KLM Projekt OÜ Siduri 3, Tallinn 11313
Tel: +372 51 44 725
e-post:
[email protected]
Reg. kood: 11074214
MTR reg nr: EEP003312
TÖÖ NR: 2420
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI
REKONSTRUEERIMISE PÕHIPROJEKT
Tellija: Räpina Vallavalitsus
Kontaktisik: Riho Luht
tel: 525 6191
Projekteerija: KLM Projekt OÜ
vastutav projekteerija: Aleksandr Lipkin
kontaktisik: Kristjan Laurits
tel.: 514 4725
TALLINN 2020
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
SISUKORD
I SELETUSKIRI
1 ÜLDOSA ............................................................................................................................ 3
2 OLEMASOLEVA OLUKORRA KIRJELDUS ............................................................................ 4
2.1 OLEMASOLEV OLUKORD .................................................................................................. 4
2.2 GEOLOOGILINE ISELOOMUSTUS ...................................................................................... 5
3 PROJEKTLAHENDUS .......................................................................................................... 5
3.1 ÜLDANDMED ............................................................................................................. 5
3.2 PLAANILAHENDUS ..................................................................................................... 6
3.2.1. Asendiplaaniline lahendus......................................................................................... 6
3.2.2. Liikluskorraldus ........................................................................................................ 10
3.2.3. Kõrguslik lahendus ................................................................................................... 10
3.2.4. Sademevete kanalisatsioon ja drenaaž ................................................................... 10
3.2.5. Välisvalgustus .......................................................................................................... 10
3.3 MULLATÖÖD ............................................................................................................ 10
3.4 KATENDID ................................................................................................................ 11
3.5 TÖÖDE TEOSTAMINE ............................................................................................... 13
3.6 KESKKONNAKAITSE JA MAASTIKUKUJUNDUSTÖÖD ............................................... 15
3.7 KASUTUS- JA HOOLDUSJUHEND .............................................................................. 16
3.8 OLEMASOLEVATE RAJATISTE KAITSMINE ................................................................ 16
II JOONISED NR.
1 ASENDIPLAAN 1
2 LIIKLUSKORRALDUS 2
3 VERTIKAALPLANEERING 3
4 TEHNOVÕRKUDE KOONDPLAAN 4
5 RISTLÕIKED 5.1-5.7
6 SÕIDU- JA JALGVÄRAVAD 6
7 STAADIONI JOONIMISE SKEEM 7
8 KORVPALLIPLATSI JOONIMISE SKEEM 8
9 KÄSIPALLIPLATSI JOONIMISE SKEEM 9
III LISAD
Lisa 1 Ettekasvatatud siirdmuru
Lisa 2 Spordialad
Lisa 3 Välitreeningala
2/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
I SELETUSKIRI
1 ÜLDOSA
Käesolev projekt on koostatud KLM Projekt OÜ poolt Räpina Vallavalitsuse tellimusel.
Rekonstrueerimistööd on kavandatud Põlva maakonnas, Räpina vallas, Räpinas, Kooli tn 5
krundil, kus asub Räpina Ühisgümnaasium.
