dokumendiregister.ee
OtsingAsutusedMCP
Otsing›Konkurentsiamet
Väljaminev kiriAvalik

Aruanne

Konkurentsiamet · 15. november 2019
Viit
4-17/2019-074-2
Registreeritud
15. november 2019
Dokumendi liik
Väljaminev kiri
Adressaat
The Council of European Energy Regulators (CEER)
Saabumis/saatmisviis
käsipost
Funktsioon
4 Rahvusvaheline koostöö
Sari
4-17 ACER (CEER) regulaatoritega ja Euroopa Komisjoniga seotud kirjavahetus
Toimik
4-17/2019
Vastutaja
Egert Luukas (Konkurentsiamet, Regulatsiooniteenistus, Energeetika- ja postiosakond)

Failid

  • 📎regulatory-practices-on-volume-mismatch-input-output-in-the-distribution-network-761118-queXML.pdf4322 KB

Sisu (failidest)

Section A: 1.Information about load profiles for non-daily metered customers according to Art. 42 par. 2 BAL NC A1. 1.1 Briefly describe how the load profiling works, including: a) What are input data to the load profiling b) How and how often they are updated c) What is the share (in term of volumes) of final customers with load- profiling. The system operator creates a digital environment (hereinafter, ‘data exchange platform’), and makes it possible, on an equal footing, for market participants who have the corresponding statutory duty and the corresponding statutory right to submit and to receive data. The submission and receiving of data is free of charge. Data exchange platform have module for forecasting network user’s non-daily metered off- takes. In Estonia the forecasting party is TSO (designated by NRA). Forecasting uses historical data in data exchange platform. The share (in term of volumes) of final customers with load-profiling is estimated 12%. Section B: 2. Settlement of Δin-out B1. 2.1 Please describe where does the Δin-out regulation originate from (Primary legislation, such as law, Ministry decrees, etc…, secondary legislation, such as NRAs resolutions, TSOs network code approved by NRAs, or none of the above Narural Gas Act (https://www.riigiteataja.ee/en/eli/520032019006/consolide#para12 ) – law. B2. 2.2 How is Δin-out determined (possibly add to the description a formula and the legenda)? The network operator shall determine the gas volume data for the balancing period according to its network metering points as follows: 1) when using a remote reading device - according to measurement data; 2) when using a reading device - on the principle that the sum of the gas volumes of the metering points during the balance period is the amount of gas entered into the network during the balance period minus the sum of the gas volumes of remote reading devices in the same balance period; 3) the volume of the measuring point equipped with a reading device shall be calculated during the balance period by multiplying the total amount of gas at a given measuring point during accounting period the proportion of the total volume of gas at the measuring points equipped with a reading device during the balancing period. The proportion of the total volume of gas at the measuring points equipped with a reading device during the balancing period is a proportion of the total volume of gas at the measuring points equipped with a reading device during the accounting period. B3. 2.3 How is Δin-out settled/balanced and which market roles are involved? Δin-out is settled/balanced by balance provider. The balance provider enters into gas supply contracts on terms which make it possible for that provider to ensure its balance at any time. B4. 2.4 Who bears the correspondent costs? Every market participant has to bear its correspondent costs. For example DSO has to bear correspondent costs, which are necessary for purchasing the gas used to provide network services (DSO concludes the contract with balance provider, who keeps DSO’s balance of gas). DSO can put the correspondent cost into network tariff (NRA accepted them in tariff approval process as any necessary cost). B5. 2.5 Referring to Chapter 3 and Figure 5 of the core document, indicate which Option (Option 1 or Option 2) is in place in your country to calculate the offtakes in the imbalance formula of the network user? If none of the options correctly describes the situation in your country, please describe how it works. DSO’s gas useage is treated as any network user’s gas useage. B6. 2.6 How do you assess your current method in terms of implication for the gas market and for the final customers? OK Section C: 3. Information about observed Δin-out: C1. 3.1 Provide the information of Δin-out observed in distribution networks (ideally national value or at least some samples of specific networks): the amount (observed values) of Δin-out, possibly in different time intervals (day, month, year, multiple years… In tariff process we accept three years average Δin-out. Most of them are positive, but we have one DSO with negative result (reduce tariff). C2. possible idea of components (losses, load profiling…) We do not have assessed components, but we have idea that biggest component is commercial component (customers inform DSO on meters reading monthly) and second is that domestic users do not have volume converters metering devices. C3. if there is in your country a range of Δin-out (overall or single components thereof) that is assumed to be “normal” in gas operation? In Estonia we don’t have a range of Δin-out that is assumed to be “normal” in gas operation. In tariff process we accept three years average Δin-out, which is based on network operator’s actual data. C4. 3.2 Does Δin-out present substantial differences (% of IN) between different distribution networks? If yes, please describe the differences in the characteristics of the distribution networks or other factors that may cause those differences Examples: 1 - City networks vs rural networks 2 - Interconnected networks TSO/DSO or other type of DSO networks (isolated). Yes, Δin-out presents substantial differences between different distribution networks. The differences are bigger in distribution networks, where most of gas is consumpted by domestic users (domestic users do not have volume converters metering devices) and it is smaller in distribution networks, where most of gas is consumpted by not domestic users (commercial companies, who have volume converters metering devices). Section D: 4. D1. Which regulatory instruments are in place or planned in your country to reduce the amount of Δin-out and on which concepts and trade- offs these instruments are based (refer to chapter 3 in the core document) No regulatory instruments because Δin-out is normal cost component. DSO must show of real cost appearance to NRA. Section E: 5. Information about existing incentive scheme for DSOs E1. 5.1 Is DSO incentivised to reduce losses or Δin-out in general? If yes, describe the incentive No E2. 5.2 Are there other incentives to DSOs in place? No E3. 5.3 Provide general information about meter update/upgrade plans (incl. potential smart meter roll-out plans) The network operator shall ensure that all metering points consuming at least 750 cubic meters of gas per annum from the network of the network operator shall be equipped with a metering system which takes into account the temperature of the gas in the metering system and enables remote reading of metering data.[Entry into force 01.01.2020]. The DSO shall ensure that the gas metering data of the measuring points (mentioned above) is transmitted to the TSO (data exchange platform) by remote reading from 01.01.2021. Thank you for your answers! Powered by TCPDF (www.tcpdf.org)
Allikas: Konkurentsiamet dokumendiregister →
dokumendiregister.eeAsutusedEesti avalike dokumendiregistrite otsing · nimistu.ee andmetel