dokumendiregister.ee
OtsingAsutusedMCP
Otsing›Sotsiaalministeerium
Sissetulev kiriAvalik

2018 National MR Laboratory Accreditation CRM:0081420

Sotsiaalministeerium · 16. august 2017
Viit
1.4-2/3207-1
Registreeritud
16. august 2017
Dokumendi liik
Sissetulev kiri
Adressaat
World Health Organization
Saabumis/saatmisviis
e-post
Funktsioon
1.4 EL otsustusprotsess ja rahvusvaheline koostöö
Sari
1.4-2 Rahvusvahelise koostöö korraldamisega seotud kirjavahetus (Arhiiviväärtuslik)
Toimik
1.4-2/2017
Vastutaja
Jürgen Ojalo (SM, Eurokoordinatsiooni ja välissuhete osakond)

Failid

  • 📎Estonia, MR summary of review, 2016.pdf70 KB
  • 📎Letter to Jevgeni Ossinovski.pdf68 KB

Sisu (failidest)

Measles and Rubella Laboratory Check-list for Annual WHO Accreditation Date of Review: 01.01 – 31.12.2016 By correspondence Accreditation for calendar year: 2018 Laboratory: Laboratory of Communicable Diseases Institute: Health Board Address: Kotka 2, 11315, Tallinn Country Estonia Phone: +3726943635 Email: [email protected] Website: www.terviseamet.ee +3726943671 [email protected] Head of Institute: Dr Tiiu Aro Head of Department: Külli Rae Head of Laboratory: Külli Rae Head Mea/Rub Lab: Svetlana Rudõka Chief Technician: Svetlana Rudõka Name of Laboratory used for Virus Isolation/Detection: HB Laboratory of Communicable Diseases Name of Laboratory used for Virus Sequencing: HB Laboratory of Communicable Diseases in collaboration with Estonian Biocentre (Laboratories that act as a reference laboratory for sub-national laboratories should complete annex I to the checklist) Reviewers: Dr. Myriam Ben Mamou & Dovile Videbaek, WHO EURO Name of National Accrediting Authority (if appropriate) and current accreditation status from this authority (e.g. ISO15189 or other, provide documentation): Estonian Accreditation Centre certified on 30.06.2014 that Communicable Diseases Laboratory for HB has competence according to ISO 15189:2007 as a medical laboratory to conduct researches in the field of clinical and microbiological research. The accreditation shall remain in effect until 29.06.2019. Part I: Summary of Review (assessor to complete) Recommendations: Measles Rubella Serology RT-PCR Sequencing Serology RT-PCR Sequencing Accredited1 Provisionally accredited2 Do not accredit3 1 Laboratory meets all criteria 2 Laboratory passed the most recent serology PT, but needs to strengthen one or more of the remaining criteria 3 Laboratory did not pass the most recent serology PT or molecular EQA Findings: Measles and rubella IgM test results are reported by the laboratory to the Measles: 100% 1. surveillance system within 4 days for ≥ 80% of specimens: Rubella: 95% Completeness 100% 2. The laboratory reports to MRLDMS weekly and/or to CISID monthly Timeliness 92% Measles: 176 3. IgM tests are performed on at least 50 specimens annually: Rubella: 176 Measles: 100% 4. The accuracy of IgM detection is ≥ 90% (38 samples) Rubella: 100% 5. Internal quality control (QC) procedures are implemented: (Yes/No/Partially) Partially The score on the most recent WHO proficiency test is ≥ 90%: Measles: 97.73% 6. PT panel number: 01602 Date reported: 03/02/17 Rubella: 97.73% Performance on the most recent WHO Molecular proficiency test (if 7. NA appropriate): Round: Date reported: dd/mm/yy Virus genotyping (if performed) is completed AND data reported to WHO MeaNS: 8. through MeaNS or RubeNS within 2 months of receipt of specimens, for ≥80% NA RubeNS : of the specimens appropriate for genetic analysis: The score from the on-site review of laboratory operating procedures and practices is ≥ 9. NA 80%: Key accreditation criteria 5- Routine internal quality control procedures should be strengthened. 6- Measles and rubella in-house should be used. (Collaborate with RRL if needed). Conclusion • Excellent performance.
Allikas: Sotsiaalministeerium dokumendiregister →
dokumendiregister.eeAsutusedEesti avalike dokumendiregistrite otsing · nimistu.ee andmetel