replacement.
3. For HCHO at 760 mmHg and 20°C, 1 ppm = 1.25 mg/m3.
4. The battery life is tested under laboratory conditions and for guideline purposes only.
Machine Translated by Google
AM300 seeria andmeleht
Sisekeskkona
Jälgimisandur
Kasutab LoRaWAN ®
AM300 seeria
Sissejuhatus
AM300 seeria on kompaktne sisekeskkonna jälgimise andur
temperatuuri, niiskuse, valguse, CO2 kontsentratsiooni mõõtmine ,
HCHO/O3 tase, TVOC, õhurõhk, PM2,5, PM10 ja
liikumine. Andmed kuvatakse E-tindi ekraanil reaalajas,
mis aitab mõõta sisekeskkonda ja mugavust. AM300
seeriat kasutatakse laialdaselt kontorites, kauplustes, klassiruumides, haiglates jne.
Anduri andmed edastatakse LoRaWANi ® tehnoloogiaga. Kombineerides
Milesight LoRaWAN® tugijaama ja Milesight IoT Cloudi, saavad kasutajad
hallata kõiki andurite andmeid eemalt ja visuaalselt.
Omadused
Integreeritud mitme anduriga, nagu niiskus, temperatuur, CO2, valgus, õhurõhk,
PM2,5, PM10 jne.
Mitu kuvarežiimi ja selge emotikon, et ekraani kaudu hõlpsasti mõista mugavuse taset
Toetage patareisid või alalisvoolu toiteallikat
Varustatud valgusfoori indikaatori ja sumistiga, mis näitab seadme olekut ja läve häireid
Salvestage kohapeal 18 000 ajaloolist kirjet ja toetage andmete kadumise vältimiseks uuesti edastamist
Ühildub standardsete LoRaWAN®- lüüside ja võrguserveritega
Kiire ja lihtne haldamine Milesight IoT Cloudiga
Machine Translated by Google
AM300 seeria andmeleht
Tehnilised andmed
Mudel AM307 AM308 AM319
Juhtmeta edastus
Tehnoloogia LoRaWAN ®
Sagedus CN470/RU864/IN865/EU868/US915/AU915/KR920/AS923-1&2&3&4
Tx võimsus 16 dBm (868 MHz) / 22 dBm (915 MHz) / 19 dBm (470 MHz)
Tundlikkus -137 dBm @ 300 bps
Töörežiim OTAA/ABP klass A OTAA/ABP klass A OTAA/ABP klass C
Andurid
Temperatuur
Tööpõhimõte Digital CMOSens® tehnoloogia (MEMS)
Vahemik -20°C - 60°C
1 ± 0,2 °C
Täpsus
Resolutsioon 0,1 °C
Niiskus
Tööpõhimõte Digital CMOSens® tehnoloogia (MEMS)
Vahemik 0% - 100% RH
Täpsus ± 2% RH
Resolutsioon 0,5% RH
Liikumine
Tööpõhimõte Passiivne infrapuna (PIR)
Tuvastamisulatus 80 ° horisontaalne, 55 ° vertikaalne, 5 m
Olek Vaba/hõivatud
Valgus
Tööpõhimõte Fotodiood
Vahemik 0–60 000 luksi (määrata 6 tasemena, 0–5)
TVOC
Tööpõhimõte MOX (MEMS)
1
Vahemik 1.00–5.00 (IAQ reiting)
Täpsus ±1
Resolutsioon 0,01
Baromeetriline rõhk
Tööpõhimõte Piesoresistiivne absoluutrõhuandur (MEMS)
Vahemik 260 - 1260 hPa
Machine Translated by Google
AM300 seeria andmeleht
Täpsus ±0,5 hPa
Resolutsioon 0,1 hPa
Süsinikdioksiid (CO2)
Tööpõhimõte Mittedispersiivne infrapuna (NDIR) Fotoakustiline
Vahemik 400-5000 ppm 400-2000 ppm
± (30 ppm + 3 % näidust) ± (50 ppm + 5 % näidust)
Täpsus
(0°C kuni +50°C) (-10 °C kuni +60 °C)
Resolutsioon 1 ppm 1 ppm
PM2,5 ja PM10
—
Tööpõhimõte Laseri hajumine
—
Vahemik 0 - 1000 ÿg/m3
—
0-100 (±10 ÿg/m3 ), 100-1000 (±10 %)
Täpsus
(-10 °C kuni +60 °C)
—
Resolutsioon 1 ÿg/m3
Formaldehüüd (HCHO)2
— —
Elektrokeemiline
Tööpõhimõte
3 — —
Vahemik 0 - 1,25 mg/m3
— —
Täpsus ±10 %
— —
Resolutsioon 0,01 mg/m3
Tööelu 6 aastat
Osoon (O3)2
— —
Tööpõhimõte Elektrokeemiline
— —
Vahemik 0-10 ppm
— —
Täpsus ±5 % FS
— —
Resolutsioon 0,01 ppm
Tööelu 2 aastat
Ekraan ja konfiguratsioon
Ekraan 4,2-tolline mustvalge E-tindi ekraan
Nupp 1 × toitenupp + 1 × lähtestusnupp
LED ja helisignaal 1 × valgusfoori oleku indikaator + 1 × helisignaal
1. Mobiilirakendus NFC kaudu
Seadistamine
2. Arvutitarkvara NFC või USB Type-C pordi kaudu
Füüsikalised omadused
1. 4 × 2700 mAh ER14505 Li-SOCl2 vahetatav
Toiteallikas 5V/1A C-tüüpi pordi kaudu
Patareid
Machine Translated by Google
AM300 seeria andmeleht
2. 5V/1A C-tüüpi pordi kaudu
Aku tööiga 4
Umbes 3 aastat Üle 1 aasta —
(10 min intervall)
Töötemperatuur -20°C - 60°C (E-Ink ekraan: 0°C - 40°C)
Suhteline niiskus 10% - 90% (mittekondenseeriv)
Sissepääsu kaitse IP30
Mõõtmed 100,8 × 114 × 22 mm (3,97 × 4,49 × 0,87 tolli)
Paigaldamine 3M teipkinnitus, kruvikinnitus seinale, 86 kastikinnitus
Heakskiidud
Reguleerivad CE, FCC
Keskkonna RoHS
Märge:
1. Viide IAQ reitingujuhisele (mg/m3 teisendus ppm-ks teguri järgi on umbes 0,5):
IAQ reiting TVOC (mg/m3 ) Õhu kvaliteet
1,99 <0.3 Väga hea
2.00 kuni 2.99 0,3 kuni 1,0 Hea
3.00 kuni 3.99 1,0 kuni 3,0 Keskmine (ei ole soovitatav kokkupuutel üle 12 kuu)
4.00 kuni 4.99 3,0 kuni 10,0 Kehv (ei ole soovitatav kokkupuuteks üle 1 kuu)
5.00 >10,0 Halb (pole soovitatav)
2. HCHO või O3 andur on alternatiivne võimalus ja mõlemad toetavad asendamist.
3. HCHO puhul 760 mmHg ja 20 °C juures 1 ppm = 1,25 mg/m3 .
4. Aku tööiga on testitud laboritingimustes ja ainult soovituslikel eesmärkidel.
SHT4x
4th Generation, High-Accuracy, Ultra-Low-Power, 16-bit
Relative Humidity and Temperature Sensor
Features
• Relative humidity accuracy: up to ±1.0 %RH • Operating range: 0…100 %RH, -40…125 °C
• Temperature accuracy: up to ±0.1 °C • Fully functional in condensing environment
• Supply voltage: 1.08 V … 3.6 V • Variable power heater
• Average current: 0.4 µA (at meas. rate 1 Hz) • NIST traceability
• Idle current: 80 nA • JEDEC JESD47 qualification
• I2C FM+, CRC checksum, multip. I2C addr. • Mature technology from global market leader
• Patented on-package PTFE membrane [1] • Removable protection cap
General Description
SHT4x is a digital sensor platform for measuring relative humidity and temperature at different
accuracy classes. Its I2C interface provides several preconfigured I2C addresses and maintains
an ultra-low power budget. The power-trimmed internal heater can be used at three heating
levels thus enabling sensor operation in demanding environments. The four-pin dual-flat-no-
leads package is suitable for surface mount technology (SMT) processing and comprises an
optional on-package patented PTFE [1] membrane or a removable protection cap.
Device Overview Functional Block Diagram
Products Details
SHT40-AD1B base RH&T accur., 0x44 I2C addr.
SHT40-BD1B base RH&T accur., 0x45 I2C addr.
add. patented on-package PTFE
SHT40-AD1F
membrane
SHT40-AD1P add. removable protection cap
SHT41-AD1B Intermed. RH&T accur., 0x44 I2C addr.
SHT45-AD1B ±1.0 %RH, ±0.1°C accur., 0x44 I2C addr. Full
product list on page 16
www.sensirion.com / D1 Version 3 – April 2022 1/18
Contents
1 Quick Start – Hello World ..................................................................................................................................... 3
2 Humidity and Temperature Sensor Specifications ....................................................................................... 4
2.1 Relative Humidity ............................................................................................................................................4
2.2 Temperature .....................................................................................................................................................6
2.3 Recommended Operating Conditions ......................................................................................................7
3 Electrical Specifications ........................................................................................................................................ 8
3.1 Electrical Characteristics ..............................................................................................................................8
3.2 Timings ...............................................................................................................................................................9
3.3 Absolute Maximum Ratings .........................................................................................................................9
4 Sensor Operation .................................................................................................................................................. 10
4.1 I2C communication.......................................................................................................................................10
4.2 I2C Communication Timing .......................................................................................................................10
4.3 Data type & length ........................................................................................................................................10
4.4 Checksum Calculation.................................................................................................................................10
4.5 Command Overview ....................................................................................................................................11
4.6 Conversion of Signal Output .....................................................................................................................11
4.7 Serial number .................................................................................................................................................12
4.8 Reset & Abort .................................................................................................................................................12
4.9 Heater Operation...........................................................................................................................................12
5 Physical Specification .......................................................................................................................................... 13
5.1 Package Description ....................................................................................................................................13
5.2 Package Outline ............................................................................................................................................13
5.3 Land Pattern ...................................................................................................................................................13
5.4 Pin Assignment & Laser Marking.............................................................................................................14
5.5 Thermal Information .....................................................................................................................................15
6 Quality and Material Contents........................................................................................................................... 15
7 Tape and Reel Packaging .................................................................................................................................. 15
8 Product Name Nomenclature ............................................................................................................................ 16
9 Ordering Information ............................................................................................................................................ 16
10 Bibliography.......................................................................................................................................................... 17
11 Revision History .................................................................................................................................................. 17
www.sensirion.com / D1 Version 3 – April 2022 2/18
1 Quick Start – Hello World
A typical application circuit for SHT4x is shown on the left-hand side of Figure 1. After reaching
the minimal supply voltage and allowing for the maximal power-up time of 1 ms the sensor is ready
for I2C communication. The quickest way to measure humidity and temperature is pseudo-coded
on the right-hand side of Figure 1. Together with the conversion formulae given in equations ( 1 ),
( 2 ), and ( 3 ), the digital signals can be translated into relative humidity and temperature readings.
Typical application circuit Pseudo code
i2c_write(i2c_addr=0x44, tx_bytes=[0xFD])
wait_seconds(0.01)
rx_bytes = i2c_read(i2c_addr=0x44,
number_of_bytes=6)
t_ticks = rx_bytes[0] * 256 + rx_bytes[1]
checksum_t = rx_bytes[2]
rh_ticks = rx_bytes[3] * 256 + rx_bytes[4]
checksum_rh = rx_bytes[5]
t_degC = -45 + 175 * t_ticks/65535
rh_pRH = -6 + 125 * rh_ticks/65535
if (rh_pRH > 100):
rh_pRH = 100
if (rh_pRH < 0):
rh_pRH = 0
Figure 1: Typical application circuit (left) and pseudo code (right) for easy starting. For details on
the signal cropping in the last four lines see section 4.6.
