AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
SELETUSKIRI
SISUKORD
1. ÜLDOSA ...................................................................................................................................................... 3
1.1 Üldandmed ................................................................................................................ 3
1.1.1 Ehitise asukoht ......................................................................................................... 3
1.1.2 Ehitise lühikirjeldus .................................................................................................. 3
1.1.3 Tellija .......................................................................................................................... 3
1.1.4 Projekteerija .............................................................................................................. 3
1.2 Alusdokumendid ....................................................................................................... 3
1.2.1 Lähteandmed ............................................................................................................ 3
1.2.2 Ehitusuuringud ......................................................................................................... 3
1.3 Olemasolev olukord ................................................................................................. 4
1.3.1 Ristumised ja liiklus ................................................................................................. 4
1.3.2 Katete iseloomustus ................................................................................................. 4
1.3.3 Olevad tehnovõrgud ................................................................................................. 4
1.3.4 Normdokumendid ..................................................................................................... 4
2. PROJEKTLAHENDUS ................................................................................................................................. 5
2.1 Projekteeritud teede põhinäitajad ........................................................................... 5
2.1.1 Vertikaalplaneerimine............................................................................................... 5
2.1.2 Ristprofiil ................................................................................................................... 5
2.2 Liikluskorraldus ........................................................................................................ 5
2.2.1 Liiklusmärgid ............................................................................................................ 6
2.2.2 Teekattemärgistus .................................................................................................... 6
2.3 Katendikonstruktsioonid ......................................................................................... 6
3. EHITAMINE .................................................................................................................................................. 8
3.1 Üldandmed ................................................................................................................ 8
3.2 Ettevalmistustööd ..................................................................................................... 9
3.2.1 Geodeetiline alusvõrk ja väljamärkimine ............................................................... 9
3.3 Liikluskorraldus ehituse ajal ................................................................................... 9
3.4 Olemasoleva katendi likvideerimine ....................................................................... 9
3.5 Tee ehitus .................................................................................................................. 9
3.5.1 Mullatööd ................................................................................................................... 9
3.5.2 Muldkeha ja keskliiva kiht ...................................................................................... 10
3.5.3 Aluse ehitus ............................................................................................................ 10
3.5.4 Katendi pealiskihtide ehitus .................................................................................. 10
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 1/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
3.5.5 Sillutiskivi paigaldus .............................................................................................. 10
3.5.6 EPDM katendi paigaldus ........................................................................................ 11
3.6 Liikluskorraldusvahendid ...................................................................................... 11
3.7 Keskkonnakaitse .................................................................................................... 11
4. TEEDE KASUTAMISE JA HOOLDUSE JUHEND....................................................................................... 12
JOONISED ............................................................................................................................................................... 12
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 2/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
1. ÜLDOSA
1.1 Üldandmed
1.1.1 Ehitise asukoht
Jõgeva maakond, Mustvee linn:
Tartu tn 11 (48501:006:0046)
Tähe tn 4 (48501:001:0068)
Tartu kõnnitee L2 (48601:001:0524)
36 Jõgeva-Mustvee tee L7 (48501:006:0054)
Tähe tänav (48501:001:0152)
1.1.2 Ehitise lühikirjeldus
Antud projekti osas on projekteeritud Tartu tn 11 ja Tähe tn 4 kinnistutel
juurdepääsuteed, parkla, kõnniteed ning mängualad.
Tähe tänav kinnistule on projekteeritud ol.ol. mahasõidu rekonstrueerimine.
Tartu kõnnitee L2 kinnistul on projekteeritud ol.ol. kõnnitee rekonstrueerimine
ning 36 Jõgeva – Mustvee tee L7 kinnistul on projekteeritud katete taastamine
ning mahasõitude rekonstrueerimine.
1.1.3 Tellija
Mustvee Vallavalitsus
Tartu tn 28, Mustvee, Jõgeva maakond
[email protected]
Kontaktisik: Reili Tooming
1.1.4 Projekteerija
1.1.4.1 Projekteerimise projektijuht
Infragate Eesti AS
Projektijuht Liina Mürk
Mobiil +372 56 466 840
[email protected]
1.1.4.2 Teede projekteerija
Infragate Eesti AS
Roman Sokmann
Mobiil +372 50 120 67
[email protected]
Kutsetunnistus: 211497
1.2 Alusdokumendid
1.2.1 Lähteandmed
1.2.1.1 Lähteülesanne
Tellija lähteülesanne
1.2.2 Ehitusuuringud
Geodeetilised uuringud teostas OÜ Inseneribüroo REIB töö nr. TT-7172T
(04.2025). Lisaks on abiks kasutatud OÜ Inseneribüroo REIB töö nr. TT-
6736T (11.2023). Geodeesia uuringu failid asuvad eraldi geodeesia kaustas.
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 3/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
1.3 Olemasolev olukord
1.3.1 Ristumised ja liiklus
Projektalale ligipääs on Tartu tn ja Tähe tn poolt läbi ol.ol. mahasõite.
1.3.2 Katete iseloomustus
Hoone ümbruses esineb – kunstmurust miniareena, kruusast ja asfaldist sõidu-
ja kõnniteid ning rohkesti haljastust.
Tartu tn on asfaldist sõidu- ja kõnniteed. Tähe tn on asfaldist sõidutee.
1.3.3 Olevad tehnovõrgud
Uuritaval maa-alal asuvad sademevee-, vee-, kanalisatsiooni-, side-, termo-,
madalpingetrassid. Lisaks esineb side- ja madalpingeõhuliine.
1.3.4 Normdokumendid
Projektlahenduse koostamise aluseks on järgmised standardid ja juhendid:
Seadused
- EV Ehitusseadustik, vastu võetud 11.02.2015 ja tulenevalt kehtestatud
nõuded (Redaktsiooni jõustumise kp. 25.04.2025).
Määrused
- Kliimaministri määrus: Tee projekteerimise normid; vastu võetud
17.11.2023 nr 71 (Redaktsiooni jõustumise kp: 25.11.2023).
- Majandus- ja taristuministeeriumi määrus: Tee ehitamise kvaliteedi
nõuded; vastu võetud 03.08.2015 nr 101 (Redaktsiooni jõustumise kp:
29.11.2024).
- Majandus- ja taristuministeeriumi määrus: Tee ehitusrojektile esitatavad
nõuded; vastu võetud 09.01.2020 nr 2 (Redaktsiooni jõustumise kp:
23.11.2020).
- Majandus- ja taristuministeeriumi määrus: Tee seisundinõuded; vastu
võetud 14.07.2015 nr 92 (Redaktsiooni jõustumise kp: 05.11.2018).
- Nõuded ajutisele liikluskorraldusele. Vastu võetud 13.07.2018 nr 43
(Redaktsiooni jõustumise kp: 01.01.2019).
Standardid
- EVS 901-1:2020 Tee-ehitus Osa 1: Asfaltsegude täitematerjalid;
- EVS 901-2:2016 Tee-ehitus Osa 2: Bituumensideained;
- EVS 901-3:2021 Tee-ehitus Osa 3: Asfaltsegud;
- EVS-EN 13285:2018 Sidumata segud. Spetsifikatsioon;
- EVS-EN 13242:2006+A1:2008. Ehitustöödel ja tee-ehituses kasutatavad
sidumata ja hüdrauliliselt seotud täitematerjalid;
- EVS-EN 13282-3:2024 Hüdrauliline teesideaine. Osa 3:
Vastavushindamine;
- EVS-EN1340: 2003+AC:2006/AC:2014 Betoonist äärekivid. Nõuded ja
katsemeetodid;
- EVS-EN 1338: 2003+AC:2006/AC2024 Betoonist sillutisekivid. Nõuded
ja katsemeetodid;
- EVS 814:2020 Normaalbetooni külmakindlus, Määratlused,
spetsifikatsioonid ja katsemeetodid;
- EVS 613:2023 Liiklusmärgid ja nende kasutamine;
- EVS 614:2022:Teemärgised ja nende kasutamine
- EVS 843:2016 Linnatänavad
- Maa RYL 2010 Ehitustööde üldised kvaliteedinõuded. Pinnasetööd ja
alustarindid;
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 4/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
2. PROJEKTLAHENDUS
Projekteeritud lahenduse eesmärgiks on projekteeritava hoone ümbruses parkla,
juurdepääsu- ja kõnniteede rajamine/rekonstrueerimine ning tehnovõrkude
rajamise kohal katendite taastamine.
Sademeveed on suunatud haljasaladele. Lisaks haljasaladel on projekteeritud
immutusala.
Tööd on koostatud vastavalt lähteülesandele, Tellija soovidele ja arhitektuursele
plaanile.
Projektlahendus on asendiplaaniliselt, vertikaalselt ja liikluskorralduslikult kokku
viidud olemasoleva situatsiooniga.
2.1 Projekteeritud teede põhinäitajad
Projekti koostamisel on teostatud järgmised põhilised tööd ja lahendused:
- Projekteeritud asfaldist juurdepääsuteed
- Projekteeritud mahasõitude rekonstrueerimised
- Projekteeritud 2 parklat, kus põhjapoolses parklas on 3 parkimiskohta ning
hoonete juures on parkla 32 parkimiskohaga millest üks on puuetega
inimese parkimiskoht
- Projekteeritud sillutiskivist ja asfaldist kõnniteed
- Projekteeritud ol.ol. katendite taastamised
- Projekteeritud mänguväljakute katendid
- Projekteeritud liikluskorraldus
- Teostatud vertikaalplaneerimine
2.1.1 Vertikaalplaneerimine
Asfaldist juurdepääsuteede pikikalded on 0,0 – 6,1 %.
Põikkalded üldjuhul 2,5 %.
Kõnniteede pikikalded on 0,0 – 6,7 %. Põikkalded
üldjuhul 2,0 %.
Parkla pikikalded 0,0 – 0,5 %. Põikkalded 0,7 – 2,0 %.
Korvpalliväljaku pikikalle 1,0 %. Põikkalle 0,0 %.
Staadioni jooksuraja pikikalle 0,0 – 1,0 %. Põikkalle 0 -
1,5. Üldjuhul 1,5 %.
2.1.2 Ristprofiil
Laiusparameetrid
Parkimiskohad 90 – kraadise nurga all laiusega 2,6 m ning pikkusega 4,5 - 5,0
m. Puuetega inimese pakimiskoht laiusega 3,6 m. Manööverdusala 7,5 m.
Parkimiskohad 0 – kraadise nurga all laiusega 2,5 m ning pikkusega 6,0 m.
Juurdepääsuteede laiused 3,5 – 5,5 m.
Kõnniteede min laius 1,5 m.
Tugevdatud tugipeenra laius äärekivide, metallääriste ja kõnniteede taga 0,25 m
ning sõidualadel äärekivi puudumisel 0,5 m. Tugipeenra põikkalle 4 %
väljapoole.
Kruuspeenra laius 0,5 m, põikkalle 4 % väljapoole.
2.2 Liikluskorraldus
Tähe tn mahasõit on mõeldud ainult sissesõitmiseks ehk kuni parklani tee on
ühesuunaline. Tartu tn-l parempoolne mahasõit on mõeldud sisse- ja väljasõiduks.
Vasakpoolset mahasõidu audtod üldjuhul ei kasutata.
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 5/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
2.2.1 Liiklusmärgid
Projektis on kasutatud järgmised liiklusmärgid:
0 gr märgid 575d
1 gr märgid 331
2.2.2 Teekattemärgistus
Parkimiskohtade markeeringuks on arvestatud värviga. Järgmistes projekti staadiumis
võib kaaluda asendada värviga markeeringu teise värviga murukivi vastu.
2.3 Katendikonstruktsioonid
Sõidutee katendi kihtide projekteerimisel on lähtutud Tallinna Linnavalitsuse 18.
september 2019 istungi protokolli nr 17 päevakorrapunkti nr 35 LISA 1 „Sillutiskivi,
asfalt- ja tsementbetoonkatenditega teede ja tänavate
tüüpkatendikonstruktsioonide projekteerimisele, rajamisele ja remondile
esitavad nõude“. Sõidutee katendikihid on valitud nimetatud juhendist vastavalt
katendi tüübile E5.
