dokumendiregister.ee
OtsingAsutusedMCP
dokumendiregister.eeAsutusedEesti avalike dokumendiregistrite otsing · nimistu.ee andmetel
Otsing›Tarbijakaitse ja Tehnilise Järelevalve Amet
Väljaminev kiriAvalik

Koordinatsioonitaotlus DVB-T Tallinn Kristiina ch.30

Tarbijakaitse ja Tehnilise Järelevalve Amet · 24. august 2011
Viit
11-0807-002
Registreeritud
24. august 2011
Dokumendi liik
Väljaminev kiri
Adressaat
Finnish Communications Regulatory Authority
Funktsioon
6.15S Sageduste haldus (2009-2013) (Suletud)
Sari
6.15-5S Sagedushalduse sisenevad ja väljuvad koordinatsioonid (Suletud)
Toimik
11-0807
Vastutaja
TJA Migratsioon (Sagedushalduse osakond)

Failid

  • 📎est_fin_29.08.2011.docx22 KB
  • 📎tln_kri_30.txt3 KB

Sisu (failidest)

Finnish Communication Regulatory Authority P.O.Box 313 FI-00181 Helsinki, Finland [email protected] Our ref: 29 . 0 8 .2011 No 6.15-5/10-0807-002 Subject: Regional Broadcasting Agreement, Geneva 2006 Dear Si r /Madam In accordance with the Article 4 of the Regional Broadcasting Agreement, Geneva 2006 the Estonian Technical Surveillan ce Authority seeks for your approval of the following new Estonian assignment : TALLINN KRISTIINA ch.30 (ADD) The complete technic al characte ristics of the above assignment a re given in the enclosed file tln _ kri_29.08.2011 .txt and have been sent to the e-mail address [email protected] with a copy to [email protected] . We look forward receiving your prompt comments. Your sincerely Alo Einla Head of Frequency Management Department NB ! This letter has been sent by e-mail only. Vladimir Jakovlev Tel. + 372 667 2123; Fax: + 372 667 213 2; [email protected] <HEAD> t_char_set = ISO-8859-1 t_email_addr = [email protected] t_adm = EST </HEAD> <NOTICE> t_notice_type = GT1 t_fragment = GE06D t_action = ADD t_adm_ref_id = TLN KRISTIINA_30_6 t_freq_assgn = 546.000 t_ctry = EST t_site_name = TALLINN KRISTIINA t_long = +0244419 t_lat = +592532 t_is_pub_req = TRUE t_plan_entry = 4 t_associated_adm_allot_id = EST-05-01-TLN t_associated_allot_sfn_id = TLN30 t_assgn_code = L t_eff_hgtmax = 112 t_erp_v_dbw = 29.031 t_hgt_agl = 98 t_polar = V t_site_alt = 14 <ANT_HGT> t_eff_hgt@azm0 = 111 t_eff_hgt@azm10 = 112 t_eff_hgt@azm20 = 107 t_eff_hgt@azm30 = 102 t_eff_hgt@azm40 = 96 t_eff_hgt@azm50 = 99 t_eff_hgt@azm60 = 87 t_eff_hgt@azm70 = 73 t_eff_hgt@azm80 = 70 t_eff_hgt@azm90 = 69 t_eff_hgt@azm100 = 68 t_eff_hgt@azm110 = 69 t_eff_hgt@azm120 = 66 t_eff_hgt@azm130 = 64 t_eff_hgt@azm140 = 66 t_eff_hgt@azm150 = 67 t_eff_hgt@azm160 = 64 t_eff_hgt@azm170 = 62 t_eff_hgt@azm180 = 58 t_eff_hgt@azm190 = 60 t_eff_hgt@azm200 = 64 t_eff_hgt@azm210 = 67 t_eff_hgt@azm220 = 69 t_eff_hgt@azm230 = 72 t_eff_hgt@azm240 = 79 t_eff_hgt@azm250 = 88 t_eff_hgt@azm260 = 89 t_eff_hgt@azm270 = 90 t_eff_hgt@azm280 = 101 t_eff_hgt@azm290 = 108 t_eff_hgt@azm300 = 111 t_eff_hgt@azm310 = 110 t_eff_hgt@azm320 = 109 t_eff_hgt@azm330 = 110 t_eff_hgt@azm340 = 110 t_eff_hgt@azm350 = 112 </ANT_HGT> <ANT_DIAGR_V> t_attn@azm0 = 7.3 t_attn@azm10 = 9.0 t_attn@azm20 = 11.0 t_attn@azm30 = 13.5 t_attn@azm40 = 16.0 t_attn@azm50 = 19.5 t_attn@azm60 = 21.5 t_attn@azm70 = 20.5 t_attn@azm80 = 19.0 t_attn@azm90 = 17.5 t_attn@azm100 = 16.5 t_attn@azm110 = 16.5 t_attn@azm120 = 17.5 t_attn@azm130 = 19.0 t_attn@azm140 = 20.5 t_attn@azm150 = 21.5 t_attn@azm160 = 19.5 t_attn@azm170 = 16.0 t_attn@azm180 = 13.5 t_attn@azm190 = 11.0 t_attn@azm200 = 9.3 t_attn@azm210 = 7.5 t_attn@azm220 = 5.8 t_attn@azm230 = 4.3 t_attn@azm240 = 3.0 t_attn@azm250 = 2.0 t_attn@azm260 = 1.0 t_attn@azm270 = 0.3 t_attn@azm280 = 0.0 t_attn@azm290 = 0.0 t_attn@azm300 = 0.3 t_attn@azm310 = 1.0 t_attn@azm320 = 2.0 t_attn@azm330 = 3.0 t_attn@azm340 = 4.3 t_attn@azm350 = 5.8 </ANT_DIAGR_V> t_ant_dir = D t_ref_plan_cfg = RPC2 t_sfn_id = TLN30 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <TAIL> t_num_notices = 1 </TAIL> ======================================================================================== The input file has been validated with GE06 DVal BCBT Digital Version 2.08 / 08.04.2009 File Structure : OK Basic Data Validation : OK Data Validation with the validation of geographical coordinates: OK To complete the Validation, please use Data Correction Software On 24.08.2011 - 9:48:34 by vladimir Number of notices validated 1 FILE READY FOR FURTHER VALIDATION IN DATA CORRECTION SOFTWARE ========================================================================================
Allikas: Tarbijakaitse ja Tehnilise Järelevalve Amet dokumendiregister →