[OTIF/RID/CE/2020/2]
29 April 2020
Original: English/French/German
RID 2021
Additional amendments due to enter into force on 1 January 2021
1. As a result of the coronavirus pandemic (COVID-19), the 56th session of the RID Commit-
tee of Experts' has been cancelled and the 12th session of the RID Committee of Experts’
standing working group has been postponed (see letter RID-20009-CE-56 dated 9 April
2020).
2. In consultation with the chair, the Secretariat will submit the decisions of the 10th and 11th
sessions of the standing working group to the RID Committee of Experts for decision in
accordance with Article 21 § 3 of the Rules of Procedure, so that the amendments can
enter into force on 1 January 2021 with a six-month transitional period, as originally
planned. These decisions are set out in document OTIF/RID/CE/2020/1.
3. In addition, it was announced in the above-mentioned letter that, in consultation with the
UNECE Secretariat, the Secretariat will prepare a document setting out necessary correc-
tions to the texts adopted by the 11th session, as well as additional consequential amend-
ments that are required and updated provisions. Before this document is submitted to the
RID Committee of Experts for decision, it will be submitted to the RID Contracting States
for consultation.
4. This document sets out these additional amendments.
Part 1 lists amendments that are necessary to ensure harmonisation between RID and
the UN Recommendations on the Transport of Dangerous Goods, consequential amend-
ments and updates.
Part II lists additional amendments adopted by the Joint Meeting’s working group on tanks.
Part III lists additional amendments to take into account the updating of some standards
referenced in RID and ADR adopted by the Joint Meeting’s working group on standards.
Part IV lists the NHM codes that have to be added to the new entries to be included in
Table B.
[OTIF/RID/CE/2020/2]
Part V contains adapted references to other COTIF Appendices and the corresponding
EU legislation.
Part VI contains corrections to document OTIF/RID/CE/2020/1.
5. Parts II and III also list amendments that concern ADR. These will be deleted from the
final version of this document. The reference documents indicated in square brackets in
this document will also be deleted. Part III contains references to standards highlighted in
yellow that will only be included in the 2021 edition of RID if the corresponding standards
are published by 1 June 2020.
I. Draft amendments for harmonisation of RID with the United Nations Recommenda-
tions on the Transport of Dangerous Goods, consequential amendments, correc-
tions and updates
Chapter 2.2
2.2.41.1.10 [The amendment in the French version does not apply to the English text.]
Chapter 3.3
SP 241 Replace "test No. 1" by:
"test N.1".
SP 310 In the last but one paragraph, delete:
"and packaged in accordance with packing instructions P 908 of 4.1.4.1 or
LP 904 of 4.1.4.3, as applicable".
[Reference: informal document INF.11 submitted to the cancelled spring 2020
session of the RID/ADR/ADN Joint Meeting/correction to the 21st Revised Edi-
tion of the United Nations Recommendations on the Transport of Dangerous
Goods]
SP 377 In the last paragraph, delete:
"and packaged in accordance with packing instruction P 908 of 4.1.4.1 or pack-
ing instruction LP 904 of 4.1.4.3, as applicable".
[Reference: informal document INF.11 submitted to the cancelled spring 2020
session of the RID/ADR/ADN Joint Meeting/correction to the 21st Revised Edi-
tion of the United Nations Recommendations on the Transport of Dangerous
Goods]
SP 643 Amend to read as follows:
"643 Mastic asphalt is not subject to the requirements for Class 9."
[Reference: document ECE/TRANS/WP.15/AC.1/2020/28 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Correction of
the English text]
2
[OTIF/RID/CE/2020/2]
SP 672 At the beginning of the first sentence, replace "Machinery and apparatus" by:
"Articles such as machinery, apparatus or devices".
In the second indent, replace "the machinery or apparatus" by:
"the article".
[Reference: consequential amendment to the amendment to special provision
301]
Chapter 5.4
5.4.2 In footnote 10, in the quotation of IMDG Code 5.4.2.2, at the end of the first
sentence, delete:
"one to the other".
[Reference: consequential amendment following amendment to the IMDG
Code]
Chapter 6.3
6.3.5.3.2.2 (current 6.3.5.3.3) In the introductory sentence, after "in the shape of a drum",
insert:
"or a jerrican".
In sub-paragraphs (a) and (b), replace "chime" by:
"edge".
In sub-paragraph (c), replace "side" by:
"body or side".
[Reference: informal document INF.11 submitted to the cancelled spring 2020
session of the RID/ADR/ADN Joint Meeting/correction to the 21st Revised Edi-
tion of the United Nations Recommendations on the Transport of Dangerous
Goods]
Chapter 6.4
6.4.23.12 In paragraph (a), amend the following:
– Replace "A/132/B(M)F-96" by:
"A/132/B(M)F".
– Replace "A/132/B(M)F-96T" by:
"A/132/B(M)FT".
– Replace "A/139/IF-96" by:
"A/139/IF".
3
[OTIF/RID/CE/2020/2]
– Replace "A/145/H(U)-96" by:
"A/145/H(U)".
In paragraph (b), amend the following:
– Replace "A/132/B(M)F-96" by:
"A/132/B(M)F".
– Replace "CH/28/B(M)F-96" by:
"CH/28/B(M)F".
In paragraph (c), amend the following:
– Replace "A/132/B(M)F-96 (Rev.2)" by:
"A/132/B(M)F (Rev.2)".
– Replace "A/132/B(M)F-96 (Rev.0)" by:
"A/132/B(M)F (Rev.0)".
In paragraph (d), replace "A/132/B(M)F-96(SP503)" by:
"A/132/B(M)F (SP503)".
[Reference: informal document INF.11 submitted to the cancelled spring 2020
session of the RID/ADR/ADN Joint Meeting/correction to the 21st Revised Edi-
tion of the United Nations Recommendations on the Transport of Dangerous
Goods]
II. Draft amendments proposed by the Working Group on Tanks
Table of Contents
6.8.2.6 Replace "and tested" by:
", inspected and tested".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ments INF.8 and INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting. Consequential amendments and corrections.]
6.8.2.7 Replace "and tested" by:
", inspected and tested".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ments INF.8 and INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting. Consequential amendments and corrections.]
4
[OTIF/RID/CE/2020/2]
6.8.3.6 Replace "and tested" by:
", inspected and tested".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ments INF.8 and INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting. Consequential amendments and corrections.]
6.8.3.7 Replace "and tested" by:
", inspected and tested".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ments INF.8 and INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting. Consequential amendments and corrections.]
Chapter 1.4
1.4.2.2.1 In paragraph (d), replace "test" by:
"inspection".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
1.4.3.3 In paragraph (b), replace "test" by:
"inspection".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
1.4.3.4 In paragraph (a), replace "tests" by:
"inspections and tests".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
[The amendment to paragraph (b) in the French version does not apply to the
English text.]
1.4.3.5 In paragraph (a), replace "tests" by:
"inspections and tests".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
5
[OTIF/RID/CE/2020/2]
Chapter 1.6
(ADR:)
1.6.3.2 Replace "tests" by:
"inspections".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
(RID/ADR:)
1.6.3.8 Replace "test" by:
"inspection".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
1.6.3.16 Amend to read as follows:
"1.6.3.16 For tank-wagons and battery-wagons/For fixed tanks (tank-vehicles), demount-
able tanks and battery-vehicles constructed before 1 January 2007 which do
not conform to the requirements of 4.3.2, 6.8.2.3, 6.8.2.4 and 6.8.3.4 concerning
the tank record, the retention of files for the tank record shall start at the latest
at the first periodic inspection after 30 June 2007."
[Reference: document ECE/TRANS/WP.15/AC.1/2020/22 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
(ADR:)
1.6.3.33 [The amendment to the French version does not apply to the English text.]
(RID/ADR:)
1.6.4.5 Replace "test" by:
"inspection".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
1.6.4.18 Amend to read as follows:
"1.6.4.18 For tank-containers and MECGs constructed before 1 January 2007 which do
not conform to the requirements of 4.3.2, 6.8.2.3, 6.8.2.4 and 6.8.3.4 concerning
the tank record, the retention of files for the tank record shall start at the latest
at the first periodic inspection after 30 June 2007."
[Reference: document ECE/TRANS/WP.15/AC.1/2020/22 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
1.6.4.32 [The amendment to the French version does not apply to the English text.]
6
[OTIF/RID/CE/2020/2]
Chapter 4.3
4.3.1.4 Replace "tests" by:
"inspections and tests".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
(ADR:)
Chapter 4.7
After the heading, in Note 2, replace "tests" by:
"inspections and tests".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Consequential
amendments.]
Chapter 6.8
6.8.2.1.23 Amend the first three sentences to read as follows:
"The inspection body performing inspections in accordance with 6.8.2.4.1 or
6.8.2.4.4 shall verify and confirm the ability of the manufacturer or the mainte-
nance or repair shop to perform welding operations and the operation of a weld
quality assurance system."
Amend the last paragraph to read as follows:
"Where there are doubts regarding the quality of welds, including the welds
made to repair any defects revealed by the non-destructive checks, additional
checks of the welds may be required."
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ment INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting, as amended. Consequential amendments.]
6.8.2.3.1 In the last sub-paragraph, in the first sentence, replace "valves and other service
equipment" by:
"service equipment".
In the last sub-paragraph, in the second sentence, replace "the valves and other
service equipment are fit for the intended use" by:
"the service equipment is fit for the intended use".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ment INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting, as amended. Consequential amendments.]
7
[OTIF/RID/CE/2020/2]
(ADR only:)
6.8.2.4.1 [The amendment to the French version does not apply to the English text.]
6.8.2.5.1 In the ninth indent, delete:
"leakproofness".
[Reference: informal documents INF.8 submitted to the cancelled spring 2020
session of the RID/ADR/ADN Joint Meeting. Consequential amendments and
corrections.]
6.8.2.6 In the heading, replace "and tested" by:
", inspected and tested".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ments INF.8 and INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting. Consequential amendments and corrections.]
6.8.2.7 In the heading, replace "and tested" by:
", inspected and tested".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ments INF.8 and INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting. Consequential amendments and corrections.]
6.8.3.6 In the heading, replace "and tested" by:
", inspected and tested".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ments INF.8 and INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting. Consequential amendments and corrections.]
6.8.3.7 In the heading, replace "and tested" by:
", inspected and tested".
[Reference: document ECE/TRANS/WP.15/AC.1/2020/20 and informal docu-
ments INF.8 and INF.30 submitted to the cancelled spring 2020 session of the
RID/ADR/ADN Joint Meeting. Consequential amendments and corrections.]
8
[OTIF/RID/CE/2020/2]
III. Draft amendments proposed by the Working Group on Standards
Chapter 3.3
SP 658 In the introductory sentence, replace "EN ISO 9994:2006 + A1:2008" by:
"EN ISO 9994:2019".
Chapter 4.1
P 200 In paragraph (11), amend the Table as follows:
– In the fifth row (current sixth row), in column "Reference", replace
"ISO 11372:2011" by:
"EN ISO 11372:2011".
– In the fifth row (current sixth row), in column "Title of document", delete the
Note.
– In sixth row (current seventh row), in column "Reference", replace
"ISO 13088:2011" by:
"EN ISO 13088:2011".
– In the sixth row (current seventh row), in column "Title of document", delete
the Note.
In paragraph (12) 3.4, replace "EN ISO 14245:2010 or EN ISO 15995:2010" by:
"EN ISO 14245:2010, EN ISO 14245:2019, EN ISO 15995:2010 or
EN ISO 15995:2019".
4.1.6.15 Amend the Table for "4.1.6.8 Valves with inherent protection" as follows:
– In the fourth row, in column "Reference", replace "EN ISO 14245:2010" by:
"EN ISO 14245:2010 or EN ISO 14245:2019".
– In the fourth row, in column "Title of document", delete:
"(ISO 14245:2006)".
– In the fifth row, in column "Reference", replace "EN ISO 15995:2010" by:
"EN ISO 15995:2010 or EN ISO 15995:2019".
– In the fifth row, in column "Title of document", delete:
"(ISO 15995:2006)".
9
[OTIF/RID/CE/2020/2]
Chapter 6.2
6.2.3.5.1 In Note 2, replace "EN ISO 16148:2016" by:
"EN ISO 16148:2016 + A1:2020".
[Subject to the availability of amendment A1.]
6.2.4.1 Amend the Table, under "for design and construction" as follows:
– For "EN ISO 10961:2012" in column (4), replace "Until further notice" by:
"Between 1 January 2013 and 31 December 2022".
– After the row for "EN ISO 10961:2012", insert the following new row:
"
(1) (2) (3) (4) (5)
6.2.3.1 Until fur-
EN ISO Gas cylinders – Cylinder bundles – De-
and ther no-
10961:2019 sign, manufacture, testing and inspection
6.2.3.4 tice
"
– For "EN ISO 7866:2012 + AC:2014", "EN ISO 9809-1:2010",
"EN ISO 9809-2:2010" and "EN ISO 9809-3:2010" in column (2), delete the
reference to the ISO standard.
Amend the Table, under "for closures", as follows:
– For "EN ISO 14245:2010", in column (2), delete:
"(ISO 14245:2006)".
– For "EN ISO 14245:2010", in column (4), replace "Until further notice" by:
"Between 1 January 2013 and 31 December 2022".
– After the row for "EN ISO 14245:2010", insert the following new row:
"
(1) (2) (3) (4) (5)
Gas cylinders – Specifications and 6.2.3.1 Until fur-
EN ISO 14245:2019 testing of LPG cylinder valves – Self- and ther no-
closing 6.2.3.3 tice
"
– For "EN ISO 15995:2010", in column (2), delete:
"(ISO 15995:2006)".
– For "EN ISO 15995:2010", in column (4), replace "Until further notice" by:
"Between 1 January 2013 and 31 December 2022".
– After the row for "EN ISO 15995:2010", insert the following row:
"
(1) (2) (3) (4) (5)
Gas cylinders – Specifications and 6.2.3.1 Until fur-
EN ISO 15995:2019 testing of LPG cylinder valves – Man- and ther no-
ually operated 6.2.3.3 tice
"
10
[OTIF/RID/CE/2020/2]
– For "EN 13175:2014", in column (4), replace "Until further notice" by:
"Between 1 January 2017 and 31 December 2022".
– After the row for "EN 13175:2014", insert the following new row:
"
(1) (2) (3) (4) (5)
EN 13175:2019 (ex- LPG Equipment and accessories –
6.2.3.1 Until fur-
cept clause 6.1.6) Specification and testing for Liquefied
and ther no-
[EN 13175:2019 + Petroleum Gas (LPG) pressure vessel
6.2.3.3 tice
A1:2020] valves and fittings
"
[Subject to the availability of amendment A1.]
– For "EN ISO 17871:2015", in column (2), delete:
"(ISO 17871:2015)".
– For "EN ISO 14246:2014", in column (2), delete:
"(ISO 14246:2014)".
– At the end add the following new row:
"
(1) (2) (3) (4) (5)
LPG Equipment and accessories –
6.2.3.1,
EN 14129:2014 (ex- Pressure relief valves for LPG pres- Until fur-
6.2.3.3
cept the note in sure vessels ther no-
and
clause 3.11) NOTE: This standard is applicable to tice
6.2.3.4
pressure drums.
"
6.2.4.2 In the Table, in column (2), delete:
"(ISO 10462:2013)" and "(ISO 22434:2006)".
(ADR only:)
Chapter 6.8
6.8.2.6.1 Amend the Table under "For equipment" as follows:
– For "EN 13175:2014", in column (4), replace "Until further notice" by:
"Between 1 January 2017 and 31 December 2022".
– After the row for "EN 13175:2014", insert the following new row:
"
(1) (2) (3) (4) (5)
6.8.2.1.1,
EN ISO 13175:2019 LPG Equipment and accessories –
6.8.2.2, Until fur-
(except clause 6.1.6) Specification and testing for Liquefied
6.8.2.4.1 ther no-
[EN 13175:2019 + Petroleum Gas (LPG) pressure vessel
and tice
A1:2020] valves and fittings
6.8.3.2.3
"
[Subject to the availability of amendment A1.]
11
[OTIF/RID/CE/2020/2]
IV. NHM codes for the new entries to be included in Table B
At the request of the RID Committee of Experts’ standing working group (see report
OTIF/CE/GTP/2019-A, paragraph 5), the representative of UIC has informed the Secre-
tariat of the NHM codes for the new substances to be included in Table B.
Amend the amendment instruction in document OTIF/RID/CE/2020/1 relating to the new
entries to be included in Table B as follows:
"Insert the following new entries in alphabetical order:
Name and description UN Note NHM
No. Code
DANGEROUS GOODS IN ARTICLES 3363 8+++++
DETONATORS, ELECTRONIC programmable 0511 360300
for blasting
DETONATORS, ELECTRONIC programmable 0512 360300
for blasting
DETONATORS, ELECTRONIC programmable 0513 360300
for blasting
MEDICAL WASTE, CATEGORY A, AFFECT- 3549 382530
ING HUMANS, solid
MEDICAL WASTE, CATEGORY A, AFFECT- 3549 382530
ING ANIMALS only, solid
"
V. Adapted references to other COTIF Appendices and the corresponding EU legisla-
tion
1.2.1 Amend footnote 5 concerning the definition of “Operator of a tank-wagon” (for-
mer definition of “Operator of a tank-container, portable tank or tank-
wagon”) to read as follows:
“5 “The term "operator" is equivalent to the term "keeper" as defined in Article
2, n) of Appendix G to COTIF (ATMF) and in Article 3.19 of Directive (EU)
2016/798 of the European Parliament and of the Council of 11 May 2016 on
railway safety and Article 2.21 of Directive (EU) 2016/797 of the European
Parliament and of the Council of 11 May 2016 on the interoperability of the
rail system within the European Union.”
Amend footnote 4 concerning the definition of “Entity in charge of mainte-
nance (ECM)” to read as follows:
“4 With respect to elements related to entities in charge of maintenance (ECM)
and their certification, Appendix G to COTIF (ATMF), is harmonised with Eu-
ropean legislation, particularly Directive (EU) 2016/798 of the European Par-
liament and of the Council of 11 May 2016 on railway safety (Article 14 points
1 to 5) and Directive (EU) 2016/797 of the European Parliament and of the
Council of 11 May 2016 on the interoperability of the rail system within the
European Union (Article 47 point 3 letter f). With respect to the system on
certification of entities in charge of maintenance, Annex A to ATMF is equiv-
alent to Commission Regulation (EU) 445/2011 on a system of certification
of entities in charge of maintenance for freight wagons.”
12
[OTIF/RID/CE/2020/2]
1.4.2.2.8 Amend “as defined in Article 15 § 3 of ATMF – Appendix G to COTIF – and in
Article 5 of Annex A to ATMF [...]” to read:
“as defined in Article 15 § 3 of Appendix G to COTIF (ATMF) and in Annex A to
ATMF [...]”.
1.4.3.5 In pargraph (e), amend “as defined in Article 15 § 3 of ATMF – Appendix G to
COTIF – and in Article 5 of Annex A to ATMF [...]” to read:
“as defined in Article 15 § 3 of Appendix G to COTIF (ATMF) and in Annex A to
ATMF [...]”.
1.4.3.8 In paragraph (b), amend “as defined in Article 15 § 3 of ATMF – Appendix G to
COTIF – and in Article 5 of Annex A to ATMF [...]” to read:
“as defined in Article 15 § 3 of Appendix G to COTIF (ATMF) and in Annex A to
ATMF [...]”.
6.8.2.5.2 Amend footnote 17 (formerly footnote 15) to read as follows:
“17 Vehicle keeper marking in accordance with the Uniform Technical Prescrip-
tion applicable to Vehicle Numbers and linked alphabetical marking on the
bodywork (UTP Marking) and in accordance with the corresponding Euro-
pean Union legislation.”
6.8.3.5.11 Amend footnote 21 (formerly footnote 20) to read as follows:
“21 Vehicle keeper marking in accordance with the Uniform Technical Prescrip-
tion applicable to Vehicle Numbers and linked alphabetical marking on the
bodywork (UTP Marking) and in accordance with the corresponding Euro-
pean Union legislation.”
VI. Corrections to the amendments in document OTIF/RID/CE/2020/1
Chapter 1.1
1.1.3.6.3 [The correction in the French version does not apply to the English text.]
Chapter 4.1
4.1.1 The second amendment reads as follows:
"In the Note, amend the text in parentheses at the end of the sentence to read:
"(P 201, P 207 and LP 200 for Class 2 and P 620, P 621, P 622, IBC 620,
LP 621 and LP 622 for Class 6.2)"."
4.1.4.1
P 200 Replace the amendments to the Table in paragraph (11) by the following
amendment:
"In paragraph (11), in the Table, delete the fifth row ("ISO 24431:2006")."
[Reference: proposed by the working group on standards.]
13
[OTIF/RID/CE/2020/2]
4.1.6.15 The amendment for standard "ISO 11117" reads as follows:
"– For "4.1.6.8 (b) and (c)", replace "ISO 11117:1998 or ISO 11117:2008 +
Cor 1:2009" by:
"ISO 11117:1998 or EN ISO 11117:2008 + Cor 1:2009 or
EN ISO 11117:2019".
