Commercial-in-Confidence Job No 206 2026
Marine Devision Ltd.
Date: 05.12.2023
Rev. 3
Marine Service Reporting Form - Technical Forms
Report of VFD replacement
Service
Date: 12/10/2026 Superintendent Alexey Vasiliev 1
Day:
MarDev representative
Vessel
m/v Atlantis Senior Service Antanas Slivinskas
Name:
engineer
Estimated
Chief el. electronic
Class: BV Aleksandr Prochorov Service 1
service Officer
Days
Electro technical eng.
Port Hamburg
Service
MSB AE ACB MD support team: Warranty Yes
Type:
Schneider Number of the service service
Maker: 2 11/10/2026
Electric people required start:
Masterpact service
Model: Weather conditions: Cloudy 18℃ 11/10/2026
NT06 H1 complete:
Short Port stay, cargo
Access for Service /
Ship activities ops in Hamburg
SUBJECT/ DESCRIPTION. Service/Replace ACB A.E No.2 . During cargo operation in port of Hamburg
NB! All works must be performed safely, without influence on environment. Ex certified tools and equipment used where appropriate
Daily Service Activities
Request of works to be done - Replacement of defective ACB of A.E.2, programming, commissioning test
at MSB and test of Owners supplied ACB for spare
Reported malfunction of the old ACB of Generator braker as follows:
The generator circuit breaker closes and immediately opens again. The breaker does not remain in the ON
position, and no Micrologic TRIP indication is displayed.
© Marine DEVISION Ltd. All rights reserved m/t Atlantis, Service in PORT HAMBURG, 11/ 10/ 2026
Commercial-in-Confidence Job No 206 2026
The fault was investigated by swapping the generator breakers. After exchanging the breakers between DG1 and
DG2, the problem followed the breaker itself, confirming that the fault is related to the Masterpact NT06 H1 unit and
not to the generator, synchronization system, or switchboard supply.
MD service engineers A. Sliviinskas and A.Prochorov travelled from Klaipeda, hand carried New ACB and attended
the vessel in Port of Hamburg to replace and program ACB A.E. No.2.
Before to commence the job onboard informed Ch. Engineer of service and Repair works progress plan.
Performed inspection of the MSB power unit sections. Checked MSB condition.
Installed new Circuit breaker, connected wirings. Completed settings and programming of parameters. Tested the
new circuit breaker supplied by the Owners.
Connected the wiring and completed the required parameter settings and programming.
New breaker - On load test, load sharing between generators, reverse power, undervoltage trip and Power
Management system performed with satisfactory results.
Calibration label and Manufacturers Quality Certificate left onboard
After repair and survey activities, the New installed ACB power unit tested in operation, and verified to be
complying for safe operation of Auxiliary engines and Power management system.
Recommend: Next service in 5 years at the planned Dry docking of the ship.
WARNING: Do not change the ACB parameters, settings, or protection functions without authorization.
Incorrect settings may cause improper operation, failure of the protection system, serious damage to the
ACB, and may create a fire risk or void the equipment warranty. All testing, adjustment, calibration,
programming, and servicing must be carried out in accordance with the manufacturer’s instructions by
qualified and authorized MD service engineers only to avoid possible damage to the equipment and
additional expenses.
Crew gives a good impression, assist fully and working together as a team.
© Marine DEVISION Ltd. All rights reserved m/t Atlantis, Service in PORT HAMBURG, 11/ 10/ 2026
Commercial-in-Confidence Job No 206 2026
BEFORE
© Marine DEVISION Ltd. All rights reserved m/t Atlantis, Service in PORT HAMBURG, 11/ 10/ 2026
Commercial-in-Confidence Job No 206 2026
AFTER ASSEMBLING and NSTALLATION
© Marine DEVISION Ltd. All rights reserved m/t Atlantis, Service in PORT HAMBURG, 11/ 10/ 2026
Commercial-in-Confidence Job No 206 2026
Please note that that the warranty we offer does not apply under following conditions:
• contamination of equipment and liquid damage
• improper cooling of component parts, shocks and impacts
• deformation caused by overheating
• standard decrease of parameters
• burnt or damaged cables
• Improper storage of spare parts onboard and warehouse
• limited access for maintenance
• Installation not as required by manufacturers and Class Society,
AICS member.
• Operator error and operation of equipment with critical alarms
• Use equipment at extreme conditions not as required by manufacturers or
without recommended maintenance.
