Notification of types of gas and corresponding
supply pressures of gaseous fuels relating to
Article 4(1) Regulation (EU) 2016/426 on
appliances burning gaseous fuels
According to Article 4 (1), Member States shall communicate to the Commission and the other
Member States in accordance with Annex II and using the relevant form the types of gas and
corresponding supply pressures of gaseous fuels used on their territory by 21 October 2017. They
shall communicate any changes thereof within six months after the announcement of the envisaged
changes.
In view of the above, please find attached the belated data of Estonia about the types of gas and
corresponding supply pressures of gaseous fuels.
With best regards,
Kristi Talving
Deputy Secretary General for Internal Market
Enclosure: Annex II
Merike Ring
+372 6256472
[email protected]
Suur-Ameerika 1 / 10122 Tallinn / ESTONIA
Phone: +372 625 6342 / Fax: +372 631 3660 / E-mail:
[email protected] / http://www.mkm.ee
ANNEX II
CONTENT OF THE MEMBER STATES COMMUNICATIONS OF THE GAS SUPPLY
CONDITIONS
1. The communications of the Member States to the Commission and the other Member States
provided for in Article 4 shall have the following content:
(a) (i) gross calorific value (GCV) in MJ/m3 min 35,53 / max - ;
(ii) Wobbe index in MJ/m3 min 47,89 / max 52,95.
(b) Gas composition by volume in % of the total content:
— C1 to C5 content in % (sum) min - / max 100;
— N2 + CO2 content in % N2 < 3 / CO2 < 2,5
— CO content in % min - / max - ;
— unsaturated HC content in % min - / max -;
— hydrogen content in % min - /max 0,1.
(c) Information on toxic components contained in the gaseous fuel.
That communication shall also include either of the following:
(a) supply pressure at the inlet of appliances in mbar: nominal/minimum/maximum
(20/18/25);
(b) (i) supply pressure at the point of delivery in mbar: nominal/minimum/maximum
(23/18/25);
(ii) admissible pressure loss in the end-user gas installation in mbar:
nominal/minimum/maximum (1,5/1,0/2,0).
2. The reference conditions for Wobbe index and gross calorific value shall be the following:
(a) combustion reference temperature: 15 °C;
(b) volume measurement reference temperature: 15 °C;
(c) volume measurement reference pressure: 1 013,25 mbar.