Find code resources and embedded drivers on: https://github.com/Sensirion/embedded-
sht/releases
CAD files can be downloaded from SnapEDA: https://www.snapeda.com/search/?q=sht4%3F-
&search-type=parts
www.sensirion.com / D1 Version 3 – April 2022 3/18
2 Humidity and Temperature Sensor Specifications
Every SHT4x is individually tested and calibrated and is identifiable by its unique serial number
(see section 4.7 for details on the serial number). For the calibration, Sensirion uses transfer
standards, which are subject to a scheduled calibration procedure. The calibration of the reference,
used for the calibration of the transfer standards, is NIST traceable through an ISO/IEC 17025
accredited laboratory.
2.1 Relative Humidity
Parameter Conditions Value Units
typ. 1.8 %RH
SHT40 RH accuracy1
max. see Figure 2 -
typ. 1.8 %RH
SHT41 RH accuracy1
max. see Figure 3 -
typ. 1.0 %RH
SHT45 RH accuracy1
max. see Figure 4 -
high 0.08 %RH
Repeatability2, 3 medium 0.15 %RH
low 0.25 %RH
Resolution4 - 0.01 %RH
Hysteresis At 25°C 0.8 %RH
Specified range5 extended6 0 to 100 %RH
Response time7 t63% 4 s
Long-term drift8 typ. <0.2 %RH/y
Table 1: General relative humidity sensor specifications.
1 For definition of typ. and max. accuracy, please refer to the document “Sensirion Humidity Sensor Specification Statement”.
2 The stated repeatability is 3 times the standard deviation (3σ) of multiple consecutive measurement values at constant conditions and is a measure for the noise
on the physical sensor output. Different repeatability commands are listed in Table 7.
3 Valid for 25°C and 50%RH.
4 Resolution of A/D converter.
5 Specified range refers to the range for which the humidity or temperature sensor specification is guaranteed.
6 For details about recommended humidity and temperature operating range, please refer to section 0.
7 Time for achieving 63% of a humidity step function, measured at 25°C and 1 m/s airflow. Humidity response time in the application depends on the design-in of the
sensor.
8 Typical value for operation in normal RH/T operating range. Value may be higher in environments with vaporized solvents, out-gassing tapes, adhesives, packaging
materials, etc. For more details please refer to Handling Instructions.
www.sensirion.com / D1 Version 3 – April 2022 4/18
Relative Humidity Accuracy
DRH (%RH) DRH (%RH)
±8 ±8
SHT40 typ SHT41 typ
±6 ±6
SHT40 max SHT41 max
±4 ±4
±2 ±2
±0 ±0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Relative Humidity (%RH) Relative Humidity (%RH)
Figure 2: SHT40 typical and maximal relative Figure 3: SHT41 typical and maximal relative
humidity accuracy at 25 °C. humidity accuracy at 25 °C.
DRH (%RH)
±8
SHT45 typ
±6
SHT45 max
±4
±2
±0
0 10 20 30 40 50 60 70 80 90 100
Relative Humidity (%RH)
Figure 4: SHT45 typical and maximal relative humidity accuracy at 25 °C
Relative Humidity Accuracy at the Extended Temperature Range
The typical RH accuracy tolerances in the range of T = 0°C … 80 °C are given in Figure 5, Figure
6 and Figure 7.
SHT40 |typ. Delta %RH| SHT41 |typ. Delta %RH|
100 3 100
90 90 2
Relative Humidity (%RH)
Relative Humidity (%RH)
2
80 80
70 70
60 60
50 1.8 50 1.8
40 40
30 30
20 20
2
10 10 2
0 3 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
Temperature (°C) Temperature (°C)
Figure 5: Typical RH accuracy tolerance over Figure 6: Typical RH accuracy tolerance over
humidity and temperature for SHT40. humidity and temperature for SHT41.
www.sensirion.com / D1 Version 3 – April 2022 5/18
SHT45 |typ. Delta %RH|
100 1.75
90
Relative Humidity (%RH)
1.5
80
70
60
50
1
40
30
20
10 1.5
0
0 10 20 30 40 50 60 70 80
Temperature (°C)
Figure 7: Typical RH accuracy tolerance over humidity and temperature for SHT45.
2.2 Temperature
Parameter Conditions Value Units
typ. 0.2 °C
SHT40 T Accuracy1
max. see Figure 8 -
typ. 0.2 °C
SHT41 T Accuracy1
max. see Figure 9 -
typ. 0.1 °C
SHT45 T Accuracy1
max. see Figure 10 -
high 0.04 °C
Repeatability2 medium 0.07 °C
low 0.1 °C
Resolution4 - 0.01 °C
Specified range5 - –40 to +125 °C
Response time9 t63% 2 s
Long-term drift10 typ. <0.03 °C/y
Table 2: General temperature sensor specifications.
9 Temperature response time depends on heat conductivity of sensor substrate and design-in of sensor in application.
10 Max. value is < 0.04°C/y.
www.sensirion.com / D1 Version 3 – April 2022 6/18
Temperature Accuracy
DT (°C) DT (°C)
±1.0 ±1.0
SHT40 typ SHT41 typ
±0.8 ±0.8
SHT40 max SHT41 max
±0.6 ±0.6
±0.4 ±0.4
±0.2 ±0.2
±0.0 ±0.0
-40 -20 0 20 40 60 80 100 120 -40 -20 0 20 40 60 80 100 120
Temperature (°C) Temperature (°C)
Figure 8: SHT40 typical and maximal temperature Figure 9: SHT41 typical and maximal temperature
accuracy. accuracy.
DT (°C)
±1.0
±0.8 SHT45 typ
SHT45 max
±0.6
±0.4
±0.2
±0.0
-40 -20 0 20 40 60 80 100 120
Temperature (°C)
Figure 10: SHT45 typical and maximal temperature accuracy.
2.3 Recommended Operating Conditions
The sensor shows best performance when operated within the recommended normal temperature
and humidity range of 5 °C … 60 °C and 20 %RH … 80 %RH, respectively. Long term exposure to
conditions outside recommended normal range, especially at high relative humidity, may
temporarily offset the RH signal (e.g. +3 %RH after 60 h at > 80 %RH). After returning into the
recommended normal temperature and humidity range the sensor will recover to within
specifications by itself. Prolonged exposure to extreme conditions may accelerate ageing.
To ensure stable operation of the humidity sensor, the conditions described in the document [2]
regarding exposure to volatile organic compounds must be met. Please note as well that this does
apply not only to transportation and manufacturing, but also to operation of the SHT4x.
www.sensirion.com / D1 Version 3 – April 2022 7/18
3 Electrical Specifications
Valid for all electrical specifications: Typical values correspond to VDD = 3.3 V and T = 25 °C. Min.
and max. values are valid in the full temperature range -40 °C … 125 °C and at declared VDD levels
and are based on characterization.
3.1 Electrical Characteristics
Parameter Symbol Conditions Min Typ Max Unit Comments
Supply
VDD 1.08 3.3 3.6 V -
voltage
Power- VPOR Static power supply
0.6 - 1.08 V -
up/down level
Voltage changes on the
Slew rate of
supply between VDD, min
the supply VDD, slew - - 20 V/ms
and VDD, max. Faster slew
voltage
rates may lead to a reset
- 0.08 1.0 µA At 25°C
Idle state
- - 3.4 At 125°C
Power up - 50 - µA -
Current while sensor is
Supply current Measurement - 320 500 µA
IDD measuring
(no heater) Aver., high repeatability - 2.2 -
Aver. current consumption
Aver., med. repeatability - 1.2 - µA (continuous operation with
one meas. per second)
Aver., low repeatability - 0.4 -
Aver., high repeatability - 2.6 -
Power
Aver. power consumption
consumpt. at
- Aver., med. repeatability - 1.4 - µW (continuous operation with
VDD=1.2V
one meas. per second)
(no heater)
Aver., low repeatability - 0.5 -
Low level 0.3* -
VIL - 0 - V
input voltage VDD
High level 0.7* -
VIH - - VDD V
input voltage VDD
Pull up VDD < 1.62 V 820 - - Ω -
Rp
resistors VDD ≥ 1.62 V 390 - - Ω -
VDD < 1.62V, 0.2*
- - V -
Rpullup > 820 Ω VDD
Low level VDD = 1.62V … 2.0V, 0.2*
VOL - - V -
output voltage Rpullup > 390 Ω VDD
VDD > 2.0V,
- - 0.4 V -
Rpullup > 390 Ω
Capacitive bus load can be
RP ≤ 820 Ω: fast mode - - 400 pF determined from
Cb < trise /(0.8473*Rp).
Capacitive
Cb Rise times are trise = 300 ns
bus load Rp = 390 Ω,
for fast mode and
VDD > 1.62 V: fast - - 340 pF trise = 120 ns for fast mode
mode plus
plus
Table 3: Electrical specifications.
www.sensirion.com / D1 Version 3 – April 2022 8/18
3.2 Timings
Max. values are measured at -40°C and 1.08 V supply voltage (based on characterization).
Parameter Symbol Conditions Min. Typ. Max. Units Comments
Time between VDD
After hard reset, reaching VPOR and
Power-up time tPU - 0.3 1 ms
VDD ≥ VPOR sensor entering idle
state
Time between ACK of
soft reset command and
Soft reset time tSR After soft reset - - 1 ms sensor entering idle
state. Also valid for I2C
general call reset.
Low Including tPU:
tMEAS,l - 1.3 1.6 ms
repeatability The three repeatability
Measurement Med. modes differ with
tMEAS,m - 3.7 4.5 ms
duration repeatability respect to measurement
High duration, noise level and
tMEAS,h - 6.9 8.3 ms energy consumption
repeatability
After that time the heater
Long pulse 0.9 1 1.1 s is automatically switched
off
Heater-on duration tHeater
After that time the heater
Short pulse 0.09 0.1 0.11 s is automatically switched
off
Table 4 System timing specifications.
3.3 Absolute Maximum Ratings
Stress levels beyond those listed in Table 5 may cause permanent damage or affect the reliability
of the device. These are stress ratings only and functional operation of the device at these
conditions is not guaranteed. Ratings are only tested each at a time.
Parameter Rating
Max. voltage on any pin VSS - 0.3 V … VDD + 0.3 V
Operating temperature range -40 °C … 125 °C
Storage temperature range11 -40 °C …150 °C
ESD HBM 2 kV
ESD CDM 500 V
Latch up, JESD78 Class II, 125°C +-100 mA
Table 5: Absolute maximum ratings.
11 The recommended storage temperature range is 10-50°C. Please consult the document “SHTxx Handling Instructions” for more information.
www.sensirion.com / D1 Version 3 – April 2022 9/18
4 Sensor Operation
4.1 I2C communication
I2C communication is based on NXP’s I2C-bus specification and user manual UM10204, Rev.6, 4
April 2014. Supported I2C modes are standard, fast mode, and fast mode plus. Data is transferred
in multiples of 16-bit words and 8-bit checksum (cyclic redundancy check = CRC). All transfers
must begin with a start condition (S) and terminate with a stop condition (P). To finish a read
transfer, send not acknowledge (NACK) and stop condition (P). Addressing a specific slave device
is done by sending its 7-bit I2C address followed by an eighth bit, denoting the communication
direction: “zero” indicates transmission to the slave, i.e. “write”, a “one” indicates a “read” request.
Schematics of the I2C transfer types are sketched in Error! Reference source not found.. The
sensor does not support clock-stretching. In case the sensor receives a read header and is still
busy with e.g. measurement or heating, it will return a NACK. Measurement data can only be
received once and will be deleted from the sensor’s register after the first acknowledged I2C read
header.