Projektiga hõlmatud ala haarab järgmised kinnistud:
65 Võru-Räpina tee (70501:004:0438)
Aia tänav T1 (70501:004:0117)
Kooli tn 5 (70501:004:0403)
Võõpsu mnt 16a (70501:004:0105)
Projektlahenduse aluseks on võetud:
Geodeetiliste mõõdistustööde aruanne nr GEO-025-20, Tartu 2020, OÜ WeW
Räpina Vallavalitsuse, Räpina Ühisgümnaasiumi ning Räpina spordiüldsuse esindajate
arvamused ja hinnangud
Maa-ameti leheküljelt leitav ehitusgeoloogiline informatsioon
Suulised geoloogilised andmed
Projekteerimisel on arvestatud järgmiste normide ja nõuetega:
Ehitusseadustik;
Tee projekteerimise normid (MTM 05.08.2015 määrus nr 106);
Tee ehitusprojektile esitatavad nõuded (MTM 02.07.2015 määrus nr 82);
Tee ehitusmaterjalidele ja -toodetele esitatavad nõuded ja nende nõuetele vastavuse
tõendamise kord (MTM 22.09.2014.a määrus nr 74);
Liikluskorralduse nõuded teetöödel (MTM 13.07.2015.a määrus nr 90);
Tee ehitamise kvaliteedinõuded (MTM 03.08.2015.a määrus nr 101);
Teetööde tehnilised kirjeldused, versioon 19.01.2016;
Teatiste, ehitus- ja kasutusloa ja nende taotluste vorminõuded ning teatiste ja taotluste
esitamise kord (MTM 19.06.2015.a määrus nr 67);
Ehitamise dokumenteerimisele, ehitusdokumentide säilitamisele ja üleandmisele
esitatavad nõuded ning hooldusjuhendile, selle hoidmisele ja esitamisele esitatavad
nõuded (MTM 04.09.2015.a. määrus nr 115);
Omanikujärelevalve tegemise kord (MTM 02.07. 2015.a määrus nr 80);
Tee seisundinõuded (MTM 14.07.2015.a määrus nr 92);
Tee ohutuse määramise tingimused ja nõuded tee ohutuse määramisele (MTM
25.06.2015 määrus nr 70);
EVS 901-1:2009 Tee-ehitus. Osa 1: Asfaltsegude täitematerjalid.;
EVS 901-2:2009 Tee-ehitus. Osa 2: Bituumensideained.;
EVS 901-3:2009 Tee-ehitus. Osa 3: Asfaltsegud.;
EVS 901-20:2013 Katsemeetodid. Osa 20: Filtratsioonimooduli määramine.;
EVS-EN 13285:2010 Sidumata segud. Spetsifikatsioon;
EVS-EN 13242:2006 + A1:2008 Ehitustöödel ja tee-ehituses kasutatavad sidumata ja
hüdrauliliselt seotud täitematerjalid.;
EVS-EN 13282-3:2013 Hüdrauliline teesideaine. Osa 3: Vastavushindamine;
3/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
EVS 613:2001/A1:2008 Liiklusmärgid ja nende kasutamine;
EVS-EN 12899:2007 Vertikaalsed liikluskorraldusvahendid;
EVS 614:2008 Teemärgised ja nende kasutamine;
EVS 843:2016 Linnatänavad;
EVS 907:2010 Rajatise ehitusprojekt;
Maa RYL 2010 Ehitustööde üldised kvaliteedinõuded. Pinnasetööd ja alustarindid;
Muldkeha ja dreenkihi projekteerimise, ehitamise ja remondi juhis (MA peadirektori
05.01.2016.a. käskkiri nr 0001);
Killustikust katendikihtide ehitamise juhend (2016-012, MA peadirektori 22.11.2016 nr
0215);
Elastsete teekatendite projekteerimise juhend (2001-52, MA peadirektori 04.03.2002.a
käskkiri nr 31, muudetud MA peadirektori 06.01.2016.a käskkiri nr 0005);
Teehoiutöödel kasutatava killustiku purunemiskindluse määramine (MA peadirektori
18.04.2006.a käskkiri nr 98);
Muldkeha pinnaste tihendamise ja tiheduse kontrolli juhised (MA peadirektori
29.12.2006.a käskkiri nr 264);
Sidumata segust aluskihi mineraalmaterjalist proovivõtu katsemetoodika kehtestamine
(MA peadirektori 30.07.2010 käskkiri nr 230);
Asfaldist katendikihtide ehitamise juhis (MA peadirektori 23.12.2015.a. käskkiri nr
0314);
Teehoiutööde dokumenteerimine ja tööde vastuvõtmine (MA peadirektori 08.07.2003.a
käskkiri nr 99);
Riigimaanteede ehitus- ja remonttööde vastuvõtu eeskiri (MA peadirektori 09.10.2014.a
käskkiri nr 0282);
Teehoolde järelevalve juhend (MA peadirektori 20.02.2015.a käskkiri nr. 49);
Projekti koosseisus antud töömahtude koondtabeli (hinnapakkumuste loetelu) koostamise
aluseks on Maanteeameti poolt väljatöötatud “Teetööde tehnilised kirjeldused (18.02.2019).”
Infot „Teetööde tehniliste kirjelduste“ kohta on võimalik leida Maanteeameti koduleheküljelt:
https://www.mnt.ee/et/ametist/juhendid/teetoode-tehnilised-kirjeldused
2 OLEMASOLEVA OLUKORRA KIRJELDUS
2.1 OLEMASOLEV OLUKORD
Rekonstrueeritav staadion asub Räpinas, aadressil Kooli tn 5. Preagu pole veel tegemist päris
staadioniga, kuid sportimisvõimalused (korvpalliväljakud, ronila, skatepark) seal siiski on.