[Reference: proposed by the working group on standards.]
Chapter 6.2
6.2.4.2 The second amendment for standard "EN 1440:2016 (except annex C)" reads
as follows:
"– After the row for "EN 1440:2016 (except annex C)", insert the following new
row:
"
(1) (2) (3)
EN 1440:2016 +
LPG equipment and accessories – Transportable refillable Mandatorily
A1:2018 +
traditional welded and brazed steel Liquefied Petroleum from 1 January
A2:2020 (except
Gas (LPG) cylinders – Periodic inspection 2022
Annex C)
""
[Reference: proposed by the working group on standards.]
The second amendment for standard "EN 16728:2016 (except clause 3.5, An-
nex F and Annex G)" reads as follows:
"– After the existing row for "EN 16728:2016 (except clause 3.5, Annex F and
Annex G)", insert the following new row:
"
(1) (2) (3)
LPG equipment and accessories – Transportable refilla- Mandatorily
EN 16728:2016 +
ble LPG cylinders other than traditional welded and from 1 January
A1:2018 + A2:2020
brazed steel cylinders – Periodic inspection 2022
""
[Reference: proposed by the working group on standards.]
Chapter 6.8
6.8.2.6.1 The second amendment for standard "EN 14025:2013 + A1:2016 (except An-
nex B)" reads as follows:
– After "EN 14025:2013 + A1:2016 (except Annex B)", insert the following
new rows:
"
(1) (2) (3) (4) (5)
Tanks for the transport of dangerous goods
– Metallic pressure tanks – Design and
construction 6.8.2.1 Until fur-
EN 14025:2018 +
NOTE: Materials of shells shall at least and ther no-
AC:2020
be attested by a type 3.1 certifi- 6.8.3.1 tice
cate issued in accordance with
standard EN 10204.
Tanks for transport of dangerous goods –
Mandato-
EN 12972:2018 Testing, inspection and marking of metallic 6.8.2.3
rily from
tanks
14
[OTIF/RID/CE/2020/2]
1 Janu-
ary 2022
"
[Reference: proposed by the working group on standards.]
Chapter 6.10
6.10.3.8 The amendment reads as follows:
"6.10.3.8 In paragraph (a), add a new Note to read as follows:
"NOTE: This requirement may, for example, be complied with by the use of a
vertical pipe discharging at the top, or a low-level outlet with a con-
nection which allows attachment of a hose."
[Reference: document ECE/TRANS/WP.15/AC.1/2020/15 submitted to the can-
celled spring 2020 session of the RID/ADR/ADN Joint Meeting. Correction.)
Chapter 6.11
6.11.4.1 Amend footnotes 2 and 3 to read:
"2 First edition of IRS (International Railway Solution) applicable as from
1 June 2020.
3
Second edition of IRS (International Railway Solution) applicable as from
1 December 2020."
[Reference: informal document INF.29 submitted to the cancelled spring 2020
session of the RID/ADR/ADN Joint Meeting. Correction.]
Chapter 7.1
7.1.3 Amend footnotes 1 and 2 to read:
"1 First edition of IRS (International Railway Solution) applicable as from
1 June 2020.
2
Second edition of IRS (International Railway Solution) applicable as from
1 December 2020."
[Reference: informal document INF.29 submitted to the cancelled spring 2020
session of the RID/ADR/ADN Joint Meeting. Correction.]
__________
15
Saatja: Jochen Conrad <
[email protected]>
Saadetud: 29.04.2020 13:19
Teema: Consultation on the 2021 amendments to RID
Ladies and Gentlemen,
As a result of the coronavirus pandemic (COVID-19), the 56th session of
the RID Committee of Experts has been cancelled and the 12th session of
the RID Committee of Experts standing working group has been postponed
(see letter RID-20009-CE-56 dated 9 April 2020). The 108th session of
WP.15 that was to meet from 11 to 15 May 2020 has also been cancelled.
Attached in the annex are documents [OTIF/RID/CE/2020/1] and
[OTIF/RID/CE/2020/2] containing the amendments to RID that should enter
into force on 1 January 2021. Document [OTIF/RID/CE/2020/1] contains the
amendments that have already been adopted by the RID Committee of Experts
standing working group in November 2019. Document [OTIF/RID/CE/2020/2]
contains additional necessary amendments, which have been prepared in
close cooperation with the UNECE Secretariat. These consist of
corrections and consequential amendments to the texts adopted by the
standing working group, as well as additional corrections and amendments
proposed by the RID/ADR/ADN Joint Meetings working groups on tanks and
standards. To make it easier to check the proposed amendments, each of the
reference documents from the cancelled RID/ADR/ADN Joint Meeting is shown
in square brackets. The report of the Joint Meetings working group on
standards is also attached.
Owing to the cancellation of the RID Committee of Experts, both these
documents need to be adopted using the written procedure provided for in
Article 21 § 3 of the RID Committee of Experts Rules of Procedure. In
order to avoid any possible controversy before the vote in writing, we
are sending you these two documents for consultation beforehand.
If you have any comments on the individual amendments, we should be
grateful if you could send them to us by email. In so doing, please note
that all the amendments in document [OTIF/RID/CE/2020/1] have already
been adopted by the standing working group and, insofar as they concern
amendments that concern all the transport modes, they have already been
adopted for ADR by the 107th session of WP.15. The exception to this is
the amendment to the footnote in 6.8.2.1.2, which was placed in square
brackets at the last session of the standing working group, and minor
editorial amendments, which are indicated as such in the document.
Any contentious issues could then be dealt with in a video conference
that has been scheduled for Wednesday, 13 May at 10.00 Central European
Summer Time. You will receive a separate invitation to this video
conference from the Chair of the RID Committee of Experts, Ms Caroline
Bailleux. The video conference will be held using MS Teams.
The video conference will be held in English as follows, without
interpretation:
Registration (10 minutes)
Introduction and explanation of how the conference will work
Presentation of documents
Presentation of comments received
Presentation of further procedure
Conclusions.
The Chair and the Secretariat are aware that it will be more difficult to
examine the amendments in this manner than in a discussion at a normal
session of the RID Committee of Experts or its standing working group.
However, we are convinced that this is the best option in the current
circumstances. We can assure you that the corrections and amendments
proposed have been examined in detail.
Best regards
Jochen Conrad
Head of Dangerous Goods Department
Organisation intergouvernementale pour les transports internationaux
ferroviairesZwischenstaatliche Organisation für den internationalen
EisenbahnverkehrIntergovernmental Organisation for International Carriage
by Rail
Gryphenhübeliweg 30
CH-3006 Bern/Berne
Tel : + 41 31 359 10 17
Mobile : + 41 79 555 10 17
Fax : + 41 31 359 10 11
This e-mail and any attachments may contain privileged or confidential
information and is intended exclusively for the use of the addressee.
If you receive this e-mail in error, please contact the sender and
promptly delete the material from your computer.
INF.XX
Economic Commission for Europe
Inland Transport Committee
Working Party on the Transport of Dangerous Goods 7 April 2020
108th session
Geneva, 11–15 May 2020
Item 4 of the provisional agenda
Work of the RID/ADR/ADN Joint Meeting
Report of the Standards Working Group (30th meeting)
1. Reference is made to document ECE/TRANS/WP.15/AC.1/2020/11, which informs
about the progress made in the establishment of new and the revision of published EN and
EN ISO standards referenced or intended to be referenced in the RID/ADR/ADN.
2. A teleconference took place on the 10th February to review the comments made by
Contracting Parties/States. Comments were compiled by CCMC (see INF.18).
3. Results
3.1 The proposals made in this report are made on the basis of INF.18, but subsequently
a decision has been made to propose the elimination of the references to the identical ISO
standard sometimes shown in brackets at the end of the title on EN ISO standards. These
references in brackets are shown inconsistently and do not aid the reader in identifying the
correct standard.
3.2 Five revised standards and three amended standards are recommended to be
referenced together with a Corrigendum to EN 14025:2018.
3.3 Editorial changes to the table of standards in P200 (11) are proposed to align it with
the presentation of standards previously agreed for 4.1.6.15.
3.4 Two revised general purpose standard had been identified, one occurs in UN text and
the other may be adopted in Special Provision 658.
3.5 EN 13922 Tanks for the transport of dangerous goods – Service equipment of tanks –
Overfill prevention systems for liquid fuels may be of interest for the ADR in the future and
could be mentioned in 4.3.2.2 as a possible means of avoiding overfilling.
3.6 INF.24 was also added to the agenda for the Working Group and the proposal is
recommended for adoption by the Joint Meeting with a minor modification.
4. Proposed additions to the list of standards for reference in RID/ADR 2021
4.1. Draft amendments relating to standard EN ISO 16148:2016 +A1:2020
6.2.3.5.1 In NOTE 2, replace “EN ISO 16148:2016” by “EN ISO 16148:2016 +
A1:2020”.
4.2. Draft amendments relating to standard EN 13175:2019
This standard has an error in clause 6.1.6 which describes the measures required for valve
protection incorrectly. It is therefore proposed to exclude this clause from the reference.
However an amendment (A1:2020) which will correct this clause is being processed by CEN,
but it may not be published in time for the 2021 edition of RID/ADR. Consequently, the
Standards WG has put the amended version in square brackets pending its publication.
6.2.4.1 Amend the Table, under “for closures”, as follows:
For “EN 13175:2014”, in column (4), replace “Until further notice” by “Between 1
January 2017 and 31 December 2022”. After the row for “EN 13175:2014”, insert the
following row:
INF.XX
EN 13175:2019 LPG Equipment and accessories –
(except clause 6.1.6) Specification and testing for Until
6.2.3.1 and
Liquefied Petroleum Gas (LPG) further
[EN 13175:2019 + 6.2.3.3
pressure vessel valves and fittings notice
A1:2020]
6.8.2.6.1 Amend the table under “for equipment” as follows:
For “EN 13175:2014”, in column (4), replace “Until further notice” by “Between 1
January 2017 and 31 December 2022”. After the row for “EN 13175:2014”, insert the
following row:
EN 13175:2019 LPG Equipment and accessories – 6.8.2.1.1,
(except clause 6.1.6) Specification and testing for Until
6.8.2.2,
Liquefied Petroleum Gas (LPG) further
[EN 13175:2019 + 6.8.2.4.1 and
pressure vessel valves and fittings notice
A1:2020] 6.8.3.2.3
4.3. Draft amendments relating to standard EN 16728:2016 + A1:2018 (new text in
bold)
6.4.2.2 Correct the draft amendment to RID/ADR
For EN 16728:2016 + A1:2018 read EN 16728:2016 + A1:2018 + A2:2020.
4.4. Draft amendments relating to standard EN 1440:2016 + A1:2018 (new text in bold)
6.4.2.2 Correct the draft amendment to RID/ADR
For EN 1440:2016 + A1:2018 (except Annex C) read EN 1440:2016 + A1:2018 +
A2:2020 (except Annex C).
4.5. Draft amendments relating to standard EN ISO 10961:2019
6.2.4.1 Amend the table, under “for design and construction”, as follows:
For “EN ISO 10961:2012”, in column (4), replace “Until further notice” by “Between 1
January 2013 and 31 December 2022”. After the row for “EN ISO 10961:2012”, insert the
following row:
Gas cylinders – Cylinder bundles – Design, Until
EN ISO 6.2.3.1 and
manufacture, testing and inspection further
10961:2019 6.2.3.4
notice
4.6. Draft amendments relating to standard EN ISO 11117:2019 (new text in bold)
4.1.6.15 In the table for “4.1.6.8 (b) and (c)” correct the draft amendment to RID/ADR
– For ISO 11117:1998 or EN ISO 11117:2008 + Cor 1:2009 read ISO 11117:1998 or EN
ISO 11117:2008 + Cor 1:2009 or EN ISO 11117:2019.
4.7. Draft amendments relating to standard EN ISO 14245:2019 and EN ISO
15995:2019
P200 (12) 3.4 (new text shown in bold):
Replace “EN ISO 14245:2010 or EN ISO 15995:2010” by “EN ISO 14245:2010, EN ISO
14245:2019, EN ISO 15995:2010 or EN ISO 15995:2019”.
4.1.6.15, in the table, for Valves with inherent protection amend the fourth and fifth rows as
shown.
4.1.6.8 EN ISO 14245:2010 or Gas cylinders – Specifications and testing of LPG
Valves EN ISO 14245:2019 cylinder valves – Self closing (ISO 14245:2006)
with
EN ISO 15995:2010 or Gas cylinders – Specifications and testing of LPG
inherent
EN ISO 15995:2019 cylinder valves – Manually operated (ISO
protection
15995:2006)
2
INF.XX
6.2.4.1 Amend the table, under “for closures”:
For “EN ISO 14245:2010”, in column (2), delete “(ISO 14245:2006) and in column (4),
replace “Until further notice” by “Between 1 January 2013 and 31 December 2022”. After
the row for “EN ISO 14245:2010”, insert the following row:
EN ISO Gas cylinders – Specifications and testing 6.2.3.1 and Until
14245:2019 of LPG cylinder valves – Self-closing 6.2.3.3 further
notice
For “EN ISO 15995:2010”, in column (2), delete “(ISO 15995:2006) and in column (4),
replace “Until further notice” by “Between 1 January 2013 and 31 December 2022”. After
the row for “EN ISO 15995:2010”, insert the following row:
Gas cylinders – Specifications and testing Until
EN ISO of LPG cylinder valves – Manually 6.2.3.1 and
further
15995:2019 operated 6.2.3.3
notice
4.8. Draft amendments relating to standard EN 14025:2018 (new text in bold)
6.8.2.6.1 Correct the draft amendment to RID/ADR
For EN 14025:2018 read EN 14025:2018 + AC:2020.
4.9 Draft amendment relating to standard EN 14129:2014 (proposed in INF.24)
Scrutiny of the standard showed that clause 3.11 includes an informative note quoting
information from ADR which is only applicable to pressure relief valves fitted to tanks. The
standard will still make sense if this note is excluded from the reference. Otherwise the
standard is suitable for this application.
6.2.4.2.1 Add a new row to the end of the table “for closures”
EN LPG Equipment and accessories - Pressure 6.2.3.1, Until
14129:2014 relief valves for LPG pressure vessels 6.2.3.3 and further
(except the NOTE: This standard is applicable to 6.2.3.4 notice
note in pressure drums.
clause 3.11)
5. Amendment to P200 (11)
The Working Group on Standards proposes align the presentation of P200 (11) with that
adopted at the last session for 4.1.6.15. That is, this table will reference the EN ISO version
wherever such a version exists, thus eliminating the need for the Note “NOTE: The EN
version of this ISO standard fulfils the requirements and may also be used “.
5.1 Correct the amendment to RID/ADR as shown:
Delete the row for “(7) (a) ISO 24431:2006”. In the line for “(7) EN ISO 24431:2016”,
replace “EN ISO 24431:2016” by “ISO 24431:2016” and add the following Note in column
“Title of document”: “NOTE: The EN version of this ISO standard fulfils the requirements
and may also be used.”.
5.2 In the line for “(7) (a) and (10) (p) ISO 11372:2011”, replace “ISO 11372:2011” by
“EN ISO 11372:2011” and delete the Note in column “Title of document”.
5.3 In the line for “(7) (a) and (10) (p) ISO 13088:2011”, replace “ISO 13088:2011” by
“EN ISO 13088:2011” and delete the Note in column “Title of document”.
6. General Purpose Standards
6.1 prEN ISO 16106 - Transport packages for dangerous goods - Dangerous goods
packagings, intermediate bulk containers (IBCs) and large packagings - Guidelines for the
application of ISO 9001 (ISO/DIS 16106:2018)
3
INF.XX
Comment: The previous version of the above standard (ISO 16106:2006) is referenced
in the UN Model Regulations/RID/ADR in a Note appearing in 6.1.1.4, 6.3.2.2, 6.5.4.1 and
6.6.1.2. It is suggested that this revised standard, when published, should be considered by
the UN Sub Committee of Experts.
6.2 EN ISO 9994:2019 - Lighters - Safety specification
Comment: The previous version of this standard (EN ISO 9994:2006 + A1:2008)
appears in Special Provision 658 of RID/ADR. The Joint Meeting may choose to adopt the
following proposal.
SP 658 Replace “EN ISO 9994:2006 + A1:2008” by “EN ISO 9994:2019”.
7. Removal of bracketed references to ISO standards in 6.2.4
6.2.4.1 In the table, under “for design and construction”:
For “EN ISO 7866:2012 + AC:2014”, “EN ISO 9809-1:2010”, “EN ISO 9809-2:2010”
and “EN ISO 9809-3:2010”, delete the reference to the ISO standard in column (2).
6.2.4.1 In the table under “for closures”:
For “EN ISO 17871:2015” and “EN ISO 14246:2014”, delete the reference to the ISO
standard in column (2)
6.2.4.2 In the table
For “EN ISO 10462:2013” and “EN ISO 2234:2011”, delete the reference to the ISO
standard in column (2)
4
INF.XX
Annex
Amendments proposed by the Working Group on Standards
Chapter 3.3
SP 658
Replace “EN ISO 9994:2006 + A1:2008” by “EN ISO 9994:2019”.
Chapter 4.1
4.1.4.1, P200 (11)
• In the line for “(7) (a) and (10) (p) ISO 11372:2011”, replace “ISO
11372:2011” by “EN ISO 11372:2011” and delete the Note in column “Title
of document”.
• In the line for “(7) (a) and (10) (p) ISO 13088:2011”, replace “ISO
13088:2011” by “EN ISO 13088:2011” and delete the Note in column “Title
of document”.
4.1.4.1, P200 (12) 3.4
Replace “EN ISO 14245:2010 or EN ISO 15995:2010” by “EN ISO
14245:2010, EN ISO 14245:2019, EN ISO 15995:2010 or EN ISO
15995:2019”.
4.1.6.15, in the table, for “4.1.6.8 Valves with inherent protection”:
• In the fourth row, second column, replace “EN ISO 14245:2010” by “EN ISO
14245:2010 or EN ISO 14245:2019”. Delete “(ISO 14245:2006)” in the third
column.
• In the fifth row, second column, replace “EN ISO 15995:2010” by “EN ISO
15995:2010 or EN ISO 15995:2019”. Delete “(ISO 15995:2006)” in the third
column.
Chapter 6.2
6.2.3.5.1 In NOTE 2, replace “EN ISO 16148:2016” by “EN ISO 16148:2016 +
A1:2020”.
6.2.4.1 In the table, under “for design and construction”:
• For “EN ISO 10961:2012”, in column (4), replace “Until further notice” by
“Between 1 January 2013 and 31 December 2022”. After the row for “EN ISO
10961:2012”, insert the following row:
EN ISO Gas cylinders – Cylinder bundles – Design, 6.2.3.1 and Until further
10961:2019 manufacture, testing and inspection 6.2.3.4 notice
• For “EN ISO 7866:2012 + AC:2014”, “EN ISO 9809-1:2010”, “EN ISO 9809-
2:2010”, “EN ISO 9809-3:2010”, delete the reference to the ISO standard in
column (2).
6.2.4.1 In the table, under “for closures”:
• For “EN ISO 14245:2010”, in column (2), delete “(ISO 14245:2006)” and in
column (4), replace “Until further notice” by “Between 1 January 2013 and 31
December 2022”. After the row for “EN ISO 14245:2010”, insert the following
row:
5
INF.XX
EN ISO Gas cylinders – Specifications and testing of 6.2.3.1 and Until further
14245:2019 LPG cylinder valves – Self-closing 6.2.3.3 notice
• For “EN ISO 15995:2010”, in column (2), delete “(ISO 15995:2006)” and in
column (4), replace “Until further notice” by “Between 1 January 2013 and 31
December 2022”. After the row for “EN ISO 15995:2010”, insert the following
row:
EN ISO Gas cylinders – Specifications and testing of 6.2.3.1 and Until further
15995:2019 LPG cylinder valves – Manually operated 6.2.3.3 notice
• For “EN 13175:2014”, in column (4), replace “Until further notice” by
“Between 1 January 2017 and 31 December 2022”. After the row for “EN
13175:2014”, insert the following row:
EN 13175:2019 LPG Equipment and accessories –
(except clause 6.1.6) Specification and testing for Liquefied 6.2.3.1 and Until further
[EN 13175:2019 + Petroleum Gas (LPG) pressure vessel 6.2.3.3 notice
A1:2020] valves and fittings
• For “EN ISO 17871:2015”, in column (2), delete “(ISO 17871:2015)”.
• For “EN ISO 14246:2014”, in column (2), delete “(ISO 14246:2014)”.
• At the end add the following new row:
EN 14129:2014 LPG Equipment and accessories – Pressure 6.2.3.1, Until further
(except the note relief valves for LPG pressure vessels 6.2.3.3 and notice
in clause 3.11) NOTE: This standard is applicable to 6.2.3.4
pressure drums.
6.2.4.2 In column (2) of the table, delete “(ISO 10462:2013)” and “(ISO
22434:2006)”.
