KUAB Konsult & Utveckiing AB
Calibration Certificate
The Falling Weight Deflectometer (FWD) KUAB 50 with serial number FV123, owned by West
Coast Road Masters OY, Fiiiland,manufactured by KUAB Konsult & Utveckiing AB in Sweden,
was in February 2024 calibrated by KUAB's personnel.
After the calibration the FWD FV123 measures with the same accuracy as a new KUAB 50 and meets
all relevant standards, including but not limited to ASTM D4694 and the Swedish Method Description
TRVMB 112.
The result of the calibration was recorded in the configuration file FVO.INI in the laptop operating the
FWD. The result of the calibration is also shown below. Descriptions of the calibration methods and
the calculations giving these numbers are available at KUAB, email all(g),kuab.se.
KUAB STATIC SEISMOMETER CALIBRATION OUTPUT FILE FV123
Date: 15.2.2024
Time: 13:15:12
A/D c o n v e r t e r b i t v a l u e N/A mV/bit
C a l i b r a t i o n f a c t o r f o r seismometer 0 0.486541 pm/mV
C a l i b r a t i o n f a c t o r f o r seismometer 0.4 622 66 pm/mV
C a l i b r a t i o n f a c t o r f o r seismometer 0.461810 pm/mV
C a l i b r a t i o n f a c t o r f o r seismometer 0.492542 pm/mV
C a l i b r a t i o n f a c t o r f o r seismometer 0.4 66397 pm/mV
C a l i b r a t i o n f a c t o r f o r seismometer 0.4 68841 pm/mV
C a l i b r a t i o n f a c t o r f o r seismometer 0.4 44085 pm/mV
C a l i b r a t i o n f a c t o r f o r seismometer 0.477430 pm/mV
SO SI S2 S3 S4 S5 S6 S7 DO Dl D2 D3 D4 05 D6 07
V o l t a g e a t 3 25 -2597 -2769 -2725 -2510 -2619 -2712 -2846 -2669
V o l t a g e a t 3 50 -2087 -2237 -2189 -2008 -2087 -2180 -2285 -2158
Position 5.25 5.25 5.25 5.25 5.25 5.25 5.25 5.25
Voltage 1506 1542 1589 1535 1657 1545 1629 1490
Voltage a t 3 25 -2598 -2772 -2728 -2508 -2623 -2711 -2852 -2665
Voltage a t 3 75 -1574 -1695 -1654 -1508 -1552 -1645 1729 -1632 -767 -786 -767 -745 -726 -773 -772 -785
Voltage a t 3 75 -1574 -1695 -1654 -1505 -1552 -1645 1729 -1633 -767 -786 -7 67 -744 -726 -773 -773 -785
Voltage a t 4 25 -546 -615 -571 -489 -482 -585 -611 -594 -266 -285 -265 -242 -226 -275 -273 -286
Voltage a t 4 75 482 468 513 525 591 484 517 450 235 217 238 260 276 227 231 216
Voltage a t 5 25 1506 1542 1586 1535 1656 1546 1628 1490 734 716 735 759 775 726 728 717
Voltage a t 5 75 2526 2618 2660 2547 2719 2611 2745 2538 1231 1215 1233 1259 1272 1227 1227 1220
Voltage a t 6 25 3542 3687 3726 3551 3773 3661 3853 3561 1726 1711 1728 1755 1765 1720 1722 1712
Voltage a t 6 75 4546 4746 4780 4541 4820 4703 4939 4586 2216 2202 2216 2245 2254 2210 2207 2205
Voltage a t 7 25 5536 5797 5819 5526 5856 5730 6008 5601 2698 2690 2698 2732 2739 2692 2685 2693
Calibration factor for seismometer 0 = 0.487374
Calibration factor for seismometer 1 = 0.463954
Calibration factor for seismometer 2 = 0.463587 KUAB Konsult & Utvec'-Jing AB
Calibration factor for seismometer 3 = 0.494386
Calibration factor for seismometer 4 = 0.467759
Calibration factor for seismometer 5 = 0.469823 Box 10, 795 21 Rattvik, SwGd«
Calibration factor for seismometer 6 = 0.446862
Calibration factor for seismometer 7 = 0.480853
Calibration certificate page 1 of 2
Postal address Teiephone e-mail/ Visiting address VAT number