Tegemist on looduslike kalletega tasase väljakuga, mis kirdest piirneb puistuga, kagust riigiteega
65 Võru-Räpina tee, edelast Aia tänavaga ja loodest ühisgümnaasiumi hoonega. Kinnistul asub
veel olemasolev autoparkla ning asfaltkattega siseteede võrgustlik.
Olemasolevad juurdepääsud on Kooli tänavalt ning Aia teelt. Kirdekülge raamistab
pinnaskattega jalgtee.
Krunt on tagasihoidliku reljeefiga, üldise maapinna langusega kirdest edela suunas; pinna
kõrgusmärgid on vahemikus 38.80-40.94; kusjuures maapinna kalle on võrdlemisi suur kuni
projekteeritava jalgpalliväljaku telgjooneni, edasi muutub kalle olematuks.
4/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
2.2 GEOLOOGILINE ISELOOMUSTUS
Vastavalt geoloogilistele uuringutele paikneb kooli territoorium Võhandu orust umbes 500 m
kaugusel.
Pinnakate koosneb moreenist ja sellel laiguti esinevast jääjärvelisest saviliivast. Pindmises osas
esineb ebaühtlaselt täitepinnas ja muld. Kavandatava staadioni alal esineb pindmise kihina
kasvumuld kuni 0,3 m paksuselt. Koolimaja perimeetris ja olemasolevate katendite piirkonnas
ulatub täitekihi paksus kuni 0,5 m. Saviliiva esineb lokaalselt kohtades, kus ta täidab moreeni
pealispinna ebatasasusi. Kihi paksus 1,3 m.
Moreen on geotehniliste omaduste alusel jaotatud kahte kihti. Ülemises osas esineb
punakaspruun saviliivmoreen, mis on ebaühtlase koostise ja omadustega – pehme- kuni
kõvaplastne. Lõimis tolmne raske saviliiv kuni tolmne kerge liivsavi.
Aluspõhjal lasub kõva saviliivmoreen. Aluskihiks on devoni liivakivi, maapinnast 4,2-5,45 m
sügavusel. Pinnasevett esines 5,5 m sügavusel. Kuna moreen on halbade
filtratsiooniomadustega, esineb kevadeti-sügiseti moreenipealses saviliivas ja täitepinnases
ülavesi, mille eemaldamiseks tuleb staadionile rajada drenaažitrass.
Saviliivmoreeni on lubatud kasutada tagasitäitena staadioni murualadel, ka jalgpalliväljaku all.
3 PROJEKTLAHENDUS
3.1 ÜLDANDMED
Projekteeritava ala pindala on ca 17 700 m2.
5/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
3.2 PLAANILAHENDUS
3.2.1. Asendiplaaniline lahendus
Plaanilahendus on näidatud joonisel 1.
Staadionile on projekteeritud siirdmuruga kaetav, 72x46m jalgpalliväljak; 4-rajaline 300 m
jooksuring, mille tribüünipoolses küljes on 6-rajaline, 110 m tõkkejooksusirge; otsasektoritesse
on kavandatud väljakualade hoovõtusektorid, kõigi katendiks kahekihiline, vett läbilaskev kate
(vt IAAF Track and Fields Facilities manual, lk 92, tabel 3.1.1. sektor A).
Kuulitõuke ja kettaheite ringid on valitud rajada betoonkatendiga; kuulitõukesektori katendiks
on valitud graniitkillustik; kaugushüppekastis on liiv;
Katendite liitumiskohtade (nt tartaanala ja muruala) vaheliseks piirdeelemendiks on valitud
üldjuhul äärekivi 20*8*100 cm.
Tartaani värviks on valitud punane, täpsem värvitooni valik teostatakse kohapeal tootenäidiste
põhjal.
Staadionile on ette nähtud kolm 80-kohalist tribüüni „Väimela“, mis on kuumtsingitud
teraskarkassil kohtpaikne tribüün. Tribüünil 80 – 90 istekohta, konstruktsiooni alune pind 16 x
2,1 m. Astmete osa on kaetud veekindla mittelibiseva vineeriga, istmed sügavimmutatud
puiduga. Trepiastmemooduleid 2, istmeridu 3, ühes istmete moodulis kuni 30 istekohta.