Chapter 6.8
6.8.2.6.1 Amend the table as follows:
Under “For equipment”:
• For “EN 13175:2014”, in column (4), replace “Until further notice” by
“Between 1 January 2017 and 31 December 2022”. After the row for “EN ISO
13175:2014”, insert the following row:
EN 13175:2019 LPG Equipment and accessories – 6.8.2.1.1,
(except clause 6.1.6) Specification and testing for Liquefied 6.8.2.2, Until further
[EN 13175:2019 + Petroleum Gas (LPG) pressure vessel 6.8.2.4.1 and notice
A1:2020] valves and fittings 6.8.3.2.3
Corrigendum to the draft amendments to annexes A et B to ADR
• Chapter 4.1, 4.1.4.1, P200 (11)
For the existing text, substitute
Delete the row for “(7) (a) ISO 24431:2006”.
• Chapter 4.1, 4.1.6.15, in the table, for “4.1.6.8 (b) and (c)”, amendment related to
standard ISO 11117
6
INF.XX
For ISO 11117:1998 or EN ISO 11117:2008 + Cor 1:2009 read ISO 11117:1998 or EN ISO
11117:2008 + Cor 1:2009 or EN ISO 11117:2019.
• Chapter 6.2, 6.2.4.2, amendment related to standard EN 1440:2016 + A1:2018
For EN 1440:2016 + A1:2018 (except Annex C) read EN 1440:2016 + A1:2018 + A2:2020
(except Annex C).
• Chapter 6.2, 6.2.4.2, amendment related to standard EN 16728:2016 + A1:2018
For EN 16728:2016 + A1:2018 read EN 16728:2016 + A1:2018 + A2:2020.
• Chapter 6.8, 6.8.2.6.1, amendment related to standard EN 14025:2018
For EN 14025:2018 read EN 14025:2018 + AC:2020.
7
[OTIF/RID/CE/2020/1]
29 April 2020
Original: English/French/German
1 January 2021 edition of RID
Texts adopted by the 11th session of the RID Committee of Experts' standing working group (Vienna,
25 to 28 November 2019) to enter into force on 1 January 2021
Information from the Secretariat
1. As a result of the coronavirus pandemic (COVID-19), the 56th session of the RID Committee of Experts'
has been cancelled and the 12th session of the RID Committee of Experts’ standing working group has
been postponed (see letter RID-20009-CE-56 dated 9 April 2020).
2. In this document, the Secretariat has collated those amendments that have already been adopted by
the 11th session of the standing working group (Vienna, 25 to 28 November 2019).
3. This document also contains some text that is highlighted in yellow. These parts have not yet been
checked by the standing working group. These are necessary corrections and amendments which the
Secretariat noticed when incorporating the amendments into the text of RID. The German version also
contains some editorial adaptations that were noticed in connection with the German translation of the
ICAO Technical Instructions.
4. Before this document is submitted for decision under the written procedure according to Article 21 § 3
of the Rules of Procedure, it is being submitted to participants of the RID Committee of Experts for
consultation.
5. The amendment to 6.8.2.1.2 footnote 1 was left in square brackets at the last session of the standing
working group because the representative of ERA entered a general reservation (see report
OTIF/RID/CE/GTP/2019-A, paragraphs 29 to 31). If the consultation does not result in agreement with
regard to including this amendment, it will be removed from the final version of the document used for
the written procedure.
6. All the amendments should enter into force on 1 January 2021 with a six month transitional period.
[OTIF/RID/CE/2020/1]
TITLE PAGE
Replace "With effect from 1 January 2019" by:
"With effect from 1 January 2021".
Replace "This text replaces the requirements of 1 January 2017." by:
"This text replaces the requirements of 1 January 2019."
Replace "The following are RID Contracting States (as at 1 May 2019):" by:
"The following are RID Contracting States (as at 1 July 2020):".
[Under the RID Contracting States, insert:]
TABLE OF CONTENTS
2.3.2 Amend "Class 4.1" to read:
"Class 1 and Class 4.1".
5.5.3 After "applicable to", insert:
"the carriage of dry ice (UN 1845) and to".
At the end of the title, in the text in parentheses, after "(UN 1951)", add:
"or nitrogen".
5.5 Add a new 5.5.4 to read as follows:
"5.5.4 Dangerous goods contained in equipment in use or intended for use during carriage,
attached to or placed in packages, overpacks, containers or load compartments".
Part 6 At the end, replace "and tanks" by:
", tanks and bulk containers".
6.3 At the end, add:
"(UN Nos. 2814 and 2900)".
PART 1
Chapter 1.1
1.1.3.6.3 In the Table, for transport category 0, Class 6.2, replace "UN Nos 2814 and 2900" by:
"UN Nos. 2814, 2900 and 3549".
1.1.3.7 In paragraph (b), at the end, add:
", except for equipment such as data loggers and cargo tracking devices attached to
or placed in packages, overpacks, containers or load compartments which are only
subject to the requirements in 5.5.4".
2
[OTIF/RID/CE/2020/1]
1.1.4.4.3 Amend to read as follows:
"1.1.4.4.3 Carriage of trailers carrying packages
If a trailer becomes separated from its tractor unit, the orange-coloured plate in ac-
cordance with 5.3.2 of ADR and the mark in accordance with Chapter 3.4 of ADR
affixed at the rear of the trailer shall also be affixed to its front. However, the orange-
coloured plate need not be affixed to the front of the trailer if the corresponding plac-
ards are affixed to both sides."
Chapter 1.2
1.2.1 Insert the following new definition for "Dose rate":
""Dose rate" means the ambient dose equivalent or the directional dose equivalent,
as appropriate, per unit time, measured at the point of interest."
[The amendment to the definition of "Filling ratio" in the German version does not
apply to the English text.]
In the definition of "GHS", replace "seventh" by:
"eighth" and replace "ST/SG/AC.10/30/Rev.7" by:
"ST/SG/AC.10/30/Rev.8".
Amend the definition of "Manual of Tests and Criteria" as follows:
– Replace "sixth" by:
"seventh".
– Delete "United Nations Recommendations on the Transport of Dangerous
Goods,".
– Replace "ST/SG/AC.10/11/Rev.6 and Amend.1" by:
"ST/SG/AC.10/11/Rev.7".
Insert the following new definition for "IAEA Regulations for the Safe Transport of
Radioactive Material":
""IAEA Regulations for the Safe Transport of Radioactive Material" means one
of the editions of those Regulations, as follows:
(a) For the 1985 and 1985 (as amended 1990) editions: IAEA Safety Series No. 6;
(b) For the 1996 edition: IAEA Safety Series No. ST-1;
(c) For the 1996 (revised) edition: IAEA Safety Series No. TS-R-1 (ST-1, Revised);
(d) For the 1996 (as amended 2003), 2005 and 2009 editions: IAEA Safety Stand-
ards Series No. TS-R-1;
(e) For the 2012 edition: IAEA Safety Standards Series No. SSR-6;
(f) For the 2018 edition: IAEA Safety Standards Series No. SSR–6 (Rev.1)."
3
[OTIF/RID/CE/2020/1]
Replace the definition for "Operator of a tank-container, portable tank or tank-
wagon" by the following two definitions:
""Tank-container or portable tank operator" means any enterprise in whose name
the tank-container or portable tank is operated;".
""Tank-wagon operator"5 means any enterprise in whose name the tank-wagon is
registered or approved for transport;".
Amend footnote 5 to read as follows:
"5 The term "operator" is equivalent to the term "keeper" as defined in Article 2, n) of
Appendix G to COTIF (ATMF) and in Article 3.19 of Directive 2016/798/EU on rail-
way safety and Article 2.21 of Directive 2016/797/EU on the interoperability of the
rail system within the European Union."
Delete the definition of "Radiation level".
[The amendment to the definition of ""Reconditioned packaging"" in the German
version does not apply to the English text.]
[The amendments to the definition of ""Rigid inner receptacle" (for composite IBCs)"
in the German version do not apply to the English text.]
Amend the definition of "Self-accelerating decomposition temperature (SADT)"
to read as follows:
""Self-accelerating decomposition temperature (SADT)" means the lowest tem-
perature at which self-accelerating decomposition may occur in a substance in the
packaging, IBC or tank as offered for carriage. The SADT shall be determined in ac-
cordance with the test procedures given in Part II, Section 28 of the Manual of Tests
and Criteria;".
In the definition of "Self-accelerating polymerization temperature (SAPT)", in the
first sentence, between "which" and "polymerization", insert:
"self-accelerating".
In the definition of "Tank-wagon", replace "shells" by:
"tanks".
In the definition of "Transport index", in the first sentence, after "SCO-I", add:
"or SCO-III".
In the definition of "UN Model Regulations", replace "twentieth" by:
"twenty-first" and replace "(ST/SG/AC.10/1/Rev.20)" by:
"(ST/SG/AC.10/1/Rev.21)".
Chapter 1.4
1.4.1.1 [The amendment in the German version does not apply to the English text.]
1.4.3.3 Delete the Note in paragraph (a).
4
[OTIF/RID/CE/2020/1]
In paragraph (e), delete:
"maximum" (twice).
Delete the Note in paragraph (f).
At the end, amend the Note to read as follows:
"NOTE: The filler shall establish procedures to ensure that he fulfils all his obliga-
tions. Guidelines in the form of checklists for tank-wagons for liquids and
gases are available on the OTIF website (www.otif.org) to help the filler of
tank-wagons for liquids and gases fulfil his safety obligations, particularly
with respect to the leaktightness of tank-wagons."
1.4.3.7.1 Delete the Notes in paragraphs (b) and (d).
At the end, amend the Note to read as follows:
"NOTE: The unloader shall establish procedures to ensure that he fulfils all his ob-
ligations. Guidelines in the form of checklists for tank-wagons for liquids
and gases are available on the OTIF website (www.otif.org) to help the un-
loader of tank-wagons for liquids and gases fulfil his safety obligations, par-
ticularly with respect to the leaktightness of tank-wagons."
Chapter 1.6
1.6.1.1 Replace “30 June 2019” by:
“30 June 2021”.
Replace “31 December 2018” by:
“31 December 2020”.
In footnote 15, replace "1 January 2017" by:
"1 January 2019".
1.6.1.22 Amend to read as follows:
"1.6.1.22 (Deleted)".
1.6.1.30 Amend to read as follows:
"1.6.1.30 (Deleted)".
1.6.1.47 Amend to read as follows:
"1.6.1.47 (Deleted)".
1.6.2 Add the following new transitional provision:
"1.6.2.16 The requirements of Note 3 of 6.2.3.5.1 applicable until 31 December 2020 may con-
tinue to be applied until 31 December 2022."
5
[OTIF/RID/CE/2020/1]
1.6.3.3.2 Amend to read as follows:
"1.6.3.3.2 (Deleted)".
1.6.3.27 In paragraph (a), delete the last sub-paragraph.
1.6.4 Add the following new transitional provision:
"1.6.4.55 Fibre-reinforced plastics tank-containers constructed before 1 July 2021 in accord-
ance with the requirements in force up to 31 December 2020 but which do not, how-
ever, meet the requirements for the marking of the tank code of 6.9.6.1 applicable as
from 1 January 2021 may continue to be marked in accordance with the requirements
applicable up to 31 December 2020 until the next periodic inspection after 1 July
2021."
1.6.6.1 Amend to read as follows:
"1.6.6.1 Packages not requiring competent authority approval of design under the 1985,
1985 (as amended 1990), 1996, 1996 (revised), 1996 (as amended 2003), 2005,
2009 and 2012 editions of the IAEA Regulations for the Safe Transport of Radi-
oactive Material
Packages not requiring competent authority approval of design (excepted packages,
Type IP-1, Type IP-2, Type IP-3 and Type A packages) shall meet the requirements
of RID in full, except that:
(a) Packages that meet the requirements of the 1985 or 1985 (as amended 1990)
editions of the IAEA Regulations for the Safe Transport of Radioactive Material:
(i) May continue to be carried provided that they were prepared for carriage prior
to 31 December 2003 and are subject to the requirements of 1.6.6.2.3, if ap-
plicable; or
(ii) May continue to be used, provided that all the following conditions are met:
– They were not designed to contain uranium hexafluoride;
– The applicable requirements of 1.7.3 are applied;
– The activity limits and classification in 2.2.7 are applied;
– The requirements and controls for carriage in Parts 1, 3, 4, 5 and 7 are
applied; and
– The packaging was not manufactured or modified after 31 December
2003;
(b) Packages that meet the requirements of the 1996, 1996 (revised), 1996 (as
amended 2003), 2005, 2009 or 2012 editions of the IAEA Regulations for the
Safe Transport of Radioactive Material:
(i) May continue to be carried provided that they were prepared for carriage prior
to 31 December 2025 and are subject to the requirements of 1.6.6.2.3, if
applicable; or
(ii) May continue to be used, provided that all the following conditions are met:
– The applicable requirements of 1.7.3 are applied;
6
[OTIF/RID/CE/2020/1]
– The activity limits and classification in 2.2.7 are applied;
– The requirements and controls for carriage in Parts 1, 3, 4, 5 and 7 are
applied; and
– The packaging was not manufactured or modified after 31 December
2025."
1.6.6.2 Amend to read:
"1.6.6.2 Packages designs approved under the 1985, 1985 (as amended 1990), 1996,
1996 (revised), 1996 (as amended 2003), 2005, 2009 and 2012 editions of the
IAEA Regulations for the Safe Transport of Radioactive Material
1.6.6.2.1 Packages requiring competent authority approval of the design shall meet the require-
ments of RID in full except that:
(a) Packagings that were manufactured to a package design approved by the com-
petent authority under the provisions of the 1985 or 1985 (as amended 1990)
editions of the IAEA Regulations for the Safe Transport of Radioactive Material
may continue to be used provided that all of the following conditions are met:
(i) The package design is subject to multilateral approval;
(ii) The applicable requirements of 1.7.3 are applied;
(iii) The activity limits and classification in 2.2.7 are applied; and
(iv) The requirements and controls for carriage in Parts 1, 3, 4, 5 and 7 are ap-
plied;
(v) (Reserved);
(b) Packagings that were manufactured to a package design approved by the com-
petent authority under the provisions of the 1996, 1996 (revised), 1996 (as
amended 2003), 2005, 2009 or 2012 editions of the IAEA Regulations for the
Safe Transport of Radioactive Material may continue to be used provided that all
of the following conditions are met:
(i) The package design is subject to multilateral approval after 31 December
2025;
(ii) The applicable requirements of 1.7.3 are applied;
(iii) The activity limits and material restrictions of 2.2.7 are applied;
(iv) The requirements and controls for carriage in Parts 1, 3, 4, 5 and 7 are ap-
plied.
1.6.6.2.2 No new manufacture of packagings to a package design meeting the provisions of
the 1985 and 1985 (as amended 1990) editions of the IAEA Regulations for the Safe
Transport of Radioactive Material shall be permitted to commence.
1.6.6.2.3 No new manufacture of packagings of a package design meeting the provisions of
the 1996, 1996 (revised), 1996 (as amended 2003), 2005, 2009 or 2012 editions of
the IAEA Regulations for the Safe Transport of Radioactive Material shall be permitted
to commence after 31 December 2028."
7
[OTIF/RID/CE/2020/1]
1.6.6.3 Amend the title to read:
"Packages excepted from the requirements for fissile materials under the 2011
and 2013 editions of RID (2009 edition of the IAEA Regulations for the Safe
Transport of Radioactive Material)".
1.6.6.4 Amend to read as follows:
"1.6.6.4 Special form radioactive material approved under the 1985, 1985 (as amended
1990), 1996, 1996 (revised), 1996 (as amended 2003), 2005, 2009 and 2012 edi-
tions of the IAEA Regulations for the Safe Transport of Radioactive Material
Special form radioactive material manufactured to a design that had received unilat-
eral approval by the competent authority under the 1985, 1985 (as amended 1990),
1996, 1996 (revised), 1996 (as amended 2003), 2005, 2009 and 2012 editions of the
IAEA Regulations for the Safe Transport of Radioactive Material may continue to be
used when in compliance with the mandatory management system in accordance with
the applicable requirements of 1.7.3. There shall be no new manufacture of special
form radioactive material to a design that had received unilateral approval by the com-
petent authority under the 1985 or 1985 (as amended 1990) editions of the IAEA
Regulations for the Safe Transport of Radioactive Material. No new manufacture of
special form radioactive material to a design that had received unilateral approval by
the competent authority under the 1996, 1996 (revised), 1996 (as amended 2003),
2005, 2009 and 2012 editions of the IAEA Regulations for the Safe Transport of Ra-
dioactive Material shall be permitted to commence after 31 December 2025."
Chapter 1.7
1.7.1 Amend Note 1 as follows:
– In the first sentence, replace "In the event of accidents or incidents" by:
"In the event of a nuclear or radiological emergency".
– In the first sentence, replace ", emergency provisions, as established" by:
", provisions as established".
– Amend the second sentence to read as follows:
"This includes arrangements for preparedness and response established in ac-
cordance with the national and/or international requirements and in a consistent
and coordinated manner with the national and/or international emergency ar-
rangements."
Amend Note 2 to read as follows:
"2: The arrangements for preparedness and response shall be based on the graded
approach and take into consideration the identified hazards and their potential
consequences, including the formation of other dangerous substances that may
result from the reaction between the contents of a consignment and the environ-
ment in the event of a nuclear or radiological emergency. Guidance for the es-
tablishment of such arrangements is contained in "Preparedness and Response
for a Nuclear or Radiological Emergency", IAEA Safety Standards Series No.
GSR Part 7, IAEA, Vienna (2015); "Criteria for Use in Preparedness and Re-
sponse for a Nuclear or Radiological Emergency", IAEA Safety Standards Series
No. GSG-2, IAEA, Vienna (2011); "Arrangements for Preparedness for a Nuclear
8
[OTIF/RID/CE/2020/1]
or Radiological Emergency", IAEA Safety Standards Series No. GS-G-2.1, IAEA,
Vienna (2007), and "Arrangements for the Termination of a Nuclear or Radiolog-
ical Emergency", IAEA Safety Standards Series No. GSG-11, IAEA, Vienna
(2018)."
1.7.1.1 In the first sentence, replace "to persons" by:
"to people".
Amend the second and third sentences to read:
"These standards are based on the 2018 edition of the IAEA Regulations for the Safe
Transport of Radioactive Material, 2018 Edition", IAEA Safety Standards Series No.
SSR–6 (Rev.1), IAEA, Vienna (2018). Explanatory material can be found in "Advisory
Material for the IAEA Regulations for the Safe Transport of Radioactive Material (2018
Edition)", Safety Standard Series No. SSG-26 (Rev.1), IAEA, Vienna (2019)."
1.7.1.2 In the first sentence, replace "persons" by:
"people".
In the first sentence, replace "from the effects of radiation in the carriage" by:
"from harmful effects of ionizing radiation during the carriage".
In (b), replace "radiation levels" by:
"dose rate".
In the last sentence, replace "Finally" by:
"Thirdly".
Add the following new sentence at the end:
"Finally, further protection is provided by making arrangements for planning and pre-
paring emergency response to protect people, property and the environment."
1.7.1.5.1 In (a), after "5.2.1.10," add:
"5.4.1.2.5.1 (f) (i) and (ii), 5.4.1.2.5.1 (i),".
In (a), after "CW 33 (3.1),", add:
"(4.3),".
1.7.1.5.2 Delete the second sentence.
1.7.2.4 In the last sentence, replace "individual monitoring or work place monitoring" by:
"workplace monitoring or individual monitoring".
1.7.3.1 Delete the paragraph number.
1.7.4.2 In the second sentence, replace "through alternative means" by:
"through means alternative to the other provisions of RID,".
9
[OTIF/RID/CE/2020/1]
In the second sentence, replace "for single or a planned series of multiple consign-
ments" by:
"for a single consignment or a planned series of multiple consignments".
In the third sentence, at the end, after "applicable requirements", add:
"of RID".
1.7.6.1 In the introductory sentence, replace "radiation level" by:
"dose rate".
In (a), replace "consignor, consignee, carrier," by:
"consignor, carrier, consignee".
In (b), at the beginning, replace "carrier, consignor or consignee" by:
"consignor, carrier or consignee".
In (b) (iii), replace "similar circumstances" by:
"the causes and circumstances similar to those".
In (b) (iv), replace "on corrective or preventive actions" by:
"the corrective or preventive actions".
Chapter 1.8
1.8.5.1 After "carrier,", add:
"unloader,".
1.8.5.3 In the third paragraph (b) after "In occurrences involving radioactive material, the cri-
teria for loss of product are:", replace "(Schedule II of IAEA Safety Series No. 115 –
"International Basic Safety Standards for Protection against Ionizing Radiation and for
the safety of Radiation Sources")" by:
"("Radiation Protection and Safety of Radiation Sources: International Basic Safety
Standards", IAEA Safety Standards Series No. GSR Part 3, IAEA, Vienna (2014))".
1.8.6.4.1 Replace "EN ISO/IEC 17025:2005" by:
"EN ISO/IEC 17025:2017 (except clause 8.1.3)".
1.8.7.8 In the "References" column of the Table, amend "EN 12972:2007" to read:
"EN 12972:2018".
10
[OTIF/RID/CE/2020/1]
Chapter 1.10
1.10.3.1.2 Amend Table 1.10.3.1.2 as follows:
– For Class 1, Division 1.4, in column "Substance or article", replace "and 0500"
by:
", 0500, 0512 and 0513".
