Measles and Rubella National Reference Laboratory
Check-list for WHO Accreditation
Section 1: General Review & Overall Findings
Dates of 01/01/2017 - On-site / Desk Review Accreditation for
Review: 31/12/2017 calendar year: 2019
Name of Laboratory of Communicable Diseases, Health Board
Laboratory:
Address: Paldiski mnt 81, 10617 Tallinn
Country Estonia
Phone: +3727943 671 Email:
[email protected] Website: www.terviseamet.
+3727943 635 grete- ee
[email protected]
Head of Institute: Merike Jürilo Head of Department: Külli Rae
Head of Measles and Grete-Katariine Kuum
Rubella Laboratory:
Technical Supervisor: Grete-Katariine Kuum
Number of laboratories under supervision: 1
Name of
Reviewer(s): Dr. Myriam Ben Mamou & Dovile Videbaek, WHO EURO
Name of National Accreditation Authority (if appropriate) and current accreditation status from this
authority (e.g. ISO15189 or other, provide documentation):
Estonian Accreditation Centre certified on 30.06.2014 that Communicable Diseases Laboratory for
HB has competence according to ISO 15189:2007 as a medical laboratory to conduct researches in
the field of clinical and microbiological research. The accreditation shall remain in effect until
29.06.2019.
1
Summary of Accreditation Review
Recommendations (check one):
Accredit: Laboratory meets all criteria
Measles: Rubella:
Serology Serology
Detection RT-PCR/RT-qPCR Detection RT-PCR/RT-qPCR
Sequencing Sequencing
Cell Culture Cell Culture
Measles testing not done Rubella testing not done
Provisionally accredit: Laboratory passed the most recent proficiency test, but needs to
strengthen one or more of the remaining criteria (check off relevant criteria):
Measles: Rubella:
Serology Serology
Detection RT-PCR/RT-qPCR Detection RT-PCR/RT-qPCR
Sequencing Sequencing
Cell Culture Cell Culture
Measles testing not done Rubella testing not done
Do not accredit: Laboratory did not pass the most recent proficiency test and/or did not meet
other performance indicators.
Measles: Rubella:
Serology Serology
Detection RT-PCR/RT-qPCR Detection RT-PCR/RT-qPCR
Sequencing Sequencing
Cell Culture Cell Culture
Measles testing not done Rubella testing not done
2
Main General Findings:
Findings:
Measles and rubella IgM test results are reported by the laboratory to Measles: 98%
1.
the surveillance system within 4 days for ≥ 80% of specimens: Rubella: 92%
Measles: 122
2. IgM tests are performed on at least 50 specimens annually:
Rubella: 126
The laboratory reports to MRLDMS and/or to CISID monthly (WHO Completeness: 92%
3.
Regional Office) Timeliness: 92%
Internal quality control (QC) procedures for serology and molecular diagnostics are
4.
implemented:
Measles: 100%
5. The accuracy of IgM detection is ≥ 90% (20 measles and 25 rubella samples)
Rubella: 100%
Score on most recent WHO Serology proficiency test is ≥ 90%: Measles: 96.77%
6.
PT panel number: 01701 Date reported: 11/09/2017 Rubella: 96.13%
Performance on most recent WHO Molecular EQA (if
Measles Mol detection:
appropriate) is passed (P) /re-test (R), provisionally passed)/fail
Measles Sequencing:
7. (F) NA
Panel for measles: Date reported: Rubella Mol detection:
Panel for rubella: Date reported: Rubella Sequencing:
Virus genotyping (if performed) is completed AND data reported to
8. WHO through MeaNS or RubeNS within 2 months of receipt of specimens, MeaNS: NA
for ≥80% of the specimens appropriate for genetic analysis: RubeNS:
9. Score from on-site review of laboratory operating procedures and practices is ≥ 80%:
Key accreditation criteria
6- Careful attention should be paid to all the criteria involved in final score calculation to
avoid a reduced performance (in-house controls should be used and results should be
reported in 14 days of receipt of the panel).
Conclusion
• Good performance.