Moodulid on hõlpsasti eraldatavad ja transporditavad; samuti on täielikult (ka moodulite
suuruses) eraldatav käsipuude osa.
Staadion külgneb loode suunast multifunktsionaalse spordiväljakuga, suurusega 40x36 m,
mille katendiks on kunstmuru harja pikkusega 20…24 mm, täiteks liiv. Erivärvilise kunstmuruga
märgitakse maha piirid kahe tennisemängu platsi jaoks (paarismängupiirid 23.78x10.97m),
väravpalli (40x20m) ja futsali jaoks (kusjuures väravpalli 6m joon on identne futsali väravavahi
ala joonega; väravpalliväljaku välispiir sobib futsali välispiiriks).
Väljaku standardvarustusse kuuluvad kaks 3x2m väravpalliväravat; samuti kaks korvilauda, kuid
normaalmõõdus korvpalliplatsi (28.65x15.24m) jaoks on spordiväljak liiga pikk. Võimalik on
korvpalli piirid maha märkida nii, et saaks mängida mõlemal poolel nn ühe-korvi-all-mängu.
6/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
Tenniseväljakute jaoks on vajalik paigaldada võrguposti soklid, mille katteluukidele liimida
lapike kunstmuru. Põhimõtteliselt on võimalik samade soklite abil ka võrkpalli mängida,
milliseks puhuks on vaja maha märkida piirid 9x18 m.
Multifunktsionaalse spordiväljaku piirdeaed on 3,0m kõrgune; postid 100x40x3mm;
vundeerimissügavus 1,0m; külgvärav varustada sillustoruga; 3D paneeli traadi kombinatsioon
8/6/8 mm; silma suurus 200x50 mm; metall kuumtsingitud; iga 1 m tagant horisontaalside
40x40x3 mm.
Multifunktsionaalse spordiväljaku kõrvale on kavandatud asfaltbetoonkattega skatepark
suurusega 31x15m. Olemasolevad skatepargi rambid tuleb korrastada; vajadusel vahetada välja
rampide amortiseerunud elemendid. Skatepargi kõrval olevale haljasalale on jäetud vaba ruumi
liuvälja abihoone (teisaldatav metallkuur põhjapinnaga ca 40 m2), samuti rajatakse vee- ja
elektriühenduse valmidus projekteeritavate katendite ulatuses.
Kooli tn ääres asuva olemasoleva sõiduautode parkla kõrvale kavandati asfaltbetoonkattega 22-
kohaline sõiduautode parkla. Projekteeritava parkla territoorium on plaanis katta
metallpostidele rajatava varikatusega, mille katteelemendiks on valitud päikesepaneelid. Antud
töö raames pakutakse päikeseenergia tootmisjaamale liitumisvalmidus; ehitamise jaoks
koostada tööjoonised vastavalt valitud tootja juhistele.
Allpool olev foto on võetud Hiina tootja kodulehelt http://m.ee.pv-mounting.com/carport-
mounting-system/solar-carport-support-with-solar-panel-system.html
Lisaks on kavandatud parkimisvõimalus staadioni lääneserva. Seal on loodud eeldused
parkimiseks kohalike võistluste kohtunike jaoks. Liikluskorraldus võiks seal jääda vabaks, s.t.
seda ei märgitaks maha. Kogemus näitab, et ürituste puhul, mis algavad ja lõpevad kindlal
kellaajal ja kuhu koguneb hulk ühise eesmärgiga inimesi, on võimalik parkimisala täita autodega
tihedamalt kui tavalise liikluskorraldusega parkla seda võimaldaks.
Staadioni ja nn tennisemaja vahele rajatakse asfaltbetoonkattega korvpalliväljak 28x15.
7/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
Staadionist lõunasse paigutatakse välitreeningala, millel 7 trenažööri ning lastele liivakast
(diameetriga 4 m), kiik Pesa (roheline) ja vedrukiik Skuuter. Valitud trenažööre vt lisa 3. Kõiki
välitreeningala elemente võib ehituse käigus Välitreeningala pind kaetakse EPDM värvilise
kummigraanulitest pealiskihiga 4 cm, värv punane; liivakasti ümbrusse on ette nähtud ka
külvimuru.