– Add the following new row after "Class 1, Division 1.5":
"
Class Divi- Substance or article Quantity
sion Tank Bulk (kg)(d) Packages
(l)(c) (kg)
(a) (a)
1 1.6 Explosives 0
"
– For Class 6.2, amend the text in column "Substance or article" to read:
"Infectious substances of Category A (UN Nos. 2814 and 2900, except for animal
material) and medical waste of Category A (UN No. 3549)".
1.10.4 Replace "and 0500 by:
", 0500, 0512 and 0513".
1.10.5 Replace "The Physical Protection of Nuclear Material and Nuclear Facilities" by:
"Nuclear Security Recommendations on Physical Protection of Nuclear Material and
Nuclear Facilities".
In footnote 22, replace "INFCIRC/225/Rev.4 (Corrected), IAEA, Vienna (1999)" by:
"INFCIRC/225/Rev.5, IAEA, Vienna (2011)".
PART 2
Chapter 2.1
2.1.3.4 Add the following new paragraph:
"2.1.3.4.3 Used articles, e.g. transformers and condensers, containing a solution or mixture
mentioned in 2.1.3.4.2 shall always be classified under the same entry of Class 9,
provided:
(a) they do not contain any additional dangerous components, other than polyhalo-
genated dibenzodioxins and dibenzofurans of Class 6.1 or components of pack-
ing group III of Class 3, 4.1, 4.2, 4.3, 5.1, 6.1 or 8; and
(b) they do not have the hazard characteristics as indicated in 2.1.3.5.3 (a) to (g) and
(i)."
2.1.3.8 In the second sentence, after "Other substances meeting the criteria of no other
class", add:
"or of no other substance of Class 9".
11
[OTIF/RID/CE/2020/1]
2.1.5 Amend the Note under the heading to read as follows:
"NOTE: For articles which do not have a proper shipping name and which contain
only dangerous goods within the permitted limited quantity amounts speci-
fied in Column (7a) of Table A of Chapter 3.2, UN No. 3363 and special
provisions 301 and 672 of Chapter 3.3 may be applied."
2.1.5.4 At the end, add the following new sentence:
"However, this section applies to articles containing explosives which are excluded
from Class 1 in accordance with 2.2.1.1.8.2."
2.1.5.5 [The amendment in the German version does not apply to the English text.]
Chapter 2.2
Section 2.2.1
2.2.1.1.1 [The amendment in the German version does not apply to the English text.]
2.2.1.1.3 [The amendment in the German version does not apply to the English text.]
2.2.1.1.7.2 In the first sentence, after "0336" insert:
", and assignment of articles to UN No. 0431 for those used for theatrical effects meet-
ing the definition for article type and the 1.4G specification in the default fireworks
classification table in 2.2.1.1.7.5,".
2.2.1.1.8.2 In paragraph (b), in the Note, delete:
", such as described in ISO 12097-3" and add the following new second sentence:
"One such method is described in ISO 14451-2 using a heating rate of 80 K/min."
2.2.1.4 [The amendment to the definition of the definition of "ARTICLES, EXPLOSIVE, EX-
TREMELY INSENSITIVE (ARTICLES, EEI): UN No. 0486" in the French and Ger-
mans version does not apply to the English text.]
In the definition of "ARTICLES, EXPLOSIVE, EXTREMELY INSENSITIVE (ARTI-
CLES, EEI): UN No. 0486", replace "Articles that contain only extremely insensitive
substances" by:
"Articles that predominantly contain extremely insensitive substances".
After the definition of "DETONATORS, ELECTRIC for blasting: UN Nos. 0030, 0255,
0456", add the following new definition:
"DETONATORS, ELECTRONIC programmable for blasting: UN Nos. 0511, 0512,
0513
Detonators with enhanced safety and security features, utilizing electronic compo-
nents to transmit a firing signal with validated commands and secure communications.
Detonators of this type cannot be initiated by other means."
Section 2.2.2
2.2.2.1.5 For "Flammable gases", in the sentence after (b), replace "ISO 10156:2010" by:
"ISO 10156:2017".
12
[OTIF/RID/CE/2020/1]
For "Oxidizing gases", in the second sentence, replace "ISO 10156:2010" by:
"ISO 10156:2017".
2.2.2.2.2 [The amendment in the German version does not apply to the English text.]
2.2.2.3 In the Table for "Liquefied gases", for classification code 2F, amend the name and
description of UN No. 1010 to read as follows:
"1010 BUTADIENES, STABILIZED or BUTADIENES AND HYDROCARBON MIX-
TURE, STABILIZED, containing more than 40% butadienes".
The Note remains unchanged.Delete the Note.
[The amendment to UN 1965, Note 1 in the German version does not apply to the
English text.]
In the Table for "Other articles containing gas under pressure", for classification code
6F, insert the following entry after UN No. 3150:
"3358 REFRIGERATING MACHINES containing flammable, non-toxic, liquefied
gas".
Section 2.2.41
2.2.41.1.4 Replace "Part III, sub-section 33.2.1" by:
"Part III, sub-section 33.2" (twice).
2.2.41.1.5 Replace "Part III, sub-section 33.2.1" by:
"Part III, sub-section 33.2".
2.2.41.1.6 Replace "Part III, Section 33.2.1" by:
"Part III, sub-section 33.2".
2.2.41.1.8 Replace "Part III, sub-section 33.2.1" by:
"Part III, sub-section 33.2".
2.2.41.1.10 Replace "aromatic sulphohydrazides" by:
"aromatic sulphonylhydrazides".
2.2.41.4 [The amendment in the German version does not apply to the English text.]
Section 2.2.42
2.2.42.1.4 Replace "Part III, Section 33.3" and "Part III, section 33.3" by:
"Part III, sub-section 33.4" (twice).
2.2.42.1.5 Replace "Part III, section 33.3" by:
"Part III, sub-section 33.4".
13
[OTIF/RID/CE/2020/1]
2.2.42.1.7 Replace "Part III, section 33.3" by:
"Part III, sub-section 33.4".
2.2.42.1.8 Replace "Part III, section 33.3" by:
"Part III, sub-section 33.4".
Section 2.2.43
2.2.43.1.4 Replace "Part III, Section 33.4" by:
"Part III, sub-section 33.5".
2.2.43.1.5 Replace "Part III, Section 33.4" by:
"Part III, sub-section 33.5".
2.2.43.1.7 Replace "Part III, Section 33.4" by:
"Part III, sub-section 33.5".
2.2.43.1.8 Replace "Part III, section 33.4" by:
"Part III, sub-section 33.5".
Section 2.2.52
2.2.52.1.7 [The amendment in the French and German versions does not apply to the English
text.]
2.2.52.4 In the Table, for "DI-(4-tert-BUTYLCYCLOHEXYL) PEROXYDICARBONATE", for
concentration "≤ 42 as a paste", in column "Number (generic entry)", replace "3116"
by:
"3118".
Section 2.2.61
2.2.61.1.1 [The amendment in the German version does not apply to the English text.]
2.2.61.1.3 [The amendment in the German version does not apply to the English text.]
2.2.61.1.6 [The amendment in the German version does not apply to the English text.]
2.2.61.1.7 [The amendment in the German version does not apply to the English text.]
2.2.61.1.9.3 [The amendment in the German version does not apply to the English text.]
2.2.61.1.9.4 [The amendment in the German version does not apply to the English text.]
2.2.61.1.9.5 [The amendment in the German version does not apply to the English text.]
Section 2.2.62
2.2.62.1.1 In the second third sentence, delete:
", rickettsia".
14
[OTIF/RID/CE/2020/1]
2.2.62.1.3 Amend the definition of "Medical or clinical wastes" to read as follows:
"Medical or clinical wastes" are wastes derived from the veterinary treatment of ani-
mals, the medical treatment of humans or from bio-research;".
2.2.62.1.4 Replace "or 3373" by:
", 3373 or 3549".
2.2.62.1.4.1 In Note 1, replace "proper shipping name" by:
"name" (twice).
In Note 3, delete:
", mycoplasmas, rickettsia".
[The second and third amendments to Note 3 in the German version do not apply to
the English text.]
2.2.62.1.4.2 In the Note, replace "proper shipping name" by:
"name".
2.2.62.1.5.9 In (a), in the parenthesis, replace "UN No. 3291" by:
"UN Nos. 3291 and 3549".
2.2.62.1.11.1 Amend the text before the Note to read as follows:
"2.2.62.1.11.1 Medical or clinical waste containing:
(a) Category A infectious substances shall be assigned to UN No. 2814, UN No.
2900 or UN No. 3549, as appropriate. Solid medical waste containing Category
A infectious substances generated from the medical treatment of humans or vet-
erinary treatment of animals may be assigned to UN No. 3549. The UN No. 3549
entry shall not be used for waste from bio-research or liquid waste;
(b) Category B infectious substances shall be assigned to UN No. 3291.
NOTE 1: The proper shipping name for UN No. 3549 is "MEDICAL WASTE, CATE-
GORY A, AFFECTING HUMANS, solid" or "MEDICAL WASTE, CATE-
GORY A, AFFECTING ANIMALS only, solid"."
Renumber existing Note as Note 2.
2.2.62.1.11.4 Amend to read as follows:
"2.2.62.1.11.4 (Deleted)".
2.2.62.3 In the list of collective entries, for I3, add the following new entries:
"3549 MEDICAL WASTE, CATEGORY A, AFFECTING HUMANS, solid or
3549 MEDICAL WASTE, CATEGORY A, AFFECTING ANIMALS only, solid".
15
[OTIF/RID/CE/2020/1]
Section 2.2.7
2.2.7.2.1.1 In Table 2.2.7.2.1.1, for UN No. 2913, in the second column, replace "SCO-I or SCO-
II" by:
"SCO-I, SCO-II or SCO-III".
In the Table, for UN No. 3325, in the second column, delete the comma before "(LSA-
III)".
2.2.7.2.2.1 In Table 2.2.7.2.2.1, add the following rows in proper order:
"
Radionuclide A1 A2 Activity con- Activity limit
(atomic num- (TBq) (TBq) centration for an exempt
ber) limit for ex- consignment
empt material (Bq)
(Bq/g)
Ba-135m 2 × 101 6 × 10-1 1 × 102 1 × 106
0 0 1
Ge-69 1 × 10 1 × 10 1 × 10 1 × 106
1 0 4
Ir-193m 4 × 10 4 × 10 1 × 10 1 × 107
Ni-57 6 × 10-1 6 × 10-1 1 × 101 1 × 106
0 0 1
Sr-83 1 × 10 1 × 10 1 × 10 1 × 106
-1 -1 1
Tb-149 8 × 10 8 × 10 1 × 10 1 × 106
Tb-161 3 × 101 7 × 10-1 1 × 103 1 × 106
"
[The amendment to table note (a) in the German version does not apply to the English
text.]
Amend table note (b) as follows:
– [The first amendment to table note (b) in the German version does not apply to
the English text.]
– At the end of the introductory sentence, add:
"(the activity to be taken into account is that of the parent nuclide only)".
– After "Th-nat" and "U-nat", insert a reference to footnote 6.
The footnote reads:
"6 In the case of Th-natural, the parent nuclide is Th-232, in the case of U-natural
the parent nuclide is U-238."
In table note (c), replace "radiation level" by:
"dose rate".
2.2.7.2.2.2 In paragraph (a), replace "the International Basic Safety Standards for Protection
against Ionizing Radiation and for the Safety of Radiation Sources, Safety Series
No.115, IAEA, Vienna (1996)" by:
""Radiation Protection and Safety of Radiation Sources: International Basic Safety
Standards", IAEA Safety Standards Series No. GSR Part 3, IAEA, Vienna (2014)".
16
[OTIF/RID/CE/2020/1]
In paragraph (b), at the end, replace "the International Basic Safety Standards for
Protection against Ionizing Radiation and for the Safety of Radiation Sources, Safety
Series No.115, IAEA, Vienna (1996)" by:
"GSR Part 3".
2.2.7.2.2.3 Replace "daughter nuclide" by:
"progeny nuclide" (twice).
At the end, replace "daughter nuclides" by:
"progeny nuclides".
2.2.7.2.3.1.2 In paragraph (c), delete:
"that meet the requirements of 2.2.7.2.3.1.3,".
In paragraph (c), delete sub-paragraph (ii) and renumber sub-paragraph (iii) as (ii).
2.2.7.2.3.1.3 Amend to read as follows:
"2.2.7.2.3.1.3 (Deleted)".
2.2.7.2.3.2 In the introductory sentence before paragraph (a), replace "two" by:
"three".
At the end of paragraph (b) (iii), replace the full stop by a semicolon.
Add the following new paragraph (c):
"(c) SCO-III: A large solid object which, because of its size, cannot be carried in a
type of package described in RID and for which:
(i) All openings are sealed to prevent release of radioactive material during con-
ditions defined in 4.1.9.2.4 (e);
(ii) The inside of the object is as dry as practicable;
(iii) The non-fixed contamination on the external surfaces does not exceed the
limits specified in 4.1.9.1.2; and
(iv) The non-fixed contamination plus the fixed contamination on the inaccessible
surface averaged over 300 cm2 does not exceed 8 × 105 Bq/cm2 for beta and
gamma emitters and low toxicity alpha emitters, or 8 × 104 Bq/cm2 for all
other alpha emitters."
2.2.7.2.3.3.5 In paragraph (b), after "a free drop of 1.4 kg", replace "through 1 m" by:
"from a height of 1 m".
In paragraph (c), after "a free vertical drop of 1.4 kg", replace "through 1 m" by:
"from a height of 1 m".
17
[OTIF/RID/CE/2020/1]
2.2.7.2.3.3.7 In paragraph (b), replace "with specimen" by:
"and the specimen".
In paragraph (e), replace "with the specimen" by:
"and the specimen".
2.2.7.2.3.3.8 In paragraph (a) (ii), replace "shall be heated" by:
"shall then be heated".
2.2.7.2.3.4.1 In paragraph (a), replace "radiation level" by:
"dose rate".
2.2.7.2.3.5 [The amendment to the first sub-paragraph in the German version does not apply to
the English text.]
In paragraph (e), replace "limits provided in" by:
"the requirements of".
2.2.7.2.3.6 At the beginning, replace "A fissile material" by:
"Fissile material".
2.2.7.2.4.1.2 Replace "radiation level" by:
"dose rate".
2.2.7.2.4.1.3 In paragraph (a), replace "radiation level" by:
"dose rate".
At the end of paragraph (c), delete:
"and".
At the end of paragraph (d), replace the full stop by a semicolon.
Add additional paragraphs (e) and (f) as follows:
"(e) (Reserved);
(f) If the package contains fissile material, one of the provisions of 2.2.7.2.3.5 (a) to
(f) applies."
2.2.7.2.4.1.4 At the end of paragraph (a), delete:
"and".
At the end of existing paragraph (b) (ii), replace "." by:
"; and".
18
[OTIF/RID/CE/2020/1]
Add additional paragraph (c):
"(c) If the package contains fissile material, one of the provisions of 2.2.7.2.3.5 (a) to
(f) applies."
2.2.7.2.4.1.7 At the end of paragraph (c) (ii), delete:
and".
At the end of paragraph (d), replace "." by:
"; and".
Add additional paragraph (e):
"(e) If the packaging has contained fissile material, one of the provisions of 2.2.7.2.3.5
(a) to (f) or one of the provisions for exclusion in 2.2.7.1.3 applies."
Section 2.2.8
2.2.8.1.1 [The amendment in the French version does not apply to the English text.]
2.2.8.1.5.2 [The amendment to the second sentence in the German version does not apply to the
English text.]
In the second sentence, replace "the assignment" by:
"classification".
In the second sentence, replace "OECD Test Guideline 4046 or 4357" by:
"OECD Test Guidelines6,7,8,9,10".
Renumber existing footnotes 6 and 7 to 7 and 8.
Delete the existing footnote 9 and renumber the current footnote 8 to 9.
Renumber existing footnote 8 to 10.
In footnote 910 (current footnote 8), between "Test" and "(TER)", insert:
"Method".
Insert a new footnote 8 as follows:
Amend footnote 9 to read as follows:
"98 OECD Guideline for the testing of chemicals No. 431 "In vitro skin corrosion: re-
constructed human epidermis (RHE) test method" 2016."
In the third sentence replace "OECD Test Guideline 4308 or 4319" by:
"OECD Test Guidelines6,7,8,9,10".
At the end of the paragraph, add the following new sentence:
"If the in vitro test results indicate that the substance or mixture is corrosive and not
assigned to packing group I, but the test method does not allow discrimination be-
tween packing groups II and III, it shall be considered to be packing group II."
19
[OTIF/RID/CE/2020/1]
2.2.8.1.6.2 [The amendment in the German version does not apply to the English text.]
2.2.8.1.6.3.3 [The amendment in the French and German version does not apply to the English
text.]At the end, add the following new sentence:
"For this calculation method, generic concentration limits apply where 1% is used in
the first step for the assessment of the packing group I substances, and where 5% is
used for the other steps respectively."
2.2.8.1.6.3.4 [The amendment in the French version does not apply to the English text.]Delete the
last sentence.
Section 2.2.9
2.2.9 Renumber existing footnotes 10 to 17 to footnotes 11 to 18.
2.2.9.1.7 [The amendment to paragraph (g) in the German version does not apply to the English
text.]
2.2.9.1.10.6 Replace ", not otherwise classified under RID" by:
"that do not meet the classification criteria of any other class or another substance
within Class 9".
2.2.9.1.11 [The amendment in the German version does not apply to the English text.]
2.2.9.1.14 In footnote 187 (current 17), remove:
"used as coolant".
2.2.9.3 For M11, "Other substances and articles presenting a danger during carriage…", be-
fore "3363 DANGEROUS GOODS IN MACHINERY", insert:
"3363 DANGEROUS GOODS IN ARTICLES or".
Chapter 2.3
2.3.2 In the heading, amend "Class 4.1" to read:
"Class 1 and Class 4.1".
2.3.2.1 Amend to read as follows:
"2.3.2.1 In order to determine the criteria of the nitrocellulose, the Bergmann-Junk test or the
methyl violet paper test in the Manual of Tests and Criteria Appendix 10 shall be per-
formed (see Chapter 3.3, special provisions 393 and 394). If there is doubt that the
ignition temperature of the nitrocellulose is considerably higher than 132 °C in the
case of the Bergmann-Junk test or higher than 134.5 °C in the case of the methyl
violet paper test, the ignition temperature test described in 2.3.2.5 should be carried
out before these tests are performed. If the ignition temperature of nitrocellulose mix-
tures is higher than 180 °C or the ignition temperature of plasticized nitrocellulose is
higher than 170 °C, the Bergmann-Junk test or the methyl violet paper test can be
carried out safely."
2.3.2.2 to
2.3.2.5 Delete.
2.3.2.6 becomes 2.3.2.2.
20
[OTIF/RID/CE/2020/1]
In the text, amend "2.3.2.9 and 2.3.2.10" to read:
"2.3.2.5".
2.3.2.7 becomes 2.3.2.3.
In the text, replace "Before being dried as prescribed in 2.3.2.6 above, substances
conforming to 2.3.2.2 shall" by:
"Before being dried as prescribed in 2.3.2.2 above, plasticized nitrocellulose shall".
2.3.2.8 becomes 2.3.2.4.
In the text, replace "Weakly nitrated nitrocellulose conforming to 2.3.2.1 shall first un-
dergo preliminary drying as prescribed in 2.3.2.7 above" by:
"Weakly nitrated nitrocellulose shall first undergo preliminary drying as prescribed in
2.3.2.3 above".
2.3.2.9 Delete.
2.3.2.10 becomes 2.3.2.5.
In the heading, delete "and 2.3.2.2".
2.3.3.2 Renumber footnote 18 to 19.
PART 3
Chapter 3.1
3.1.2.8.1 Add the following new paragraph 3.1.2.8.1.4:
"3.1.2.8.1.4 For UN Nos. 3077 and 3082 only, the technical name may be a name shown in capital
letters in column 2 of Table A of Chapter 3.2, provided that this name does not include
"N.O.S." and that special provision 274 is not assigned. The name which most appro-
priately describes the substance or mixture shall be used, e.g.:
UN 3082, ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
(PAINT)
UN 3082, ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (PER-
FUMERY PRODUCTS)."
21
[OTIF/RID/CE/2020/1]
Chapter 3.2
Table A
Add the following new entries in proper order:
Packaging Portable tanks RID Tanks Special provisions for
Limited and excepted quan-
and bulk con- carriage
Hazard identification No.
Name and description
tainers
Transport category
Classification code
Special provisions
(express parcels)
Packing group
Colis express
UN No.