Tüüp 1
- AC 12 surf 70/100 h= 6 cm
- Killustik fr. 32/64 mm, Emin=170 MPa h=25 cm
- Keskliiv kt=98% (f7), Emin =65 MPa hmin=25 cm
- Olemasolev aluspinnas (vajadusel täitepinnas k t= 98%)
Tüüp 2
- AC 8 surf 70/100 h= 5 cm
- Ridakillustik fr. 4/64 mm, Emin=140 MPa h=20 cm
- Keskliiv kt=98% (f7), Emin =65 MPa hmin=20 cm
- Olemasolev aluspinnas (vajadusel täitepinnas k t= 98%)
Tüüp 3
- Sillutiskivi h= 6 cm
- Paigalduskiht (Liiva-tsemendi segu suhe 5:1) h= 3-4 cm
- Ridakillustik fr. 4/64 mm, Emin=140 MPa h=20 cm
- Keskliiv kt=98% (f7), Emin =65 MPa hmin=20 cm
- Olemasolev aluspinnas (vajadusel täitepinnas k t= 98%)
Tüüp 4
- Murukivi h= 8 või 10 cm
- Sängitusliiv või peeneteraline killustikmaterjal h= 3-4 cm
- Killustik fr. 32/64 mm, Emin=170 MPa h=25 cm
- Keskliiv kt=98% (f7), Emin =65 MPa hmin=25 cm
- Olemasolev aluspinnas (vajadusel täitepinnas k t= 98%)
Tüüp 5
- EPDM kummigraanulist kulumiskiht h= 1 cm
- SBR kummigraanulist elastsuskiht h= 2-11 cm *
- Ridakillustik fr. 4/64 mm, Emin=140 MPa h=20 cm
- Geotekstiil (eraldatav)
- Keskliiv kt=98% (f7), Emin =65 MPa hmin=20 cm
- Olemasolev aluspinnas (vajadusel täitepinnas k t= 98%)
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 6/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
* Vastavalt kukkumiskõrgusele
Tüüp 6
- AC 12 surf 70/100 h= 6 cm
- Killustik fr. 32/64 mm, Emin=170 MPa * h=25 cm
- Keskliiv kt=98% (f7), Emin =65 MPa * hmin=25 cm
- Kaevik
* Kihid rajada projekteeritud tehnovõrkude kohal astmelisusega 0,3 m.
Katendi materjalide minimaalsed kvaliteedinõuded
Kihi paksus, Juh Juhendi Positsioon Märkuse
cm end tabel või nr
(1)
punkt
Ridakillustikalus 20 „K“ 1 Nr 6 2
paekillustikust
fraktsioon 4/64
Killustikalus 25 „K“ 1 Nr 6 2
paekillustikust
fraktsioon
(kiilutud) 32/64
Märkused:
Ehituse ajal kasutada hanke ajal kehtivat TRAm, MTM, KLIM poolt
kinnitatud versioonid.
1. „A“ - EVS 901-3:2021 Asfaltsegud
Asfaldist katendikihid rajada vastavalt „Asfaldist katendikihtide ehitamise
juhis“. Asfaltsegude täitematerjalide miinimum kvaliteedinõuded vastavalt
EVS 901-3:2021. Sideaine sisalduse puhul järgida EVS 901-3:2021
segulehtedel toodud nõudeid. Ülejäänud nõuded vastavalt EVS-901
osadele 1 kuni 3.
Sõiduteedel arvestada tabelites toodud „Parkimisplatsid ja- alad“
nõuetega.
Kõnniteedel arvestada tabelites toodud „Jalgratta-, jalg- ja kõnniteed ning
õeualad“ nõuetega.
2. „K“- "Killustikust katendikihtide ehitamise juhis".
Teede killustikalused rajada ridakillustikust vastavalt Tee ehitamise
kvaliteedi nõuded. Elastsusmoodul määratakse LOADMAN või INSPECTOR
tüüpi seadmega. Mõne teise analoogse elastsusmooduli mõõteseadme
kasutamisel peavad selle lugemid olema eelnevalt võrreldud LOADMAN-
või INSPECTOR-tüüpi seadmega ja mõõtetulemused teisendatud
võrreldavaks.
3. Haljastatav maapind tuleb eelnevalt planeerida, vajadusel täita
ehitusobjektilt saadava pinnasega, katta kasvumulla kihiga (h=15 cm)
ning külvata muruseeme. Kasvumuld peab olema mineraalmuld (pH
6,5...7,0) huumuse sisaldusega min 3%, muld ei tohi sisaldada taimedele
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 7/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
kahjulikke jäätmeid, kive, killustikku jms. Muld tihendada nii, et ei tekiks
vajumisi ega veelohkusid (va immutusalad), ei tohi kasutada külmunud
pinnast. Olemasoleva ja rajatava haljasala piir ühtlustada ja tasandada
niitmiskõlbulikuks.
4. Betoonist äärekivid - kasutada sõiduteede ääres kasutamiseks toodetud
äärekive (15x29x80 cm), külmakindluse klass vähemalt Klass 3.
Toodang peab olema vastupidav teede talihooldes kasutatavatele kemikaal
idele. Paigaldusbetooni tugevusklass C16/20 sõidutee äärekividel.
Märgbetoon, tuleb paigaldada ühtlases reas betoonist sängituskihile.
Äärekivi paigaldamisel peab olema tagatud äärekivide vahel normidele
vastav vuukide vaheline laius. Äärekivi betoonaluse minimaalne paksus
peab olema 5 cm (loetuna äärekivi alt).
5. Sillutiskivide ja EPDM katendi juures kasutada metalläärist.
3. EHITAMINE
3.1 Üldandmed
Ehitustöödel peab töövõtja jälgima ja täitma kõiki nõudeid, mis on esitatud
Vabariigi Valitsuse 8. detsembri 1999.a. määruses nr. 377 “Töötervishoiu ja
tööohutuse nõuded ehituses”. Ehitustööde teostaja peab tagama ehitustööde
teostamise, ehitusplatsi kontrolli ja töötervishoiu ning tööohutuse nõuded
vastavalt eelmainitud määrusele nr. 377. Ehitustööde teostajal peavad olemas
olema määruses nõutud dokumendid.
Töövõtja peab ehitustööde alustamisest teatama Tööinspektsiooni kohalikule
asutusele vähemalt 3 päeva enne töödega alustamist. Ehitustööde ajal ei tohi
ehitusel viibida kõrvalisi isikuid ja ehitustööd ei tohi ohustada ehituse
mõjupiirkonnas viibijaid.
Töövõtja peab tagama, et ehitusfirma ja ehitusega seotud töötajad oleksid
kindlustatud. Töötajad peavad olema instrueeritud tööohutusalaselt ja olema
varustatud töötamiseks vajalike kaitsevahenditega.
Enne ehitustööde algust tuleb looduses kindlustada kõik olemasolevad
piirimärgid. Üldiselt tuleb ehitustööde käigus tagada kõikide olemasolevate
piirimärkide säilimine. Juhul kui see osutub võimatuks, tuleb sellest teavitada
maaomanikku ja pärast tööde lõpetamist taastada kõik tööde käigus hävinud
piirimärgid. Piirimärkide kahjustamisel on Töövõtjal kohustus need taastama.
Piirinaabreid tuleb teavitada ka kõikidest töödest, mis viiakse läbi nende maal
või kui ehitustegevus puudutab otseselt piirinaabri huve.
Enne ehitustööde algust on töövõtja kohustatud teavitama ja vajadusel kohale
kutsuma kõikide kommunikatsioonide valdajad. Samuti on töövõtja
kohustatud enne tööde algust teavitama kõiki teisi asjast huvitatud osapooli,
keda käesolev projekt puudutab (nt. maaomanikud, tööde teostamisel nendele
kuuluval maaüksusel).
Töövõtja peab tagama kõigi kooskõlastustes esitatud nõuete ja tingimuste
täitmise vastavalt projektlahendusele.
Tellija, Töövõtja, projekteerija ja omanikujärelevalve teatavad omal algatusel
viivitamatult avastatud vigadest, puudustest ja riskiteguritest
projektdokumentatsioonis ning nendest abinõudest, millega saab tööd
edendada ja paremate tulemuste saavutamist soodustada.
Töövõtja peab teavitama projekteerijat kõigist projektis leitud ebaselgustest
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 8/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
ning võimalikest vasturääkivustest enne, kui ta võtab vastu konkreetse
teostamise otsuse.
Kõik kooskõlastamata omaalgatuslikud projekti muudatused või
projektlahenduste eiramised on keelatud.
Eelpoolt toodu eiramisel on Töövõtja kohustatud kõik hilisemad
projektlahenduste eiramistest tulenevad parandused, vajalikud lisa- või
taastustööd teostama oma kuludega.
Ehitusperioodil vastutab töövõtja ka keskkonnakaitse (oma ehitustegevuse ja
muu sellest tuleneva piires) eest ehitusobjektil ja selle kõrval oleval alal
vastavalt Eesti Vabariigis kehtivatele seadustele ja nõuetele ning Tellija
poolsetele juhistele.
3.2 Ettevalmistustööd
Töövõtja peab kavandama ja paigaldama kaitsepiirded ja muud
kaitsekonstruktsioonid, mis on vajalikud tööplatsi piiramiseks ning
tööõnnetuste või varaliste kahjude vältimiseks.
Enne ehituse algust tuleb paigaldada ehitustsooni jäävatele puude tüvedele
puust kaitsekilbid.
3.2.1 Geodeetiline alusvõrk ja väljamärkimine
Mõõdistamine tugineb koordinaatidega L-EST97 süsteemis ja kõrgusega
EH2000 süsteemis.
3.3 Liikluskorraldus ehituse ajal
Ajutisel liikluskorraldusel juhinduda majandus- ja taristuministri 13.07.2018
nr 43 määrusest „Nõuded ajutisele liikluskorraldusele“.
Enne töödega alustamist tuleb vajadusel koostada „Ajutise liikluskorralduse
projekt“, mis tuleb kooskõlastada Tellijaga ja kohaliku omavalitsuse ehitus- ja
kommunaalosakonnaga.
3.4 Olemasoleva katendi likvideerimine
Eemaldatav materjal kuulub nende valdajale ja tuleb Töövõtja kulul
transportida Tellija poolt määratud ladustustamiskohta. Hoiuplatsil tuleb
materjal hoida korrektselt vallitatuna, hoiuplasti korrashoiu eest vastutab
Töövõtja. Taaskasutatavaks materjaliks on freesasfalt.
3.5 Tee ehitus
3.5.1 Mullatööd
Mulde laienduste laiuses tuleb koorida kasvupinnas
Seejärel tuleb profileerida alus kattega paralleelseks aluseks ja eemaldada
seejuures kogu olemasolev peenar, tihendada muldkeha. Seejärel paigaldada
keskliiva kiht, tihendada ning profileerida.
Kasvupinnas koorida eraldi ja kasutada samal ehitusel haljastamiseks või üle
anda vastavat jäätmeluba omavale isikule. Välistada tuleb kasvupinnase
reostamine ja ülemäärane tihendamine. Väljakaevatud pinnase kasutamine
väljaspool ehitusobjekti kooskõlastada riigi Keskkonnaametiga.
Muldesse paigaldatav materjali peab olema orgaanikavaba ja tihendatav.
Mulde pealne tuleb planeerida paralleelselt katte projekteeritud
vertikaalplaneerimisega. Konstruktsiooni alune pind tuleb tihendada.
Enne mulde ja katendi ehitustöid tuleb teostada ettenähtud
kommunikatsioonide kaitsemeetmed.
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 9/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
3.5.2 Muldkeha ja keskliiva kiht
Teel tuleb eemaldada mulde osas materjal projekteeritud konstruktsiooni
põhjani. Ehitamisel tuleb jälgida, et olemasolev või rajatud mulle ning alus
oleksid tihendatud (tihendustegur minimaalselt 0,98 töökihi ülakihis ja 0,96
töökihi alakihis) ja planeeritud põikkaldega.