Figure 11: I2C transfer types: First a write header is sent to the I2C slave, followed by a command, for
example “measure RH&T with highest precision”. After the measurement is finished the read request directed
to this I2C slave will be acknowledged and transmission of data will be started by the slave.
4.2 I2C Communication Timing
All details on the timing are following the interface specification of NXP’s user manual UM10204,
Rev.6, 4 April 2014. Please follow mandatory capacitor and resistor requirements given in Table
3.
4.3 Data type & length
I2C bus operates with 8-bit data packages. Information from the sensor to the master has a
checksum after every second 8-bit data package.
Humidity and temperature data will always be transmitted in the following way: The first value is
the temperature signal (2 * 8-bit data + 8-bit CRC), the second is the humidity signal (2 * 8-bit data
+ 8-bit CRC).
4.4 Checksum Calculation
For read transfers each 16-bit data is followed by a checksum with the following properties
Property Value
Name CRC-8
Message Length 16-bit
Polynomial 0x31 (x8 + x5 + x4 +1)
Initialization 0xFF
Reflect Input/Output false/false
Final XOR 0x00
Examples CRC(0xBEEF) = 0x92
Table 6 Data checksum properties.
The master may abort a read transfer after the 16-bit data if it does not require a checksum.
www.sensirion.com / D1 Version 3 – April 2022 10/18
4.5 Command Overview
Command Response length Description
(hex) incl. CRC (bytes) [return values]
0xFD 6 measure T & RH with high precision (high repeatability)
[2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC]
0xF6 6 measure T & RH with medium precision (medium repeatability)
[2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC]
0xE0 6 measure T & RH with lowest precision (low repeatability)
[2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC]
0x89 6 read serial number
[2 * 8-bit data; 8-bit CRC; 2 * 8-bit data; 8-bit CRC]
soft reset
0x94 -
[ACK]
activate heater with 200mW for 1s, including a high precision
0x39 6 measurement just before deactivation
[2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC]
activate heater with 200mW for 0.1s including a high precision
0x32 6 measurement just before deactivation
[2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC]
activate heater with 110mW for 1s including a high precision
0x2F 6 measurement just before deactivation
[2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC]
activate heater with 110mW for 0.1s including a high precision
0x24 6 measurement just before deactivation
[2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC]
activate heater with 20mW for 1s including a high precision
0x1E 6 measurement just before deactivation
[2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC]
activate heater with 20mW for 0.1s including a high precision
0x15 6 measurement just before deactivation
[2 * 8-bit T-data; 8-bit CRC; 2 * 8-bit RH-data; 8-bit CRC]
Table 7 Overview of I2C commands. If the sensor is not ready to process a command, e.g. because it is still
measuring, it will response with NACK to the I2C read header. Given heater power values are typical and
valid for VDD=3.3V.
4.6 Conversion of Signal Output
The digital sensor signals correspond to following humidity and temperature values:
𝑆𝑅𝐻
𝑅𝐻 = (−6 + 125 ∙ 16 ) %RH (1)
2 −1
𝑆𝑇
𝑇 = (−45 + 175 ∙ 16 ) °C (2)
2 −1
𝑆𝑇
𝑇 = (−49 + 315 ∙ 16 ) °F (3)
2 −1
N.B.: The RH conversion formula (1) allows values to be reported which are outside of the range
of 0 %RH … 100 %RH. Relative humidity values which are smaller than 0 %RH and larger than
100 %RH are non-physical, however these “uncropped” values might be found beneficial in some
cases (e.g. when the distribution of the sensors at the measurement boundaries are of interest).
For all users who do not want to engage in evaluation of these non-physical values, cropping of
the RH signal to the range of 0 %RH … 100 %RH is advised.
www.sensirion.com / D1 Version 3 – April 2022 11/18
4.7 Serial number
Each sensor has a unique serial number, that is assigned by Sensirion during production. It is
stored in the one-time-programmable memory and cannot be manipulated after production. The
serial number is accessible via I2C command 0x89 and is transmitted as two 16-bit words, each
followed by an 8-bit CRC.
4.8 Reset & Abort
A reset of the sensor can be achieved in three ways:
• Soft reset: send the reset command described in Table 7.
• I2C general call reset: all devices on I2C bus are reset by sending the command 0x06 to
the I2C address 0x00.
• Power down (incl. pulling SCL and SDA low)
Any command that triggers an action at the sensor can be aborted via I2C general call reset or soft
reset.
4.9 Heater Operation
The sensor incorporates an integrated on-package heater which can be switched on by the set of
commands given in Table 7. Three heating powers and two heating durations are selectable. After
reception of a heater-on command, the sensor executes the following procedure:
1. The heater is enabled, and the timer starts its count-down.
2. On timer expiration a temperature and humidity measurement with the highest repeatability
is started, the heater remains enabled.
3. After the measurement is finished the heater is turned off.
4. Temperature and humidity values are now available for readout.
The maximum on-time of the heater commands is 1 second in order to prevent overheating of the
sensor by unintended usage of the heater. Thus, there is no dedicated command to turn off the
heater. For extended heating periods it is required to send periodic heater-on commands, keeping
in mind that the heater is designed for a maximal duty cycle of less than 10%. To obtain a fast
increase in temperature the idle time between consecutive heating pulses shall be kept minimal.
Possible Heater Use Cases
There will be dedicated Sensirion application notes elaborating on various use cases of the
heater. In general, the applications of the on-package heater range around:
1. Removal of condensed / spray water on the sensor surface. Although condensed water is
not a reliability / quality problem to the sensor, it will however make the sensor non-
responsive to RH changes in the air as long as there is liquid water on the surface.
2. Creep-free operation in high humid environments. Periodic heating pulses allow for creep-
free high-humidity measurements for extended times.
Important notes for operating the heater:
1. The heater is designed for a maximum duty cycle of 10%, meaning the total heater-on-time
should not be longer than 10% of the sensor’s lifetime.
2. During operation of the heater, sensor specifications are not valid.
3. The temperature sensor can additionally be affected by the thermally induced mechanical
stress, offsetting the temperature reading from the actual temperature.
4. The sensor’s temperature (base temperature + temperature increase from heater) must not
exceed Tmax = 125 °C in order to have proper electrical functionality of the chip.
5. The heater draws a large amount of current once enabled (up to ~75mA in the highest
power setting). Although a dedicated circuitry draws this current smoothly, the power supply
must be strong enough to avoid large voltage drops that could provoke a sensor reset.
www.sensirion.com / D1 Version 3 – April 2022 12/18
6. If higher heating temperatures are desired, consecutive heating commands have to be sent
to the sensor. The heater shall only be operated in ambient temperatures below 65°C else
it could drive the sensor outside of its maximal operating temperature.
5 Physical Specification
5.1 Package Description
SHT4x is provided in an open-cavity dual flat no lead (DFN) package. The humidity sensor opening
is centered on the top side of the package. The sensor chip is made of silicon, hosted on a copper
lead frame and overmolded by an epoxy-based mold compound. Exposed bottom side of the
leadframe with the metallic contacts is Ni/Pd/Au coated, side walls are bare copper.
Moisture sensitivity level (MSL) of 1 according to IPC/JEDEC J-STD-020 is achieved. It is
recommended to process the sensors within one year after date of delivery.
5.2 Package Outline
Figure 12 Dimensional drawing of SHT4x including package tolerances (units mm).
5.3 Land Pattern
The land pattern is recommended to be designed according to the used PCB and soldering process
together with the physical outer dimensions of the sensor. For reference, the land pattern used with
Sensirion’s PCBs and soldering processes is given in Figure 13.
Soldering of the central die pad is optional. Sensirion recommends to not solder the central die pad
because the sensor can reach higher temperatures upon heater activation.
www.sensirion.com / D1 Version 3 – April 2022 13/18
Figure 13: Recommended land pattern
(in mm). Details can vary and depend on
used PCBs and solder processes. There
shall be no copper under the sensor
other than at the pin pads.
5.4 Pin Assignment & Laser Marking
Pin Name Comments
1 SDA Serial data, bidirectional
2 SCL Serial clock, unidirectional input
3 VDD Supply voltage
4 VSS Ground
Figure 14 Pin assignment (transparent top view). Dashed lines are only visible if sensor is viewed from
below. The die pad is not directly connected to any pin.
The laser marking consists of two lines, indicated in Figure 14. In the first line a filled circle serves
as pin-1 indicator and is followed by “SH4”. The last character will indicate the accuracy class of
this product (here “x” serves as place holder). In the second line, the first three characters specify
the product characteristics according to positions 7, 8 and 9 of Table 9. The second three
characters serve as internal batch tracking code.
www.sensirion.com / D1 Version 3 – April 2022 14/18
5.5 Thermal Information
Heater off, die Heater on, die
Heater off, die Heater on, die
pad pad
Symbol Description pad soldered pad soldered
not soldered not soldered
(K/W) (K/W)
(K/W) (K/W)
Junction-to-ambient
𝑅𝜃𝐽𝐴 246 308 297 357
thermal resistance
Junction-to-case
𝑅𝜃𝐽𝐶 189 255 191 257
thermal resistance
Junction-to-board
𝑅𝜃𝐽𝐵 159 225 193 258
thermal resistance
Junction-to-board
Ψ𝐽𝐵 characterization 159 223 191 254
param.
Junction-to-top
Ψ𝐽𝑇 characterization 38 105 44 112
param.
Table 8 Typical values for thermal metrics. In the “heater on” columns a heater power of 200 mW was
assumed. Soldering of the die pad is not recommended, therefore the two right hand side columns are bold.
Values are based on simulation.
6 Quality and Material Contents
Qualification of SHT4x is performed based on the JEDEC JESD47 qualification test method,
qualification report available on request. The device is fully RoHS and WEEE compliant, e.g. free
of Pb, Cd, and Hg.
For general remarks of best practice in processing humidity sensor please refer to the handling
instructions [2].
7 Tape and Reel Packaging
All specifications for the tape and reel packaging can be found on Figure 15. Reel diameters are
13 inch and 8 inch for the 10k and the 2.5k packaging sizes, respectively.
Figure 15: Tape and reel specifications including sensor orientation in pocket (see indication of two sensors
on the right side of the tape).
www.sensirion.com / D1 Version 3 – April 2022 15/18
8 Product Name Nomenclature
position value(s) explanation
1 S Sensirion
2 H Humidity Signal
3 T Temperature Signal
4 4 Fourth product generation
0 Base accuracy
5 1 Intermediate accuracy
5 Best accuracy
6 - delimiter
A I2C interface with 0x44 address
7
B I2C interface with 0x45 address
8 D DFN package
9 1 reserved
B package without membrane
10 F Package with integrated, patented PTFE membrane
P Package with integrated, removable protection cap
11 - delimiter
12 R Tape on reel packaging
2 Packaging article contains 2’500 pieces
13
3 Packaging article contains 10’000 pieces
Table 9 SHT4x product name nomenclature.
9 Ordering Information
Material Description Material Number Details Quantity (pcs)
SHT40-AD1B-R2 3.000.465 base RH&T acc., 0x44 I2C addr. 2’500
SHT40-AD1B-R3 3.000.353 base RH&T acc., 0x44 I2C addr. 10’000
base RH&T acc., 0x44 I2C addr.,
SHT40-AD1F-R3 tbd including patented PTFE membrane 10’000
available Q3/22
base RH&T acc., 0x44 I2C addr.,
SHT40-AD1P-R3 tbd removable protection cap 10’000
available Q3/22
SHT40-BD1B-R2 3.000.492 base RH&T acc., 0x45 I2C addr. 2’500
SHT40-BD1B-R3 3.000.610 base RH&T acc., 0x45 I2C addr. 10’000
SHT41-AD1B-R2 3.000.466 intermed. RH&T acc., 0x44 I2C addr. 2’500
SHT41-AD1B-R3 3.000.611 intermed. RH&T acc., 0x44 I2C addr. 10’000
SHT45-AD1B-R2 3.000.645 ±1.0 %RH, ±0.1°C acc., 0x44 I2C addr. 2’500
SHT45-AD1B-R3 3.000.750 ±1.0 %RH, ±0.1°C acc., 0x44 I2C addr. 10’000
Table 10 SHT4x ordering options.
www.sensirion.com / D1 Version 3 – April 2022 16/18
10 Bibliography
[1] K. Ehrhorn, "A Humidity Sensor and a Methode for Manufacturing the Same.". UK, DE, FR, NL, DM, BE, US, CN
Patent EP1810013, US7741950, CN101040181, 2005.