8/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
Rekonstrueeritakse kinnistu asfaltkattega siseteed; asendiplaanil on kajastatud
reoveekanalisatsiooni trasside rekonstrueerimisega seotud katendite taastamistööd.
Staadioni ümbritseb kolmest küljest 3D metallpaneel-aed; materjal kuumtsingitud; võrk
200x150x5 mm; aia kõrgus läbivalt 3,0 m. Postiks on valitud 100x40x3 mm; vundeerimissügavus
1,0 m. Aiale on kavandatud kolm väravat. Multifunktsionaalse spordiväljaku värav on osa
standardlahendusest; Kooli ja Aia tn poolsed territooriumi väravad on laiusega 4,5 m
(päästeameti nõue); postid 120x120x3 mm, hinged; jalgvärava lisapost (samm 1,25 m)
100x40x3; kõik väravapooled varustada diagonaalidega.
9/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
Skateparki äärde paigutada jalgrattaparkla Vivid: https://www.dambis.ee/toode/rattaparkla-
vivid/. Jalgrattaparkla mahutab kuni 40 jalgratast. Parkla koosneb viiest moodulist. Vivid
jalgrattaparkla on ilmastikukindel võimalus jalgrattaid hoiustada. Erinevaid mooduleid saab
omavahel ühendada. Kinnitamine toimub vastavalt ankurpoltidega betoneeritud pinnasesse või
koos vastava aluspinnaga.
3.2.2. Liikluskorraldus
Kooli tn poolse sissesõidu keelu märk 331 koos lisatahvliga 891b tõsta joonisel näidatud kohta.
Sama sissesõidu juures oleva parkla territooriumile märkida parkimiskorraldus.
3.2.3. Kõrguslik lahendus
Projekteeritud vertikaalplaneering on näidatud joonisel 2.
Staadioni kõikidele pindadele on antud põikikalle 1%. Maastiku iseloomu tõttu ja ehk ka
seetõttu, et tegemist pole olümpiastaadioniga, on hoovõturadade pikikallete puhul loobutud
IAAF-i nõuete jälgimisest ja lähtutud otstarbekusest.
3.2.4. Sademevete kanalisatsioon ja drenaaž
Sademeveed kogutakse kokku restiga vihmaveerennidega ja restkaevudega ja suunatakse
territooriumi Aia tn poolsel küljel asuvasse külgkraavi. Et saavutada külgkraavi põhjale sobivam
sissevoolu kõrgus, paigutatakse selle põhja betoonist vihmaveerenn.
Rekonstrueeritakse Võru mnt külgkraav. Olemasoleval kraavil puudub ca 100 m pikkusel lõigul
põhja pikikalle ja suubumine Aia tn alusesse truupi asub 10-15 cm truubi suudmest madalamal.
Rekonstrueerimiseks valiti lahendus, mille puhul moodustub nõvalaadne lahendus. Kuna
staadioni perimeeter on varustatud dreeniga, siis loodi eeldused selleks, et staadioni
perimeeter ja jalgpalliväljak on ette nähtud varustada drenaažiga. Drenaaživeed pumbatakse
üle ja suunatakse lõpuks Aia tn külgkraavi. Drenaažipumplast on projekteeritud ka survetoru
Võõpsu mnt 16a kinnistuni eesmärgiga tulevikus suunata Maanteeameti nõusolekul kinnisel
meetodil drenaaživeed Võõpsu maantee ääres paiknevasse lähimasse sademeveekaevu.
Sademevete kanalisatsiooni ja drenaaži lahenduse kohta vt VK projektiosa, koostaja OÜ Smart
Pipes, töö 20027
Jalgpallistaadioni niisutussüsteem rajatakse eraldi projektiga.
3.2.5. Välisvalgustus
Spordiplatside valgustus planeeritakse prožektorvalgustusele (32 tk), mis asetsevad maapinnast
14m kõrgustel mastidel, kinnitatuna traaversitele. Valgustid toimivad kahel režiimil: trenn ja
võistlus, juhtimine projekteeritud lülituskilbist GSM mooduliga.
Tänavavalgustus (loode-kirde suunaline kõnnitee) planeeritakse pollarvalgustitel;
siseterritooriumi üldvalgustus on lahendatud tavalistel mastivalgustitel (viimased on
ühispaigalduses prožektoritega) ja neid juhitakse astronoomilise programmkellaga.