Muldkeha töötsoonis (kuni katte pinnast 1,5 m) tuleb kasutada täiteks liiva,
kus peenosise sisaldus on <7%. Töökihist allapoole mineraalmaterjali
paigaldatava materjali orgaanikasisaldusega peab olema <5%. Muldkehade
ehitamisel tuleb juhinduda „Muldkeha ja dreenkihi projekteerimise, ehitamise
ja remondi juhises“ ja „Muldkeha remondi projekteerimise juhisest“ (va.
materjali nõuded). Mulde laienduste alt tuleb koorida kasvupinnas. Mulde
pealne tuleb planeerida ja konstruktsiooni alune pind tuleb tihendada. Mulde
peale tuleb rajada keskliiva kiht. Enne kaevetööde alustamist on vajalik
trassivaldajate teavitamine Töövõtja poolt ja vajalike kaevelubade hankimine.
Kaevetööde läbiviimisel arvestada pinnase kvaliteeti ja kaevikute sügavust,
olemasolevaid konstruktsioone ja koormatust ning vee ja transpordi mõjul
tekkivaid ohtusid. Töövõtja kindlustab kaeviku määral, mis tagab ohutu tööde
korraldamise. Kaeviku paiknemine ja sügavus fikseeritakse töö ajal tehtavate
kontrollmõõdistuste abil enne aluskihi tegemist. Tuleb vältida liigset kaevamist
nii laiusesse kui ka sügavusse. Valmiskaevatud kaevikust eemaldatakse
lahtised kivid. Töövõtja peab otsima ehituseks sobimatu pinnase
ladustamiseks sobiva koha.
Enne katendi aluskihi paigaldamist teostatakse vajadusel
olemasolevate kommunikatsioonide ümberehitus.
Olemasolevatelt haljasaladelt saadav kasvumuld sõelutakse, viiakse
vastavusse haljastamisel kasutatavate nõuetega ja kasutatakse teede äärsete
alade haljastamisel (h=15 cm).
3.5.3 Aluse ehitus
Profileeritud ja tihendatud olemasolevale aluspinnasele rajatakse vastavalt
projektlahendusele katendi alumised kihid keskliivast.
Killustikukihtide rajamisel tuleb lähtuda „Killustikust katendikihtide ehitamise
juhisest 26.01.2022“.
Piki- ja põiksuunas profileeritud ja tihendatud aluskihile paigaldatakse
vastavalt tüüplõigetes antud fraktsioonidega ja paksustega killustikkihid.
3.5.4 Katendi pealiskihtide ehitus
Kõikide asfaldist katendikihtide rajamisel tuleb järgida „Asfaldist katendikihtide
ehitamise juhendit“. Kõikide asfaltbetoonsegude seguretsept ja kasutatava
asfaltsegu omadused peavad vastama standardile EVS 901-3, arvestades
projektis ja „Asfaldist katendikihtide ehitamise juhises“ toodud lisanõudeid.
Kõik pikivuugid tuleb teostada kuumvuukidena. Ühendamisel põhitee kattega
kasutatakse pikivuugi kruntimiseks ülemisel kihil bituumen liimi TOK-PLAST
või sellega sarnaste omadustega liimi, mis kantakse pikivuugile spetsiaalse
masinaga. Vuugiliimi arvestuslik kulunorm peab vastama tootja poolsetele
nõuetele (nt Tok-plasti puhul on 20g/m paigaldatava kihi paksuse ühe
sentimeetri kohta).
3.5.5 Sillutiskivi paigaldus
Sillutiskivid laotada tihedalt üksteise kõrvale. Jälgida tuleb, et kiviread
jookseksid võimalikult otse, vajadusel kasutatakse nööri. Kivide ladumisel
ollakse ise äsjapaigaldatud tänavakivide peal, et mitte rikkuda siledat
paigalduskihi. Iga 6 m tagant tuleb lisada kummilint. Peale ladumise
lõpetamist tuleb lõigata parajaks äärmised kivid. Pärast kivide ladumist
laotatakse platsile kuiv liiv ja harjatatakse kivide vahedesse. Peale seda tuleb
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 10/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
kivide peale sõita 90-100 kg kaaluva pinnasetihendajaga, suunaga üks kord
ühtepidi ja seejärel teistpidi. Peale kivide tihendamist on kivi vuugivahed taas
pooltühjad ning tuleb uuesti liivatada. Kõige lõpuks puhastada plats liigsest
liivast.
3.5.6 EPDM katendi paigaldus
EPDM katendi paigaldamisel arvestada tootja juhendiga, kuid üldjuhul katendi
paigaldusel peab aluspind olema kuiv, ei tohi olla sademeid, sobiv
õhutemperatuur vahemikus 10 – 40 oC . Materjali kuivamise ajal ei tohi
õhutemperatuur langeda alla + 5 oC.
Pealmise EPDM kihi paksus on 1 cm, et tagada vastupidavus kulumisele ja
rasketele ilmastikutingimustele ning vähendada ekspluatatsioonikulusid
tulevikus. SBR kihi paksus sõltub mänguvahendi kukkumiskõrgusest.
3.6 Liikluskorraldusvahendid
Liiklusmärkidele, postidele ja tarvikutele on nõuded esitatud Teetööde
tehnilistes kirjeldustes.
Teekattemärgistuse teostamisel juhinduda EVS 614 juhendi nõuetest.
Teemärgised on ette nähtud teha värviga.
Tee valdaja poolt kasutuskõlbmatuks või mitte vajalikuks tunnistatud
elemendid tuleb utiliseerida.
Märkide valmistamisel kasutada liiklusmärkide suurusgrupp 0 ja 1.
Liiklusmärkidel kasutada kilet valguspeegeldavuse klassiga R2. Liiklusmärgid
peavad olema tsingitud plekist alustel, tekstilised märgid alumiiniumalustel.
Liiklusmärgi alumiiniumalus peab olema vähemalt paksusega 1,85 mm.
Liiklusmärkide tagumine külg peab olema kaetud halli värviga.
Liiklusmärkide postid peavad olema kuumtsingitud terastorud, posti läbimõõt
60mm. Ehitaja peab arvestama posti pikkuse valikul postile paigaldatavate
liiklusmärkide arvuga.
Olemasolevad liiklusmärgid, mis lähevad vastuollu projekteeritud
liikluskorraldusega võetakse maha.
Liiklusmärgid peavad vastama EVS 613 toodud nõuetele. Kõik liiklusmärgid,
liiklusmärkide postid ja kinnitustarvikud peavad vastama standardile EVS-EN
12899 ning vastu pidama samas standardis kirjeldatud koormusklassidele ja
osavaruteguritele.
Märkide paigaldamisel arvestada nende nähtavusega, vajadusel korrigeerida
paigalduskoht standardiga EVS 613:2001/A2:2016 antud piires.
3.7 Keskkonnakaitse
Ehituse Töövõtja vastutab ehitusperioodil keskkonnakaitse eest ehitusplatsil ja
sellega vahetult piirnevail aladel Eesti Vabariigis kehtivaile seadustele ja
nõuetele ning Tellija poolt esitatud juhistele vastavalt.
Tähelepanu tuleb pöörata ehitustöödel tekkivate jäätmete käitlusele. Jäätmed
käideldakse vastavalt kehtivale korrale. Ehitusjäätmete käitlemise eest
vastutab jäätmete valdaja. Kaevetöödel kaevandatavad pinnased tuleb
utiliseerida vastavalt jäätmekäitlusseadusele.
Ohtlikud jäätmed tuleb koguda muudest jäätmetest eraldi ning üle anda
ohtlike jäätmete käitlemise litsentsi omavatele ettevõtetele.
Kogu ehitusperioodil peab ette nägema tolmutõrjeks veega kastmise.
Ehitusmasina juhil peab olema kütuse või õlilekete likvideerimise oskus.
Vajalik on ehitustehnika regulaarne ülevaatus ja hooldus vähendamaks lekete
tekkimise võimalust.
Masinaid/ mehhanisme tuleb hooldada korrapäraselt, et vältida juhuslikke
lekkeid ja reostusohtu. Õlide, kütuste jm sarnase käitlemisel tuleb vältida
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 11/12
AS Infragate Eesti töö MS6/132-25
MUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, MUSTVEE
HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE
EHITAMINE
nende lekkimist ning valgumist pinnasesse, pinna- ja põhjavette, samuti
jääkide kontrollimatut kõrvaldamist. Vajadusel kasutatakse vastavaid vanne
või paake.
Kui masinal/ mehhanismil avastatakse õli/ kütuse leke, tuleb võtta kasutusele
meetmed vältimaks pinnasereostust. Juba reostatud pinnas tuleb eemaldada
ja viia saastatud pinnast vastuvõtvale ettevõttele. Seda ei või kasutada
objektil täiteks ega segada muu jääkpinnasega. Olenevalt reostuse ulatusest
tuleb informeerida Keskkonnaametit.
Ehitustööde organiseerimisel arvestada, et raskete veokite liiklemine puude
juurtel või ehitusmaterjalide ladustamine puude alla tihendab pinnast ja
puude ainevahetus on häiritud. Seepärast ei tohi puude alla võra ulatuses
kuhjata mulda, ehitusmaterjali jne.
4. TEEDE KASUTAMISE JA HOOLDUSE JUHEND
Teede ehitusjärgne kasutamine ja hooldus toimub Eesti Vabariigis kehtivatele
õigusaktidele. Hoolduse puhul tuleb lähtuda järgmistest kehtivatest Majandus-
ja Kommunikatsiooniministri määrustest:
1. Tee ehitamise kvaliteedi nõuded.
2. Tee seisundinõuded 14.07.2015.a määrus nr. 92.
Viimati mainitud õigusaktid on kohustuslikud kõikidele avalike teede
omanikele ja hooldajatele ning need tagavad nõutava tee korrashoiu.
Käesolevas projektis ei ole kasutatud eri hoolde- ja ekspluatatsiooninõudeid
vajavaid lahendusi.
Kui liivavarude täiendamine toimub liigniiskel perioodil, siis murukattel on
soovituslik kasutada kaitseplaate.
JOONISED
- MS6_EP_TL-4-01_AsukohaSkeem
- MS6_EP_TL-4-02_TeedeAsendiplaan
- MS6_EP_TL-4-03_Vertikaalplaneering
Tallinn 07.2025
MS6_EP_TL-3-01_Seletuskiri
Koostas ins. R.Sokmann leht 12/12
Mi
DN100/225/225
nia
r en
a-
Su
Sta
ur
ol.
tur
ol.
ad
n
im
ion
isp
üra
Ko
- re
mi
Lipud
id
rv
ko
pa
nst
ll
rue
Paviljon
eri
tav
Liivakast Kiik
Kiik 3-6 aastased
Liivakast
He
kk
Kiik
Las Mä
1-3 aastased
Liivakast
teanguhoo
Võ
ia v kokku
rk a
Turnimine
OL.OLEV SIDE LIITUMISPUNKT
ed
mä1025m
Liumägi
ng ² - min
uh 17m²/
oo laps
Lasteaed - 3. osa - 1K
v
itud soojussõlmega
Ühenduskoht (ÜK1) projekteer Pallimänguala
Kool - 1. osa - ol.ol. hoone 2K Kool - 1. osa
0,00=35,03 abs. Riietusruumid, Ratta ja jooksurada
Jalgrattad
varjend - 1K
P3
Hariduskeskus - 2. osa - 2K
P9
P8 + 1
Ø160 SN8
L=1.7m
i=0.008
34.65
33.10
33.17 P3
ELEKTRIVÕRGU LIITUMISPUNKT
Prügi
N
P8
P3
Külmaseadmed 3tk
AS INFRAGATE EESTI TÖÖ NR MS6/132-25 MÄRKUSED:
TEEDE TINGMÄRGID: 1. Koordinaadid L-EST 97 süsteemis, kõrgused EH2000 süsteemis.
Projekteeritud katte serv 2. Geodeetilise alusplaani koostaja OÜ Inseneribüroo REIB,
Projekteeritud metallääris (LineFix või muu sarnane) töö nr. TT-7172T, kuupäev 04.2025 ja töö nr TT-6736T, kuupäev 11.2023
Projekteeritud sõidutee asfalt (Tüüp 1)
Projekteeritud kõnnitee asfalt (Tüüp 2)
Projekteeritud kõnnitee sillutiskivi (Tüüp 3) Tellija Töö nr.