[2] Sensirion, "Handling Instructions for Humidity Sensors," 2020.
11 Revision History
Date Version Page(s) Changes
October 2020 1 all Initial release
July 2021 2 multiple Typo correction
3 Included checksum in Figure 1
4 Included description of NIST traceability in section 2
4 Included repeatability clarification in Table 1
10 Clarified I2C communication in section 4.1
9 Removed waiting time specification in Table 4
12 Specified serial number in 4.7
15 Updated qualification status in section 6
11 Deleted binary com. & included return values in Table 7
12 Updated note on duty cycle of heater in section 4.9
12 Added note on large current drawn by heater in section 4.9
16 Updated ordering information in Table 10
April 2022 3 multiple Included SHT45 RH- and T-accuracy specifications
multiple Extended max. heater duty cycle to 10%
4 Reduced RH response time to 4s in Table 1
4 Reduced long-term drift to <0.2 %RH/y in Table 1
4 Reduced hysteresis to ±0.8%RH at 25°C in Table 1
9 Updated max. measurement times in Table 4
10 Included I2C communication timing in section 4.2
16 Introduced new product version in Table 9
16 Updated ordering information in Table 10
www.sensirion.com / D1 Version 3 – April 2022 17/18
Important Notices
Warning, Personal Injury
Do not use this product as safety or emergency stop devices or in any other application where failure of the product could result
in personal injury. Do not use this product for applications other than its intended and authorized use. Before installing, handling,
using or servicing this product, please consult the data sheet and application notes. Failure to comply with these instructions
could result in death or serious injury.
If the Buyer shall purchase or use SENSIRION products for any unintended or unauthorized application, Buyer shall defend, indemnify and
hold harmless SENSIRION and its officers, employees, subsidiaries, affiliates and distributors against all claims, costs, damages and
expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such
unintended or unauthorized use, even if SENSIRION shall be allegedly negligent with respect to the design or the manufacture of the product.
ESD Precautions
The inherent design of this component causes it to be sensitive to electrostatic discharge (ESD). To prevent ESD-induced damage and/or
degradation, take customary and statutory ESD precautions when handling this product. See application note “ESD, Latchup and EMC” for
more information.
Warranty
SENSIRION warrants solely to the original purchaser of this product for a period of 12 months (one year) from the date of delivery that this
product shall be of the quality, material and workmanship defined in SENSIRION’s published specifications of the product. Within such
period, if proven to be defective, SENSIRION shall repair and/or replace this product, in SENSIRION’s discretion, free of charge to the Buyer,
provided that:
• notice in writing describing the defects shall be given to SENSIRION within fourteen (14) days after their appearance;
• such defects shall be found, to SENSIRION’s reasonable satisfaction, to have arisen from SENSIRION’s faulty design, material, or
workmanship;
• the defective product shall be returned to SENSIRION’s factory at the Buyer’s expense; and
• the warranty period for any repaired or replaced product shall be limited to the unexpired portion of the original period.
This warranty does not apply to any equipment which has not been installed and used within the specifications recommended by SENSIRION
for the intended and proper use of the equipment. EXCEPT FOR THE WARRANTIES EXPRESSLY SET FORTH HEREIN, SENSIRION
MAKES NO WARRANTIES, EITHER EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCT. ANY AND ALL WARRANTIES,
INCLUDING WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE
EXPRESSLY EXCLUDED AND DECLINED.
SENSIRION is only liable for defects of this product arising under the conditions of operation provided for in the data sheet and proper use
of the goods. SENSIRION explicitly disclaims all warranties, express or implied, for any period during which the goods are operated or stored
not in accordance with the technical specifications.
SENSIRION does not assume any liability arising out of any application or use of any product or circuit and specifically disclaims any and all
liability, including without limitation consequential or incidental damages. All operating parameters, including without limitation recommended
parameters, must be validated for each customer’s applications by customer’s technical experts. Recommended parameters can and do
vary in different applications.
SENSIRION reserves the right, without further notice, (i) to change the product specifications and/or the information in this document and (ii)
to improve reliability, functions and design of this product.
Copyright © 2022, by SENSIRION. CMOSens® is a trademark of Sensirion. All rights reserved
Headquarters and Subsidiaries
Sensirion AG Sensirion Inc., USA Sensirion Korea Co. Ltd.
Laubisruetistr. 50 phone: +1 312 690 5858 phone: +82 31 337 7700~3
CH-8712 Staefa ZH
[email protected] [email protected]
Switzerland www.sensirion.com www.sensirion.com/kr
phone: +41 44 306 40 00 Sensirion Japan Co. Ltd. Sensirion China Co. Ltd.
fax: +41 44 306 40 30 phone: +81 3 3444 4940 phone: +86 755 8252 1501
[email protected] [email protected] [email protected]
www.sensirion.com www.sensirion.com/jp www.sensirion.com/cn
Sensirion Taiwan Co. Ltd
phone: +886 3 5506701
[email protected]
www.sensirion.com
To find your local representative, please visit www.sensirion.com/distributors
www.sensirion.com / D1 Version 3 – April 2022 18/18
SHT4x
4 _ põlvkond, Kõrge täpsus, Ülimadala võimsusega, 16-bitine
suhtelise niiskuse ja temperatuuri andur
Funktsioonid
• Sugulane niiskus täpsus: üles juurde ±1,0 • Töötavad vahemik: 0…100 %RH, -40…125 °C
%RH
• Täielikult funktsionaalne sisse
• Temperatuur täpsus: üles juurde ±0,1 °C kondenseerumine keskkond
• Pakkumine Pinge: 1.08 V … 3.6 V • Muutuv võimsus küttekeha
• Keskmine praegune: 0.4 µA (at mõõdud. • NIST jälgitavus
määra 1 Hz)
• JEDEC JESD47 kvalifikatsioon
• Tühikäik praegune: 80 nA
• Küpsed tehnoloogia alates globaalne turul juht
• I2C FM+, CRC kontrollsumma, korrutis. I2C
• Eemaldatav kaitse kork
adr.
• Patenteeritud pakendil PTFE membraan [1]
Kindral Kirjeldus
SHT4x on digitaalne anduriplatvorm suhtelise õhuniiskuse ja temperatuuri mõõtmiseks erineva
täpsusega klassid. Selle I2C liides annab mitu eelkonfigureeritud I2C aadressid ja säilitab
ülimadala võimsuse eelarve. Elektrilise trimmiga sisesoojendit saab kasutada kolmel
küttetasemel, võimaldades andurit töötada nõudlikes keskkondades. Nelja kontaktiga dual-flat-
no-lees pakett sobib pindpaigaldustehnoloogia (SMT) töötlemiseks ja sisaldab valikulist
pakendil patenteeritud PTFE [1] membraani või eemaldatavat kaitsekorki.
Seade Ülevaade Funktsionaalne Blokeeri
Diagramm
Products Details
SHT40-AD1B base RH&T accur., 0x44 I2C addr.
SHT40-BD1B base RH&T accur., 0x45 I2C addr.
add. patented on-package PTFE
SHT40-AD1F
membrane
SHT40-AD1P add. removable protection cap
SHT41-AD1B Intermed. RH&T accur., 0x44 I2C addr.
SHT45-AD1B ±1.0 %RH, ±0.1°C accur., 0x44 I2C addr. Täis
toode nimekirja peal
lehel 16
www.sensirion.com / D1 Version 3 – April 2022 1/25
Sisu
1 Kiiresti Alusta – Tere Maailm ........................................................................................................3
2 Niiskus ja Temperatuur Andur Tehnilised andmed .......................................................................4
2.1 Sugulane Niiskus .................................................................................................................. 4
2.2 Temperatuur ......................................................................................................................... 6
2.3 Soovitatav Töötavad Tingimused .......................................................................................... 7
3 Elektriline Tehnilised andmed .......................................................................................................8
3.1 Elektriline Omadused ............................................................................................................ 8
3.2 Ajad ....................................................................................................................................... 9
3.3 Absoluutne Maksimaalne Hinnangud .................................................................................... 9
4 Andur Operatsioon ...................................................................................................................... 10
4.1 I2C suhtlemine ..................................................................................................................... 10
4.2 I2C Suhtlemine Ajastus ........................................................................................................ 10
4.3 Andmed tüüp & pikkus ......................................................................................................... 10
4.4 Kontrollsumma Arvutus ........................................................................................................ 10
4.5 Käsk Ülevaade ..................................................................................................................... 11
4.6 Teisendamine kohta Signaal Väljund ................................................................................... 11
4.7 Sari number ......................................................................................................................... 12
4.8 Lähtesta & Katkesta ............................................................................................................. 12
4.9 Kütteseade Operatsioon ...................................................................................................... 12
5 Füüsiline Spetsifikatsioon ........................................................................................................... 13
5.1 pakett Kirjeldus .................................................................................................................... 13
5.2 pakett Ülevaade ................................................................................................................... 13
5.3 Maa Muster .......................................................................................................................... 13
5.4 Pin Ülesandmine & Laser Märgistus .................................................................................... 14
5.5 Soojus Teave ....................................................................................................................... 15
6 Kvaliteet ja Materjal Sisu ............................................................................................................ 15
7 Lint ja Rull Pakend ...................................................................................................................... 15
8 Toode Nimi Nomenklatuur .......................................................................................................... 16
9 Tellimine Teave .......................................................................................................................... 16
10 Bibliograafia .............................................................................................................................. 17
11 Läbivaatamine Ajalugu ............................................................................................................. 17
www.sensirion.com / D1 Version 3 – April 2022 2/25
1 Kiiresti Alusta – Tere Maailm
joonise 1 vasakpoolsel küljel . Pärast jõudmist minimaalne pakkumine Pinge ja lubades jaoks a
maksimaalne sisselülitamine aega kohta 1 Prl a andur on valmis I2C suhtluseks. Kiireim viis
niiskuse ja temperatuuri mõõtmiseks on sisse lülitatud pseudokood a parem käsi pool kohta
Joonis 1 . Koos koos a teisendamine valemid antud sisse võrrandid ( 1 ) , ( 2 ) , ja ( 3 ) , a
digitaalne signaale saab olla tõlgitud sisse sugulane niiskus ja temperatuuri näidud.
Tüüpiline rakendus vooluring Pseudo kood
i2c_write(i2c_addr=0x44, tx_bytes=[0xFD])
oota_sekundit(0,01)
rx_baiti = i2c_read(i2c_addr=0x44,
baitide_arv=6)
t_tiks = rx_bytes[0] * 256 + rx_bytes[1]
checksum_t = rx_bytes[2]
rh_tiks = rx_bytes[3] * 256 + rx_bytes[4]
checksum_rh = rx_bytes[5]
t_degC = -45 + 175 * t_ticks/65535
rh_pRH = -6 + 125 *
rh_ticks/65535, kui (rh_pRH >
100):
rh_pRH =
100, kui (rh_pRH <
0):
rh_pRH = 0
Joonis 1: Tüüpiline rakendusahel (vasakul) ja pseudokood (paremal) lihtsaks käivitamiseks.
Täpsemat teavet signaali kärpimise kohta neljal viimasel real vt jaotisest 4.6 .