Box 10 Nat 070 3344354
[email protected] Faluvagen 6 SE556311352001
S-795 21 Rattvik Int +46 70 3344354 S-795 35 Rattvik
Sweden Sweden
[loadmodel]
description=2 + 2 buffers
ForceThreshold=500
SensorThreshold=100
risetime=25
aload(l)=1209
aload(2)=3345
a]oad(3)=4083
aload(4)=5112
nominalload(l)=1200
nominalload(2)=3300
nominalload(3)=4000
nominalload(4)=5000
corfac(l)=.03
corfac(2)=.06
corfac(3)=.l
corfac(4)=.12
defaultheight(l)=.024
defaultheight(2)=.202
defaultheight(3)=.289
defaultheight(4)=.470
[loadplatel]
description=The small plate
radius=15
calfac= 17496
sharpcalfac=l
caladd=133
square=2580
[pavtemp]
;Rayomatic 14 / Optris CT
available=True
voltagefactor=.0025
lowestrange=-30
offset=0
xcoefficient(0)=0
xcoefficient(l)=130
xcoefficient(2)=0
xcoefficient(3)=0
xcoefficient(4)=0
[airtemp]
calfac=0.998478155785319
caladd=-273.15
offset=0
lastdate=l 5.2.2024
lasttime=14:02:22
Rattvik 2024 04 23
Calibration certificate page 2 of 2
Postal address Telephone e-mail/ Visiting address VAT number
Box 10 Nat 070 3344354 se Faluvagen 6 SE556311352001
S-795 21 Rattvik Int +46 70 3344354 S-795 35 Rattvik
Sweden Sweden
Saatja: Tiit Kaal <
[email protected]>
Saaja: Elmar Aruja, Juha-Matti Vainio
Teema: FWD mõõtmiste teostamise luba
Tere,
Edastan FWD mõõtmisloa väljastamiseks vajalikud dokumendid. Lisatud on
FWD mõõtmisseadmele KUAB FV123 selle tootja poolt väljastatud 2024 aasta
kalibreerimissertifikaat ning teekatte sisetemperatuuri mõõtmistel
kasutatavate termomeetrite võrdlusmõõtmiste tulemused.
Mõõtmistega alustame mai lõpus projekteerimisobjektil (mnt nr 11414),
misjärel jätkame mõõtmisi võrguobjektidel ja kruuskatete objektidel.
Alates augustist lisanduvad uute katete objektid. FWD mõõtmiste
edenemist saab jälgida (kui link ei avane siis palun teatada):
https://www.google.com/maps/d/edit?mid=1ICQ_8ogHH5xAYv98a_OFsx8qVlV9osw&usp=drive_link
Lugupidamisega
--
Tiit Kaal
Juhatuse liige/Konsultant
ERC Konsultatsiooni OÜ
tel. +3725269894
skype tiit.kaal
www.ercc.ee
Termomeetrite võrdlusmõõtmine Võrdlusmõõtmise teostamise eesmärk: FWD seadmega teekonstruktsiooni kandevõime mõõtmistel teekatte sisetemperatuuri mõõtmisel kasutatava te termomeetri te võrdlus etalon(võrdlus)termomeetriga. Võrdlusel kasutatav etalontermomeeter: Thermometer P4005W seeria nr 42124010017, kalibreerimistunnistus nr K058-22994 Võrreldav ad termomeetr id : FWD mõõtmistel teekatte temperatuuri (katte seest) mõõtmisel kasutatav ad termomeetr id Thermojack ( nr 0423) ja DTP 6 (nr 001) Võrdlusmõõtmiste teostamise kirjeldus: Kõik võrdluses kasutatavad termomeetrid on siseruumis asetatud veevanni. Võrdlust on teostatud 3-e erineva veetemperatuuri juures. Võrdlusmõõtmiste teostamise asukoht: Pori, Kanahaukantie Võrdlusmõõtmiste teostamise kuupäev: 0 7. 0 5.2024 Võrdlusmõõtmiste teostaja: Juha-Matti Vainio Võrdlusmõõtmise tulemused: Võrdluse nr Thermometer P4005W Thermojack DTP 6 Mõõtetulemus, 0 C Mõõtetulemus, 0 C Erinevus, 0 C Mõõtetulemus, 0 C E rinevus , 0 C Võrdlus 1 20.0 20.4 +0.4 19.9 -0.1 Võrdlus 2 25.5 25.7 +0.2 25.4 -0.1 Võrdlus 3 33.8 34.2 +0.4 34.0 +0.2 /allkirjastatud digitaalselt/ Tiit Kaal FWD mõõtmiste projektijuht ERC Konsultatsiooni OÜ Lisatud: Thermometer P4005W kalibreerimistunnistus