Tänava- ja platside valgustust juhitakse eraldi ja on teineteisest sõltumatud. Lahenduse kohta vt
tänavavalgustuse-elektri projektiosa, koostaja Rünno Bruus
3.3 MULLATÖÖD
Mulde süvend, selle pealiskihi profileerimine ja dreenkiht tuleb teostada vastavalt majandus- ja
taristuministri määrusele „Tee ehitamise kvaliteedi nõuded“ (Vastu võetud 03.08.2015 nr 101).
10/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
3.4 KATENDID
Projekteeritud staadioni rajakate (tüüp 1)
PUR kaitsekiht EPDM graanulitega fr 0,5-1,5 mm, paksus 2 mm
Elastsuskiht musta SBR graanuli (fr 1-4 mm) ja PUR sideaine segu, paksus 10-11 mm
Dreeniv asfaltbetoon PA 8 6,5 cm
Kiilutud killustikalus, 20 cm, põhifraktsioon 32/64, kiilumisfraktsioonid 16/32 ja 8/16,
Liivast dreenkiht, 20 cm, Kt≥0,98, Kf≥2,0 m/ööp
Täiteliiv, 44 cm, Kt≥0,96, Kf≥0,5 m/ööp
II klaasi geotekstiil
Olol pinnas, saviliiv, punakaskollane, plastne
Tartaankattele esitatavad nõuded:
• peab omama Rahvusvahelise Kergejõustikuliidu IAAF-i sertifikaati
• peab olema testitud IAAF-i poolt aktsepteeritud laboratooriumis ja see peab kajastuma
materjali tootja sertifikaadil.
• paigaldamine peab toimuma spetsiaalse laoturiga
• kaitsekiht paigaldatakse pritsemeetodil (spray coat)
• Kogu rajakate peab olema vett läbilaskev.
Tulenevalt tartaankatte paigaldamise nõuetest on vajalik dreenasfaltbetoonist katendikihi
paigaldamisel tagada paigaldatava kihi tasasus järgmiselt: suurim pilu 3 m tasasuslati all katendi
pikisuunas on lubatud 5 mm, katendi põikisuunas on lubatud 3 mm
Projekteeritud siirdemuru (tüüp 2)
Naturaalne sportmuru ettekasvatatud siirdmuruna
Kasvukiht tihendatult, liivast ja turbast segatud kasvusubstraat, 25 cm
Liivast dreenkiht mineraalpinnase kihini, min 25 cm, Kt=0,98, Kf≥2 m/ööp
II klassi geotekstiil
Olol pinnas, saviliiv, punakaskollane, plastne
Projekteeritud külvimuru (tüüp 3)
Murukülv
Kavupinnas, 10 cm
Täiteliiv või olol pinnas
Projekteeritud tõuke- ja heiteringide betoonkate (tüüp 4)
Betoon tugevusklass C30/37, armatuur 8/8/200/200 (koos metallist tugiringi ja
drenaažitorukese paigaldamisega) 10 cm
Kiilutud killustikalus, 20 cm, põhifraktsioon 32/64, kiilumisfraktsioonid 8/16 ja 16/32
Liivast dreenkiht, min 20 cm, Kt≥0,98, Kf≥2,0 m/ööp
Täiteliiv, 44 cm, Kt≥0,96, Kf≥0,5 m/ööp
II klaasi geotekstiil
Olol pinnas, saviliiv, punakaskollane, plastne
Projekteeritud kaugushüppe maandumiskast (tüüp 5)
Peenliiv 50 cm
Täiteliiv
Geotekstiil NGS4
11/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
Olol pinnas, raske saviliivmoreen, sitkeplastne, sis. jämepurdu 5-10%
Projekteeritud kuulitõukesektori killustikkate (tüüp 6)
Graniitkillustik fr. 5-8 25 cm
Geotekstiil NGS4
Liivast dreenkiht, 20 cm, Kt≥0,98, Kf≥2,0 m/ööp
Täiteliiv, 55 cm, Kt≥0,96, Kf≥0,5 m/ööp
II klaasi geotekstiil
Olol pinnas, saviliiv, punakaskollane, plastne
Proj sõidutee asfaltbetoonkate (tüüp 7)
Asfaltbetoon AC 12 surf, 6 cm (45% tardkivimist täitematerjal)
Kiilutud killustikalus, 25 cm, põhifraktsioon 32/64, kiilumisfraktsioonid 16/32 ja 8/16
Liivast dreenkiht, 25 cm, Kt≥0,98, Kf≥2,0 m/ööp