Labels
Class
tities
packing pro-
Loading, un-
Mixed pack-
Special pro-
Special pro-
Instructions
Packing in-
loading and
Tank code
structions
ing provi-
Special
Packages
visions
visions
visions
sions
handling
Bulk
(1) (2) (3a) (3b) (4) (5) (6) (7a) (7b) (8) (9a) (9b) (10) (11) (12) (13) (15) (16) (17) (18) (19) (20)
0511 DETONATORS, ELECTRONIC 1 1.1B 1 0 E0 P131 MP23 1 W2 CW1 1.1B
programmable for blasting (+13)
0512 DETONATORS, ELECTRONIC 1 1.4B 1.4 0 E0 P131 MP23 2 W2 CW1 1.4B
programmable for blasting
0513 DETONATORS, ELECTRONIC 1 1.4S 1.4 347 0 E0 P131 MP23 4 W2 CW1 CE1 1.4S
programmable for blasting
3549 MEDICAL WASTE, CATEGORY 6.2 I3 6.2 395 0 E0 P622 MP2 0 W9 CW13 CE14 606
A, AFFECTING HUMANS, solid or LP622 CW18
MEDICAL WASTE, CATEGORY CW26
A, AFFECTING ANIMALS only, CW28
solid
22
[OTIF/RID/CE/2020/1]
Amend the following entries:
UN Col- Amendment
No. umn
0005 (8) After "P130", add:
"LP101".
0007 (8) After "P130", add:
"LP101".
0012 (8) After "P130", add:
"LP101".
0014 (8) After "P130", add:
"LP101".
0033 (8) After "P130", add:
"LP101".
0037 (8) After "P130", add:
"LP101".
0136 (8) After "P130", add:
"LP101".
0167 (8) After "P130", add:
"LP101".
0180 (8) After "P130", add:
"LP101".
0238 (8) After "P130", add:
"LP101".
0240 (8) After "P130", add:
"LP101".
0242 (8) After "P130", add:
"LP101".
0279 (8) After "P130", add:
"LP101".
0291 (8) After "P130", add:
"LP101".
0294 (8) After "P130", add:
"LP101".
0295 (8) After "P130", add:
"LP101".
0324 (8) After "P130", add:
"LP101".
0326 (8) After "P130", add:
"LP101".
0327 (8) After "P130", add:
"LP101".
0330 (8) After "P130", add:
"LP101".
0338 (8) After "P130", add:
"LP101".
0339 (8) After "P130", add:
"LP101".
0340 (6) Insert:
"393".
0341 (6) Insert:
"393".
0342 (6) Insert:
"393".
0343 (6) Insert:
"393".
23
[OTIF/RID/CE/2020/1]
UN Col- Amendment
No. umn
0348 (8) After "P130", add:
"LP101".
0369 (8) After "P130", add:
"LP101".
0371 (8) After "P130", add:
"LP101".
0413 (8) After "P130", add:
"LP101".
0414 (8) After "P130", add:
"LP101".
0417 (8) After "P130", add:
"LP101".
0426 (8) After "P130", add:
"LP101".
0427 (8) After "P130", add:
"LP101".
0453 (8) After "P130", add:
"LP101".
0457 (8) After "P130", add:
"LP101".
0458 (8) After "P130", add:
"LP101".
0459 (8) After "P130", add:
"LP101".
0460 (8) After "P130", add:
"LP101".
1002 (6) Replace Delete:
"660" by:.
Insert:
"392".
1006 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
1010 (2) Amend the name and description to read as follows:
"BUTADIENES, STABILIZED or BUTADIENES AND HYDRO-
CARBON MIXTURE, STABILIZED, containing more than 40%
butadienes".
1013 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
1046 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
1056 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
24
[OTIF/RID/CE/2020/1]
UN Col- Amendment
No. umn
1058 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
1065 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
1066 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
1080 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
1323 (2) [The amendment in the German version does not apply to the
English text.]
1458 (2) [The amendment in the German version does not apply to the
English text.]
1952 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
1956 (6) Delete:
"660".
Insert:
"392".Replace "660" by:
"392".
2036 (6) Replace "660" by:
"392".
2037 (6) After "303", insert:
(all en- "327".
tries) (8) After "P003", insert:
"LP200".
(9a) After "PP17", against "P003", insert:
"PP96".
Against "LP200", insert:
"L2".
2211 (6) Add:
"675".
2383 (6) Delete:
"386".
2522 (2) At the end, add:
", STABILIZED".
(6) Insert:
"386".
2555 (6) Before "541", insert:
"394".
25
[OTIF/RID/CE/2020/1]
UN Col- Amendment
No. umn
2556 (6) Before "541", insert:
"394".
2557 (6) Before "541", insert:
"394".
2683 (20) Replace "86" by:
"836".
2794 (8) Delete:
"P801a".
2795 (8) Delete:
"P801a".
2800 (8) Replace "P801a" by:
"P801".
2913 (2) Replace "(SCO-I or SCO-II)" by:
"(SCO-I, SCO-II or SCO-III)".
3028 (8) Delete:
"P801a".
3070 (6) Replace "660" by:
"392".
3091 (6) After "387", insert:
"390".
3163 (6) Replace "660" by:
"392".
3164 (9a) Insert:
"PP32".
3291 (4) Delete:
(both "II".
en-
tries)
3297 (6) Replace "660" by:
"392".
3298 (6) Replace "660" by:
"392".
3299 (6) Replace "660" by:
"392".
3314 (6) Add:
"675".
3325 (2) Before "(LSA-III)", delete the comma.
3363 (2) At the beginning, insert:
"DANGEROUS GOODS IN ARTICLES or".
3380 (6) Add:
"394".
3481 (6) After "387", insert:
"390".
3500 (9a) Insert:
"PP97".
3537 (6) Delete:
"667".
3538 (6) Delete:
"667".
3539 (6) Delete:
"667".
3540 (6) Delete:
"667".
26
[OTIF/RID/CE/2020/1]
UN Col- Amendment
No. umn
3541 (6) Delete:
"667".
3542 (6) Delete:
"667".
3543 (6) Delete:
"667".
3544 (6) Delete:
"667".
3545 (6) Delete:
"667".
3546 (6) Delete:
"667".
3547 (6) Delete:
"667".
3548 (6) Delete:
"667".
Table B
Amend the following entries:
Name and description UN Amendment
No.
BUTADIENES AND HYDROCAR- 1010 Amend the name and description in
BON MIXTURE, STABILIZED, hav- column "Name and description" to
ing a vapour pressure at 70 °C not read as follows:
exceeding 1.1 MPa (11 bar) and a "BUTADIENES, STABILIZED or BU-
density at 50 °C not lower than TADIENES AND HYDROCARBON
0.525 kg/l MIXTURE, STABILIZED, containing
more than 40% butadienes".
CHLORATE AND BORATE MIX- 1458 [The amendment in the German ver-
TURE sion does not apply to the English
text.]
FERROCERIUM 1323 [The amendment in the German ver-
sion does not apply to the English
text.]
2-DIMETHYLAMINOETHYL- 2522 At the end of the name in column
METHACRYLATE "Name and description", add:
", STABILIZED".
RADIOACTIVE MATERIAL, LOW 3325 In column "Name and description",
SPECIFIC ACTIVITY, (LSA-III), delete the comma before "(LSA-III)".
FISSILE
RADIOACTIVE MATERIAL, SUR- 2913 In column "Name and description",
FACE CONTAMINATED OB- replace "(SCO-I or SCO-II)" by:
JECTS (SCO-I or SCO-II), non fis- "(SCO-I, SCO-II or SCO-III)".
sile or fissile-excepted
TRINITROCHLOROBENZENE 3365 In column "Name and description",
WETTED with not less than 10% insert a comma before "WETTED".
water, by mass
TRINITROPHENOL WETTED with 3364 In column "Name and description",
not less than 10% water, by mass insert a comma before "WETTED".
27
[OTIF/RID/CE/2020/1]
Insert the following new entries in alphabetical order:
Name and description UN Note NHM
No. Code
DANGEROUS GOODS IN ARTICLES 3363 ??????
DETONATORS, ELECTRONIC programmable 0511 ??????
for blasting
DETONATORS, ELECTRONIC programmable 0512 ??????
for blasting
DETONATORS, ELECTRONIC programmable 0513 ??????
for blasting
MEDICAL WASTE, CATEGORY A, AFFECT- 3549 ??????
ING HUMANS, solid
MEDICAL WASTE, CATEGORY A, AFFECT- 3549 ??????
ING ANIMALS only, solid
Chapter 3.3
SP 169 [The amendment in the German version does not apply to the English text.]
SP 188 [The amendments to paragraphs (d) and (e) in the German version do not apply to
the English text.]
[The amendments to paragraphs (g) and (h) in the French version do not apply to the
English text.]
In paragraphs (g) and (h), replace "when batteries" by:
"when cells or batteries".
SP 237 Replace "sub-section 33.2.1" by:
"sub-section 33.2".
SP 241 Replace "sub-section 33.2.1.4" by:
"sub-section 33.2.4".
SP 249 [The amendment in the German version does not apply to the English text.]
SP 301 Amend the first sentence as follows:
– Replace "applies to machinery or apparatus" by:
"applies to articles such as machinery, apparatus or devices".
– Replace "machinery or apparatus" by:
"articles".
In the second sentence, replace "machinery or apparatus" by:
"articles".
In the third sentence, replace "Machinery and apparatus" by:
"Articles".
28
[OTIF/RID/CE/2020/1]
In the fourth sentence, replace "machinery or apparatus" by:
"articles".
In the fifth sentence, replace "machinery or apparatus contains" by:
"articles contain".
Delete the Note at the end.
SP 309 In the last paragraph, replace "satisfactorily pass Tests 8 (a), (b) and (c)" by:
"satisfy the criteria for classification as an ammonium nitrate emulsion, suspension or
gel, intermediate for blasting explosives (ANE)".
SP 327 In the first sentence, replace "Waste aerosols consigned" by:
"Waste aerosols and waste gas cartridges consigned".
In the first sentence, replace "carried under this entry for" by:
"carried under UN Nos. 1950 or 2037, as appropriate, for".
After the third sentence insert the following new sentence:
"Waste gas cartridges, other than those leaking or severely deformed, shall be packed
in accordance with packing instruction P 003 and special packing provisions PP 17
and PP 96, or packing instruction LP 200 and special packing provision L 2."
In the fifth sentence (current fourth sentence), replace "aerosols shall be carried in
salvage packagings" by:
"aerosols and gas cartridges shall be carried in salvage pressure receptacles or sal-
vage packagings".
In the Note replace "Waste aerosols shall not" by:
"Waste aerosols and waste gas cartridges shall not".
At the end, add the following new paragraph:
"Waste gas cartridges that were filled with non-flammable, non-toxic gases of Class
2, group A or O and have been pierced are not subject to RID."
SP 356 After "in wagons, vehicles, vessels" add:
", machinery, engines".
SP 360 Replace "classified under" by:
"assigned to".
29
[OTIF/RID/CE/2020/1]
At the end, add the following sentence:
"Lithium batteries installed in cargo transport units, designed only to provide power
external to the transport unit shall be assigned to entry UN 3536 LITHIUM BATTER-
IES INSTALLED IN CARGO TRANSPORT UNIT lithium ion batteries or lithium metal
batteries."
SP 370 Amend the first introductory sentence to read as follows:
"This entry only applies to ammonium nitrate that meets one of the following crite-
ria:"
Number the first indent as (a) and the second indent as (b).
At the end of (a) (current first indent), replace "and" by:
"or".
At the end, after the indentsparagraph (b), add the following new paragraph:
"This entry shall not be used for ammonium nitrate for which a proper shipping name
already exists in Table A of Chapter 3.2 including ammonium nitrate mixed with fuel
oil (ANFO) or any of the commercial grades of ammonium nitrate."
SP 376 Amend the Note to read as follows:
"NOTE: In assessing a cell or battery as damaged or defective, an assessment or
evaluation shall be performed based on safety criteria from the cell, battery
or product manufacturer or by a technical expert with knowledge of the cell’s
or battery’s safety features. An assessment or evaluation may include, but
is not limited to, the following criteria:
(a) Acute hazard, such as gas, fire, or electrolyte leaking;
(b) The use or misuse of the cell or battery;
(c) Signs of physical damage, such as deformation to cell or battery cas-
ing, or colours on the casing;
(d) External and internal short circuit protection, such as voltage or isola-
tion measures;
(e) The condition of the cell or battery safety features; or
(f) Damage to any internal safety components, such as the battery man-
agement system."
[The amendment to the last sentence in the German version does not apply to the
English text.]
SP 379 In (d) (i), replace "ISO 11114-1:2012" by:
"ISO 11114-1:2012 + A1:2017".
30
[OTIF/RID/CE/2020/1]
SP 388 At the end of the seventh paragraph, add the following sentence:
"Lithium ion batteries or lithium metal batteries installed in a cargo transport unit and
designed only to provide power external to the cargo transport unit shall be assigned
to the entry UN 3536 LITHIUM BATTERIES INSTALLED IN CARGO TRANSPORT
UNIT lithium ion batteries or lithium metal batteries."
SP 390 Amend to read as follows:
"390 When a package contains a combination of lithium batteries contained in equipment
and lithium batteries packed with equipment, the following requirements apply for the
purposes of package marking and documentation:
(a) the package shall be marked "UN 3091" or "UN 3481", as appropriate. If a pack-
age contains both lithium ion batteries and lithium metal batteries packed with
and contained in equipment, the package shall be marked as required for both
battery types. However, button cell batteries installed in equipment (including cir-
cuit boards) need not be considered;
(b) the transport document shall indicate "UN 3091 LITHIUM METAL BATTERIES
PACKED WITH EQUIPMENT" or "UN 3481 LITHIUM ION BATTERIES PACKED
WITH EQUIPMENT", as appropriate. If a package contains both lithium metal
batteries and lithium ion batteries packed with and contained in equipment, then
the transport document shall indicate both "UN 3091 LITHIUM METAL BATTER-
IES PACKED WITH EQUIPMENT" and "UN 3481 LITHIUM ION BATTERIES
PACKED WITH EQUIPMENT"."
SP 392 [The amendment in the German version does not apply to the English text.]
Replace
"393–
499" (Reserved)" by:
"396–
499 (Reserved)".
SP 556 Amend to read as follows:
"556 (Deleted)".
SP 594 [The amendments in the German version do not apply to the English text.]
SP 653 In the first indent, replace "for construction and testing" by:
"for construction, testing and filling".
SP 660 Amend to read as follows:
"660 (Deleted)".
SP 667 In paragraphs (a), (b) and (b) (ii), replace "engine, machinery or article" by:
"engine or machinery".
31
[OTIF/RID/CE/2020/1]
In paragraph (b) (i), replace "engines, machinery or article" by:
"engines or machinery".
In paragraph (c), replace "engines, machinery or articles" by:
"engines or machinery".
SP 671 At the end, add the following new paragraph:
"Kits containing only dangerous goods to which no packing group is assigned shall
be allocated to transport category 2 for completion of transport documents and the
exemption related to quantities carried per wagon or large container (see 1.1.3.6)."
Add the following new special provisions:
"393 The nitrocellulose shall meet the criteria of the Bergmann-Junk test or methyl violet
paper test in the Manual of Tests and Criteria Appendix 10. Tests of type 3 (c) need
not be applied.
394 The nitrocellulose shall meet the criteria of the Bergmann-Junk test or methyl violet
paper test in the Manual of Tests and Criteria Appendix 10.
395 This entry shall only be used for solid medical waste of Category A carried for dis-
posal."
"675 For packages containing these dangerous goods, mixed loading with substances and
articles of Class 1, with the exception of 1.4S, shall be prohibited."
Chapter 3.5
3.5.2 [The amendments in the German version do not apply to the English text.]
3.5.3.1 [The amendments in the German version do not apply to the English text.]
PART 4
Chapter 4.1
4.1.1 In the Note, replace "(Class 6.2)" by:
"(Class 6.2, UN Nos. 2814 and 2900)".
In the Note, amend the text in parentheses at the end of the sentence to read:
"(P 201, P 207 and LP 02 for Class 2 and P 620, P 621, P 622, IBC 620, LP 621 and
LP 622 for Class 6.2)".
4.1.1.1 [The amendment in the German version does not apply to the English text.]
4.1.1.3 becomes 4.1.1.3.1.
Delete the last sentence.
Add a new heading to read:
"4.1.1.3 Design type".
32
[OTIF/RID/CE/2020/1]
Add a new 4.1.1.3.2 to read as follows:
"4.1.1.3.2 Packagings, including IBCs and large packagings, may conform to one or more than
one successfully tested design type and may bear more than one mark."
4.1.1.5.1 [The amendment in the German version does not apply to the English text.]
4.1.1.10 [The amendments in the French version do not apply to the English text.]
4.1.1.21.6 In Table 4.1.1.21.6, for UN No. 1790, in column (2b), replace "hydrofluoric acid" by:
"hydrogen fluoride".
In Table 4.1.1.21.6, for UN No. 3291, in column (4), delete:
"II".
4.1.3.1 In the fourth sub-paragraph, in the row for "L", replace "specific to RID" by:
"specific to RID and ADR".
4.1.4.1
P 001 For "Single packagings/Composite packagings", in the last entry, replace "solid plas-
tics or expanded plastics" by:
"expanded plastics or solid plastics".
P 002 For "Single packagings/Composite packagings", in the last entry, replace "solid plas-
tics or expanded plastics packaging (6PH2 or 6PH1(e))" by:
"expanded plastics or solid plastics packaging (6PH1 or 6PH2(e))".
P 003 [The first amendment in the German version does not apply to the English text.]
For special packing provision PP 16, in Note 2, replace "P801a" by:
"P801".
For special packing provision PP 32, after "3358", add:
"and robust articles consigned under UN No. 3164".
Add the following new special packing provision:
"PP 96 For UN No. 2037 waste gas cartridges carried in accordance with special
provision 327 of Chapter 3.3, the packagings shall be adequately ventilated
to prevent the creation of dangerous atmospheres and the build-up of pres-
sure."
P 006 [The amendment in the German version does not apply to the English text.]
P 200 [The amendments in the French version do not apply to the English text.]
In (5) (a), after "special packing provision "o"", insert:
"of paragraph (10),".
33
[OTIF/RID/CE/2020/1]
In (5) (b), in the second sub-paragraph, after "special packing provision "o"", insert:
"of paragraph (10),".
In (5) (b) (i), after "special packing provision "r"", insert:
"of paragraph (10),".
In paragraph (11), amend the Table as follows:
– In the second row ("EN ISO 24431:2016"), in the column "Title of document",
replace "EN ISO" by:
"ISO".
– In the second row, in the column "Title of document", add the following Note:
"NOTE: The EN version of this ISO standard fulfils the requirements and may
also be used."
– Delete the fifth row ("ISO 24431:2006").
In paragraph (13) 2.4, replace "EN ISO 11114-1:2012 and EN 11114-2:2013" by:
"EN ISO 11114-1:2012 + A1:2017 and EN ISO 11114-2:2013".
In Table 2, replace the values of column "LC50 in ml/m3" as follows:
– For UN No. 1859, replace "450" by:
"922".
– For UN No. 2188, replace "20" by:
"178".
– For UN No. 2202, replace "2" by:
"51".
– For UN No. 2534, replace "600" by:
"2810".
– For UN No. 2676, replace "20" by:
"178".
P 206 In the title of the last row of the packing instruction, replace "Special packing provision"
by:
"Special packing provisions".
34
[OTIF/RID/CE/2020/1]
Add the following new special packing provision:
"PP 97 For fire extinguishing agents assigned to UN No. 3500 the maximum test
period for periodic inspection shall be 10 years. They may be carried in tubes
of a maximum water capacity of 450 litres conforming to the applicable re-
quirements of Chapter 6.2."
P 207 In special packing provision PP 87, replace "flammable atmosphere" by:
"dangerous atmospheres".
P 301 [The first amendment to paragraph (1) in the German version does not apply to the
English text.]
In the last sentence of paragraph (1), replace "unit" by:
"primary containment".
[The amendment to the penultimate sentence of paragraph (2) in the German ver-
sion does not apply to the English text.]
In the last sentence of paragraph (2), replace "unit" by:
"primary containment".
P 400 In paragraph (2), in the first sentence, delete:
"threaded".
In paragraph (2), after the first sentence, insert the following new sentence:
"Inner packagings shall have threaded closures or closures physically held in place
by any means capable of preventing back-off or loosening of the closure by impact
or vibration during carriage."
In paragraph (3), in the first sentence, delete:
"threaded".
In paragraph (3), after the first sentence, insert the following new sentence:
"Inner packagings shall have threaded closures or closures physically held in place
by any means capable of preventing back-off or loosening of the closure by impact
or vibration during carriage."
P 404 Amend paragraph (1), under "Inner packagings", as follows:
– In the first paragraph, delete:
"and have threaded closures".
– In the second paragraph, delete:
"threaded".
35
[OTIF/RID/CE/2020/1]
– Before the last sentence ("Outer packagings shall have a maximum net mass of
125 kg."), add the following new third paragraph:
"Inner packagings shall have threaded closures or closures physically held in
place by any means capable of preventing back-off or loosening of the closure
by impact or vibration during carriage."
In paragraph (2), between ", 1B1" and ", 1N1", insert:
", 1B2".
P 410 Amend table note d to read as follows:
"(d) For packing group II substances, these packagings may only be used when trans-
ported in a closed wagon or closed container."
In table note d, before "containers", delete:
"closed".
For "Single packagings/Composite packagings", in the last entry, replace "solid or
expanded plastics" by:
"expanded or solid plastics".
P 504 [The amendment in the French version does not apply to the English text.]
P 601 [The amendments in the German version do not apply to the English text.]
P 602 [The amendments in the German version do not apply to the English text.]