INFRAGATE EESTI AS Mustvee Vallavalitsus
Projekteeritud murukivi (Tüüp 4)
Projekteeritud EPDM katend
(Tüüp 5)
Projekteeritud kruusapeenar (positsioon nr 6) MÄEALUSE 2/3 MS6/132-25
Projekteeritud betoonplaadi taaspaigaldus (vajadusel uuega asendamine) 12618 TALLINN
Projekteeritud haljastus
tel. 626 7777
Töö nimetusMUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, Staadium
Projekteeritud nõlv
Projekteeritud sõidutee äärekivi h=7 cm e-post:
[email protected] MUSTVEE HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE EHITAMINE EP
Projekteeritud sõidutee äärekivi h=3 cm
www.infragate.ee Objekt
911
Projekteeritud sõidutee äärekivi h=0 cm
Projekteeritud teemärgistus (värv/termovaluplastik) MTR EP10845129-0001 Tartu tn 11, Mustvee linn, Mustvee vald, Kuupäev
Projekteeritud kummist parkimistõkend
(h=10 cm, b=15 cm, l=182 cm)
Jõgeva maakond 21.07.2025
Projekteeritud parkimiskohtade arv
P8
Projekteeritud liiklusmärgi post Projektijuht L.Mürk Leht Mõõtkava
ARHITEKTUURI
Kinnistu piir
TINGMÄRGID:
SOOJUSVARUSTUSE TINGMÄRGID:
Projekteerija R.Sokmann Tehnovõrkude koondplaan 1:500
Uus ehitatav hoone/räästas, varikatus
Projekteeritud maa-alune soojustorustik Lehe nr.
Projekteerija
Rekonstrueeritav hoone/ räästas, varikatus
PV paneelide paigaldusala
Likvideeritav soojustorustik
Projekteerija AS-1-01
IGE
KNR8
RS
09.12.2016
Liiklusmärgid paigaldada hoone seina külge
Mi
3.0
nia
3.0
r en
a-
Su
891b (I gr)
Sta
ur
331 (I gr)
ol.
territooriumi
valdaja loal
Välja arvatud
tur
R5.7
ol.
ad
nim
ion
isp
üra
Ko
- re
m
R15.5
Lipud
iid
rv
R15.5
ko
R3
pa
nst
ll
1.5
R30
rue
Paviljon
eri
tav
3.0
3.5 Liivakast Kiik
Kiik 3-6 aastased
R7
Liivakast
He
kk
Kiik
Las Mä
1-3 aastased
Liivakast
teanguhoo
R5
Võ
ia v kokku
rka
Turnimine 2.0
7.4
de
mä1025m
R1
R1
Liumägi
1.2
ng ² - min
uh 17m²/
1.5
13.0
oo laps
8.0
Lasteaed - 3. osa - 1K
v
R1.5
R15 Pallimänguala R1
Kool - 1. osa - ol.ol. hoone 2K Kool - 1. osa R1
1.5
R10
1.
1.5
Riietusruumid, R6
7
Ratta ja jooksurada
0,00=35,03 abs.
Jalgrattad
R1.5
1.2
R1
2.0
varjend - 1K
R5
2.0
R2
R30
R20
6.0
2.5 3.5
R3 R3
R26.5
2.0
R25
P3
1.4
R3
R3
R3
3.5
2.0
0.5
R33.5
3.6
575d (I gr)
Hariduskeskus - 2. osa - 2K
(Kinnistada proj. valgustusposti külge)
2.6
2.0 5.0 7.5 5.0
P9
0.5
331 (I gr)
2.6
P8 + 1
1.0
2.85 2.6
5.0
2.6
P3
2.0
1.8
Prügi
7.5
R0.5
6.0
R1
5.5
P8
N
P3
2.6
4.5
6.0
2.5
Külmaseadmed 3tk
AS INFRAGATE EESTI TÖÖ NR MS6/132-25
TEEDE TINGMÄRGID: MÄRKUSED:
Projekteeritud katte serv 1. Koordinaadid L-EST 97 süsteemis, kõrgused EH2000 süsteemis.
Projekteeritud metallääris (LineFix või muu sarnane) 2. Geodeetilise alusplaani koostaja OÜ Inseneribüroo REIB,
Projekteeritud sõidutee asfalt (Tüüp 1)
Projekteeritud kõnnitee asfalt (Tüüp 2) töö nr. TT-7172T, kuupäev 04.2025 ja töö nr TT-6736T, kuupäev 11.2023
Projekteeritud kõnnitee sillutiskivi (Tüüp 3)
Projekteeritud murukivi (Tüüp 4)
Projekteeritud EPDM katend
(Tüüp 5)
Tellija Töö nr.
Projekteeritud sõidutee asfaldi taastamine
(Tüüp 6)
INFRAGATE EESTI AS Mustvee Vallavalitsus
Projekteeritud kruusapeenar (positsioon nr 6)
Projekteeritud betoonplaadi taaspaigaldus (vajadusel uuega asendamine)
Projekteeritud haljastus
Projekteeritud nõlv
MÄEALUSE 2/3 MS6/132-25
Projekteeritud sõidutee äärekivi h=7 cm 12618 TALLINN
Projekteeritud sõidutee äärekivi h=3 cm
Projekteeritud sõidutee äärekivi h=0 cm tel. 626 7777
Töö nimetusMUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, Staadium
911
Projekteeritud teemärgistus (värv/termovaluplastik)
Projekteeritud kummist parkimistõkend e-post:
[email protected] MUSTVEE HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE EHITAMINE EP
(h=10 cm, b=15 cm, l=182 cm)
www.infragate.ee Objekt
P8 Projekteeritud parkimiskohtade arv
Projekteeritud liiklusmärgi post
MTR EP10845129-0001 Tartu tn 11, Mustvee linn, Mustvee vald, Kuupäev
Kinnistu piir
Jõgeva maakond 21.07.2025
ARHITEKTUURI
TINGMÄRGID:
Uus ehitatav hoone/räästas, varikatus Projektijuht L.Mürk Leht Mõõtkava
Rekonstrueeritav hoone/ räästas, varikatus
Projekteerija R.Sokmann Teede asendiplaan 1:500
PV paneelide paigaldusala
Projekteerija Lehe nr.
Projekteerija TL-4-02
IGE
KNR8
RS
09.12.2016
Mi
34.10
34 34.3 34. 34.
.30 0 0 10 20
.20 0 34.2 34.1 20 34.
nia
34 34.20
34.10
r en
34.00
a-
Su
Sta
ur
ol.
34
tur
.00 34.1
ol.
ad
nim
34.20
ion
34.20
34.10
34.20
0
isp
34.30
34.10
34.0
34.40
34.00
üra
34.40
34.10
34.
Ko
- re
34.30
0
m
34. 00
Lipud
iid
10 34.00 33.90 33.80
rv
ko
pa
34.00 34.00
34
nst
0
33.9
ll
.00
34.00
rue
34.10
0 0
33.9
34.20
.8
34.30
33.90 33
Paviljon
eri
0
0
34 0
.
2
34.00 33.9
34.
0
34
34.10 34.20
tav
34
.10
0
.2 34.10
34.30 Kiik
34.1
0 Liivakast
34.00
34
.3
Kiik 3-6 aastased
0
34.40 34.4
.10
Liivakast
34
He
0 34.20
kk
.40
34
34. Kiik
Las Mä
0 34 50 4.5
0 0 .4 34.30
.4 .40 3 34 1-3 aastased
34
Liivakast
teanguhoo
34.40 34.30 34.30
50 34.10
34.
Võ
ia v kokku
rka
60 34.40 Turnimine
0 34.
34
e
34
.5
d
mä1025m
34.10
.
34
50
34.50
.30
34 Liumägi
70
ng ² - min
.6 34.
34.20
0 0
.6 34.60
34.70
uh 17m²/
34 34
.7
0 34.20
34.
oo laps
35.30
Lasteaed - 3. osa - 1K
34.40
34.80
40
34.80
v
34.70
Pallimänguala
Kool - 1. osa - ol.ol. hoone 2K Kool - 1. osa 34.20
60
0,00=35,03 abs. Riietusruumid, Ratta ja jooksurada
34.30
Jalgrattad
34.
34.10
34.80 34.30
.20
0
.8
.30
varjend - 1K
34.50
34.
34
34
34.80
34
34.20
50
34.40
.60
34.30
0
70
60
34.7 34. 34.30
.7
.70 34.
34
34
0 34. 70
34
34.30
34.
0
34
34.80
60
34.90
34.40
35.00
.60
34.2
34. P3
50
35
34.20
0
0
0
34.5 34.5 34.30
.4
.00
34.20
.5
70 0 0 34.
34
34
. .5 5 0
34 34 34.40 34.40
34.30
34.6
Hariduskeskus - 2. osa - 2K
0
80
34.
P9
34.40
34.30
34.50
34.60
34.70
P8 + 1
34.7
0
0
34.
8
40
34.
34.40
P3
0
35.00 35.00
.9
34.80
34.90
Prügi
34
34.50
34.60
34.50
34.
0
34.90
.7
70
0
34
.8
N
P8
34
34 P3
.6 34.80
34.50
0 .60
34
34.
50
34.4
0
Külmaseadmed 3tk
AS INFRAGATE EESTI TÖÖ NR MS6/132-25
TEEDE TINGMÄRGID: MÄRKUSED:
Projekteeritud katte serv 1. Koordinaadid L-EST 97 süsteemis, kõrgused EH2000 süsteemis.
Projekteeritud metallääris (LineFix või muu sarnane) 2. Geodeetilise alusplaani koostaja OÜ Inseneribüroo REIB,
Projekteeritud sõidutee asfalt (Tüüp 1)
Projekteeritud kõnnitee asfalt (Tüüp 2) töö nr. TT-7172T, kuupäev 04.2025 ja töö nr TT-6736T, kuupäev 11.2023
Projekteeritud kõnnitee sillutiskivi (Tüüp 3)
Projekteeritud murukivi (Tüüp 4)
Projekteeritud EPDM katend
(Tüüp 5)
Tellija Töö nr.
Projekteeritud sõidutee asfaldi taastamine
(Tüüp 6)
INFRAGATE EESTI AS Mustvee Vallavalitsus
Projekteeritud kruusapeenar (positsioon nr 6)
Projekteeritud betoonplaadi taaspaigaldus (vajadusel uuega asendamine)
Projekteeritud haljastus
Projekteeritud nõlv
MÄEALUSE 2/3 MS6/132-25
Projekteeritud sõidutee äärekivi h=7 cm 12618 TALLINN
Projekteeritud sõidutee äärekivi h=3 cm
Projekteeritud sõidutee äärekivi h=0 cm tel. 626 7777
Töö nimetusMUSTVEE KOOLI HOONE ENERGIATÕHUSAKS MUUTMINE, Staadium
911
Projekteeritud teemärgistus (värv/termovaluplastik)
Projekteeritud kummist parkimistõkend e-post:
[email protected] MUSTVEE HARIDUSKESKUSE JA LASTEAIA LIGINULLENERGIAHOONETE EHITAMINE EP
(h=10 cm, b=15 cm, l=182 cm)
www.infragate.ee Objekt
P8 Projekteeritud parkimiskohtade arv
Projekteeritud liiklusmärgi post
MTR EP10845129-0001 Tartu tn 11, Mustvee linn, Mustvee vald, Kuupäev
5.20 Projekteeritud vertikaal kõrgusarvuga
Kinnistu piir Jõgeva maakond 21.07.2025
ARHITEKTUURI
TINGMÄRGID:
Projektijuht L.Mürk Leht Mõõtkava
Uus ehitatav hoone/räästas, varikatus
Rekonstrueeritav hoone/ räästas, varikatus Projekteerija R.Sokmann Vertikaalplaneering 1:500
PV paneelide paigaldusala Lehe nr.