Otsi kood ressursse ja manustatud autojuhid peal: https://github.com/Sensirion/embedded-
sht/releases _
CAD failid saab olla alla laaditud alates SnapEDA:
https://www.snapeda.com/search/?q=sht4%3F- &otsingutüüp=osad
www.sensirion.com / D1 Version 3 – April 2022 3/25
2 Niiskus ja Temperatuur Andur Tehnilised andmed
Iga SHT4x on individuaalselt testitud ja kalibreeritud ning see on identifitseeritav selle ainulaadse
seerianumbri järgi (vt seerianumbri üksikasju jaotisest 4.7 ). Kalibreerimiseks kasutab Sensirion
ülekandestandardeid, mis on teema juurde a planeeritud kalibreerimine menetlust. The
kalibreerimine kohta a ülekandestandardite kalibreerimiseks kasutatav viide on NIST-i jälgitav läbi
ISO/IEC 17025 akrediteeritud labori.
2.1 Sugulane Niiskus
Parameeter Tingimuse Väärtus Ühikud
d
tüüp. 1,8 %RH
SHT40 RH täpsus 1 _
max. vaata -
Joonis 2
tüüp. 1,8 %RH
SHT41 RH täpsus 1
max. vaata -
Joonis 3
tüüp. 1,0 %RH
SHT45 RH täpsus 1
max. vaata -
Joonis 4
kõrge 0,08 %RH
Kordatavus 2 , 3 keskmine 0,15 %RH
madal 0,25 %RH
4. resolutsioon _ - 0,01 %RH
Hüsterees 25°C 0,8 %RH
juures
Määratud pikendatud 0 juurde 100 %RH
6
jooksis 5 _
Vastus aeg 7 t 63% 4 s
Pikaajaline triiv 8 tüüp. <0.2 %RH/a
Tabel 1: Kindral sugulane niiskus andur spetsifikatsioonid.
1 Sest määratlus kohta tüüp. ja max. täpsus, palun viidata juurde a dokument "Tundlikkus Niiskus Andur Spetsifikatsioon avaldus”.
2 The märgitud korratavus on 3 korda a standard hälve (3σ) kohta mitmekordne järjestikused mõõtmine väärtused juures konstantne tingimused ja on a mõõta
jaoks a müra füüsilise anduri väljundil. Erinevad korratavuse käsud on loetletud tabelis 7.
3 Kehtiv jaoks 25°C ja 50% suhteline õhuniiskus.
4 Resolutsioon kohta A/D muundur.
5 Määratud ulatus viitab juurde a ulatus jaoks mis a niiskus või temperatuuri andur spetsifikatsioon on garanteeritud.
6 Sest üksikasjad umbes soovitatav niiskus ja temperatuuri tegutsevad ulatus, palun viidata juurde osa 0.
www.sensirion.com / D1 Version 3 – April 2022 4/25
7 Aeg jaoks saavutamine 63% kohta a niiskus samm funktsioon, mõõdetud juures 25°C ja 1 m/s õhuvool. Niiskus vastuseks aega sisse a rakendus oleneb peal a disain
sisse kohta a andur.
8 Tüüpiline väärtus jaoks operatsiooni sisse normaalne RH/T tegutsevad ulatus. Väärtus võib olla kõrgemale sisse keskkondades koos aurustunud lahustid, gaasi
väljalaskmine lindid, liimid, pakendamine materjalid jne. Lisateavet leiate käsitsemisjuhistest.
www.sensirion.com / D1 Version 3 – April 2022 5/25
Sugulane Niiskus Täpsus
RH (%RH) RH (%RH)
±8 ±8
SHT40 typ SHT41 typ
±6 ±6
SHT40 max SHT41 max
±4 ±4
±2 ±2
±0 ±0
0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100
Sugulane Niiskus (%RH) Sugulane Niiskus (%RH)
Joonis 2: SHT40 tüüpiline ja maksimaalne Joonis 3: SHT41 tüüpiline ja maksimaalne
suhtelise niiskuse täpsus 25 °C juures. suhtelise niiskuse täpsus 25 °C juures.
RH (%RH)
±8
SHT45 typ
±6
SHT45 max
±4
±2
±0
0 10 20 30 40 50 60 70 80 90 100
Sugulane Niiskus (%RH)
Joonis 4: SHT45 tüüpiline ja maksimaalne sugulane niiskus täpsust juures 25 °C
Sugulane Niiskus Täpsus juures a Laiendatud Temperatuur Vahemik
The tüüpiline RH täpsust tolerantsid sisse a ulatus kohta T = 0°C … 80 °C on antud sisse Joonis 5 ,
Joonis
6 ja Joonis 7 .
SHT40 |typ. Delta %RH| SHT41 |typ. Delta %RH|
100 3 100
90 90 2
2
Relative Humidity (%RH)
Relative Humidity (%RH)
80 80
70 70
60 60
50 1.8 50 1.8
40 40
30 30
20 20
2
10 10 2
0 3 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
Temperature (°C) Temperature (°C)
Joonis 5: Tüüpiline RH täpsust sallivus Joonis 6: Tüüpiline RH täpsust sallivus liigne niiskus
liigniiskus ja temperatuur SHT40 jaoks. ja temperatuur SHT41 jaoks.
www.sensirion.com / D1 Version 3 – April 2022 6/25
SHT45 |tüüp. Delta %RH|
100 1.75
90
1.5
Sugulane Niiskus (%RH)
80
70
60
50
1
40
30
20
10 1.5
0
0 10 20 30 40 50 60 70 80
Temperatuur (°C)
Joonis 7: Tüüpiline RH täpsust sallivus läbi niiskus ja temperatuuri jaoks SHT45.
2.2 Temperatuur
Parameeter Tingimuse Väärtus Ühik
d ud
tüüp. 0,2 °C
SHT40 T Täpsus 1
max. vaata Joonis -
8
tüüp. 0,2 °C
SHT41 T Täpsus 1
max. vaata Joonis -
9
tüüp. 0,1 °C
SHT45 T Täpsus 1
max. vaata Joonis -
10
kõrge 0,04 °C
Korratavus 2 keskmine 0,07 °C
madal 0.1 °C
4. resolutsioon - 0,01 °C
Määratud - –40 juurde °C
vahemik 5 +125
Vastus aeg 9 t 63% 2 s
Pikaajaline triiv tüüp. <0,03 °C/a
10
Tabel 2: Kindral temperatuuri andur spetsifikatsioonid.
www.sensirion.com / D1 Version 3 – April 2022 7/25
9 Temperatuur vastuseks aega oleneb peal soojust juhtivus kohta andur substraat ja disain sisse kohta andur sisse rakendus.
10 Max väärtus on < 0,04 °C/a.
www.sensirion.com / D1 Version 3 – April 2022 8/25
Temperatuur Täpsus
T (°C) T (°C)
±1,0 ±1,0
SHT40 typ SHT41 typ
±0,8 ±0,8
SHT40 max SHT41 max
±0,6 ±0,6
±0,4 ±0,4
±0,2 ±0,2
±0,0 ±0,0
- 40 - 20 0 20 40 60 80 100 120 - 40 - 20 0 20 40 60 80 100 120
Temperatuur (°C) Temperatuur (°C)
Joonis 8: SHT40 tüüpiline ja maksimaalne Joonis 9: SHT41 tüüpiline ja maksimaalne
temperatuuri täpsus. temperatuuri täpsus.
T (°C)
±1,0
±0,8 SHT45 typ
SHT45 max
±0,6
±0,4
±0,2
±0,0
- 40 - 20 0 20 40 60 80 100 120
Temperatuur (°C)
Joonis 10: SHT45 tüüpiline ja maksimaalne temperatuuri
täpsust.
2.3 Soovitatav Töötavad Tingimused
The andur näitab parim esitus millal opereeritud sees a soovitatav normaalne temperatuur ja
niiskus ulatus kohta 5 °C … 60 °C ja 20 %RH … 80 %RH, vastavalt. Pikk tähtaeg kokkupuude
tingimustes, mis jäävad väljapoole soovitatud normaalset vahemikku, eriti kõrge suhtelise
õhuniiskuse korral, võib suhtelise õhuniiskuse signaali ajutiselt nihutada (nt +3 %RH 60 tunni
pärast > 80 %RH juures). Pärast soovitatud normaalse temperatuuri ja niiskuse vahemikku
naasmist taastub andur spetsifikatsioonide piires iseenesest. Pikaajaline kokkupuude
ekstreemsete tingimustega võib kiirendada vananemist.
Niiskusanduri stabiilse töö tagamiseks tuleb järgida dokumendis [2] kirjeldatud tingimusi
kokkupuude juurde muutlik orgaaniline ühendid peab olla kohtusime. Palun Märge nagu hästi et
see ei kehti mitte ainult transpordi ja tootmise, vaid ka SHT4x kasutamise kohta.
www.sensirion.com / D1 Version 3 – April 2022 9/25
3 Elektriline Tehnilised andmed
Kehtib kõigile elektrilistele spetsifikatsioonid: Tüüpiline väärtused vastavad V DD = 3,3 V ja T = 25
°C. Min. ja max. väärtused on kehtiv sisse a täis temperatuuri ulatus -40 °C … 125 °C ja juures
deklareeritud V DD tasemetel ja põhinevad iseloomustusel.
3.1 Elektriline Omadused
Parameeter Sümbol Tingimused Min Tüü Max Üksu Kommentaarid
p s
Toitepi
V DD 1.08 3.3 3.6 V -
nge
Toide V POR Staatiline võimsus
0.6 - 1.08 V -
üles/alla pakkumine
tasemel
Pingemuutused toite
Surnud
vahel V DD, min ja V DD,
määra V DD, - - 20 V/ms
tappis max. Kiiremad
toitepingest
pöördemäärad võib
_
juhtima juurde a
lähtestada
- 0,08 1.0 µA 25°C
Tühikäik olek juures
- - 3.4 Kell 125
°C
Toide sisse - 50 - µA -
Praegune samal ajal
Pakkumine Mõõtmine - 320 500 µA
I DD andur mõõdab _
vool (ilma Aver., kõrge korratavus - 2.2 -
küttekeha)
Aver. praegune tarbimist
Aver., med. korratavus - 1.2 - µA (pidev operatsiooni koos
üks mõõdud. per teine)
Aver., madal korratavus - 0.4 -
Aver., kõrge korratavus - 2.6 -
Energiatarve
Aver. energiatarve (pidev
. juures
- Aver., med. korratavus - 1.4 - µW operatsiooni ühe
VDD=1,2V
mõõduga. sekundis)
(nr
Keskm., madal - 0.5 -
kütteseade)
korratavus
Madala 0,3* -
V IL - 0 - V DD V
taseme
sisend Pinge
Kõrgetase 0,7* -
V IH - - V DD V
meline V DD
sisend Pinge
Tõmma V DD < 1.62 V 820 - - Ω -
Rp
ke V DD ≥ 1.62 V 390 - - Ω -
takistid
üles
V DD < 1,62 V, 0,2*
- - V -
R pullup > 820 Ω V DD
Madal V DD = 1,62 V … 2,0 V, 0,2*
V OL - - V -
väljund Pinge R pullup > 390 Ω V DD
V DD > 2,0 V,
- - 0.4 V -
R pullup > 390 Ω
Mahtuvuslik buss koormus
R P ≤ 820 Ω: kiire - - 400 pF saab alates
režiimis
www.sensirion.com / D1 Version 3 – April 2022 10/25
Mahtuvuslik C b < t tõusta /(0,8473*R p ).
