Annex 14 — Aerodromes Volume I Table 6-1. Characteristics of obstacle lights 1 2 3 4 5 6 7 Peak intensity (cd) at given Background Luminance (b) Light Signal type/ Day Twilight Night Distribution Light Type Colour (flash rate) (Above 500 cd/m2) (50-500 cd/m2) (Below 50 cd/m2) Table Low-intensity, Type A Red Fixed N/A N/A 10 (fixed obstacle) Table 6-2 Low-intensity, Type B Red Fixed N/A N/A 32 (fixed obstacle) Table 6-2 Low-intensity, Type C Yellow/Blue Flashing N/A 40 40 (mobile obstacle) (a) (60-90 fpm) Table 6-2 Low-intensity, Type D Yellow Flashing N/A 200 200 (follow-me vehicle) (60–90 fpm) Table 6-2 Medium-intensity, Type A White Flashing 20 000 20 000 2 000 (20–60 fpm) Table 6-3 Medium-intensity, Type B Red Flashing N/A N/A 2 000 (20–60 fpm) Table 6-3 Medium-intensity, Type C Red Fixed N/A N/A 2 000 Table 6-3 High-intensity, White Flashing 200 000 20 000 2 000 Type A (40–60 fpm) Table 6-3 High-intensity, White Flashing 100 000 20 000 2 000 Type B (40–60 fpm) Table 6-3 a) See 6.2.2.6 b) For flashing lights, effective intensity as determined in accordance with the Aerodrome Design Manual (Doc 9157), Part 4. 14/11/13 6-4 Chapter 6 Annex 14 —Aerodromes Table 6-2. Light distribution for low-intensity obstacle lights Minimum intensity Maximum intensity Vertical beam spread (a) (a) (f) Minimum beam spread Intensity Type A 10 cd (b) N/A 10° 5 cd Type B 32 cd (b) N/A 10° 16 cd Type C 40 cd (b) 400 cd 12° (d) 20 cd Type D 200 cd (c) 400 cd N/A (e) N/A Note.— This table does not include recommended horizontal beam spreads. 6.2.1.3 requires 360° coverage around an obstacle. Therefore, the number of lights needed to meet this requirement will depend on the horizontal beam spreads of each light as well as the shape of the obstacle. Thus, with narrower beam spreads, more lights will be required. a) 360° horizontal. For flashing lights, the intensity is read into effective intensity, as determined in accordance with the Aerodrome Design Manual (Doc 9157), Part 4. b) Between 2 and 10° vertical. Elevation vertical angles are referenced to the horizontal when the light is levelled. c) Between 2 and 20° vertical. Elevation vertical angles are referenced to the horizontal when the light is levelled. d) Peak intensity should be located at approximately 2.5° vertical. e) Peak intensity should be located at approximately 17° vertical. f) Beam spread is defined as the angle between the horizontal plane and the directions for which the intensity exceeds that mentioned in the “intensity” column. Table 6-3. Light distribution for medium- and high-intensity obstacle lights according to benchmark intensities of Table 6-1 Benchmark Minimum requirements Recommendations intensity Vertical elevation angle (b) Vertical elevation angle (b) Vertical beam spread Vertical beam spread 0° -1° (c) 0° -1° -10° (c) Minimum Minimum Maximum average Minimum Minimum beam Maximum Maximum Maximum beam intensity intensity intensity spread Intensity intensity intensity intensity spread Intensity (a) (a) (a) (a) (a) (a) (a) (a) 200 000 200 000 150 000 75 000 3° 75 000 250 000 112 500 7 500 7° 75 000 100 000 100 000 75 000 37 500 3° 37 500 125 000 56 250 3 750 7° 37 500 20 000 20 000 15 000 7 500 3° 7 500 25 000 11 250 750 N/A N/A 2 000 2 000 1 500 750 3° 750 2 500 1 125 75 N/A N/A Note.— This table does not include recommended horizontal beam spreads. 6.2.1.3 requires 360° coverage around an obstacle. Therefore, the number of lights needed to meet this requirement will depend on the horizontal beam spreads of each light as well as the shape of the obstacle. Thus, with narrower beam spreads, more lights will be required. a) 360° horizontal. All intensities are expressed in Candela. For flashing lights, the intensity is read into effective intensity, as determined in accordance with the Aerodrome Design Manual (Doc 9157), Part 4. b) Elevation vertical angles are referenced to the horizontal when the light unit is levelled. c) Beam spread is defined as the angle between the horizontal plane and the directions for which the intensity exceeds that mentioned in the “intensity” column. Note.— An extended beam spread may be necessary under specific configuration and justified by an aeronautical study. 6-5 14/11/13 Teie 10.10.2016 Heiki Haas Vändra Vallavalitsus Meie 14.10.2016 nr 4.6-8/16/3319-2 Tootsi tuulepargi projekteerimistingimuste kooskõlastamine Austatud hr Haas Pärnumaale Tootsi Suursoo ammendunud turbamaardlasse kavandatav kuni 52 elektrituulikust koosnev tuulepark asub väljaspool Pärnu lennuvälja lähiümbruse piirangupindu ega mõjuta praegu kehtivaid lennuprotseduure. 240 meetri kõrgustest tuulikutest koosnev tuulepark on oluline lennutakistus, mistõttu saab Lennuamet lennundusseaduse § 35 lg 3 alusel kooskõlastada projekteerimistingimused üksnes järgmiste nõuete lisamisel:  tuulepargi perimeetril asuvad tuulikud tuleb varustada lennuohutustuledega nii, et tulede vahe ei ületaks 900 meetrit;  lennuohutustule parameetrid peavad vastama Rahvusvahelise Tsiviillennunduse Konventsiooni Lisa 14 (ICAO Annex 14) 1. osa tabelis 6-1 ja 6-3 medium-intensity, Type B tulele kehtestatud nõuetele (vt lisa);  tuled peavad olema õhust nähtavad igalt küljelt lähenedes;  tuulepargi muudetud projekteerimistingimused kooskõlastada enne taotlejale väljastamist täiendavalt Lennuametiga. Eelnimetatud nõuete projekteerimistingimustesse lisamata jätmise korral Lennuameti kooskõlastus ei kehti. Arvestades Pärnu lennuvälja võimalikke arenguplaane ja selle suhtelist lähedust planeeritavale tuulikupargile soovitame võimalusel kaaluda labade valgustamise võimaluse loomist. Lugupidamisega (allkirjastatud digitaalselt) Kristo Vallimäe osakonna juhataja Lõõtsa 5 / 11415 Tallinn / 610 3500 / [email protected] / www.ecaa.ee Registrikood 70000800 Lisa: ICAO Annex 14 tabel 6-1 ja 6-3, 2 lehel. Andres Lainoja 610 3590 [email protected]
Allikas: Lennuamet dokumendiregister →
dokumendiregister.eeAsutusedEesti avalike dokumendiregistrite otsing · nimistu.ee andmetel