© Marine DEVISION Ltd. All rights reserved m/t Atlantis, Service in PORT HAMBURG, 11/ 10/ 2026
INTERIM SURVEY STATEMENT
RTD0/2026/J6652
Report Nr
ATLANTIS Ship's Name
BV Reg. Nr.: 04343X
IMO Number: 9268174
Connecting District: BV HELSINKI
Flag: ESTONIA
Ship Manager: Ocean Fleet Management OU
Ship Owner: AB SHIPPING OU
DATES OF SURVEY PLACE OF SURVEY
Start 28 October 2026 Rotterdam
End 28 October 2026 NETHERLANDS
SURVEYOR(S) STAMP / SIGNATURE
Mahmoud Zayed
INTERIM SURVEY STATEMENT
Date of issue 28 October 2026 19:21:36
Issued by Mahmoud Zayed
This document is issued subject to SSQM validation and pending issuance of Survey Report
Interim Survey Statement
ATLANTIS BV Nr: 04343X
Survey(s) Carried out
Class
Machinery Occasional Survey (OSM);
Reason of Occasional Survey: Further to deal with and delete PII
New Coc/Recommendation(s) Issued
No recommendation issued during this attendance
Recommendation(s) Dealt with or Postponed
Coc/Recom. Number Description Status
Class - Machinery
TAL0/2026/J5052-M1R The circuit breaker of auxiliary engine No. 2 is to be definitive repaired. Deleted
Bureau Veritas Marine & Offshore Report N° RTD0/2026/J6652
28 October 2026 19:21:36 Page 2 / 2
Nikolai Sharonov
Ocean Fleet Management OÜ Your ref 15.09.2026
[email protected]
Our ref 16.09.2026 nr 17.1-3/26/14214-4
m/t ATLANTIS (IMO 9268174)
Dear Sir,
With reference to your request regarding m/t ATLANTIS (IMO 9268174), the Estonian Transport
Administration has reviewed the information submitted together with the Bureau Veritas survey
report TAL0/2026/J5052 dated 09 September 2026.
Taking into account that:
Bureau Veritas has carried out an Occasional Survey and issued the Classification
Condition TAL0/2026/J5052-M1C with validity until 31 October 2026;
the defective circuit breaker for Auxiliary Engine No. 2 has been ordered and delivery is
expected on 06 October 2026;
the vessel can safely operate with the remaining two auxiliary engines together with the
shaft generator available, as demonstrated by the submitted power load calculations;
the deficiencies and corresponding observations issued during the PSC inspection in
Hamburg on 06-07 August 2026 have been verified onboard and found satisfactorily
rectified by Bureau Veritas,
the Estonian Transport Administration has no objection to the postponement of the Class
Occasional Survey and accepts the temporary operation of the vessel with Auxiliary Engine No. 2
out of service until 31 October 2026, subject to the following conditions:
1. The requirements and limitations imposed by Bureau Veritas shall be strictly complied
with.
2. The repair of Auxiliary Engine No. 2 and replacement of the defective circuit breaker shall
be completed without undue delay after receipt of the spare part and not later than 31
October 2026.
3. The vessel shall maintain at all times adequate electrical generating capacity and the
availability of the remaining auxiliary engines, shaft generator and emergency generator.
4. Any deterioration of the vessel's electrical generating capability or any additional defects
affecting the power generation system shall be immediately reported to Bureau Veritas and
the Estonian Transport Administration.
Valge 4 / 11413 Tallinn / ESTONIA / +372 620 1200 /
[email protected] / www.transpordiamet.ee
Registry code 70001490
5. Verification by the Society Surveyor shall be carried out by the specified due date.
This acceptance is granted solely for the temporary condition described above and does not relieve
the owner, operator or Master from complying with applicable statutory or classification
requirements.
Yours sincerely
(Digitally signed)
Jan Jaanson
Head of Shipping Department
2 (2)
Saatja: "Nikolai Sharonov" <
[email protected]>
Saaja:
[email protected], "Transpordiamet laevade üksus" <
[email protected]>
Teema: Re: m/t ATLANTIS (IMO 9268174), Flag of Estonia, Your ref 16.09.2026 nr 17.1-3/26/14214-4
Kuupäev: 2026-10-29 11:44
Dear Sirs,
With reference to Dispensation letter (Your ref 16.09.2026 nr
17.1-3/26/14214-4) issued by the Estonian Flag Administration in
connection with the defective circuit breaker of Auxiliary Engine No. 2
onboard MT ATLANTIS (IMO 9268174), we would like to inform you that
outstanding technical deficiency has been permanently rectified.
The defective circuit breaker has been replaced with a new Schneider
Electric Masterpact NT06H1 unit by a specialized service company.
Installation, commissioning, and operational testing have been
successfully completed. Copy of the Service report attached.
Bureau Veritas subsequently carried out a Remote Survey and confirmed that
outstanding Condition of Class related to the AE#2 circuit breaker has
been deleted, with no further observations to be endorsed. The relevant BV
Survey Statement is attached for your reference.
In view of above, we kindly request the Estonian Flag Administration to
acknowledge the satisfactory rectification of deficiency and confirm
closure or cancellation of related Dispensation, with relevant records
updated accordingly.
Please let us know if any additional documentation is required.
Thank you for your assistance and cooperation.
Kind regards,
Nikolai Sharonov
Fleet Manager
Ocean Fleet Management OÜ
Mobile: +372 5156916
E-mail: <mailto:
[email protected]>
[email protected]
From:
[email protected] <
[email protected]>
Sent: Thursday, September 17, 2026 9:17 AM
To: Nikolai Sharonov <
[email protected]>
Subject: m/t ATLANTIS (IMO 9268174), Flag of Estonia
Hello!
You have received a document through the Estonian Transport
Administration´s document management system.
Title: m/t ATLANTIS (IMO 9268174), Flag of Estonia
Date of registration: 16.09.2026
Number of registration: 17.1-3/26/14214-4.
Please find the document in the attachment.
Transpordiamet
Valge 4
11413 Tallinn
kliendiinfo 620 1200, <mailto:
[email protected]>
[email protected]
<https://www.transpordiamet.ee> www.transpordiamet.ee