Cb R p = 390 Ω,
siini Tõuse üles korda on t tõusta
VDD > 1.62 V: kiire - - 340 pF
koormus = 300 ns kiirrežiimi jaoks ja
režiimis pluss
t tõusta = 120 ns jaoks kiire
režiim pluss
Tabel 3: Elektriline spetsifikatsioonid.
www.sensirion.com / D1 Version 3 – April 2022 11/25
3.2 Ajad
Max väärtused on mõõdetud juures -40°C ja 1.08 V pakkumine Pinge (põhineb peal iseloomustus).
Parameeter Sümbol Tingimused Min. Tüü Max Ühik Kommentaarid
p. ud
DD vaheline aeg
Pärast raske jõudes V POR-i ja
Võimsus aega t PU - 0.3 1 Prl
lähtestada, andur sisenemine
V DD ≥ V POR jõudeolek _
Aeg pehme ACK-i vahel
lähtestada käsk ja andur
Pehme t SR Pärast pehme - - 1 Prl läheb jõudeolekusse.
lähtestada aeg lähtestada Kehtib ka I2C üldkõne
lähtestamiseks.
Madal Kaasa
t MÕÕDA,l - 1.3 1.6 Prl
korratavus arvatud t PU :
Mõõtmise kestus Med. Kolm korratavuse
t MEAS,m - 3.7 4.5 Prl
korratavus režiimi erinevad
Kõrge üksteisest juurde
t MÕÕDA,h - 6.9 8.3 Prl mõõtmise kestus, müra
korratavus
tasemel ja
energiatarbimist
Pärast et aega a
Pikk pulss 0.9 1 1.1 s küttekeha on
automaatselt välja
Kütteseade sisse t lülitatud
Kütteseade
lülitatud kestus
Pärast et aega a
Lühike pulss 0,09 0.1 0.11 s küttekeha on
automaatselt välja
lülitatud
Tabel 4 Süsteem ajastus spetsifikatsioonid.
3.3 Absoluutne Maksimaalne Hinnangud
Stress taset kaugemale loetletud tabelis 5 võib põhjustada püsivaid kahjustusi või mõjutada
seadme töökindlus. Need on ainult pingereitingud ja seadme funktsionaalne toimimine nendel
tingimustel ei ole garanteeritud. Hinnanguid testitakse ainult iga korraga.
Parameeter Hinnang
Max Pinge peal ükskõik milline pin V SS - 0.3 V … V DD + 0,3
V
Töötavad temperatuuri ulatus -40 °C … 125 °C
Säilitamine temperatuuri vahemik -40 °C …150 °C
11
ESD HBM 2 kV
ESD CDM 500 V
Riiv üles, JESD78 Klass II, 125 °C +-100 mA
Tabel 5: Absoluutne maksimaalselt hinnangud.
www.sensirion.com / D1 Version 3 – April 2022 12/25
11 The soovitatav ladustamine temperatuuri ulatus on 10-50°C. Palun konsulteerida a dokument "SHTxx Käitlemine Juhised” jaoks rohkem teavet.
www.sensirion.com / D1 Version 3 – April 2022 13/25
4 Andur Operatsioon
4.1 I2C suhtlemine
I2C suhtlemine on põhineb peal NXP-d I2C-buss spetsifikatsioon ja kasutaja manuaal UM10204,
Rev.6, 4 aprill 2014. aasta. Toetatud I2C režiimid on standard, kiire režiim, ja kiire režiimis pluss.
Andmed on kantakse üle 16-bitiste sõnade ja 8-bitise kontrollsumma kordsete kaupa (tsükliline
liiasuse kontroll = CRC). Kõik ülekanded peavad algama algustingimusega (S) ja lõppema
peatumise tingimusega (P). Lugemisedastuse lõpetamiseks saada mitte tunnistama (NACK) ja
peatus tingimus (P). Adresseerimine a spetsiifiline ori seade saadab selle 7-bitise I2C-aadressi,
millele järgneb kaheksas bitt, mis tähistab side suunda: "null" tähistab edastamist a ori, st
“kirjutada”, a "üks" tähistab a "loe" nõuda. I2C edastustüüpide skeemid on visandatud jaotises
Error! Viiteallikat ei leitud. . Andur ei toeta kella venitamist. Kui andur saab lugemispäise ja on
endiselt hõivatud nt mõõtmise või soojendamisega, tagastab see NACK. Mõõtmisandmeid saab
vastu võtta ainult üks kord ja kustutatakse jaotisest anduri register pärast esimene tunnustatud
I2C lugemispäis .
Joonis 11: I2C edastustüübid: Kõigepealt saadetakse I2C alamseadmele kirjutuspäis, millele järgneb
näiteks käsk "mõõta RH&T koos kõrgeim täpsus". Pärast a mõõtmine on lõpetanud a lugeda nõuda Sellele
I2C alam suunatakse kinnitus ja alamseade alustab andmete edastamist.
4.2 I2C Suhtlemine Ajastus
Kõik ajastamise üksikasjad järgivad liidese spetsifikatsioone NXP kasutusjuhendis UM10204,
Rev.6, 4. aprill 2014. Palun järgige tabelis toodud kohustuslikke nõudeid kondensaatoritele ja
takistitele . 3 .
4.3 Andmed tüüp & pikkus
I2C buss tegutseb koos 8-bitine andmeid paketid. Teave alates a andur juurde a meister on
kontrollsumma iga teise 8-bitise andmepaketi järel.
Niiskuse ja temperatuuri andmed edastatakse alati järgmisel viisil: Esimene väärtus on
temperatuuri signaal (2 * 8-bitine andmeid + 8-bitine CRC), a teiseks on a niiskus signaal (2 * 8-
bitised andmed
+ 8-bitine CRC).
4.4 Kontrollsumma Arvutus
Sest lugeda ülekandeid iga 16-bitine andmeid on järgnesid kõrval a kontrollsumma koos a järgnev
omadused
Kinnisvara Väärtus
Nimi CRC -8
Sõnum Pikkus 16- bitine
Polünoom 0x31 (x 8 + x 5 + x 4
+1)
Initsialiseerimine 0xFF
Peegelda Sisend vale/vale
väljund
Lõplik XOR 0x00
Näited CRC (0xBEEF) =
0x92
Tabel 6 Andmed kontrollsumma omadused.
www.sensirion.com / D1 Version 3 – April 2022 14/25
The meister võib katkestada a lugeda üleandmine pärast a 16-bitine andmeid kui seda teeb mitte
nõuda a kontrollsumma.
www.sensirion.com / D1 Version 3 – April 2022 15/25
4.5 Käsk Ülevaade
Käsk Vastus pikkus Kirjeldus
(kuuetei k.a. CRC (baiti) [tagasi
stkümn väärtused]
end)
0xFD 6 mõõta T & RH suure täpsusega (kõrge korratavus) [2 *
8-bitine T-andmed; 8-bitine CRC; 2 * 8-bitine RH-
andmed; 8-bitine CRC]
0xF6 6 mõõta T & RH koos keskmine täpsus (keskmine korratavus) [2 *
8-bitised T-andmed; 8-bitine CRC; 2 * 8-bitised RH-andmed;
8-bitine CRC]
0xE0 6 mõõta T & RH koos madalaim täpsus (madal korratavus)
[2 * 8-bitine T-andmed; 8-bitine CRC; 2 * 8-bitine RH-
andmed; 8-bitine CRC]
0x89 6 lugeda sari number
[2 * 8-bitine andmed; 8-bitine CRC; 2 * 8-bitine andmed; 8-
bitine CRC]
pehme
0x94 -
lähtesta
[ACK]
aktiveerida küttekeha koos 200mW jaoks 1s, kaasa arvatud a
0x39 6 kõrge täpsusmõõtmine vahetult enne deaktiveerimist
[2 * 8-bitine T-andmed; 8-bitine CRC; 2 * 8-bitine RH-andmed;
8-bitine CRC]
aktiveerida küttekeha koos 200mW jaoks 0,1 s kaasa arvatud
0x32 6 a kõrge täpsusmõõtmine vahetult enne deaktiveerimist
[2 * 8-bitine T-andmed; 8-bitine CRC; 2 * 8-bitine RH-andmed;
8-bitine CRC]
aktiveerida küttekeha koos 110mW jaoks 1s kaasa arvatud a
0x2F 6 kõrge täpsusmõõtmine vahetult enne deaktiveerimist
[2 * 8-bitine T-andmed; 8-bitine CRC; 2 * 8-bitine RH-andmed;
8-bitine CRC]
aktiveerida küttekeha koos 110mW jaoks 0,1 s kaasa arvatud
0x24 6 a kõrge täpsusmõõtmine vahetult enne deaktiveerimist
[2 * 8-bitine T-andmed; 8-bitine CRC; 2 * 8-bitine RH-andmed;
8-bitine CRC]
aktiveerida küttekeha koos 20mW jaoks 1s kaasa arvatud a
0x1E 6 kõrge täpsusmõõtmine vahetult enne deaktiveerimist
[2 * 8-bitine T-andmed; 8-bitine CRC; 2 * 8-bitine RH-andmed;
8-bitine CRC]
aktiveerida küttekeha koos 20mW jaoks 0,1 s kaasa arvatud a
0x15 6 kõrge täpsusmõõtmine vahetult enne deaktiveerimist
[2 * 8-bitine T-andmed; 8-bitine CRC; 2 * 8-bitine RH-andmed;
8-bitine CRC]
Tabel 7 Ülevaade kohta I2C käske. Kui a andur on mitte valmis juurde protsessi a käsk, nt sest seda on
endiselt mõõtes, vastab see I2C lugemispäisele NACK-iga. Antud küttekeha võimsuse väärtused on
tüüpilised ja kehtivad VDD = 3,3 V korral.
4.6 Teisendamine kohta Signaal Väljund
The digitaalne andur signaale vastama juurde järgnev niiskus ja temperatuuri väärtused:
𝑆 𝑅𝐻
𝑅𝐻 = (−6 + 125 ∙ 16–1 ) RH 2 (1)
𝑆𝑇
𝑇 = (−45 + 175 ∙ ) (2)
° C 2 16–1
𝑆𝑇
𝑇 = (−49 + 315 ∙ ) °F (3)
2 −1
16
www.sensirion.com / D1 Version 3 – April 2022 16/25
NB! RH teisendusvalem (1) võimaldab esitada väärtused, mis jäävad vahemikku 0 %RH … 100
%RH. Suhtelise niiskuse väärtused, mis on väiksemad kui 0 %RH ja suuremad kui 100 %RH on
siiski mittefüüsilised need "kärpimata" väärtused võivad olla leiti kasulikuks mõnel juhul (nt kui
huvi pakub andurite jaotus mõõtmispiiridel). Kõigile kasutajatele, kes ei soovi tegeleda nende
mittefüüsiliste väärtuste hindamisega, on soovitatav RH signaali kärpida vahemikku 0 %RH …
100 %RH.
www.sensirion.com / D1 Version 3 – April 2022 17/25
4.7 Seerianumber _
Igal anduril on kordumatu seerianumber, mille Sensirion määrab tootmise ajal. See on
salvestatud ühekordselt programmeeritavasse mällu ja seda ei saa pärast tootmist
manipuleerida. Seerianumbrile pääseb juurde I2C käsu 0x89 kaudu ja see edastatakse kahe 16-
bitise sõnana, millest igaühele järgneb 8-bitine CRC.
4.8 Lähtesta & Katkesta
A lähtestada kohta a andur saab olla saavutatud sisse kolm viisid:
• Pehme lähtestamine: saada a lähtestada käsk kirjeldatud sisse Tabel 7 .
• I2C üldkõne lähtestamine: kõik I2C siinil olevad seadmed lähtestatakse, saates I2C-
aadressile 0x00 käsu 0x06.
• Võimsus alla (sh. tõmmates SCL ja SDA madal)
Ükskõik milline käsk et käivitajad an tegevust juures a andur saab olla katkestatud kaudu I2C üldine
helistama lähtestada või pehme lähtestamine.