Insert the following new packing instruction:
"
P 622 PACKING INSTRUCTION P 622
This instruction applies to waste of UN No. 3549 carried for disposal.
The following packagings are authorized provided the general provisions of 4.1.1 and 4.1.3 are
met:
Inner packagings Intermediate packagings Outer packagings
metal metal Boxes
plastics plastics steel (4A)
aluminium (4B)
other metal (4N)
plywood (4D)
fibreboard (4G)
plastics, solid (4H2)
Drums
steel (1A2)
aluminium (1B2)
other metal (1N2)
plywood (1D)
fibre (1G)
plastics (1H2)
Jerricans
steel (3A2)
36
[OTIF/RID/CE/2020/1]
aluminium (3B2)
plastics (3H2)
The outer packaging shall conform to the packing group I performance level for solids.
Additional requirements:
1. Fragile articles shall be contained in either a rigid inner packaging or a rigid intermediate pack-
aging.
2. Inner packagings containing sharp objects such as broken glass and needles shall be rigid and
resistant to puncture.
3. The inner packaging, the intermediate packaging, and the outer packaging shall be capable of
retaining liquids. Outer packagings that are not capable of retaining liquids by design shall be
fitted with a liner or suitable measure of retaining liquids.
4. The inner packaging and/or the intermediate packaging may be flexible. When flexible packag-
ings are used, they shall be capable of passing the impact resistance test of at least 165 g
according to ISO 7765-1:1988 "Plastics film and sheeting – Determination of impact resistance
by the free-falling dart method – Part 1: Staircase methods" and the tear resistance test of at
least 480 g in both parallel and perpendicular planes with respect to the length of the bag in
accordance with ISO 6383-2:1983 "Plastics – Film and sheeting – Determination of tear re-
sistance – Part 2: Elmendorf method". The maximum net mass of each flexible inner packaging
shall be 30 kg.
5. Each flexible intermediate packaging shall contain only one inner packaging.
6. Inner packagings containing a small amount of free liquid may be included in intermediate pack-
aging provided that there is sufficient absorbent or solidifying material in the inner or intermedi-
ate packaging to absorb or solidify all the liquid content present. Suitable absorbent material
which withstands the temperatures and vibrations liable to occur under normal conditions of
carriage shall be used.
7. Intermediate packagings shall be secured in outer packagings with suitable cushioning and/or
absorbent material.
"
P 800 [The amendment in the German and French versions does not apply to the English
text.]
P 801 Amend to read as follows:
"
P 801 PACKING INSTRUCTION P 801
This instruction applies to UN Nos. 2794, 2795 and 3028 and used batteries of UN No. 2800.
The following packagings are authorized, provided that the provisions of 4.1.1.1, 4.1.1.2, 4.1.1.6
and 4.1.3 are met:
(1) Rigid outer packagings, wooden slatted crates or pallets.
Additionally, the following conditions shall be met:
(a) Battery stacks shall be in tiers separated by a layer of electrically non-conductive material;
(b) Battery terminals shall not support the weight of other superimposed elements;
(c) Batteries shall be packaged or secured to prevent inadvertent movement;
(d) Batteries shall not leak under normal conditions of carriage or appropriate measures shall
be taken to prevent the release of electrolyte from the package (e.g. individually packaging
batteries or other equally effective methods); and
37
[OTIF/RID/CE/2020/1]
(e) Batteries shall be protected against short circuits.
(2) Stainless steel or plastics bins may also be used to carry used batteries.
Additionally, the following conditions shall be met:
(a) The bins shall be resistant to the electrolyte that was contained in the batteries;
(b) The bins shall not be filled to a height greater than the height of their sides;
(c) The outside of the bins shall be free of residues of electrolyte contained in the batteries;
(d) Under normal conditions of carriage, no electrolyte shall leak from the bins;
(e) Measures shall be taken to ensure that filled bins cannot lose their content;
(f) Measures shall be taken to prevent short circuits (e.g. batteries are discharged, individual
protection of the battery terminals, etc.); and
(g) The bins shall be either:
(i) covered; or
(ii) carried in closed or sheeted wagons or in closed or sheeted containers.
"
P 801a Amend to read as follows:
"
P 801a PACKING INSTRUCTION P 801a
(Deleted)
"
"P 801a (Deleted)".
P 804 [The amendments in the German version do not apply to the English text.]
P 903 [The amendment to the last sub-paragraph of (4) in the German version does not
apply to the English text.]
Under paragraph (4), add the following Note:
"NOTE: For carriage in a transport chain including air carriage, these devices, when
active, shall meet defined standards for electromagnetic radiation to ensure
that the operation of the devices does not interfere with aircraft systems."
Add the following new paragraph (5):
"(5) For packagings containing both cells or batteries packed with equipment and con-
tained in equipment:
(a) For cells and batteries, packagings that completely enclose the cells or bat-
teries, then placed with equipment in a packaging conforming to the require-
ments in paragraph (1) of this packing instruction; or
(b) Packagings conforming to the requirements in paragraph (1) of this packing
instruction, then placed with the equipment in a strong outer packaging con-
structed of suitable material, and of adequate strength and design in relation
to the packaging capacity and its intended use. The outer packaging shall be
constructed in such a manner as to prevent accidental operation during car-
riage and need not meet the requirements of 4.1.1.3.
The equipment shall be secured against movement within the outer packaging.
38
[OTIF/RID/CE/2020/1]
Devices such as radio frequency identification (RFID) tags, watches and temper-
ature loggers, which are not capable of generating a dangerous evolution of heat,
may be carried when intentionally active in strong outer packagings.
NOTE: For carriage in a transport chain including air carriage, these devices,
when active, shall meet defined standards for electromagnetic radia-
tion to ensure that the operation of the devices does not interfere with
aircraft systems."
P 905 [The amendments in the German and French versions do not apply to the English
text.]
P 907 Amend the introductory first sentence to read:
"This instruction applies to articles, such as machinery, apparatus or devices of UN
No. 3363."
In the second sentence, replace "machinery or apparatus" by:
"article".
In the third sentence, replace "machinery or apparatus" by:
"an article".
In the fifth sixth sentence, replace "machinery or apparatus" by:
"article" (twice).
In the seventh sentence, replace "machinery or apparatus" by:
"article".
P 909 [The amendments in the German version do not apply to the English text.]
P 911 [The amendment in the German version does not apply to the English text.]
4.1.4.3
LP 01 In column "Large outer packagings", replace "Fibreboard (50G)" by:
"Rigid fibreboard (50G)".
LP 02 In column "Large outer packagings", replace "Fibreboard (50G)" by:
"Rigid fibreboard (50G)".
LP 101 In the heading of the third column, replace "Large packagings" by:
"Large outer packagings".
In the third column, replace "Fibreboard (50G)" by:
"Rigid fibreboard (50G)".
39
[OTIF/RID/CE/2020/1]
LP 102 In the heading of the third column, replace "Large packagings" by:
"Large outer packagings".
In the third column, replace "Fibreboard (50G)" by:
"Rigid fibreboard (50G)".
LP 200 In the introductory sentence, replace "UN No. 1950" by:
"UN Nos. 1950 and 2037".
In the second sentence, replace "are authorized for aerosols" by:
"are authorized for aerosols and gas cartridges".
In special packing provision L 2, in the first sentence, delete:
"of the aerosols".
In special packing provision L 2, amend the last sentence to read:
"For waste aerosols and waste gas cartridges carried in accordance with special pro-
vision 327, the large packagings shall be adequately ventilated to prevent the creation
of dangerous atmospheres and the build-up of pressure."
Insert the following new packing instruction:
"
LP 622 PACKING INSTRUCTION LP 622
This instruction applies to waste of UN No. 3549 carried for disposal.
The following large packagings are authorized provided the general provisions of 4.1.1 and 4.1.3
are met:
Inner packagings Intermediate packagings Outer packagings
metal metal steel (50A)
plastics plastics aluminium (50B)
metal other than steel or alu-
minium (50N)
plywood (50D)
rigid fibreboard (50G)
rigid plastics (50H)
The outer packaging shall conform to the packing group I performance level for solids.
Additional requirements:
1. Fragile articles shall be contained in either a rigid inner packaging or a rigid intermediate pack-
aging.
2. Inner packagings containing sharp objects such as broken glass and needles shall be rigid and
resistant to puncture.
3. The inner packaging, the intermediate packaging and the outer packaging shall be capable of
retaining liquids. Outer packagings that are not capable of retaining liquids by design shall be
fitted with a liner or suitable measure of retaining liquids.
40
[OTIF/RID/CE/2020/1]
4. The inner packaging and/or the intermediate packaging may be flexible. When flexible packag-
ings are used, they shall be capable of passing the impact resistance test of at least 165 g
according to ISO 7765-1:1988 "Plastics film and sheeting – Determination of impact resistance
by the free-falling dart method – Part 1: Staircase methods" and the tear resistance test of at
least 480 g in both parallel and perpendicular planes with respect to the length of the bag in
accordance with ISO 6383-2:1983 "Plastics – Film and sheeting – Determination of tear re-
sistance – Part 2: Elmendorf method". The maximum net mass of each flexible inner packaging
shall be 30 kg.
5. Each flexible intermediate packaging shall contain only one inner packaging.
6. Inner packagings containing a small amount of free liquid may be included in intermediate pack-
aging provided that there is sufficient absorbent or solidifying material in the inner or intermedi-
ate packaging to absorb or solidify all the liquid content present. Suitable absorbent material
which withstands the temperatures and vibrations liable to occur under normal conditions of
carriage shall be used.
7. Intermediate packagings shall be secured in outer packagings with suitable cushioning and/or
absorbent material.
"
LP 906 [The amendment in the German version does not apply to the English text.]
4.1.6.9 [The amendment in the German version does not apply to the English text.]
4.1.6.12 [The amendment in the French version does not apply to the English text.]
4.1.6.13 [The amendment in the French version does not apply to the English text.]
4.1.6.15 Amend the Table as follows:
– For "4.1.6.2", in the second column, replace "ISO 11114-2:2013" by:
"EN ISO 11114-2:2013".
– For "4.1.6.4", in the second column, replace "ISO 11621:1997" by:
"ISO 11621:1997 or EN ISO 11621:2005".
Delete the Note in the third column.
– For "4.1.6.8 Valves with inherent protection", in the first row, delete the Note in
the third column.
– For "4.1.6.8 Valves with inherent protection", in the third last row, second column,
replace "EN ISO 17879:2017" by:
"Annex A of EN ISO 17879:2017".
– For "4.1.6.8 (b) and (c)", replace "ISO 11117:1998 or ISO 11117:2008 +
Cor 1:2009" by:
"ISO 11117:1998 or EN ISO 11117:2008 + Cor 1:2009".
41
[OTIF/RID/CE/2020/1]
4.1.9.1.4 At the end, add the following new sentence:
"This requirement does not apply to the internal surfaces of containers being used as
packagings, either loaded or empty."
4.1.9.1.8 At the end of paragraph (d), replace the full stop by a semicolon.
Add the following paragraph (e):
"(e) For packages intended to be used for shipment after storage, it shall be ensured
that all packaging components and radioactive contents have been maintained
during storage in a manner such that all the requirements specified in the relevant
provisions of RID and in the applicable certificates of approval have been ful-
filled."
4.1.9.1.11 Replace "radiation level" by:
"dose rate".
4.1.9.1.12 Replace "radiation level" by:
"dose rate".
4.1.9.2.1 Replace "radiation level" by:
"dose rate".
4.1.9.2.4 In the introductory sentence, replace "and SCO-I" by:
", SCO-I and SCO-III".
At the end of (d), replace "." by:
"; and".
Add the following new paragraph (e):
"(e) For SCO-III:
(i) Carriage shall be under exclusive use;
(ii) Stacking shall not be permitted;
(iii) All activities associated with the shipment, including radiation protection,
emergency response and any special precautions or special administrative
or operational controls that are to be employed during carriage shall be de-
scribed in a transport plan. The transport plan shall demonstrate that the
overall level of safety in carriage is at least equivalent to that which would be
provided if the requirements of 6.4.7.14 (only for the test specified in 6.4.15.6,
preceded by the tests specified in 6.4.15.2 and 6.4.15.3) had been met;
(iv) The requirements of 6.4.5.1 and 6.4.5.2 for a Type IP-2 package shall be
satisfied, except that the maximum damage referred to in 6.4.15.4 may be
determined based on provisions in the transport plan, and the requirements
of 6.4.15.5 are not applicable;
42
[OTIF/RID/CE/2020/1]
(v) The object and any shielding are secured to the conveyance in accordance
with 6.4.2.1;
(vi) The shipment shall be subject to multilateral approval."
4.1.10.4
MP 12 In the penultimate sentence, replace "Packagings" by:
"Packages".
Chapter 4.2
4.2.1.13.8 [The amendment in the German version does not apply to the English text.]
4.2.3.7 Add the following new paragraph 4.2.3.7.3:
"4.2.3.7.3 The date at which the actual holding time ends shall be entered in the transport doc-
ument (see 5.4.1.2.2 (d))."
4.2.5.2.6 [The amendment in the French version does not apply to the English text.]
4.2.5.3 Amend special provision TP 19 to read as follows:
"TP19 At the time of construction, the minimum shell thickness determined according to
6.7.3.4 shall be increased by 3 mm as a corrosion allowance. Shell thickness shall be
verified ultrasonically at intervals midway between periodic hydraulic tests and shall
never be lower than the minimum shell thickness determined according to 6.7.3.4."
Chapter 4.3
4.3.4.1.3 In the Table, for "Class 8", "UN No. 1790", in column "Name and description", replace
"hydrofluoric acid" by:
"hydrogen fluoride".
4.3.4.2.2 Replace "shells" by:
"tanks".
4.3.4.2.3 In the first sentence, replace "shells" by:
"tanks".
PART 5
Chapter 5.1
5.1.2.2 [The amendment in the German version does not apply to the English text.]
5.1.5.1.2 At the end of paragraph (c), add:
"and".
Add additional paragraphs (d) and (e):
"(d) (Reserved)
43
[OTIF/RID/CE/2020/1]
(e) the shipment of SCO-III."
5.1.5.1.3 [The amendments in the German version do not apply to the English text.]
5.1.5.1.4 In paragraph (b), at the endin the last sentence, replace "in the hands" by:
"in the possession".
5.1.5.3.1 In the introductory sentence, replace "or SCO-I" by:
", SCO-I or SCO-III".
In paragraph (a), replace "radiation level" by:
"dose rate" (twice).
In paragraph (a), in the first sentence, replace "and SCO-I" by:
", SCO-I or SCO-III".
In paragraph (a), in the second sentence, delete:
"and the resulting number is the transport index".
[The amendment to the third sentence of paragraph (a) in the French version do not
apply to the English text.]
In paragraph (b), replace "and SCO-I" by:
", SCO-I and SCO-III".
At the end of paragraph (c), add:
"and the resulting number is the TI value".
In the title of Table 5.1.5.3.1, replace "and SCO-I" by:
", SCO-I and SCO-III".
5.1.5.3.2 Amend to read as follows:
"5.1.5.3.2 The TI for each rigid overpack, container or wagon shall be determined as the sum of
the TIs of all the packages contained therein. For a shipment from a single consignor,
the consignor may determine the TI by direct measurement of dose rate.
The TI for a non-rigid overpack shall be determined only as the sum of the TIs of all
the packages within the overpack."
5.1.5.3.4 In paragraph (a), replace "radiation level" by:
"dose rate" (twice).
In paragraph (b), replace "transport index" by:
"TI".
44
[OTIF/RID/CE/2020/1]
In paragraph (c), replace "radiation level" by:
"dose rate".
In Table 5.1.5.3.4, replace "radiation level" by:
"dose rate".
Chapter 5.2
5.2.1.1 Amend the end of the second sentence to read as follows:
"… for cylinders of 60 litres water capacity or less when they shall be at least 6 mm in
height and except for packages of 5 litres capacity or less or of 5 kg maximum net
mass when they shall be of an appropriate size."
5.2.1.7.6 Add the following sentence at the end sub-paragraph after the figure and the expla-
nation to the figure:
"Any mark on the package made in accordance with the requirements of 5.2.1.7.4 (a)
and (b) and 5.2.1.7.5 (c) relating to the package type that does not relate to the UN
number and proper shipping name assigned to the consignment shall be removed or
covered."
5.2.1.9.1 After "special provision 188", insert:
"of Chapter 3.3".
5.2.1.9.2 In Figure 5.2.1.9.2, replace "120 mm" by:
"100 mm" and "110 mm" by:
"100 mm".
Amend the last sub-paragraph as follows:
– In the first sentence, replace "a rectangle" by:
"a rectangle or a square".
– In the second sentence, replace "120 mm wide 110 mm high" by:
"100 mm wide 100 mm high".
– In the fifth sentence, delete:
"/line thickness".
– In the fifth sentence, replace "105 mm wide 74 mm high" by:
"100 mm wide 70 mm high".
5.2.2.1.11.2 In paragraph (d), replace "(no transport index entry is required for category I-WHITE)"
by:
"(except for category I-WHITE)".
45
[OTIF/RID/CE/2020/1]
Chapter 5.3
5.3.1.7.2 [The amendment in the German version does not apply to the English text.]
5.3.2.3.2 After the entry for "X83", insert the following new entry:
"836 Corrosive or slightly corrosive substance, flammable (flash-point between 23 °C
and 60 °C, inclusive) and toxic".
Chapter 5.4
5.4.1.1.1 [The amendment to paragraph (f) in the French version does not apply to the English
text.]
5.4.1.1.12 Replace "1 JANUARY 2019" by:
"1 JANUARY 2021".
5.4.1.2.2 In (d), replace "tank-wagons and tank-containers" by:
"tank-wagons, tank-containers or portable tanks".
5.4.1.2.5.1 Amend paragraphs (d) and (e) to read:
"(d) The category of the package, overpack or container, as assigned per 5.1.5.3.4,
i.e. I-WHITE, II-YELLOW, III-YELLOW;
(e) The TI as determined per 5.1.5.3.1 and 5.1.5.3.2 (except for category I-WHITE);".
In paragraph (j), replace "SCO-I and SCO-II" by:
"SCO-I, SCO-II and SCO-III".
5.4.2 In the second paragraph, at the end of the first sentence, delete:
"one to the other".
In footnote 10, replace "(Amendment 38-16)" by:
"(Amendment 39-18)".
Chapter 5.5
5.5.3 In the heading, after "applicable to", add:
"the carriage of dry ice (UN 1845) and to".
At the end of the heading, in the text in parentheses, after "(UN 1951)", add:
"or nitrogen".
After the heading, add the following new Note:
"NOTE: In the context of this section the term "conditioning" may be used in a
broader scope and includes protection."
46
[OTIF/RID/CE/2020/1]
5.5.3.2.1 After "containers", add:
"in which dry ice (UN 1845) is carried or".
5.5.3.2.4 After "containers", add:
"in which dry ice (UN 1845) is carried or".
5.5.3.3 After "Packages containing", add:
"dry ice (UN 1845) or".
5.5.3.3.3 In the first sentence, after "Packages containing", add:
"dry ice (UN 1845) or".
5.5.3.4 After "Packages containing", add:
"dry ice (UN 1845) or".
5.5.3.4.1 At the beginning of the first sentence, replace "Packages" by:
"Packages containing dry ice (UN 1845) as a consignment shall be marked "CARBON
DIOXIDE, SOLID" or "DRY ICE"; packages".
5.5.3.6.1 After "containers containing", add:
"dry ice (UN 1845) or".
In paragraph (a), after "harmful concentrations of", add:
"dry ice (UN 1845) or".
In paragraph (b), replace "The cooled" by:
"The dry ice (UN 1845) or cooled".
5.5.3.6.2 Amend Figure 5.5.3.6.2 as follows:
– Amend the name of the warning mark to read:
"Asphyxiation warning mark for wagons and containers".
– Delete the reference to note ** and the corresponding note.
– In note *, at the beginning, replace "of the coolant/conditioner" by:
"or the name of the asphyxiant gas used as the coolant/conditioner".
– At the end of note *, add:
"Additional information such as "AS COOLANT" or "AS CONDITIONER" may be
added."
5.5.3.7.1 After "having contained", add:
"dry ice (UN 1845) or".
47
[OTIF/RID/CE/2020/1]
In paragraph (b), after "Chapter 3.2 followed", add:
", where appropriate,".
In paragraph (b), after ""AS CONDITIONER"", delete:
"as appropriate".
5.5 Add a new section 5.5.4 to read as follows:
"5.5.4 Dangerous goods contained in equipment in use or intended for use during
carriage, attached to or placed in packages, overpacks, containers or load com-
partments
5.5.4.1 Dangerous goods (e.g. lithium batteries, fuel cell cartridges) contained in equipment
such as data loggers and cargo tracking devices, attached to or placed in packages,
overpacks, containers or load compartments are not subject to any provisions of RID
other than the following:
(a) the equipment shall be in use or intended for use during carriage;
(b) the contained dangerous goods (e.g. lithium batteries, fuel cell cartridges) shall
meet the applicable construction and test requirements specified in RID; and
(c) the equipment shall be capable of withstanding the shocks and loadings normally
encountered during carriage.