Projekteerija
Projekteerija TL-4-03
IGE
KNR8
RS
09.12.2016
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
SISUKORD
JOONISTE NIMEKIRI ...............................................................................................................................4
1. Üldosa ..............................................................................................................................................5
1.1. Projekteerimistöö piiritlus .............................................................................................................5
1.2. Alusdokumendid...........................................................................................................................5
1.2.1. Ehitusuuringud .........................................................................................................................5
1.2.2. Kasutatavad normid .................................................................................................................5
2. Majandus-joogivee süsteem.............................................................................................................5
2.1. Veevarustuse vooluhulgad ...........................................................................................................5
2.2. Veevarustuse allikas ....................................................................................................................5
2.3. Veemõõdusõlm ............................................................................................................................5
2.4. Soojavee süsteem .......................................................................................................................6
3. Veetorustike paigaldus .....................................................................................................................6
3.1. Torustiku materjal.........................................................................................................................6
3.2. Armatuur ......................................................................................................................................6
3.3. Toruliitmikud ja ühendused ..........................................................................................................7
3.4. Läbiminekud tuletõkkesektsioonidest ..........................................................................................7
3.5. Toestus ja kinnitused ...................................................................................................................7
3.6. Torustike isoleerimine ..................................................................................................................7
3.7. Hüdraulilised katsetused ..............................................................................................................7
4. Tuletõrjeveevarustus ........................................................................................................................8
4.1. Tuletõrjevee välisvõrgud ..............................................................................................................8
4.2. Tulekaitse .....................................................................................................................................8
5. Reovee kanalisatsioon .....................................................................................................................8
5.1. Arvutuslik vooluhulk .....................................................................................................................8
5.2. Eelvool .........................................................................................................................................8
5.3. Puhastusseadmed .......................................................................................................................8
5.4. Pumpla .........................................................................................................................................8
6. Sajuveekanalisatsioon ......................................................................................................................8
6.1. Arvutuslik vooluhulk .....................................................................................................................8
6.2. Puhastusseadmed .......................................................................................................................9
6.3. Pumpla .........................................................................................................................................9
7. Kanalisatsioonitorustike paigaldus ...................................................................................................9
7.1. Torustike materjalid ......................................................................................................................9
7.2. Torustikud ja armatuur .................................................................................................................9
7.3. Toestus ja kinnitused ...................................................................................................................9
7.4. Torustike isoleerimine ..................................................................................................................9
7.5. Läbiminekud tuletõkkesektsioonidest ..........................................................................................9
7.6. Hüdraulilised katsetused ..............................................................................................................9
8. Drenaaž ............................................................................................................................................9
9. Keskkonnakaitsemeetmed .............................................................................................................10
9.1. Ehitusjäätmed ............................................................................................................................10
9.2. Haljastuse taastamine ................................................................................................................10
10. Tehnosüsteemide eluiga ............................................................................................................10
11. Kvaliteedi- ja kontrollinõude .......................................................................................................10
11.1. Üldnõuded .............................................................................................................................10
11.1.1. Seadused ja määrused ..........................................................................................................10
11.1.2. Muudatused ...........................................................................................................................11
11.1.3. Kvaliteedi tagamise ja kasutuselevõtu üldnõuded .................................................................11
11.1.4. Tihedus- ja surveproovid .......................................................................................................11
11.1.5. Seadmete ja paigalduse kontrollid .........................................................................................11
11.1.6. Üleandmis- ja kasutus dokumendid .......................................................................................11
11.1.7. Garantiiperioodi meetmed .....................................................................................................12
11.2. Tööde teostamine ..................................................................................................................12
11.2.1. Toed ja kinnitused ..................................................................................................................12
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 2 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
11.2.2. Elektriseadmed ......................................................................................................................12
11.2.3. Seadmete ja torustike märkimine ..........................................................................................12
11.2.4. Akustilised ja vibratsioonivastased nõuded ...........................................................................12
11.3. Hüdraulilised katsetused .......................................................................................................13
11.3.1. Veetorustiku hüdraulilised katsetused ...................................................................................13
11.3.2. Kanalisatsioonivõrgu paigaldus ja hooldus ...........................................................................13
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 3 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
JOONISTE NIMEKIRI
JOONISE JOONISE NIMI KUUPÄEV MÕÕTKAVA
NR
1. KORRUS
VK-1 18.07.2025 1:100
VEESISEND JA PEAVEEMÕÕDUSÕLM
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 4 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
1. Üldosa
1.1. Projekteerimistöö piiritlus
Antud eelprojekt on koostatud „Mustvee Kooli hoone energiatõhusaks muutmine, Mustvee
Hariduskeskuse ja lasteaia liginullenergiahoonete ehitamine“ projekteerimiseks aadressile Tartu tn 11,
Mustvee linnas. Projekt käsitleb põhikooli lahendust, hariduskeskuse lahendust ja uue lasteaia rajamist.
Põhikooli osa koosneb olemasolevast 1938a valminud koolihoonest ning selle juurdeehitustest, kus
asuvad riietusruumid ning tugispetsialistide kabinetid. Riietusruumide osa on projekteeritud S1 klassi
varjendina. Tartu tänava äärde rajatakse uus hariduskeskuse maht, mille asukohal asub hetkel
lammutamisele määratud hoone. Uus hariduskeskus ja olemasolev kooli maht ühendatakse omavahel
galeriiga, kuhu tekib ka uus hoone peasissepääs. Ka kooli juurdeehituse kohal asub praegu olemasolev
hoone, mis on ette nähtud lammutada.
Lasteaia osa on üleni uus maht, mis on kooli ühekorruselise juurdeehitusega galerii kaudu ja
varikatustega ühenduses. Lasteaed on ühekorruseline ja 3 rühmaline.
Lisaks lahendatakse kogu kinnistu teed, platsid, parkimine, staadioni rekonstrueerimine ning lasteaia
mängualad koos kinnistu vertikaalplaneerimisega.
Skeem uute hoonetega ja nende asetusega. Punase punktiiriga on näidatud lammutamisele määratud
hooneosad.
1.2. Alusdokumendid
1.2.1. Ehitusuuringud
Käesoleva projektlahendusega seonduvalt on nimetatud kinnistule teostatud geodeetilised mõõdistustööd
ja kaevude uuring. Olemasolevale hoonele on koostatud energiaaudit.
1.2.2. Kasutatavad normid
Projekteerimisel on arvestatud järgmiste standarditega ja nõuetega:
• EVS 921:2022 Veevarustuse välisvõrk;
• EVS 835:2022 Hoone veevärk;
• EVS 846:2021 Hoone kanalisatsioon;
• EVS 848:2021 Väliskanalisatsioonivõrk;
• EVS 812-6:2012 Ehitiste tuleohutus. Osa 6: Tuletõrje veevarustus;
• EVS-EN 1610:2015 Äravoolu- ja kanalisatsioonitorustike ehitamine ja katsetamine.
2. Majandus-joogivee süsteem
2.1. Veevarustuse vooluhulgad
Arvutuslikud majandus-joogivee vooluhulgad:
Juurdeehitus
• sekundiline 0,98 l/s (soe vesi 0,87 l/s);
• tunni 2,6 m³/h;
• ööpäevane 9,5 m³/d.
2.2. Veevarustuse allikas
Majandus-joogivesi saadakse Tartu tänava ühisveetorustikust läbi olemasolevate veeühenduste.
Käesoleva tööga olemasolevaid veeühendusi (liitumispunkte) ei muudeta.
2.3. Veemõõdusõlm
Kinnistu peaveemõõtja on projekteeritud hariduskeskuse osas koristuskeskuse ruumis. Kasutatud on
sisemise tagasilöögiklapiga DN20, Qn=2,5 m3/h kaugloetav külmaveearvestit (Kamstrup). Arvesti
paigaldada maandatud kandurile, kahe sulgventiili vahele, paralleelselt seinaga. Arvestile peab eelnema
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 5 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
vähemalt viie toru läbimõõdu ning järgnema vähemalt kolme toru läbimõõdu pikkune sirge torulõik. Kõik
liitmikud, enne veemõõtjat peavad olema keevisliitmikud.
2.4. Soojavee süsteem
Hoonete soe vesi saadakse projekteeritud soojussõlmest (KV-osa). Sooja veega varustatakse kõiki
sanseadmeid, v.a. klosetipotid.
Hoonele on ettenähtud soojavee ringlussüsteem. Tagastuva vee temperatuuri (+50°C).
Soojaveevarustuse tsirkulatsiooniks on ette nähtud tsirkulatsioonipump, mis paigaldatakse soojussõlme.
Soojavee tsirkulatsioonitorustike haruühendustele paigaldada termostaatilised tasakaalustusventiilid
sulgemisfunktsiooniga.
Segistid, mis on mõeldud kasutamiseks laste poolt on varustatud temperatuuri piirajaga (kasutatav vee
temperatuur on vahemikus 35-40 °C).
3. Veetorustike paigaldus
Magistraaltorustikud paiknevad lagede all ja ühendustorud sanitaarseadmetega paiknevad
seinakonstruktsioonis.
Olulised vett tarbivad seadmed paiknevad san.ruumides.
Veetorustik paigaldada vastavalt toru tootja nõuetele. Paigaldamisel järgida RYL 2002 nõudeid.
Enne paigaldamist tuleb torud puhastada ja toru katkestamisel tekkinud kraasid eemaldada nii, et toru
läbilõikepind jääks igas kohas toru vabapinna suuruseks. Torustikes tuleb sobivatesse kohtadesse
paigaldada lahtikäivad jätkud nii, et kõiki seadmeid, ventiile jms. saab eemaldada ilma torusid
katkestamata. Torud ei või kokku puutuda söövitavate ainetega. Seintest ja põrandast läbiminekul ei või
torud puutuda vahetult kokku konstruktsiooniga, selleks varustada läbimineku avad kaitsehülsiga.
Torustike paigaldamisel lae alla arvestada teiste torustike (ventilatsioon, küte, kanalisatsioon) ja
kaabliredelite asukohaga. Kroomitud torude ühendamisel kasutatakse kroomitud osi.
Põrandasse paigaldatavad külmaveetorud tuleb paigutada isolatsioonikihi alla ja soojaveetorud
paigaldada isolatsioonikihi peale, armatuurvõrgu alla.
3.1. Torustiku materjal
Majandus- ja joogivee süsteemi tuleb kasutada alupex kihtsein-plasttorusid Ø16x2.0÷Ø50x4.5.
Kasutada tohib ainult neid kihtsein-plasttorusid millele tootja annab 50 aastase kasutusea (kaasa
arvatud liitmikud) ning juhul kui tootja ei suuda kasutusiga tagada tuleb konstruktsioonide sisse
jäävad torustikud asendada PEX plasttoru vastu.
Torustikud paigaldada üldjuhul lagede alla ja vertikaalsed osad seinakonstruktsiooni. Torupüstikud
paigutada postide kõrvale või selleks ette nähtud šahtidesse. Tehnilistes ruumides monteeritakse
veetorustikud pinnapealselt. Pinnapealselt paigaldatavad veetorustikud monteeritakse sirgetest alupex
veevarustuse kihtsein-plasttorudest.
Kõik torud ja seadmed peavad olema transporditud ja ladustatud sellisel viisil, et pealispinnad, torustiku
otsad ja muud seadmete osad ei saaks mehaaniliste ja keemiliste mõjurite toimel vigastada.
Torudel peab olema sissepressitud või kustumatu kehtivatele normidele vastav märgistus, kus on ära
näidatud tootja nimi või identifitseerimismärk, toote määrav standard, valmistamisaeg,
nominaaldiameeter, toru klass, kasutusala ja lõpuks number, mille järgi on võimalik määrata torude ja
liitmike katsetamise tingimused.
3.2. Armatuur
Hargnemiskohtades kasutada sulgarmatuuri. Armatuurina kuni DN50 mm, kasutada kuulkraane PN10.
Ventiilide ja siibrite hoovad peavad olema suunatud kas ülespoole või kõrvale, kuid mitte kunagi allapoole.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 6 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
Tagasilöögiklapp paigaldada peale veearvestit, vältimaks vee tagasivoolu. Paigaldada valmistaja juhiste
kohaselt.
3.3. Toruliitmikud ja ühendused
Vastavalt kasutatava toru tootja soovitustele. Toruliitmikud peavad olema kasutatava toruga materjalilt ja
mõõtmetelt kokkusobivad.