4.9 Kütteseade Operatsioon
Andur sisaldab integreeritud pakendis olev küttekeha, mida saab sisse lülitada käskude komplekt
antud sisse Tabel 7 . Kolm küte volitused ja kaks küte kestused on valitav. Pärast kütteseadme
sisselülitamise käsu vastuvõtmist teostab andur järgmise protseduuri:
1. The küttekeha on lubatud, ja a taimer algab selle tagasilugemine .
2. Peal taimer aegumist a temperatuuri ja niiskus mõõtmine koos a kõrgeim korratavus
käivitub, jääb kütteseade sisse lülitatuks.
3. Pärast a mõõtmine on lõpetanud a küttekeha on välja lülitatud .
4. Temperatuur ja niiskus väärtused on nüüd saadaval jaoks Loe ette.
Maksimaalne õigel ajal küttekeha käske on 1 teiseks korras juurde vältige anduri ülekuumenemist
kütteseadme tahtmatul kasutamisel. Seega pole kütteseadme väljalülitamiseks spetsiaalset
käsku. Sest pikendatud küte perioodid seda on nõutud juurde saada perioodiline küttekeha sisse
lülitatud käsud, pidades meeles, et kütteseade on konstrueeritud maksimaalseks töötsükliks alla
10%. Temperatuuri kiire tõusu saavutamiseks peab järjestikuste kütteimpulsside vaheline
tühikäiguaeg olema minimaalne.
Võimalik Kütteseade Kasutage Juhtumid
Seal tahe olla pühendatud Sensiirion rakendus märkmeid väljatöötamine peal
mitmesugused kasutada juhtudel kohta küttekeha. Üldiselt on pakendil asuvate
küttekehade rakendused järgmised:
1. Eemaldus kohta tihendatud / pihustada vesi peal a andur pinnale. Kuigi kondenseeritud
vesi ei ole anduri töökindluse/kvaliteediprobleem, kuid see ei reageeri andurile õhu
suhtelise niiskuse muutustele seni, kuni pinnal on vedelat vett.
2. Roomamisvaba operatsiooni sisse kõrge niiske keskkondades. Perioodiline küte
kaunviljad lubama jaoks libisemisvabad kõrge õhuniiskuse mõõtmised pikka aega.
Tähtis märkmeid jaoks tegutsevad a kütteseade:
1. The küttekeha on disainitud jaoks a maksimaalselt kohustus tsükkel kohta 10%
tähenduses a kokku küttekeha sisselülitusaeg ei tohiks olla pikem kui 10% anduri tööeast.
2. ajal operatsiooni kohta a kütteseade, andur spetsifikatsioonid on mitte kehtiv.
3. Temperatuuriandurit võib lisaks mõjutada termiliselt indutseeritud mehaaniline pinge, mis
kompenseerib temperatuuri näidu tegelikust temperatuurist.
4. The anduri omad temperatuuri (alus temperatuuri + temperatuuri suurendama alates
kütteseade) peab ei tohi ületada T max = 125 °C, et kiibil oleks õige elektriline
funktsionaalsus.
5. Keris võtab pärast sisselülitamist suurel hulgal voolu (kõrgeima võimsusega kuni ~75mA).
seadistus). Kuigi a pühendatud vooluringid tõmbab see praegune sujuvalt, a võimsus toide
peab olema piisavalt tugev, et vältida suuri pingelangusi, mis võivad põhjustada anduri
www.sensirion.com / D1 Version 3 – April 2022 18/25
lähtestamist.
www.sensirion.com / D1 Version 3 – April 2022 19/25
6. Kui kõrgemale küte temperatuurid on soovitakse, järjestikused küte käske on juurde olla
saadetakse a andur. The küttekeha peab ainult olla opereeritud ümbritsevas keskkonnas
temperatuurid allapoole 65°C vastasel juhul võib see anduri juhtida väljaspool selle
maksimaalset töötemperatuuri.
5 Füüsiline Spetsifikatsioon
5.1 pakett Kirjeldus
SHT4x on ette nähtud sisse an avatud õõnsus kahekordne tasane ei juhtima (DFN) pakett. The
niiskus andur avamine on tsentreeritud peal a üleval pool kohta a pakett. The andur kiip on tehtud
kohta räni, majutatud peal a vasest pliiraam ja üle valatud epoksiidipõhise vormiseguga.
Juhtraami paljastatud alumine pool koos metallkontaktidega on kaetud Ni/Pd/Au, külgseinad on
vasest.
Niiskustundlikkuse tase (MSL) on 1 vastavalt IPC/JEDEC J-STD-020-le. Soovitatav on andureid
töödelda ühe aasta jooksul pärast tarnekuupäeva.
5.2 pakett Kontuur
Joonis 12 Mõõtmeline joonistamine kohta SHT4x kaasa arvatud pakett tolerantsid (ühikut mm).
5.3 Maa muster
The maa muster on soovitatav juurde olla disainitud vastavalt juurde a kasutatud PCB ja jootmine
protsessi koos koos a füüsiline välimine mõõtmed kohta a andur. Sest viide, a maa muster
kasutatud Sensirioni PCB-de ja jootmisprotsessidega on toodud joonisel 13 .
Jootmine kohta a keskne surema pad on valikuline. Sensiirion soovitab juurde mitte jootma a
keskne surema padi, sest andur võib kütteseadme aktiveerimisel tõusta kõrgemale
temperatuurile.
www.sensirion.com / D1 Version 3 – April 2022 20/25
Joonis 13: Soovitatav maa muster (in
mm). Üksikasjad saab varieeruda ja
sõltuvad kasutatud PCBd ja jootma
protsessid. Anduri all ei tohi olla vaske
muud kui juures a pin
padjad.
5.4 Pin Ülesandmine & Lasermärgistus _
Pin Nimi Kommentaarid
1 SDA Sari andmed, kahesuunaline
2 SCL Sari kell, ühesuunaline sisend
3 VDD Pakkumine Pinge
4 VSS Maapin
d
Joonis 14 Tihvtide määramine (läbipaistev pealtvaade). Katkendjooned on nähtavad ainult siis, kui
andurit vaadata altpoolt. Matriitsipadi ei ole otseselt ühegi tihvtiga ühendatud.
The laser märgistamine koosneb kohta kaks read, näidatud sisse Joonis 14 . sisse a esiteks rida
a täidetud ring toimib pin-1 indikaatorina ja sellele järgneb "SH4". Viimane märk näitab selle
täpsusklassi toode (siin "x" teenindab nagu koht hoidja). sisse a teiseks rida, a esiteks kolm
tegelased täpsustada toode omadused vastavalt juurde positsioonid 7, 8 ja 9 kohta Tabel 9
. The teiseks kolm
tegelased teenima nagu sisemine partii jälgimine kood.
www.sensirion.com / D1 Version 3 – April 2022 21/25
5.5 Soojus Teave
Kütteseade Kütteseade
Kütteseade Kütteseade
väljas, peal,
Sümbol Kirjeldus väljas, peal,
stantsipadi _ stantsipadi _
stantspadi stantspadi
mitte mitte
joodetud joodetud
joodetud joodetud
(K/W) (K/W) (K/W) (K/W)
Ühenduse ja
𝑅 𝜃𝐽𝐴 246 308 297 357
ümbritseva
keskkonna
soojustakistus
Termoühendus
𝑅 𝜃𝐽𝐶 189 255 191 257
ümbrisega
vastupanu
Junction-to-board
𝑅 𝜃𝐽𝐵 159 225 193 258
termiline vastupanu
Junction-to-board
Ψ 𝐽𝐵 iseloomustuse 159 223 191 254
param.
Junction-to-top
Ψ 𝐽𝑇 iseloomustuse 38 105 44 112
param.
Tabel 8 Termilise mõõdiku tüüpilised väärtused. Veergudes “kütteseade sees” eeldati küttekeha
võimsuseks 200 mW. Jootmine kohta a surema pad on mitte soovitatav, seetõttu a kaks õige käsi pool
veerud on julge. Väärtused põhinevad simulatsioonil.
6 Kvaliteet ja Materjal Sisu
SHT4x kvalifitseerimine toimub JEDEC JESD47 kvalifikatsioonikatse meetodi alusel,
kvalifitseerimisaruanne on saadaval nõudmisel. Seade on täielikult RoHS-i ja WEEE-ühilduv, nt
Pb-, Cd- ja Hg-vaba.
Üldised märkused niiskusanduri töötlemise parimate tavade kohta leiate käsitsemisjuhistest [2].
7 Lint ja Rull Pakendamine
Kõik lindi ja rulli pakendi spetsifikatsioonid leiate jooniselt 15 . Rulli läbimõõt on vastavalt 13 tolli
ja 8 tolli 10k ja 2,5k pakendisuuruste puhul.
Joonis 15: Lint ja rull spetsifikatsioonid kaasa arvatud anduri orientatsioon sisse tasku (vaata näidustus
kohta kaks andurid lindi paremal küljel).
www.sensirion.com / D1 Version 3 – April 2022 22/25
8 Toode Nimi Nomenklatuur
positsio väärtus selgitus
oni ed)
1 S Sensiirion
2 H Niiskus Signaal
3 T Temperatuur Signaal
4 4 Neljandaks toode põlvkond
0 Alus täpsust
5 1 Keskmine täpsust
5 Parim täpsust
6 - piiritleja
A I2C liides koos 0x44 aadress I2C
7
B liides koos 0x45 aadress
8 D DFN pakett
9 1 reserveeritud
B pakett ilma membraan
10 F pakett koos integreeritud, patenteeritud PTFE
membraan
P pakett koos integreeritud, eemaldatav kaitse kork
11 - piiritleja
12 R Lint peal rull pakendamine
2 Pakendamine artiklit sisaldab 2'500 tükid
13
3 Pakendamine artiklit sisaldab 10 000 tükid
Tabel 9 SHT4x toode nimi nomenklatuur.
9 Tellimine Teave
Materjal Kirjeldus Materjal Number Üksikasjad Kogus (tk)
SHT40-AD1B- R2 3 000 465 alus RH&T acc., 0x44 I2C adr. 2'500
SHT40-AD1B- R3 3 000 353 alus RH&T acc., 0x44 I2C adr. 10 000
baas RH&T acc., 0x44 I2C adr., sh
SHT40-AD1F- R3 tbd patenteeritud PTFE membraan 10 000
saadaval Q3/22
alus RH&T acc., 0x44 I2C adr.,
SHT40-AD1P- R3 tbd saadaval eemaldatav kaitsekork 10 000
Q3/22
SHT40-BD1B- R2 3 000 492 alus RH&T acc., 0x45 I2C adr. 2'500
SHT40-BD1B- R3 3 000 610 alus RH&T acc., 0x45 I2C adr. 10 000
SHT41-AD1B- R2 3 000 466 intermed. RH&T acc., 0x44 I2C adr. 2'500
SHT41-AD1B- R3 3 000 611 intermed. RH&T acc., 0x44 I2C adr. 10 000
SHT45-AD1B- R2 3 000 645 ±1,0 %RH, ±0,1 °C acc., 0x44 I2C adr. 2'500
SHT45-AD1B- R3 3 000 750 ±1,0 %RH, ±0,1 °C acc., 0x44 I2C adr. 10 000
Tabel 10 SHT4x tellimine valikuid.
www.sensirion.com / D1 Version 3 – April 2022 23/25
10 Bibliograafia
[1] K. Ehrhorn, "A Niiskus Andur ja a meetod jaoks Tootmine a Sama." Ühendkuningriik, DE, FR, NL, DM, OLE,
USA, CN patent EP1810013, US7741950, CN101040181, 2005.
[2] Sensior, "Käitlemine Juhised jaoks Niiskus Andurid," 2020.