Täiteliiv, 44 cm, Kt≥0,96, Kf≥0,5 m/ööp
II klaasi geotekstiil
Olol pinnas, saviliivmoreen, sitkeplastne, kõvaplastne, sis. jämepurdu 5-10%
Projekt sõidutee ülekate eelneva freesimisega (tüüp 8)
Asfaltbetoon AC 12 surf, 6 cm (45% tardkivimist täitematerjal)
Olol asfaltbetoon või killustikkate
Proj kõnniteede asfaltbetoonkate (tüüp 9)
Asfaltbetoon AC 8 surf, 5 cm
Kiilutud killustikalus, 20 cm, põhifraktsioon 32/64, kiilumisfraktsioonid 16/32 ja 8/16
Liivast dreenkiht, 20 cm, Kt≥0,98, Kf≥2,0 m/ööp
Täiteliiv, 55 cm, Kt≥0,96, Kf≥0,5 m/ööp
II klaasi geotekstiil
Olol pinnas, raske saviliivmoreen, plastne, sis. jämepurdu 5-10%
Proj kõnniteede asfaltbetoonkate (tüüp 10 )
Dreeniv asfaltbetoon PA 8 6,5 cm
Kiilutud killustikalus, 20 cm, põhifraktsioon 32/64, kiilumisfraktsioonid 16/32 ja 8/16,
Liivast dreenkiht, 20 cm, Kt≥0,98, Kf≥2,0 m/ööp
Täiteliiv, 44 cm, Kt≥0,96, Kf≥0,5 m/ööp
II klaasi geotekstiil
Olol pinnas, saviliiv, punakaskollane, plastne
Proj betoonkivisillutis sõiduteel (tüüp11)
Betoonkivi, h=8 cm
Graniitsõelmed fr 0-8 mm, 3 cm
Kiilutud killustikalus, 22 cm, põhifraktsioon 32/64, kiilumisfraktsioonid 16/32 ja 8/16
Liivast dreenkiht, 25 cm, Kt≥0,98, Kf≥2,0 m/ööp
Täiteliiv, 44 cm, Kt≥0,96, Kf≥0,5 m/ööp
II klaasi geotekstiil
Olol pinnas, raske saviliivmoreen, sitke, ja kõvaplastne, sis. jämepurdu 5-10%
12/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
Proj betoonkivisillutis kõnniteel (tüüp 12)
Betoonkivi, h=6 cm
Graniitsõelmed fr 0-8 mm, 5 cm
Kiilutud killustikalus, 20 cm, põhifraktsioon 32/64, kiilumisfraktsioonid 16/32 ja 8/16,
Liivast dreenkiht, 20 cm, Kt≥0,98, Kf≥2,0 m/ööp
II klaasi geotekstiil
Olol pinnas, raske saviliivmoreen, sitke, ja kõvaplastne, sis. jämepurdu 5-10%
Proj killustikkate (tüüp 14)
Sidumata segu nr 6, 7 cm (Tee ehitamise kvaliteedi nõuded, lisa 10)
Olol pinnas
Välitreeningala kummikate (tüüp 15)
EPDM värviline kummigraanulitest pealiskiht 1 cm (vastab 1,5 m kriitilise kukkumise
kõrgusele)
SBR kummigraanulitest aluskiht 4 cm
Kiilutud killustikalus, 20 cm, põhifraktsioon 32/64, kiilumisfraktsioonid 16/32 ja 8/16
Liivast dreenkiht, (Kt = 0,98, Kf >0,5 m/ööp) 20 cm
II klaasi geotekstiil
Olol pinnas, saviliiv, punakaskollane, plastne
Multifunktsionaalse spordiväljaku kunstmuru (tüüp 16)
Kunstmuru harjase pikkusega 24 mm, koos eriliivast täitekihiga
Graniitsõelmed fr 0-8 mm, 3 cm
Kiilutud killustikalus, 20 cm, põhifraktsioon 32/64, kiilumisfraktsioonid 16/32 ja 8/16
Liivast dreenkiht, (Kt = 0,98, Kf >0,5 m/ööp) 20 cm
II klaasi geotekstiil
Olol pinnas, saviliiv, punakaskollane, plastne, 70 cm
Proj looduskividest kate (tüüp 17)
15-20 cm kivisillutis betoonalusel
II klassi geotekstiil
Killustikalus või liivast teemulle
Proj kindlustatud nõlv (tüüp 18)
Kahepoolse pp-võrguga kookosmatt
Murukülv
Kavupinnas, 15 cm
Olol täitepinnas (muld, liiv, pööratud moreen) või saviliiv
3.5 TÖÖDE TEOSTAMINE
Kaevetööde teostamine ja kaevetöödel rikutud maa-ala taastamine teostada vastavalt Räpina
valla heakorraeeskirjale, vastu võetud vallavolikogu määrusega nr 1 (23.01.2013).