3.4. Läbiminekud tuletõkkesektsioonidest
Plasttorustike läbiminekud tuletõkketarindist ei tohi vähendada tarindi tulepüsivust.
Plasttorude läbiviigud tuletõkke tarinditest varustatakse tuletõkke mansettidega ning torudel kuni ø50 mm
spetsiaalse paisuva tuletõkkemähisega.
3.5. Toestus ja kinnitused
Kõik torud peavad olema toestatud ja kinnitatud nii, et oleks kindlustatud täielik ohutus. Arvesse tuleb võtta
koormused, mis tulenevad toru kaalust, pikenemisest töötamise ajal, proovisurvestusest jne. Kõik veetorude
kinnitid peavad olema elasttihendiga tsingitud terasest või kõvaplastist (seintel nähtavana).
Kinnitite maksimaalsed vahekaugused veetorudele võtta järgnevast tabelist:
Komposiittoru
Toru Komposiittoru
vertikaalsed,
diam. horisontaalsed, (cm)
(cm)
16 120 150
20 130 170
25 130 200
32 140 210
40 140 220
63 150 260
50 150 285
3.6. Torustike isoleerimine
Projekteeritud külmavee magistraal- ja jaotustorustikud isoleeritakse alumiiniumfooliumiga pinnatud
kivivillkoorikutega vastavalt isolatsiooni paksuste tabelile- seeria 21. Projekteeritud soojavee ja soojavee
ringluse magistraal- ja jaotustorustikud isoleeritakse alumiiniumfooliumiga pinnatud kivivillkoorikutega
vastavalt isolatsiooni paksuste tabelile - seeria 23. Isolatsiooni tuletundlikkuse klass on B-s1,d0.
Kasutatavad isolatsiooni paksused on järgmised:
Toru ø Seeria 21 Seeria 23
Du s a b s a b
mm mm mm
10…49 20 110 70 30 130 80
50…89 30 130 80 40 150 90
90…169 40 150 90 60 170 100
3.7. Hüdraulilised katsetused
Suurim lubatud proovirõhk plasttorudel 1000 kPa (10 bar). Seda ei tohi tihedusproovi ajal ületada. Tavalise
tihedusproovi ajal võib elastne plasttoru veesurve mõjul paisuda, mis manomeetril ilmneb rõhu alanemisega.
Rõhu stabiliseerumine võib võtta ööpäeva ning alles seejärel saab kontrollida tihedust.
Samuti võimalik teha surveproovi kiirkatse:
• süsteem täidetakse veega ja õhustatakse;
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 7 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
• Rõhk tõsta 1,5 x töörõhk (max rõhk 1000 kPa). Rõhku hoida 0,5 tundi sellel tasemel, lisades
torude paisumise korral torustikku vett. Kontrollida, et torustikuga ühendatud seadmed taluvad
proovirõhku ja vajadusel eraldada need surveproovi ajaks torustikust;
• Vesi lasta kiiresti välja, kuni rõhk on alanenud töörõhu poole väärtuseni. Sulgeda
tühjendusventiilid;
• Veekindlas torustikus stabiliseerub rõhk mõne minutiga (1000kPa võrgustikus 500kPa-st kuni
700kPa-ni);
Rõhku kontrollida 1,5 tunni jooksul. Kui rõhk selle aja jooksul ei alane, on süsteem veekindel. Väike leke on
manomeetril kohe nähtav.
4. Tuletõrjeveevarustus
4.1. Tuletõrjevee välisvõrgud
Kustutusvee minimaalne vooluhulk on 10 l/s, mis peab olema tagatud 3 tunni jooksul. Hoonestusest lähemal
kui 200 m paikneb olemasolev hüdrant nr 1606.
4.2. Tulekaitse
Isolatsiooni katete pinnakihtide süttivustundlikkus peab üldjuhul vastama klassile B-s1-d0, tehnoruumides,
koridorides B-s1,d0 ja evakuatsioonitrepikodades A2-s1,d0. Kui isoleeritav toru läbib tarindit, siis peab
isolatsioon ulatuma terviklikult läbi tarindi. Torude läbiviimisel tuletõkketarinditest tuleb läbiviigukohad
tihendada selliselt, et läbiviik ei vähendaks tarindi tule ja suitsu tõkestamise võimet.
Torustikega tuletõkkesektsioonide piirist läbiminekul kasutada:
• torud, läbimõõduga alates 50 mm ja suuremad - kasutada tuletõkkemansette.
• torud, mis on läbimõõduga alla 50 mm - kasutada tuletõkkemähiseid, -laminaate või paisuva
omadusega tuletõkkesilikooni.
5. Reovee kanalisatsioon
5.1. Arvutuslik vooluhulk
Juurdeehitus
• sekundiline 6,8 l/s;
• ööpäevane 9,5 m³/d.
5.2. Eelvool
Reoveekanalisatsiooni eelvooluks on Tartu tänava ühiskanalisatsioonitorustik.
5.3. Puhastusseadmed
Hoonesse puhastusseadmeid ei projekteerita.
5.4. Pumpla
Kuna isevoolselt ei ole võimalik -1. korruse sanitaarseadmed kanaliseerida, siis on tehnilisse ruumi
projekteeritud trapp pumpla.
6. Sajuveekanalisatsioon
Hoonetel on välimine sademevete äravool.
Kuna piirkonnas puudub sademeveekanalisatsiooni torustik tuleb sademeveed immutada kinnistul läbi
haljasala pinnasse.
6.1. Arvutuslik vooluhulk
• Qs, katus = 82.4 l/s;
• Qs, platsid = 102.1 l/s.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 8 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
Sajuveekanalisatsiooni arvutuslikud vooluhulgad arvutatakse vastavalt EVS 846:2021 toodud
arvutusmetoodikale.
Sademevee intensiivsuseks on arvestatud 3 aasta korduvuse ja 5 minutit kestva vihma korral 343,1 l/s (ha).
6.2. Puhastusseadmed
Ei projekteerita.
6.3. Pumpla
Ei projekteerita.
7. Kanalisatsioonitorustike paigaldus
7.1. Torustike materjalid
Reoveekanalisatsiooni tarvis kasutada PP ja/või HTP materjalist torusid.
7.2. Torustikud ja armatuur
Reoveekanalisatsioonis kasutatavad torud on välisdiameetriga Ø32÷Ø160. Kasutatakse torusid, mille
rõngasjäikuse klassiga on S16 või S14.
Torustikud paigaldatakse kaldega, mis tagab vajaliku isepuhastuskiiruse. Ø50 i=0.025,
Ø75 i=0.02, Ø110 i=0.02, Ø160 i=0.01.
Toruliitmikud peavad olema kasutatava toruga materjalilt ja mõõtmetelt kokkusobivad.
Nähakse ette puhastustükid ja puhastusluugid 1-korrusele. Süsteemi õhutamiseks viiakse õhutorud läbi
katuse 0,7 m üle selle pinna.
7.3. Toestus ja kinnitused
Plastkanalisatsioonitorustike kinnituste, riputite vahekaugus mitte vähem, kui alltoodud tabelis.
Välisdiameeter (mm) Horisontaalsete kinnitite Vertikaalsete kinnitite
maksimaalne vahekaugus (m) maksimaalne vahekaugus (m)
32 1,2 0,5
50 1,2 0,7
75 1,8 0,8
110 1,8 1,0
160 2,3 1,5
7.4. Torustike isoleerimine
Kõik kanalisatsioonipüstikud ja laealused torustikud isoleerida 50 mm paksuse al.fooliumkattega
mineraalvillast toruisolatsiooni koorikutega (tihedus ≤100 kg/m3), kui ei ole joonisel näidatud teisiti.
Toruisolatsiooni süttimistundlikkus-tulelevimisklass peab olema BL-s1, d0.
7.5. Läbiminekud tuletõkkesektsioonidest
Plasttorustike läbiminekud tuletõkketarindist ei tohi vähendada tarindi tulepüsivust.
Plasttorude läbiviigud tuletõkke tarinditest varustatakse tuletõkke mansettidega ning torudel kuni Ø50 mm
spetsiaalse paisuva tuletõkkemähisega.
7.6. Hüdraulilised katsetused
Omaniku järelvalvel on õigus nõuda isevoolse torustiku veepidavuse katset.
8. Drenaaž
Hoonele drenaaži projekteerita.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 9 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
9. Keskkonnakaitsemeetmed
Ehituse käigus tuleb järgida keskkonnakaitse reegleid.
9.1. Ehitusjäätmed
Ehitamisel tekkivad jäätmed sorteeritakse ehitusplatsil ja viiakse ära jäätmete ehitusaegses kogumiskohta või
taaskasutatakse. Ehitusjäätmeid ei tohi anda vedamiseks, kõrvaldamiseks või taaskasutamiseks üle isikule,
kellel puudub vastav jäätmeluba või kes ei ole ehitusjäätmete vedajana registreeritud. Ehitusjäätmete
kogumine ja utiliseerimine on ehitaja kohustus. Ehitaja kohustus on esitada kasutusloa taotlusel
jäätmearuanne.
9.2. Haljastuse taastamine
Torustike rajamise järel taastada endine olukord või teostatakse haljastamine vastavalt projektile.
10. Tehnosüsteemide eluiga
Hoonesse kavandatavate tehnosüsteemide eluiga peab olema vähemalt nii pikk kui seda kehtestavad
üldtunnustatud ehitusreeglid ehk hea ehitustava. Hoonesse kavandatavate mittevahetatavate süsteemide
eluiga peab olema 50 aastat. Tehnosüsteemi eluiga tagatakse vastupidavate materjalide valikuga,
kvaliteetse ehitustöö ning korraliste hooldustöödega ekspluatatsioonis.
11. Kvaliteedi- ja kontrollinõude
11.1. Üldnõuded
Ehitada võib ehitusettevõtja, kelle töötajate pädevus vastab ehitusseaduses sätestatud nõuetele. Ehitamise
käigus tehtavad tööd dokumenteerib ehitust teostav isik.
Ehitamise tehnilised dokumendid on:
• Ehitusprojekt ja selle muudatused;
• Ehitustööde päevik;
• Töökoosolekute protokollid;
• Teostusjoonised;
• Kaetud tööde aktid;
• Muud ehitamist iseloomustavad dokumendid, näiteks ehitustoodete vastavusdeklaratsioonid
või vastavussertifikaadid.
Töötajad peavad olema varustatud töökaitseks ette nähtud turvavahenditega. Kogu personal peab olema
instrueeritud vastavalt töökaitseseadusele.
Töö tegemisel ning järelevalve korraldamisel tuleb lähtuda kvaliteedinõuetest. Kvaliteedi tagamiseks peab
tööde tegijal olema vajalik kvalifikatsioon ja litsents. Ettevõtja vastutab, et tööde kvaliteedinõuded oleksid
täidetud.
Juhul, kui töövõtja kasutab projektis määratud seadmete ja materjalide asemel analoogseid seadmeid ja
materjale, peavad need oma suuruselt, asukohalt, tööpõhimõttelt ja tehnilistelt parameetritelt vastama
töövõtu dokumentides määratud seadmetele ja materjalidele. Nende seadmete ja materjalide valimisel on
vajalik tellija ja santehniliste tööde järelevaataja kirjalik nõusolek enne kõnealuste seadmete ja
materjalide hankimist, kui need erinevad projektis märgitutest. Valiku õigsuse eest vastutab töövõtja.
11.1.1. Seadused ja määrused
Ehitustööd peavad vastama kehtivatele õigusaktidele, ajakohastele normdokumentidele, arvestama vee-
ettevõtte nõudeid ning kõiki torustikuosade valmistajate erinõudeid.
Kõik seadmete ehitus- ja montaažitööd tuleb teha nii, et need vastaksid kehtivatele seadustele ja
määrustele.
Seletuskiri ja joonised täiendavad üksteist. Võimalikud lahkarvamused lahendab peatöövõtja.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 10 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
Seadmete ja materjalide tehnilised andmed on põhiliselt antud joonistel ja spetsifikatsioonis.