11 Läbivaatamine Ajalugu
Kuupäev Versioo Lehekül Muudatused
n g(ed)
oktoober 1 kõik Esialgne vabastada
2020
juulil 2021. 2 mitu 3 Kaasas kirjavea
aasta 4 parandus kontrollsumma sisse
4 Joonis 1
10 Kaasas kirjeldus kohta NIST jälgitavus sisse osa 2
9 Tabelis 1 on toodud korratavuse selgitus
12 Täpsustatud I2C-suhtlus jaotises 4.1 Eemaldatud
15 ooteaja spetsifikatsioon tabelis 4 Määratud
11 seerianumber punktis 4.7
12 Uuendatud kvalifikatsiooni olek jaotises 6
12 Kustutatud binaarne com. & kaasatud tagasi väärtused
16 sisse Tabel 7
Uuendatud märkus küttekeha töötsükli kohta jaotises
4.9 Lisatud Märge peal suur praegune joonistatud kõrval
küttekeha sisse osa 4.9
Uuendatud tellimine teavet sisse Tabel 10
aprill 2022. 3 mitu Kaasas SHT45 RH- ja T-täpsus tehnilised andmed
aasta korda 4 Laiendatud max. küttekeha töötsükkel kuni 10%
4 Tabelis 1 vähendati suhtelise niiskuse
4 reaktsiooniaega 4 sekundini Tabelis 1 vähendati
9 pikaajalist triivi kuni <0,2 % suhtelise õhuniiskuse
10 aastas Vähendatud hüsterees juurde ±0,8%
16 suhteline niiskus juures 25°C sisse Tabel 1
16 Värskendatud max mõõtmisajad tabelis 4
Kaasatud I2C side ajastus jaotises 4.2 Tabelis 9
tutvustatud toote uut versiooni
Uuendatud tellimine teavet sisse Tabel 10
www.sensirion.com / D1 Version 3 – April 2022 24/25
Tähtis Märkused
Hoiatus, Isiklik Vigastus
Ärge kasutage seda toodet ohutuse tagamiseks või hädaseiskamisseadmetes või mis tahes muus rakenduses, kus rike toote
kasutamine võib põhjustada isiklik vigastus. Tee mitte kasutada see toode jaoks rakendusi muud kui selle mõeldud ja volitatud
kasutada. Enne paigaldamine, selle toote käsitsemisel, kasutamisel või hooldamisel lugege palun andmelehte ja rakenduse
märkusi. Nende juhiste eiramine võib põhjustada surma või tõsiseid vigastusi.
Kui a Ostja ostab või kasutada SENSIRION tooteid soovimatute jaoks või volitamata rakendus, Ostja kaitseb, hüvitama ja kahjutuks
tegema SENSIRION'i ja selle ametnikke, töötajaid, tütarettevõtteid, sidusettevõtteid ja turustajaid kõigi nõuete, kulude, kahjude ja kulude
ning mõistlike advokaaditasude eest, mis tulenevad otseselt või kaudselt sellistest soovimatutest kehavigastustest või surmast. või
volitamata kasutada, isegi kui SENSIRION peab olla väidetavalt hooletu koos lugupidamine juurde a disain või a tootmine kohta a toode.
ESD ettevaatusabinõud
Selle komponendi omapärane disain muudab selle tundlikuks elektrostaatilise laengu (ESD) suhtes. ESD-st põhjustatud kahjustuste ja/või
lagunemise vältimiseks võta tavapärane ja kohustuslik ESD ettevaatusabinõud, millal käitlemine see toode. Vaata rakendus Märge "ESD,
Latchup ja EMC” lisateabe saamiseks teavet.
Garantii
SENSIRION annab garantii ainult selle toote algsele ostjale 12 kuu (üks aasta) jooksul alates tarnekuupäev, et selle toote kvaliteet,
materjal ja töötlus on määratletud SENSIRIONi avaldatud toote spetsifikatsioonides. Selle aja jooksul, kui tõestatud juurde olla defektne,
SENSIRION peab remont ja/või asendada see toode, sisse SENSIRION oma diskreetsus, tasuta kohta tasu juurde a Ostja, tingimusel et:
• märkama sisse kirjutamine kirjeldades a defektid peab olla antud juurde SENSIRION sees neliteist (14) päevadel pärast nende välimus;
• SENSIRION'i piisava rahulolu kohaselt leitakse, et sellised defektid on tekkinud SENSIRIONi vigasest disainist, materjalist, või
töötlus;
• a defektne toode peab olla tagasi juurde SENSIRION oma tehas juures a Ostja oma kulu; ja
• a garantii periood iga parandatud või asendatud toode peab olla piiratud juurde a aegumata osa kohta a originaal periood.
See garantii teeb mitte kohaldada juurde ükskõik milline varustus mis on mitte olnud paigaldatud ja kasutatud sees a spetsifikatsioonid
soovitatav kõrval SENSIRION seadme sihipärase ja õige kasutamise eest. VÄLJA ARVATUD SIIN SELGELT ESITATUD GARANTIID,
ANNA SENSIRION TOOTELE EI OTSESELGESTI EGA KAUDSE GARANTIID. KÕIK JA KÕIK GARANTIID, SEALHULGAS
PIIRANGUDEGA KAUBANDUSLIKU VÕI KONKREETSEKS EESMÄRGIKS SOBIVUSE GARANTIID, ON SELGESELGSELT
VÄLISTATUD JA KEHASTATUD.
SENSIRION vastutab ainult selle toote defektide eest, mis on tekkinud andmelehel sätestatud töötingimustel ja toote nõuetekohasel
kasutamisel. a kaubad. SENSIRION selgesõnaliselt loobub kõik garantiid, väljendada või kaudne, jaoks ükskõik milline periood ajal mis a
kaubad on opereeritud või ladustatud mitte kooskõlas tehniliste kirjeldustega.
SENSIRION teeb mitte oletada ükskõik milline vastutust tekkiv välja kohta ükskõik milline rakendus või kasutada kohta ükskõik milline toode
või vooluring ja konkreetselt loobub ükskõik milline ja kogu vastutus, kaasa arvatud ilma piirang tagajärg või juhuslik kahjud. Kõik tegutsevad
parameetrid, kaasa arvatud ilma piirang soovitatavad parameetrid, peavad kliendi tehnilised eksperdid iga kliendi rakenduste jaoks
valideerima. Soovitatavad parameetrid võivad erinevates rakendustes erineda ja erinevad.
SENSIRION reservid a õige, ilma edasi märkama, (i) juurde muuta a toode spetsifikatsioonid ja/või a teavet sisse see dokument ja (ii)
parandada selle toote töökindlust, funktsioone ja disaini.
Autoriõigus © 2022, kõrval SENSIRION. CMOSens ® on a kaubamärk kohta Sensiirion. Kõik õigusi reserveeritud
Peakorter ja Tütarettevõtted
Sensirion AG Sensiirion Inc. USA Sensirion Korea Co. Ltd.
Laubisruetistr. 50 telefon: +1 312 690 5858 telefon: +82 31 337 7700~3
CH-8712 Staefa ZH
[email protected] [email protected]
Šveits www.sensirion.com www.sensirion.com/kr
telefon: +41 44 306 40 00 Sensiirion Jaapan Co. Sensiirion Hiina Co. Ltd.
faks: +41 44 306 40 30 Ltd. telefon: +86 755 8252 1501
[email protected] telefon: +81 3 3444 4940
[email protected]
www.sensirion.com
[email protected] www.sensirion.com/cn
www.sensirion.com/jp
Sensiirion Taiwan Co. Ltd
telefon: +886 3 5506701
[email protected]
www.sensirion.com
Kellele leida sinu kohalik esindaja, palun külastada www.sensirion.com/distributors
www.sensirion.com / D1 Version 3 – April 2022 25/25
MAKSEKORRALDUS NR 52
MAKSJA / REMITTER / ПЛАТЕЛЬЩИК KUUPÄEV / DATE / ЧИСЛО
NETBITS OÜ
27.07.2023
MAKSJA KONTO NR / REMITTER´S ACC. / № СЧЕТА ПЛАТЕЛЬЩИКА REG. NR / REG. NO / РЕГ. № SELGITUS / DETAILS OF PAYMENT / ОБъЯСНЕНИЕ ПЛАТЕЖА
riigilõiv
EE702200221079098411 16498137 (Registreerimisnumber)
MAKSJA PANK / REMITTER´S BANK / БАНК ПЛАТЕЛЬЩИКА
Swedbank AS
SAAJA / BENEFICIARY / ПОЛУЧАТЕЛЬ
RAHANDUSMINISTEERIUM
SAAJA KONTO NR / BENEFICIARY´S ACC. / № СЧЕТА ПОЛУЧАТЕЛЯ VIITENUMBER / REFERENCE NO / НОМЕР ССЫЛКИ
EE932200221023778606 2900082126
SAAJA PANK / BENEFICIARY´S BANK / БАНК ПОЛУЧАТЕЛЯ SUMMA / AMOUNT IN FIGURES / СУММА TEENUSTASU / CHARGES / ТАРИФ
Swedbank AS 640.00 EUR 0.16
SUMMA SÕNADEGA / AMOUNT IN WORDS / СУММАПРОПИСЬЮ
Kuussada nelikümmend eurot 00 senti
MAKSJA EES-JA PEREKONNANIMED, ALLKIRJAD / PITSER PANGA MÄRGE/ BANK`S NOTE/ ПОМЕТКA БAНКА
REMITTER’S NAMES AND SURNAMES, SIGNATURES / STAMP / ИМЕНА И ФАМИЛИИ, ПОДПИСИ / ПЕЧАТЬ ПЛАТЕЛЬЩИКА
2023072701051165
KÄESOLEVA MAKSEKORRALDUSE ALLKIRJASTAMISEGA KINNITAN, ET OLEN TUTVUNUD JA NÕUSTUN SWEDBANK AS KEHTIVA HINNAKIRJA JA MAKSETEHINGUTE TEOSTAMISE TINGIMUSTEGA.
ПОДПИСАНИЕМ НАСТОЯЩЕГО ПЛАТЕЖНОГО ПОРУЧЕНИЯ ПОДТВЕРЖДАЮ, ЧТО Я ОЗНАКОМИЛСЯ/ОЗНАКОМИЛАСЬ И СОГЛАСЕН/СОГЛАСНА С ДЕЙСТВУЮЩИМИ В SWEDBANK AS ПРЕЙСКУРАНТОМ И УСЛОВИЯМИ ОСУЩЕСТВЛЕНИЯ ПЛАТЕЖНЫХ ОПЕРАЦИЙ.
BY SIGNING THIS PAYMENT ORDER I WARRANT AND REPRESENT THAT I HAVE EXAMINED AND CONSENT TO THE EFFECTIVE PRICE LIST AND CONDITIONS FOR MAKING PAYMENT TRANSACTIONS OF SWEDBANK AS.
Ühispakkumuse volikiri
28. juunil 2023.a
Hankija: Eesti Kunstiakadeemia
Hanke nimetus: Ruumikasutuse ja sisekliima monitooringu süsteem energiatarbimise optimeerimiseks
Käesolevaga volitab Proekspert AS (registrikood 10331577, aadress Sõpruse pst 157, 13417 Tallinn)
juhatuse liikme Ilmar Pralla isikus ettevõtet Netbits OÜ (registrikood 16498137, aadress Sõpruse pst 157,
13417 Tallinn) esitama Proekspert AS nimel eelnimetatud riigihankes ühispakkumust ning teostama
hankemenetluse ning hankelepingu sõlmimise ja täitmisega seotud toiminguid.
Volikiri on antud ilma edasivolitamise õiguseta.
Ilmar Pralla
juhatuse liige
Proekspert AS
/ allkirjastatud digitaalselt /
AS Proekspert Tel +372 651 8700 Reg nr 10331577
[email protected]
Sõpruse pst 157, 13417 Tallinn Faks +372 651 8701 KMKR nr EE100185388 proekspert.ee