5.5.4.2 When such equipment containing dangerous goods is carried as a consignment, the
relevant entry of Table A of Chapter 3.2 shall be used and all applicable provisions of
RID shall apply.”
PART 6
In the heading, at the end, replace "and tanks" by:
", tanks and bulk containers".
Chapter 6.1
6.1.1.1 In paragraph (b), replace "packing instruction P 621" by:
"packing instructions P 621 and P 622".
6.1.3 [The amendment in the German version does not apply to the English text.]
6.1.3.1 Amend the third sentence to read as follows:
"Letters, numerals and symbols shall be at least 12 mm high, except for packagings
of 30 litres capacity or less or of 30 kg maximum net mass, when they shall be at least
6 mm in height and except for packagings of 5 litres capacity or less or of 5 kg maxi-
mum net mass when they shall be of an appropriate size."
48
[OTIF/RID/CE/2020/1]
In paragraph (e), in the text of the note explaining the asterisk, after the clock, replace
the second sentence by the following two sentences:
"In such a case and when the clock is placed adjacent to the UN design type approval
mark, the indication of the year in the mark may be waived. However, when the clock
is not placed adjacent to the UN design type approval mark, the two digits of the year
in the mark and in the clock shall be identical."
6.1.3 Add the following new 6.1.3.14:
"6.1.3.14 Where a packaging conforms to one or more than one tested packaging design type,
including one or more than one tested IBC or large packaging design type, the pack-
aging may bear more than one type approval mark to indicate the relevant perfor-
mance test requirements that have been met. Where more than one mark appears on
a packaging, the marks shall appear in close proximity to one another and each mark
shall appear in its entirety."
Renumber current 6.1.3.14 as 6.1.3.15.
6.1.4.2.2 [The amendment in the German version does not apply to the English text.]
6.1.4.2 Add the following new 6.1.4.2.6:
"6.1.4.2.6 If materials used for body, heads, closures and fittings are not in themselves compat-
ible with the contents to be carried, suitable internal protective coatings or treatments
shall be applied. These coatings or treatments shall retain their protective properties
under normal conditions of carriage."
Renumber the existing 6.1.4.2.6 and 6.1.4.2.7 as 6.1.4.2.7 and 6.1.4.2.8.
6.1.4.3.2 [The amendment in the German version does not apply to the English text.]
6.1.4.3 Add the following new 6.1.4.3.6:
"6.1.4.3.6 If materials used for body, heads, closures and fittings are not in themselves compat-
ible with the contents to be carried, suitable internal protective coatings or treatments
shall be applied. These coatings or treatments shall retain their protective properties
under normal conditions of carriage."
Renumber the existing 6.1.4.3.6 and 6.1.4.3.7 as 6.1.4.3.7 and 6.1.4.3.8.
6.1.4.4.2 [The amendments in the German version do not apply to the English text.]
6.1.4.9.2 [The amendment in the German version does not apply to the English text.]
6.1.4.15.3 [The amendment in the German version does not apply to the English text.]
6.1.4.16.1 [The amendment in the German version does not apply to the English text.]
6.1.4.16.4 [The amendment in the German version does not apply to the English text.]
6.1.4.18.2 [The amendment in the French and German version does not apply to the English
text.]
6.1.5.1.5 [The amendment in the German version does not apply to the English text.]
6.1.5.1.7 [The amendment in the German version does not apply to the English text.]
49
[OTIF/RID/CE/2020/1]
6.1.5.1.11 [The amendment in the German version does not apply to the English text.]
6.1.5.2.1 [The amendment in the German version does not apply to the English text.]
6.1.5.2.3 [The amendment in the German version does not apply to the English text.]
6.1.5.3.1 [The amendments in the German version do not apply to the English text.]
6.1.5.8.1 [The amendment in the German version does not apply to the English text.]
Chapter 6.2
6.2.1.3.6.4.1 [The amendment in the German version does not apply to the English text.]
6.2.1.6.1 [The amendment in the German version does not apply to the English text.]
6.2.2.1.1 Amend the Table as follows:
– In rows for "ISO 11119-3:2002" and "ISO 11119-3:2013" add the following new
Note in the second column:
"NOTE: This standard shall not be used for linerless cylinders manufactured
from two parts joined together."
– After "ISO 11119-3:2013", add the following new row:
"
Reference Title Applicable for
manufacture
Gas cylinders – Refillable composite gas cylin-
ders – Design, construction and testing – Part 4:
ISO 11119- Until further
Fully wrapped fibre reinforced composite gas
4:2016 notice
cylinders up to 150 l with load-sharing welded
metallic liners
"
6.2.2.1.2 In the Table, in the row containing "ISO 11119-3:2013", add the following new Note
in the second column:
"NOTE: This standard shall not be used for linerless tubes manufactured from two
parts joined together."
6.2.2.1.3 In the first Table ("For the cylinder shell"), add the following two new rows at the end:
"
Reference Title Applicable for
manufacture
ISO Gas cylinders – Refillable welded steel cylinders Until further
4706:2008 – Test pressure 60 bar and below notice
Gas cylinders – Refillable seamless aluminium
ISO alloy gas cylinders – Design, construction and
Until further
7866:2012 + testing
notice
Cor 1:2014 NOTE: Aluminium alloy 6351A or equivalent
shall not be used.
"
Amend the headline of the second Table to read as follows:
"For the acetylene cylinder including the porous material:".
50
[OTIF/RID/CE/2020/1]
6.2.2.2 In the Table, replace "ISO 11114-1:2012" by:
"ISO 11114-1:2012 + A1:2017".
6.2.2.3 Amend the first Table as follows:
– For "ISO 10297:2014", in the column "Applicable for manufacture", replace "Until
further notice" by:
"Until 31 December 2022".
– After the row for "ISO 10297:2014", insert the following new row:
"
Reference Title Applicable for
manufacture
ISO 10297:2014 + Gas cylinders – Cylinder valves – Specifi- Until further
A1:2017 cation and type testing notice
"
– For "ISO 14246:2014", in the column "Applicable for manufacture", replace "Until
further notice" by:
"Until 31 December 2024".
– After the row for "ISO 14246:2014", insert the following new row:
"
Reference Title Applicable for
manufacture
ISO 14246:2014 + Gas cylinders – Cylinder valves – Manufac- Until further
A1:2017 turing tests and examinations notice
"
– At the end, add the following new row:
Reference Title Applicable for
manufacture
ISO 17879:2017 Gas cylinders – Self-closing cylinder valves Until further
– Specification and type testing notice
NOTE: This standard shall not be applied to
self-closing valves in acetylene cyl-
inders.
"
6.2.2.4 Amend the first Table as follows:
– Delete the row for "ISO 10462:2005".
– Add the end, after the row for "ISO 22434:2006", add the following new row:
"
Reference Title Applicable for
manufacture
ISO 20475:2018 Gas cylinders – Cylinder bundles – Peri- Until further
odic inspection and testing notice
"
6.2.2.5.3.1 [The amendment in the German version does not apply to the English text.]
6.2.2.5.4.8 [The amendment in the German version does not apply to the English text.]
6.2.2.5.4.10 [The amendments in the German version do not apply to the English text.]
51
[OTIF/RID/CE/2020/1]
6.2.2.7.2 In paragraph (c), amend the Note to read:
"NOTE: For the purpose of this mark the country of approval means the country of
the competent authority that authorized the initial inspection and test of the
individual receptacle at the time of manufacture."
6.2.2.7.4 In paragraph (p), replace "ISO 11114-1:2012" by:
"ISO 11114-1:2012 + A1:2017".
6.2.2.9.2 In paragraph (c), amend the Note to read:
"NOTE: For the purpose of this mark the country of approval means the country of
the competent authority that authorized the initial inspection and test of the
individual system at the time of manufacture."
In paragraph (j), replace "ISO 11114-1:2012" by:
"ISO 11114-1:2012 + A1:2017".
6.2.2.10.2 [The amendment in the French version does not apply to the English text.]
6.2.2.11 After the Table, add insert the following sentence sub-paragraph:
"For refillable pressure receptacles, the conformity assessment of valves and other
demountable accessories having a direct safety function may be carried out sepa-
rately from that of the pressure receptacles."
6.2.3.5.1 Amend Note 3 to read as follows:
"3: The check of 6.2.1.6.1 (b) and the hydraulic pressure test of 6.2.1.6.1 (d) may be
replaced by ultrasonic examination carried out in accordance with
EN ISO 18119:2018 for cylinders and tubes of seamless steel or seamless alu-
minium alloy. Notwithstanding clause B.1 of this standard, all cylinders and tubes
whose wall thickness is less than the minimum design wall thickness shall be
rejected."
6.2.4.1 Amend the Table, under "for design and construction" as follows:
– For "Annex I, Parts 1 to 3 to 84/525/EEC", "Annex I, Parts 1 to 3 to 84/526/EEC"
and "Annex I, Parts 1 to 3 84/527/EEC", in column (2), insert the following Note:
"NOTE: Notwithstanding the repeal of the directives 84/525/EEC, 84/526/EEC
and 84/527/EEC as published in the Official Journal of the European
Communities No. L 300 of 19 November1984 the annexes of these di-
rectives remain applicable as standards for design, construction and
initial inspection and test for gas cylinders. These annexes may be
found at: https://eur-lex.europa.eu/oj/direct-access.html."
– For "EN 12807:2008", in column (4), replace "Until further notice" by:
"Between 1 January 2009 and 31 December 2022".
52
[OTIF/RID/CE/2020/1]
– After the row for "EN 12807:2008", insert the following new row:
"
(1) (2) (3) (4) (5)
LPG equipment and accessories –
6.2.3.1 Until fur-
Transportable refillable brazed steel
EN 12807:2019 and ther no-
cylinders for liquefied petroleum gas
6.2.3.4 tice
(LPG) – Design and construction
"
– For "EN ISO 9809-1:2010", in column (4), replace "Until further notice" by:
"Between 1 January 2013 and 31 December 2022".
– After the row for "EN ISO 9809-1:2010", insert the following new row:
"
(1) (2) (3) (4) (5)
Gas cylinders – Design, construction
and testing of refillable seamless steel
6.2.3.1 Until fur-
EN ISO 9809- gas cylinders and tubes – Part 1:
and ther no-
1:2019 Quenched and tempered steel cylinders
6.2.3.4 tice
and tubes with tensile strength less than
1100 MPa
"
– For "EN ISO 9809-2:2010", in column (4), replace "Until further notice" by:
"Between 1 January 2013 and 31 December 2022".
– After the row for "EN ISO 9809-2:2010", insert the following new row:
"
(1) (2) (3) (4) (5)
Gas cylinders – Design, construction
and testing of refillable seamless steel
6.2.3.1 Until fur-
EN ISO 9809- gas cylinders and tubes – Part 2:
and ther no-
2:2019 Quenched and tempered steel cylinders
6.2.3.4 tice
and tubes with tensile strength greater
than or equal to 1100 MPa
"
– For "EN ISO 9809-3:2010", in column (4), replace "Until further notice" by:
"Between 1 January 2013 and 31 December 2022".
– After the row for "EN ISO 9809-3:2010", insert the following new row:
"
(1) (2) (3) (4) (5)
Gas cylinders – Design, construction
6.2.3.1 Until fur-
EN ISO 9809- and testing of refillable seamless steel
and ther no-
3:2019 gas cylinders and tubes – Part 3: Nor-
6.2.3.4 tice
malized steel cylinders and tubes
"
– [The amendment to "EN 12245:2002" in the German version does not apply to
the English text.]
– [The amendment to "EN 12245:2009 + A1:2011" in the German version does not
apply to the English text.]
Amend the Table, under "for closures", as follows:
– For "EN ISO 17871:2015", in column (4), replace "Until further notice" by:
"Between 1 January 2017 and 31 December 2021".
53
[OTIF/RID/CE/2020/1]
– After the row for "EN ISO 17871:2015", insert following new row:
"
(1) (2) (3) (4) (5)
6.2.3.1,
Gas cylinders – Quick-release cylin- Until fur-
EN ISO 17871:2015 + 6.2.3.3
der valves – Specification and type ther no-
A1:2018 and
testing tice
6.2.3.4
"
6.2.4.2 Amend the Table as follows:
– For "EN 1968:2002 +A1:2005 (except annex B)", in column (3), replace "Until
further notice" by:
"Until 31 December 2022".
– For "EN 1802:2002 (except annex B)", in column (3), replace "Until further notice"
by:
"Until 31 December 2022".
– After the row for "EN 1802:2002 (except annex B)", insert the following new row:
"
(1) (2) (3)
Gas cylinders – Seamless steel and seamless aluminium-
alloy gas cylinders and tubes – Periodic inspection and test-
ing
EN ISO Mandatorily from
NOTE: Notwithstanding clause B.1 of this standard, all cyl-
18119:2018 1 January 2023
inders and tubes whose wall thickness is less than
the minimum design wall thickness shall be re-
jected.
"
– For "EN ISO 10462:2013", in column (3), replace "Until further notice" by:
"Until 31 December 2022".
– After the row for "EN ISO 10462:2013", insert the following new row:
"
(1) (2) (3)
EN ISO Gas cylinders – Acetylene cylinders – Periodic inspection
Mandatorily from
10462:2013 + and maintenance – Amendment 1 (ISO 10462:2013 +
1 January 2023
A1:2019 A1:2019)
"
– For "EN 1803:2002 (except Annex B)", in column (3), replace "Until further notice"
by:
"Until 31 December 2022".
– After the row for "EN 1803:2002 (except Annex B)", insert the following new row:
"
(1) (2) (3)
EN ISO Gas cylinders – Welded aluminium-alloy, carbon and stain- Mandatorily from
10460:2018 less steel gas cylinders – Periodic inspection and testing 1 January 2023
"
– For "EN 1440:2016 (except annex C)", in column (3), replace "Until further notice"
by:
"Until 31 December 2021".
54
[OTIF/RID/CE/2020/1]
– After the row for "EN 1440:2016 (except annex C)", insert the following new row:
"
(1) (2) (3)
EN 1440:2016 + LPG equipment and accessories – Transportable refillable Mandatorily
A1:2018 (except traditional welded and brazed steel Liquefied Petroleum from 1 January
Annex C) Gas (LPG) cylinders – Periodic inspection 2022
"
– For "EN 16728:2016 (except clause 3.5, Annex F and Annex G)", in column (3),
replace "Until further notice" by:
"Until 31 December 2021".
– After the existing row for "EN 16728:2016 (except clause 3.5, Annex F and Annex
G)", insert the following new row:
"
(1) (2) (3)
LPG equipment and accessories – Transportable refilla- Mandatorily
EN 16728:2016 +
ble LPG cylinders other than traditional welded and from 1 January
A1:2018
brazed steel cylinders – Periodic inspection 2022
"
6.2.5 After the second paragraph, add the following new paragraph:
"As soon as a standard newly referenced in 6.2.2 or 6.2.4 can be applied, the com-
petent authority shall withdraw its recognition of the relevant technical code. A transi-
tional period ending no later than the date of entry into force of the next edition of RID
may be applied."
At the end of the first sentence of the new fourth paragraph (current third paragraph),
add:
"and shall update the list if it changes".
6.2.6.1.5 Amend the first sentence to read as follows:
"The internal pressure of aerosol dispensers at 50 °C shall exceed neither two-thirds
of the test pressure nor 1.2 MPa (12 bar) when using flammable liquefied gases,
1.32 MPa (13.2 bar) when using non-flammable liquefied gases, and 1.5 MPa
(15 bar) when using non-flammable compressed or dissolved gases."
Chapter 6.3
At the end of the title, add:
"(UN Nos. 2814 and 2900)".
6.3.1.1 At the end, add:
", UN Nos. 2814 and 2900".
6.3.4.1 Amend the third sentence to read as follows:
"Letters, numerals and symbols shall be at least 12 mm high, except for packagings
of 30 litres capacity or less or of 30 kg maximum net mass, when they shall be at least
6 mm in height and except for packagings of 5 litres capacity or less or of 5 kg maxi-
mum net mass when they shall be of an appropriate size."
6.3.5.1.5 [The amendment in the German version does not apply to the English text.]
55
[OTIF/RID/CE/2020/1]
6.3.5.1.6 [The amendment in the German version does not apply to the English text.]
6.3.5.2.2 [The amendment to the text before the Table in the German version does not apply
to the English text.]
In the Table, amend the column headings as follows:
– Replace "6.3.5.3.6.1" by:
"6.3.5.3.5.1".
– Replace "6.3.5.3.6.2" by:
"6.3.5.3.5.2".
– Replace "6.3.5.3.6.3" by:
"6.3.5.3.5.3".
Under "Explanation for use of the table", amend the first sub-paragraph as follows:
– Replace "6.3.5.3.6.1" by:
"6.3.5.3.5.1".
– Replace "6.3.5.3.6.2" by:
"6.3.5.3.5.2".
– Replace "6.3.5.3.6.3" by:
"6.3.5.3.5.3".
– At the end, delete:
"five times after conditioning".
6.3.5.3.1 Before the text, add the following new title:
"Drop height and target".
6.3.5.3.2 becomes 6.3.5.3.2.1.
6.3.5.3 Insert the following new 6.3.5.3.2:
"6.3.5.3.2 Number of test samples and drop orientation".
6.3.5.3.3 becomes 6.3.5.3.2.2.
6.3.5.3.2.2 (current 6.3.5.3.3) [The amendments in the German version do not apply to the Eng-
lish text.]
6.3.5.3.4 becomes 6.3.5.3.3.
6.3.5.3.5 becomes 6.3.5.3.4.
6.3.5.3.6 becomes 6.3.5.3.5.
56
[OTIF/RID/CE/2020/1]
6.3.5.3.6.1 becomes 6.3.5.3.5.1.
6.3.5.3.6.2 becomes 6.3.5.3.5.2.
6.3.5.3.6.3 becomes 6.3.5.3.5.3.
Amend as follows:
– Replace "6.3.5.3.6.1" by:
"6.3.5.3.5.1".
– Replace "6.3.5.3.6.2" by:
"6.3.5.3.5.2".
– In the last sentence, replace "in 6.3.5.3.2" by:
"in 6.3.5.3.2.1 or in 6.3.5.3.2.2, as appropriate,".
6.3.5.5.1 [The amendment in the German version does not apply to the English text.]
Chapter 6.4
6.4.2.4 Delete:
"and finished".
6.4.2 Insert the following new 6.4.2.8 to read as follows:
"6.4.2.8 The design of the package shall take into account ageing mechanisms."
Current 6.4.2.8 to 6.4.2.13 become 6.4.2.9 to 6.4.2.14.
6.4.2.11 (current 6.4.2.10) [The amendment in the German version does not apply to the Eng-
lish text.]
6.4.2.12 (current 6.4.2.11) Replace "radiation level" by:
"dose rate".
6.4.4 Amend the sentence after the heading to read as follows:
"An excepted package shall be designed to meet the requirements specified in 6.4.2.1
to 6.4.2.13 and, in addition, the requirements of 6.4.7.2 if it contains fissile material
allowed by one of the provisions of 2.2.7.2.3.5 (a) to (f)."
6.4.5.2 In paragraph (b), replace "radiation level" by:
"dose rate".
6.4.5.4.1 In paragraph (c) (ii), replace "radiation level" by:
"dose rate".
57
[OTIF/RID/CE/2020/1]
6.4.5.4.2 In paragraph (c), replace "radiation level" by:
"dose rate".
6.4.5.4.3 In the first sentence, delete:
"liquids and gases".
In paragraph (c), replace "radiation level" by:
"dose rate".
6.4.5.4.4 In paragraph (c) (ii), replace "radiation level" by:
"dose rate".
6.4.5.4.5 In paragraph (b) (ii), replace "radiation level" by:
"dose rate".
6.4.6.2 In the introductory sentence, replace "it would meet" by:
"the package would meet".
6.4.7.3 [The amendment in the German version does not apply to the English text.]
6.4.7.4 [The amendments in the German version do not apply to the English text.]
6.4.7.9 Replace "it shall be capable" by:
"the containment system shall be capable".
6.4.7.14 In paragraph (b), replace "radiation level" by:
"dose rate".
6.4.7.17 Amend to read as follows
"6.4.7.17 A Type A package designed for gases shall prevent loss or dispersal of the radioactive
contents if the package were subjected to the tests specified in 6.4.16, except for a
Type A package designed for tritium gas or for noble gases.”
6.4.8.2 In paragraph (a), replace "Alter the arrangement" by:
"Alteration of the arrangement".
In paragraph (b), replace "Lessen the efficiency" by:
"Lessening of the efficiency".
Amend paragraph (c) to read:
"(c) Acceleration of corrosion when combined with moisture."
6.4.8.8 In the first indent after paragraph (b) (ii), replace "radiation level" by:
"dose rate".
58
[OTIF/RID/CE/2020/1]
In the last sentence, before "contamination limits", insert:
"non-fixed".
6.4.8.12 [The amendment in the German version does not apply to the English text.]
6.4.9.1 At the beginning of the second sentence, delete:replace "Notwithstanding, the" by:
"Notwithstanding,The".
6.4.10.3 In paragraph (b) (i), replace "radiation level" by:
"dose rate".
6.4.11.2 In paragraph (c) (iv), replace "maximum mass" by:
"total mass".