Projekti puudutavad märkused peab töövõtja esitama kirjalikult peatöövõtjale hinnapakkumise ajal. Kui
seda ei tehtud, loetakse projekt märkusteta vastuvõetuks.
11.1.2. Muudatused
Kui tööde käigus toimuvad ehituslikest põhjustest või töövõtja soovil projektis muudatused, mis
muudavad tööde maksumust, on töövõtja kohustatud selle kohta andma kirjaliku hinnapakkumise, ning
alles peatöövõtja (tellija) kirjalikul nõusolekul on see pakkumine jõus lisakulutuste esitamiseks. Kui
töövõtja soovib tööde käigus muuta projekti, peab ta saama peatöövõtja kirjaliku nõusoleku. Töövõtja
peab andma materjalide ja seadmete ühikhinnad, kui peatöövõtja seda soovib.
11.1.3. Kvaliteedi tagamise ja kasutuselevõtu üldnõuded
Sanitaartehnika süsteemid peavad üleandmisel olema lepingudokumentide kohased ja toimima lepingus
ette nähtud viisil.
Kogu ehituse jooksul kontrollitakse pidevalt lepingudokumentides ette nähtud nõuetele vastavust ning
sanitaartehnika süsteemide ja seadmete projektikohast toimimist. Kontrollitulemused protokollitakse
kontroll- ja vaatlusprotokollides.
11.1.4. Tihedus- ja surveproovid
Tihedus- ja surveproovide ajal peavad kontrollitava sanitaartehnika süsteemi või selle kokku lepitud osa
liitmikud olema nähtaval. Surveproovid tuleb teha enne paigaldiste isoleerimist ja katmist. Tihedus- ja
surveproovide kohta koostatakse protokoll.
Dokumentides määratakse:
- Tihedus- ja surveproovide ulatus;
- Iga süsteemi torustiku katsetamise rõhk, katse kestus, võrgu täitmine ja selle puhastamine pärast
proovi;
- Manomeetri lugemi täpsus;
- Lekete kontrollimise põhimõte;
- Iga tihedus- ja survekatse tulemuste protokollimine;
- Abinõud tihedus- ja surveproovide järel.
11.1.5. Seadmete ja paigalduse kontrollid
Seadmete ja paigalduse kontrolli tehakse kogu ehituse jooksul vastavalt tööde edenemisele. Seadmete ja
paigalduse kontrollimisel tuleb veenduda, et
- Sanitaartehnika tooted, materjalid ja paigaldusviisid on lepingudokumentide kohased
- Sanitaartehnika toodete kasutus, hooldus ja tööturvalisus on nõute kohased
- Sanitaartehnika tooteid on võimalik puhastada paigaldatud hooldus- kontroll- ja puhastusluukide
või lahtivõetava lõppeseadme kaudu.
11.1.6. Üleandmis- ja kasutus dokumendid
- Täidetud masinakaardid
- Mõõtmis- ja reguleerimisprotokollid
- Seadmete hooldus- ja kasutusjuhised
- Paigaldatud seadmete tooteesildised koos võimsusgraafikutega (näiteks reguleerventiilid,
pumpad, puhurid, soojussalvestid, soojuskandjad, ehitusautomaatikaseadmed)
- Surve- ja tihedusproovide protokollid
- Ametite kontrolli tunnistused
- Surveseadmete dokumendid
- Võimalik garantiidokumendid ja hoolduslepingud
- Kommunaalteenuste kulu ja mõõturite näidud üleandmise päeval
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 11 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
Hiljemalt vastuvõtukontrolli ajal antakse üle kaks komplekti üleandmisdokumente. Järelevalve kontrollib
üleandmiskausta ja hooldusraamatut. Üleantavasse komplekti peavad kuuluma vähemalt kaust
registreeritud projektdokumentidega ja kaust, kus on muud eraldi kokkulepitud dokumendid.
11.1.7. Garantiiperioodi meetmed
Garantiiperioodi sanitaartehnika süsteemides avastatud vead ja puudused tuleb lepingudokumentide
kohaselt remontida.
Garantiiperioodi töödest koostatakse kasutus- hooldusjuhise hoja hooldusraamatu lisa, milles
kokkulepitud mahus esitatakse:
- Töövõtjad käsitlev teave;
- Eri töövõtjate garantiiperioodide algus- ja lõppkuupäevad
- Kasutuskoolituse kuupäevad
- Mõõtmise- ja reguleerimise kontrollimiseks kokkulepitavad kuupäevad
- Garantiihoolduse kalenderplaan
- Garantiihoolduse meetmed
- Mõõtmistulemused
- Sanitaartehnika süsteemide kasutamisel avastatud puudused
- Kasutus- ja hooldusjuhises või hooldusraamatus avastatud puudused
Sanitaartehnika süsteemide garantiihooldus korraldatakse lepingudokumentide nõuete kohaselt.
11.2. Tööde teostamine
11.2.1. Toed ja kinnitused
Kinnitused ei tohi nõrgendada ehituskonstruktsioone.
11.2.2. Elektriseadmed
Pingesüsteem 400/220 V 50 Hz.
Elektrimootorite ja muude elektriseadmete kaablite läbiminekukohad peavad olema varustatud kaabli
läbimõõdule vastavate tihendustega.
Elektrimootorid peavad vastama projektis esitatud seadmete võimsusele. Elektriajamiga seadmed tuleb
hankida komplektselt. Seadmete sees olevad juhtmed peavad olema valmismonteeritud.
Kõigi pumpade, ventilaatorite, elektriajamiga ventiilide, jms. seadmete, mille käivitamine toimub elektrienergia
abil, lülitusseadmestik ning kaablid elektritööde koosseisu.
11.2.3. Seadmete ja torustike märkimine
Kõik töövõttu kuuluvad seadmed tuleb varustada siltidega, kuhu on märgitud andmed süsteemide
numbritega ja teeninduspiirkonnaga.
Seadmed, mis jäävad ripplagede peale ning šahtidesse, tuleb seadme asukohta kindlaks määramiseks
varustada siltidega.
Süsteemide suunanooled magistraaltorustikel tuleb kinnitada igale seinast läbimineku kohale ja seadmete (nii
surve kui imepoolele) vahetusse lähedusse.
11.2.4. Akustilised ja vibratsioonivastased nõuded
Töövõtja peab paigaldama kõik masinad ja seadmed, milles on pöörlevaid või teisi müra tekitavaid osi,
vibratsiooni summutavatele alustele. Vibratsiooni alus peab töötama temperatuurivahemikus -10 kuni +70 °C
ja olema vastupidav hapetele ja vananemisele. Seadmete montaažil ei tohi ühegi elektril töötava seadme
ning ehitusliku konstruktsiooni vahel olla mingi jäiga kinnituse tõttu otsest kontakti.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 12 / 13
TELLIJA: MUSTVEE VALLAVALITSUS
OÜ Smart Pipes
TÖÖ NIMETUS: MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED
AADRESS: TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
TÖÖ NR: 25034
KÖIDE: HOONE VEEVARUSTUS JA KANALISATSIOON
STAADIUM: EELPROJEKT
11.3. Hüdraulilised katsetused
11.3.1. Veetorustiku hüdraulilised katsetused
Suurim lubatud proovirõhk plasttorudel 1000 kPa (10 bar). Seda ei tohi tihedusproovi ajal ületada. Tavalise
tihedusproovi ajal võib elastne plasttoru veesurve mõjul paisuda, mis manomeetril ilmneb rõhu alanemisega.
Rõhu stabiliseerumine võib võtta ööpäeva ning alles seejärel saab kontrollida tihedust.
Samuti võimalik teha surveproovi kiirkatse:
• süsteem täidetakse veega ja õhustatakse;
• Rõhk tõsta 1,5 x töörõhk (1.5x440kPa=660kPa) (max rõhk 1000 kPa). Rõhku hoida 0,5 tundi
sellel tasemel, lisades torude paisumise korral torustikku vett. Kontrollida, et torustikuga
ühendatud seadmed taluvad proovirõhku ja vajadusel eraldada need surveproovi ajaks
torustikust;
• Vesi lasta kiiresti välja, kuni rõhk on alanenud töörõhu poole väärtuseni. Sulgeda
tühjendusventiilid;
• Veekindlas torustikus stabiliseerub rõhk mõne minutiga (1000 kPa võrgustikus 500kPa-st kuni
700kPa-ni);
Rõhku kontrollida 1,5 tunni jooksul. Kui rõhk selle aja jooksul ei alane, on süsteem veekindel. Väike leke
on manomeetril kohe nähtav.
Pärast katsetuse lõpetamist tuleb kontrollida kõiki torustiku ühenduskohti.
Testimine tuleb teha enne torustike katmist isolatsiooniga ja Tellija juuresolekul. Kõik testimisaktid tuleb
esitada Tellijale kooskõlastamiseks.
Peale veetorustiku katsetamist tuleb süsteem puhtaks pesta, desinfitseerida ja veeanalüüs anda
sõltumatule kontroll-laboratooriumile, mis on tellija poolt kooskõlastatud.
11.3.2. Kanalisatsioonivõrgu paigaldus ja hooldus
Kõigile isevoolsetele torustikele tehakse tihedusproov veega, näiteks vastavalt standardile SFS 3113 või
temaga võrdväärsele standardile. Tihedusproov tehakse korraga ühe kaevelõigu ulatuses kui kaevik on
täidetud. Selle meetodiga on võimalik teha eelkontroll ka lahtisel torustiku osal. Kontrolli võib teha ka
osaliselt täidetud kaevise korral nii, et liitekohad on jäetud katmata võimaliku lekkekoha avastamiseks ja
parandamiseks. Enne proovi puhastatakse torustik mullast ja muudest osistest. Torustik, kus proovi
tehakse, suletakse troppidega. Tropid tuleb asetada nii, et nad proovi ajal lahti ei tuleks. Kui torustikul on
harusid, suletakse ka need troppidega tihedusproovi ajaks. Kui proovi tulemus pole vastuvõetav, tuleb
lekkekoht avastada ja parandada. Projekteeritud ja paigaldatud hoone kanalisatsioonisüsteem peab
vastavalt standardile EN1451 vastu pidama 0,5 bar rõhule).
Tabel. Kanalisatsioonitorude survekatsetused
Karakteristik Nõue Testi parameetrid Testi meetod
veetihedus lekkevaba veesurve kestvus 0,5 bar-15 min EN 1053
Majaka tn 44-9, Tallinn, Harjumaa, 11412 18.07.2025
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 13 / 13
Miniarena - ol.ol.
TINGMÄRGID:
Kiik
jon
Lammutatav hoone
st
il
Pav
aka
Liiv
Uus ehitatav hoone/räästas, varikatus
gi
mä
de
Liu
tas
gas
Rekonstrueeritav hoone/ räästas, varikatus
aas
Kün
P3
3 -6
P3
Kiik
ine
nim
PV paneelide paigaldusala
Tur
t
kas
a
Liiv
Suur turnimispüramiid
ad a
r
Lasteaia mänguhoov
ksu
uala
joo
ng
ta ja
imä
Kiik
Mänguhoov kokku 1025m² - min 17m²/laps
d
Pall
Rat
ase
a ast
1-3
Hekk
TINGMÄRGID. ELEKTRIVARUSTUS. AXYS OÜ
t
kas
a
Liiv
Võrkaed
Ø160 SN8
34.43
L=1.5m
32.92 i=0.008
32.92
25
/2
25
0/2
Ø160 SN8
10
DN
L=19.0m 2
K
1
-1
i=0.008
Rü
K.M hm 3
o sa
Staadion - rekonstrueeritav 34.20 . -0
Rü ,20
3.
