Väljaminev kiriAvalik
Väljaminev kiri
Konkurentsiamet · 1. aprill 2019
- Viit
- 4-16/2019-025-2
- Registreeritud
- 1. aprill 2019
- Dokumendi liik
- Väljaminev kiri
- Saabumis/saatmisviis
- käsipost
- Funktsioon
- 4 Rahvusvaheline koostöö
- Sari
- 4-16 Energeetikavaldkonna väliskirjavahetus
- Toimik
- 4-16/2019
- Vastutaja
- Tiina Maldre (Konkurentsiamet, Regulatsiooniteenistus, Energeetika- ja postiosakond)
Sisu (failidest)
Saatja: Tiina Maldre </o=JM/ou=Exchange Administrative Group (FYDIBOHF23SPDLT)/cn=Recipients/cn=6cc804a2a4344e75b160b38f1d7c2351-Tiina Maldre>
Saaja: '[email protected]'
Teema: RE: [VÄLJAST] Question - SAIFI / SAIDI calculation
Dear Martin,
I'm trying to answer your question.
The calculation logic of SAIDI is as follows: the total duration of the
interruption of all contractual customers who have experienced an
interruption of more than 3 minutes are summarized and divided by a
fixed number points of consumption (the number of points of consumption
is fixed at the end of last year). Interruptions caused by failure of
the transmission network, failure of the internal electrical
installation, failure of the consumer device shall be filtered out.
The SAIFI calculation logic is as follows: the total number of the
interruption of all contract customers who have experienced an
interruption of more than 3 minutes are summarized and divided by the
number of fixed points of consumption (the number of consumption points
is fixed at the end of last year). Interruptions caused by failure of
the transmission network, failure of the internal electrical
installation, failure of the consumer device shall be filtered out.
Elektrilevi OÜ calculates SAIDI and SAIFI only with contractual
customers who have experienced interruptions over 3 minutes which are
not caused by TSO interruptions, inner interruptions and interruptions
in customer devices. In other words, we do not take into account
customers of other DSO’s.
Kind regards
Tiina Maldre
Adviser of Department of Energy and Postal Communications
Regulatory Division
+372 667 2573 |
www.konkurentsiamet.ee <http://www.konkurentsiamet.ee/> | Tatari 39,
Tallinn 10134 ESTONIA
Estonian Competition Authority
From: [email protected] [mailto:[email protected]]
Sent: Tuesday, March 26, 2019 1:15 PM
To: Konkurentsiamet <[email protected]>
Subject: [VÄLJAST] Question - SAIFI / SAIDI calculation
Dear Sir / Madam,
We are compiling a study focused on electricity supply quality
(particularly in the meaning of distribution continuity) and trying to
understand what is behind SAIFI / SAIDI values presented in various
countries. We have analysed several valuable documents / data files
available on your web page, but still are not sure about one important
issue.
Could you please reveal how SAIFI / SAIDI is calculated for your
distribution system operators? We mean whether in case of an
interruption also interrupted sites / connections of lower voltage
levels (or connected local distributors) are counted into the value of
interrupted customers caused by this interruption or not. This is
important particularly in case of Elektrilevi OÜ supplying several
cities operated by separate distribution system operators.
We would be happy for any feedback.
Best regards,
Martin Továrek
Bořanovická 897
250 65 Bašť
The Czech Republic
+420 721 183 325