In paragraph (d), replace "their total concentration" by:
"the total concentration of these materials".
6.4.11.8 [The amendment to the first sentence in the German version does not apply to the
English text.]
[The amendment to the third sentence in the German version does not apply to the
English text.]
In paragraph (b) (i) after "between the valve", insert:
"or the plug".
In paragraph (b) (i), after "the valves", insert:
"and the plug".
6.4.12.1 In paragraph (a), at the beginning, delete:
"LSA-III material, or".
6.4.13 Amend the introductory sentence to read as follows:
"After each test or group of tests or sequence of the applicable tests, as appropriate,
specified in 6.4.15 to 6.4.21:".
6.4.15.4 In paragraph (a), replace "of drop" by:
"of the drop" and add commas before "measured" and after "of the target".
6.4.15.6 In paragraph (b), replace "of drop" by:
"of the drop" and add commas before "measured" and after "of the specimen".
6.4.17.2 In paragraph (b), in the third sentence, replace "section" by:
"cross-section".
59
[OTIF/RID/CE/2020/1]
[The second amendment to (b) in the German version does not apply to the English
text.]
6.4.17.3 In paragraph (b), replace "are everywhere decreasing" by:
"are decreasing in all parts of the specimen".
6.4.23.2 becomes 6.4.23.2.1.
Insert the following new heading:
"6.4.23.2 Applications for approval of shipment".
6.4.23.2 Insert a new paragraph 6.4.23.2.2 to read as follows:
"6.4.23.2.2 An application for approval of SCO-III shipments shall include:
(a) A statement of the respects in which, and of the reasons why, the consignment
is considered SCO-III;
(b) Justification for choosing SCO-III by demonstrating that:
(i) No suitable packaging currently exists;
(ii) Designing and/or constructing a packaging or segmenting the object is not
practically, technically or economically feasible;
(iii) No other viable alternative exists;
(c) A detailed description of the proposed radioactive contents with reference to their
physical and chemical states and the nature of the radiation emitted;
(d) A detailed statement of the design of the SCO-III, including complete engineering
drawings and schedules of materials and methods of manufacture;
(e) All information necessary to satisfy the competent authority that the requirements
of 4.1.9.2.4 (e) and the requirements of 7.5.11, CW 33 (2), if applicable, are sat-
isfied;
(f) A transport plan;
(g) A specification of the applicable management system as required in 1.7.3."
6.4.23.4 Insert a new paragraph (f) to read as follows:
"(f) If the package is to be used for shipment after storage, a justification of consider-
ations to ageing mechanisms in the safety analysis and within the proposed op-
erating and maintenance instructions;".
Current paragraphs (f) to (i) become (g) to (j).
[The amendment to paragraph (g) (current paragraph (f)) in the French version does
not apply to the English text.]
60
[OTIF/RID/CE/2020/1]
At the end of new paragraph (i) (current (h)), delete:
"and".
At the end of new paragraph (j) (current (i)), replace "." by:
"; and".
Add a new paragraph (k) to read as follows:
"(k) For packages which are to be used for shipment after storage, a gap analysis
programme describing a systematic procedure for a periodic evaluation of
changes of applicable regulations, changes in technical knowledge and changes
of the state of the package design during storage."
6.4.23.8 In paragraph (c), replace "calculative methods" by:
"calculations".
6.4.23.10 In paragraph (c), replace "radiation levels" by:
"dose rates".
In paragraph (f), replace "radiation levels" by:
"dose rates".
In paragraph (h), replace "International Basic Safety Standards for Protection against
Ionizing Radiation and for the Safety of Radiation Sources, Safety Series No. 115,
IAEA, Vienna (1996)" by:
"Radiation Protection and Safety of Radiation Sources: International Basic Safety
Standards, IAEA Safety Standards Series No. GSR Part 3, IAEA, Vienna (2014)".
6.4.23.11 At the end of paragraph (c), replace the semicolon by a full stop.
Delete paragraph (d).
6.4.23.12 In paragraph (a), in the first sentence, replace "6.4.23.11 (a), (b), (c) and (d)" by:
"6.4.23.11 (a), (b) and (c)".
In paragraph (a), in the first sentence, delete:
"including, if applicable, the symbol "-96",".
In paragraph (a), at the end of the first sentence, replace "identification marks" by:
"identification mark".
6.4.23.15 In paragraph (k) (iii), replace "contents" by:
"package".
6.4.23.17 In paragraph (n) (iv), replace "contents" by:
"package".
61
[OTIF/RID/CE/2020/1]
Insert a new paragraph (p) to read as follows:
"(p) For package designs subject to the transitional provisions in 1.6.6.2.1, a state-
ment specifying those requirements of RID applicable as from 1 January 2021
with which the package does not conform;".
Current paragraphs (p) to (w) become (q) to (x).
Chapter 6.5
6.5.1.4.3 [The amendment in the German and French version does not apply to the English
text.]
6.5.2.1 Add the following new paragraph 6.5.2.1.3:
"6.5.2.1.3 Where an IBC conforms to one or more than one tested IBC design type, including
one or more than one tested packaging or large packaging design type, the IBC may
bear more than one mark to indicate the relevant performance test requirements that
have been met. Where more than one mark appears on an IBC, the marks shall ap-
pear in close proximity to one another and each mark shall appear in its entirety."
6.5.2.2.1 Delete the last row in the Table ("Maximum permitted stacking load") and the corre-
sponding footnote table note b.
6.5.2.2.2 In the first sentence, delete:
"when the IBC is in use".
6.5.2.2.4 Amend the last sentence of the first sub-paragraph to read as follows:
"They shall be durable, legible and placed in a location so as to be readily accessible
for inspection after assembling the inner receptacle in the outer casing. When the
marks on the inner receptacle are not readily accessible for inspection due to the
design of the outer casing, a duplicate of the required marks on the inner receptacle
shall be placed on the outer casing preceded by the wording "Inner receptacle". This
duplicate shall be durable, legible and placed in a location so as to be readily acces-
sible for inspection."
In the second sub-paragraph, amend the second sentence to read as follows:
"In such a case, the date may be waived from the remainder of the marks."
6.5.5.1.6 At the end of the heading, delete the colon.
Insert a new introductory sentence as follows:
"Metal IBCs with a capacity of more than 1500 litres shall comply with the following
minimum wall thickness requirement:".
Amend the Table under (a) to read as follows:
"
Wall thickness (T) in mm
Types 11A, 11B, 11N Types 21A, 21B, 21N, 31A, 31B, 31N
Unprotected Protected Unprotected Protected
T = C/2000 + 1.5 T = C/2000 + 1.0 T = C/1000 + 1.0 T = C/2000 + 1.5
62
[OTIF/RID/CE/2020/1]
"
6.5.5.4.2 [The amendments in the German version do not apply to the English text.]
6.5.5.4.14 [The amendment in the German version does not apply to the English text.]
6.5.5.4.16 [The amendment in the German version does not apply to the English text.]
6.5.5.6.6 [The amendment in the German version does not apply to the English text.]
6.5.6.1.2 [The amendment in the German version does not apply to the English text.]
6.5.6.14.1 [The amendment in the German version does not apply to the English text.]
Chapter 6.6
6.6.3.3 In the first sentence, delete:
"when the large packaging is in use".
6.6.3 Add the following new paragraph 6.6.3.4:
"6.6.3.4 Where a large packaging conforms to one or more than one tested large packaging
design type, including one or more than one tested packaging or IBC design type, the
large packaging may bear more than one mark to indicate the relevant performance
test requirements that have been met. Where more than one mark appears on a large
packaging, the marks shall appear in close proximity to one another and each mark
shall appear in its entirety."
6.6.5.1.5 [The amendment in the German version does not apply to the English text.]
6.6.5.1.9 [The amendment in the German version does not apply to the English text.]
6.6.5.2.1 [The amendment in the German version does not apply to the English text.]
6.6.5.4.2 [The amendment in the German version does not apply to the English text.]
Chapter 6.7
6.7.2.2.8 [The amendment in the German version does not apply to the English text.]
6.7.2.4.8 [The amendment in the French version does not apply to the English text.]
6.7.2.12.2.1 Amend the definition of factor "U" to read:
"U = heat transfer coefficient of the insulation, in kW·m-2·K-1, at 38 °C;".
6.7.2.18.1 [The amendment in the French version does not apply to the English text.]
6.7.2.19.6 becomes 6.7.2.19.6.1.
6.7.2.19 Insert the following new paragraph 6.7.2.19.6:
"6.7.2.19.6 Inspection and test of portable tanks and filling after the date of expiry of the last
periodic inspection and test".
63
[OTIF/RID/CE/2020/1]
6.7.2.19.6 Insert the following new paragraph 6.7.2.19.6.2:
"6.7.2.19.6.2 Except as provided for in 6.7.2.19.6.1, portable tanks which have missed the
timeframe for their scheduled 5 year or 2.5-year periodic inspection and test may only
be filled and offered for carriage if a new 5-year periodic inspection and test is per-
formed according to 6.7.2.19.4."
6.7.3.2.6 [The amendment in the German version does not apply to the English text.]
6.7.3.2.12 In paragraph (b), replace "thermal conductance" by:
"heat transfer coefficient".
6.7.3.4.1 After paragraph (b), add the following new sub-paragraph:
"In addition, any relevant portable tank special provision indicated in Column (11) of
Table A of Chapter 3.2 and described in 4.2.5.3 shall be taken into account."
6.7.3.4.5 [The amendment in the French version does not apply to the English text.]
6.7.3.5.5 [The amendment in the French version does not apply to the English text.]
6.7.3.8.1.1 Amend the definition of factor "U" to read:
"U = heat transfer coefficient of the insulation, in kW·m-2·K-1, at 38 °C;".
6.7.3.14.1 [The amendment in the French version does not apply to the English text.]
6.7.3.15.6 becomes 6.7.3.15.6.1.
6.7.3.15 Insert the following new paragraph 6.7.3.15.6:
"6.7.3.15.6 Inspection and test of portable tanks and filling after the date of expiry of the last
periodic inspection and test".
6.7.3.15.6 Insert the following new paragraph 6.7.3.15.6.2:
"6.7.3.15.6.2 Except as provided for in 6.7.3.15.6.1, portable tanks which have missed the
timeframe for their scheduled 5 year or 2.5-year periodic inspection and test may only
be filled and offered for carriage if a new 5-year periodic inspection and test is per-
formed according to 6.7.3.15.4."
6.7.4.2.10 [The amendment in the German version does not apply to the English text.]
6.7.4.4.7 [The amendment in the French version does not apply to the English text.]
6.7.4.13.1 [The amendment in the French version does not apply to the English text.]
6.7.4.14.6 becomes 6.7.4.14.6.1.
6.7.4.14 Insert the following new paragraph 6.7.4.14.6:
"6.7.4.14.6 Inspection and test of portable tanks and filling after the date of expiry of the last
periodic inspection and test".
64
[OTIF/RID/CE/2020/1]
6.7.4.14.6 Add a new 6.7.4.14.6.2 to read as follows:
"6.7.4.14.6.2 Except as provided for in 6.7.4.14.6.1, portable tanks which have missed the
timeframe for their scheduled 5 year or 2.5-year periodic inspection and test may only
be filled and offered for carriage if a new 5-year periodic inspection and test is per-
formed according to 6.7.4.14.4."
6.7.5.2.1 [The amendment in the German version does not apply to the English text.]
6.7.5.2.3 In the first sentence, after "seamless steel", insert:
"or composite construction".
6.7.5.2.4 In paragraph (a), replace "ISO 11114-1:2012" by:
"ISO 11114-1:2012 + A1:2017".
6.7.5.4.2 [The amendment in the German version does not apply to the English text.]
6.7.5.11.1 [The amendment in the French version does not apply to the English text.]
Chapter 6.8
[6.8.2.1.2 Amend footnote 1 to read as follows:
1
This requirement is deemed to be met if
(a)
– the notified body in charge of verifying compliance with the technical specifi-
cation for interoperability (TSI) relating to the subsystem "rolling stock –
freight wagons" of the rail system in the European Union (Commission Reg-
ulation (EU) No 321/2013 of 13 March 2013) or
– the assessing entity in charge of verifying compliance with the uniform tech-
nical prescriptions (UTP) applicable to the Rolling Stock subsystem:
FREIGHT WAGONS – (Ref. A 94-02/2.2012 of 1 January 2014)
has successfully evaluated the requirements listed below, in addition to the re-
quirements of the TSI or UTP mentioned above, and has confirmed this compli-
ance by a relevant certificate:
(1) That the maximum working pressure of the tank has been superimposed on
the load cases applicable to the assessment of the ability to withstand
stresses,
(2) That the operating temperature range of the tank has been taken into ac-
count in the load cases applicable to the assessment of the ability to with-
stand stresses,
(3) That the minimum wall thickness of the shell in accordance with RID 6.8.2.1
and 6.8.2.6 has been taken into account in the load cases applicable to the
assessment of the ability to withstand stresses,
(4) Special provisions TE 22 and TE 25 in accordance with RID 6.8.4 (b).
65
[OTIF/RID/CE/2020/1]
To evaluate points (1) to (3), the procedures and maximum allowable stresses
according to the TSI or UTP and its referenced standards shall be applied;
and
(b)
for tanks with a protective lining, that the competent authority for the design type
test in accordance with RID 6.8.2.3.1 or a body designated by that authority has
assessed and certified the ability of the protective lining, particularly those with
weaker elastic properties than the shell, e.g. hard rubber or enamel, to withstand
the stresses in the load cases. The necessary data resulting from the load cases
shall be exchanged between the bodies involved."]
6.8.2.1.11 Replace "welded tanks" by:
"welded shells".
6.8.2.1.18 Delete footnote 5 and the reference to footnote 5.
6.8.2.1.19 Delete the reference to footnote 5 (twice).
Renumber footnotes 6 to 23 as footnotes 5 to 22.
6.8.2.2.2 [The amendment in the German version does not apply to the English text.]
6.8.2.5.1 In the ninth indent, replace "test" by:
"inspection" (five six times).
In the tenth indent, replace "tests" by:
"inspection".
6.8.2.6.1 Amend the Table, under "for design and construction of tanks", as follows:
– For "EN 14025:2013 + A1:2016 (except Annex B)", in column (4), replace "Until
further notice" by:
"Between 1 January 2017 and 31 December 2021".
– After "EN 14025:2013 + A1:2016 (except Annex B)", insert the following new
rows:
"
(1) (2) (3) (4) (5)
Tanks for the transport of dangerous goods
– Metallic pressure tanks – Design and
construction 6.8.2.1 Until fur-
EN 14025:2018 NOTE: Materials of shells shall at least and ther no-
be attested by a type 3.1 certifi- 6.8.3.1 tice
cate issued in accordance with
standard EN 10204.
Mandato-
Tanks for transport of dangerous goods –
rily from
EN 12972:2018 Testing, inspection and marking of metallic 6.8.2.3
1 Janu-
tanks
ary 2022
"
66
[OTIF/RID/CE/2020/1]
6.8.2.6.2 Amend the Table as follows:
– For "EN 12972:2007", in column (4), replace "Until further notice" by:
"Until 30 June 2021".
– After "EN 12972:2007", insert the following new row:
"
(1) (2) (3) (4) (5)
Mandato-
Tanks for transport of dangerous goods –
6.8.2.4 rily from
EN 12972:2018 Testing, inspection and marking of metallic
6.8.3.4 1 July
tanks
2021
"
6.8.2.7 After the first sub-paragraph, insert the following new sub-paragraph:
"As soon as a standard newly referenced in 6.8.2.6 can be applied, the competent
authority shall withdraw its recognition of the relevant technical code. A transitional
period ending no later than the date of entry into force of the next edition of RID may
be applied."
At the end of the first sentence of the new third sub-paragraph (current second sub-
paragraph), add:
"and shall update the list if it changes".
6.8.3.1.3 In the second sub-paragraph, replace "footnote 6" by:
"footnote 5".
6.8.3.4.12 In the third sentence, replace "6.8.3.4.6" by:
"6.8.2.4.2 and 6.8.2.4.3".
6.8.3.5.10 In the seventh indent, replace "test" by:
"inspection" (twice).
In the eighth indent, replace "tests" by:
"inspection".
6.8.3.5.11 In the last indent of the left-hand column, replace "test" by:
"inspection".
6.8.3.7 After the first sub-paragraph, insert the following new sub-paragraph:
"As soon as a standard newly referenced in 6.8.3.6 can be applied, the competent
authority shall withdraw its recognition of the relevant technical code. A transitional
period ending no later than the date of entry into force of the next edition of RID may
be applied."
At the end of the first sentence of the new fourth sub-paragraph (current third sub-
paragraph), add:
"and shall update the list if it changes".
67
[OTIF/RID/CE/2020/1]
6.8.4 (b)
TE 12 [The amendment in the German version does not apply to the English text.]
6.8.4 (d)
TT 6 Amend the text in the left-hand column to read:
"The periodic inspection shall be carried out at least every 4 years."
TT 8 In the first sub-paragraph, replace "test" by:
"inspection".
Chapter 6.9
6.9.4.3.4 [The amendment in the German version does not apply to the English text.]
6.9.6.1 At the end of the second indent, replace full stop by a semicolon.
Add a new third indent to read as follows:
"– the second part of the tank code shall indicate the highest value of the calculation
pressure for the substance(s) permitted for carriage according to the type approval
certificate."
Chapter 6.10
6.10.3.5 [The amendment to paragraph (d) in the French version does not apply to the English
text.]
6.10.3.8 In paragraph (a), add a new Note to read as follows:
"NOTE: This requirement may, for example, be complied with by the use of a verti-
cal pipe or a low-level outlet with a connection which allows, when neces-
sary, attachment of a hose."
6.10.4 Replace "tests" by:
"inspection".
Chapter 6.11
6.11.4.1 In the Note, replace "the UIC leaflets 591, 592 and 592- 2 to 592-4" by:
"IRS 50591 ("Roller units for horizontal transhipment – Technical conditions govern-
ing their use in international traffic")2 and IRS 50592 ("Intermodal Transport Units
(other than semi-trailers) for vertical transhipment and suitable for carriage on wagons
– Minimum requirements")3 published by UIC".
Footnotes 2 and 3 read as follows:
"2 1st First edition of IRS (International Railway Solution) applicable as from 1 Jan-
uary 2020.
3
1st First edition of IRS (International Railway Solution) applicable as from 1 Jan-
uary 2019."
68
[OTIF/RID/CE/2020/1]
Current footnote 2 becomes footnote 4.
6.11.5.4.1 [The amendment in the German version does not apply to the English text.]
PART 7
Chapter 7.1
7.1.3 Replace "UIC leaflets 591 (status at 01.10.2007, 3rd edition), 592 (status at
01.10.2013, 2nd edition), 592-2 (status at 01.10.2004, 6th edition), 592-3 (status at
01.01.1998, 2nd edition) and 592-4 (status at 01.05.2007, 3rd edition)" by:
"IRS 50591 ("Roller units for horizontal transhipment – Technical conditions govern-
ing their use in international traffic")1 and IRS 50592 ("Intermodal Transport Units
(other than semi-trailers) for vertical transhipment and suitable for carriage on wagons
– Minimum requirements")2 published by UIC".
At the end, replace "UIC leaflets 591, 592 and 592-2 to 592-4" by:
"IRS 50591 and IRS 50592 of UIC".
Footnotes 1 and 2 read as follows:
"1 1st First edition of IRS (International Railway Solution) applicable as from 1 Jan-
uary 2020.
2
1st First edition of IRS (International Railway Solution) applicable as from 1 Jan-
uary 2019."
Current footnotes 1 and 2 become footnotes 3 and 4.
Chapter 7.5
7.5.1.4 [The amendment in the French version does not apply to the English text.]
7.5.11
CW 33 In paragraph (2), after the first sentence, add the following new sentence:
"For SCO-III, the limits in Table C below may be exceeded provided that the transport
plan contains precautions which are to be employed during carriage to obtain an over-
all level of safety at least equivalent to that which would be provided if the limits had
been applied."
Amend paragraph (3.3) (b) to read as follows:
"(b) The dose rate under routine conditions of carriage shall not exceed 2 mSv/h at
any point on the external surface of the wagon or container, and 0.1 mSv/h at 2 m
from the external surface of the wagons or container, except for consignments
carried under exclusive use for which the dose rate limits around the wagon are
set forth in (3.5) (b) and (c)."
In paragraph (3.5), replace "radiation level" by:
"dose rate".
69
[OTIF/RID/CE/2020/1]
In paragraph (5.1), replace "radiation level" by:
"dose rate".
In paragraph (5.1), in the last sentence, replace "persons" by:
"people,".
In paragraph (5.4), replace "radiation level" by:
"dose rate" (twice).
In paragraph (5.5), at the beginning, delete:
", tank, intermediate bulk container".
CW 36 Amend the second sentence to read as follows:
"If this is not feasible and packages are carried in other closed wagons or containers,
gas exchange between the load compartment and accessible compartments during
carriage shall be prevented and the cargo doors of the wagons or containers shall be
marked with the following in letters not less than 25 mm high:
"WARNING
NO VENTILATION
OPEN WITH CAUTION"".
Chapter 7.6
CE 1 [The amendment in the French version does not apply to the English text.]
__________
70