32.93
K.M hm 2
1
-
34.43 . -0
K1
ed
,20
32.77
tea
32.77
32.77
Las
Ø110 SN8
Rü
2 L=2.9m K.M hm 1
Ø160 SN8 1
3 i=0.008 Pe . -0,
rso 20
L=24.6m na
l/
i=0.008 õh
tu kas
34.20 utaj
a
X
32.79 d
Pä
ä
K.M s sta
1
Korvpall . -0 adio TINGMÄRGID:
K1X
,20 nil
e
34.43
X
32.57
32.57 Jal Projekteeritud soojustorustik
X
grat
32.57 tad
Ø160 SN8 T Likvideeritav soojustorustik
X
2
L=4.5m T
1K id,
3
var tusr . osa
1
X i=0.008
jen uum
X
X
Rii ol - 1
34.43 X TINGMÄRGID
d-
Ø160 SN8 34.20
32.28 Eva
X
Ko
L=8.2m K.M k. (SMART PIPES OÜ töö nr 25034)
e
32.28 32.61
i=0.006 . -0
,2 0
Jal
X
gra
t
K11 PROJEKTEERITUD KINNISTU REOVEEKANALISATSIOONITORUSTIK
tad
1
K
K1
Ø160 SN8 LIKVIDEERITAVAD TORUSTIKUD
X
X X X X
ab ne 2
L=20.2m
i=0.006 Ø160 SN8
o
X
35 l. ho
L=30.4m
s.
34.43 i=0.008
32.16 Ø160 SN8
o
Ol.
X
Ho PROJ. HOONE TOITEKAABLID 2x(AXPK4G300)
,03
0,0 - ol.
32.16 ol. 2 ov
K.M L=3.6m
sku 1
X ipä
lpt
uu -0, äs
.i=0.006
40 ELEKTRIVÕRGU LIITUMISPUNKT
sa
r
X
1 2
0=
Ø160 SN8 X3
.o
L=4.7m Prü AS INFRAGATE EESTI TÖÖ NR MS6/132-25
-1
1 X
gi
i=0.006 P9 TEEDE TINGMÄRGID:
ol
P3
Lip
K1
u
X
Ko
d 34.20 Projekteeritud katte serv
32.35 Projekteeritud metallääris (LineFix või muu sarnane)
X
34.43 P8 Projekteeritud sõidutee asfalt (Tüüp 1)
Pe
32.33 r
K.M sona
+1 P31 Projekteeritud kõnnitee asfalt (Tüüp 2)
X
N 6526950000 2 Projekteeritud kõnnitee sillutiskivi (Tüüp 3)
1 32.33 .0 l
P8
2
E 669650000 3 ,00 Projekteeritud murukivi (Tüüp 4)
4 32.33
1
Projekteeritud EPDM katend (Tüüp 5)
Projekteeritud kruusapeenar (positsioon nr 6)
Pe
rso 34.65 Projekteeritud betoonplaadi taaspaigaldus (vajadusel uuega asendamine)
na
K.M l / k 32.97 Projekteeritud haljastus
OL.OLEV SIDE LIITUMISPUNKT
. -0 ülali Ha Projekteeritud nõlv
,40 sed rid
usk Projekteeritud sõidutee äärekivi h=7 cm
34.44
Pe Ø160 SN8 esk Projekteeritud sõidutee äärekivi h=3 cm
32.10 asi L=2.9m
us Projekteeritud sõidutee äärekivi h=0 cm
OL.OLEV REOVEEKANALISATSIOONI LIITUMISKAEV 31.90 sse -2 34.69 911
Projekteeritud teemärgistus (värv/termovaluplastik)
K.M
p i=0.008 .o 33.17
32.13 34.50 ,00 ää
.0 sa Projekteeritud kummist parkimistõkend
32.30 s -2 Ma (h=10 cm, b=15 cm, l=182 cm)
32.94 K K.M terja P8 Projekteeritud parkimiskohtade arv
32.94 . 0 lid
,00 Projekteeritud liiklusmärgi post
X
32.94
Ø160 SN8
X
2 X
3
P
1 X 3 2
L=1.2m
X
X
1 12
1 2 X
X X
Kö i=0.008
X
Ø160 SN8 X X X X
K.M ögi v
L=5.4m . 0 aru
,00 stu
i=0.008 s
34.65
OL.OLEV VEEVARUSTUSE LIITMISPUNKT 33.10
33.17
Ø160 SN8
L=1.7m
i=0.008
34.57 Tähis Muudatus Teostaja Kuupäev
34.71 32.98
32.87 33.08 TÖÖ NIMETUS TELLIJA
OL.OLEV REOVEEKANALISATSIOONI LIITUMISKAEV 32.90
MUSTVEE KOOL, MUSTVEE HARIDUSKESKUS JA LASTEAED MUSTVEE VALLAVALITSUS
Ø160 SN8 AADRESS JOONIS
L=4.8m TARTU TN 11, MUSTVEE LINN, JÕGEVAMAA
i=0.008 VEEVARUSTUS JA KANALISATSIOON
VÄLISVÕRKUDE ASENDIPLAAN
Smart Pipes OÜ
VASTUTAV SPETSIALIST
V.LOORENTS
Registrikood 11979398 PROJEKTEERIJA FAILI NIMI
tel +372 526 8802 25034_VK_asendiplaan.dwg
[email protected] V.LOORENTS
Majaka tn 44-9, Tallinn, Harjumaa, 11412 OSA STAADIUM KUUPÄEV TÖÖ NR MÕÕTKAVA JOONISE NR JOONISTE ARV
MTR EEP001966, EPE000622 VK EP 18.07.2025 25034 1:500 VVK-1
Mustvee Vallavalitsus Teie 14.04.2026
[email protected]
Tartu tn 28 Meie 23.04.2026 nr 7.1-2/26/6383-2
49603, Jõgeva maakond, Mustvee
vald, Mustvee linn
Ehitusloa taotluse nr 2611271/03029 kooskõlastusest
keeldumine ja nõuete esitamine ehitusprojektidele riigitee
nr 36 maaüksuste piirides ja tee kaitsevööndis
Mustvee linnas Jõgevamaal
Olete Transpordiameti (TRAM) kaasanud ehitisregistris (Ehitusloa taotlus nr 2611271/03029, menetlus nr
540219) Ehitusloa taotluse menetlusse. Koos ehitusloa taotlusega on ehitisregistris esitatud ka ehitiste ja
rajatiste ehitusprojektid, (edaspidi Projektid).
Riigitee tee piirides on ehitisregistris esitatud Projektide ja dokumentide järgi ette nähtud ehitada
ühisveevärgi ja -kanalisatsiooni torustikud koos sinna juurde kuuluvate ehitistega (edaspidi tehnovõrgud)
ja jalg- ja jalgtattateed (JJT) ning juurdepääsutee Tartu tn 11 maaüksusele Mustvee linnas Jõgeva vallas
Jõgevamaal. Projektide, AS Infragate Eesti töö nr MS6/132-25 (teede osa) ja OÜ Smart Pipes töö nr 25034
(veevarustuse ja kanalisatsiooni välisvõrk) jooniste järgi jäävad kavandatavad rajatised ja tehnovõrgud
riigitee nr 36 Jõgeva – Mustvee tee km 38,52-38,59 tee piiridesse (teemaale) ja tee kaitsevööndisse.
Projekteerimistingimuste menetlusse Transpordiametit ei ole kaasatud.
Võttes aluseks ehitusseadustiku (EhS) § 13, § 19, § 24, § 42, § 70, § 71, § 72, § 92, § 97, § 99 ning
Transpordiameti põhimääruse, ei kooskõlasta Transpordiamet esitatud Ehitusloa taotlust nr
2611271/03029, eelnõu ning Projekti ja esitame märkused ja nõuded Projekti täiendamiseks riigitee tee
piirides (teemaal) ja tee kaitsevööndis (EhS § 99 lg 3):
1. Ehitusprojekt peab olema selline, et selle kohaselt ehitatav ehitis vastaks nõuetele, sealhulgas arvestaks
ehitise sobivust, kasutatavust ja korrashoiu vajadust. Ehitusprojekti koostamisel tuleb arvesse võtta ka
ehitise asukohaga seonduvaid asjaolusid ja kitsendusi (Nõuded ehitusprojektile1; EhS § 13 lg 3) sh
riigitee püsivust ja toimimist.
2. Projekt tuleb koostada vastavalt selle ehitise ja tehnovõrgu projekteerimisnormidele ja riigiteede tee
piirides Tee projekteerimise normidele (EhS § 99 lg 4).
3. Tehnovõrkude projekteerimisel ja ehitustöödel riigiteede piirides tuleb juhinduda Transpordiameti
tüüpnõuetest: „Nõuded tehnovõrkude teemaale paigaldamise kavandamisel“ (Nõuded) , asub:
https://transpordiamet.ee/maanteed-veeteed-ohuruum/tee-ehitus/juhendid#tehnovrgud .
4. Kaevetöödel ja lahtiste kaevikute kavandamisel tuleb juhinduda Tööinspektsiooni juhendist
„Tööohutus ehitusplatsil, 2022“, asub: https://www.ti.ee/ennetus-ja-teave/infomaterjalid/trukised
5. Varisemisnurk millega me tehnovõrkude paigaldamisel kaevetöödel piki teed nõustume (mitte järsem)
on 1:3/4 (53°) eeldades A-tüüpi pinnast vt „Tööohutus ehitusplatsil).
6. Joonised tuleb esitada ka dwg formaadis.
7. Tehnovõrkude projekti koosseisus peavad olema ka Isikliku kasutusõiguse (IKÕ) plaanid kui
kavandatakse tehnovõrke riigitee alusele maale (kinnistule).
8. Märkused Projekti töö nr 25034 kohta:
8.1. Projekti koosseisus puuduvad joonised dwg formaadis – palume lisada;
9. Märkused Projekti töö nr MS6/132-25 kohta:
9.1. Seletuskiri lk 6 p 2.3 on
Valge 4 / 11413 Tallinn / 620 1200 /
[email protected] / www.transpordiamet.ee
Registrikood 70001490
Sõidutee katendi kihtide projekteerimisel on lähtutud Tallinna Linnavalitsuse 18. september 2019 istungi
protokolli nr 17 päevakorrapunkti nr 35 LISA 1 „Sillutiskivi, asfalt- ja tsementbetoonkatenditega teede ja
tänavate tüüpkatendikonstruktsioonide projekteerimisele, rajamisele ja remondile esitavad nõude“.
Sõidutee katendikihid on valitud nimetatud juhendist vastavalt katendi tüübile E5.
Selle väitega ei saa nõustuda, riigiteede tee piirides tuleb katendite projekteerimisel juhinduda TRAMi
veebilehel olevatest juhendmaterjalidest ja anda viited nendele ning asfadi jämetäitematerjalide nõuded
tuleb võtta standardist EVS 901-3:2021 arvestades, et riigiteel tehakse libedustõrjet kloriididega;
9.2. Joonised.
9.2.1. Projekti koosseisus puuduvad joonised dwg formaadis – palume lisada;
9.2.2. Katendi taastamise joonisel tuleb sõlme OK-2 juures näidata ka lahtise kaeviku põhja kontuur;
9.2.3. Palume riigitee tee piirides katendite taastamisel lisada ristlõikejoonised 4-tk
Kõikidel juhtudel (piki ja risti teed) nõustume katendikihtide taastamistel astmetega 30 cm.
Katete (katendi) taastamisel sõlme OK-2 juures (lõiked 2 ja 3) tuleb kaeviku nõlvas lähtuda
varisemisnurgast 53° ja katendi astmed aluskihtides 0,30m ja kulumiskihis (kõige ülemine) 0,50 m ;
asfaltsegu riigitee piirides AC 16 surf täitematerjalide nõue tuleb võtta EVS 901-3:2021 Tabel 7 veerg
AKÖL 900-1499, kuna riigiteedel tehakse libedustõrjet kloriididega ja seetõttu peab külmakindluse nõue
asfaltsegudes jämetäitematerjalidel olema täidetud. Dreenkihi filtratsioonimoodul, piisab kui on täidetud
nõue kf ≥ 0,5 m/ööp;
Palun esitada korrigeeritud, täiendatud projekt ja lahendus lähtuvalt ülaltoodud märkustest uuesti
kooskõlastamiseks.
Lugupidamisega
(allkirjastatud digitaalselt)
Arvo Veltri
peaspetsialist
planeerimise osakonna tehnovõrkude üksus
Lisa: MS6_EP_TL-3-01_Seletuskiri.zip; 25034_EP_VKS-3-01_seletuskiri.zip;
Arvo Veltri
5164006,
[email protected]