Ettevalmistustööd
Geodeetilised tööd
13/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
Hõlmab platside ehituse mahamärkimisega seotud töid. Aluse ja katte ehitusele eelnevalt tuleb
kihi servad tikutada, määrates ära kihi kõrgused olenevalt paigaldusmasinate vajadustest.
Paigaldada ajutised reeperid.
Mullatööd
Kasvupinnase eemaldamine
Kasvupinnas tuleb koorida eraldi ja kasutada samal ehitusel haljastamiseks. Ülejääv
kasvupinnas tuleb toimetada kohaliku omavalitsuse poolt näidatud ladustuskohta.
Süvendi töötlemine
Süvendi töötlemine tuleb teostada täpses vastavuses joonistele (kalded põikprofiilid) või
Ehitusjärelevalve poolt määratule. Aluspinnase pehmed või kahjustunud kohad süvendi põhjas
tuleb parandada materjali väljakaevamise ja selle asendamisega sobiva materjaliga, millel on
ümbritseva materjaliga samad omadused ja tugevus.
Süvendi põhi peab olema nõuetekohaselt tihendatud (tihendustegur 0,95) ja tasane,
projektijärgse kõrguse ja kaldega. Süvendi põhja pinna lubatud kõrvalekalded joonistel näidatud
tasemest on +0 ja –3cm.
Töövõtja peab kontrollima joondamise, kõrguste ja asendi vastavust joonistele oma tööjõu ja
mõõteriistadega. Töövõtja peab hankima mõõdistamiseks vajaliku abimaterjali (vaiad, tikud ja
muu taoline materjal).
Töövõtjal ei ole lubatud kasutada ülemäärase raskusega, aluspinda kahjustavaid
ehitusmasinaid.
Täidendi ehitus
Täidendi põhjale anda projektijärgne kalle, tasandada ja tihendada, tihendustegur 0,95.
Täidend tuleb ehitada projektis nimetatud materjalist ja paigaldada järjestikuliste kihtidena
ristlõike täies ulatuses ja sellises pikkuses, mis sobib mahapanemise ja tihendamise
töömeetoditega. Iga kiht tuleb buldooseri või greideriga või muul sobival viisil ühtlaselt laiali
lükata. Kihi paksus peab vastama tihendamismasina võimsusele, kuid ei tohi ületada 30 cm.
Materjali niiskus peab olema lähedane tihendamiseks sobivale optimaalsele niiskusele. Kui
materjal on liiga kuiv, tuleb lisada vajalikus koguses vett, mis segatakse ühtlaselt pinnasesse.
Kui materjal on liiga märg, tuleb seda õhutada, kuni saavutatakse rahuldav niiskus.
Iga laotatud kiht tuleb tapprulli, pneumorulli ning vibrorulli ja/või muud tüüpi Ehitusjärelevalve
poolt heaks kiidetud tihendamismasinaga hoolikalt tihendada. Tihendamine algab täidendi
madalamalt äärtelt ja suundub edasi kõrgema ääre poole, kusjuures rull peab eelmisest jäljest
vähemalt poole rulli laiuse võrra üle ulatuma. Kogu ala tuleb rullida piisav arv kordi, tagamaks
nõutava tihendusteguri 0,98.
Kihtide põikkalle peab vastama sõidutee projekteeritud põikkaldele
Täidendi pealispinnale anda projekteeritud põikkalle ja tasandada nõutava tasasuseni. Pilu 3m
lati all pikisuunas võib olla maksimaalselt 30mm. Kõrgus ei tohi erineda üle 30mm.
Enne täidendi ehitust peavad maa-alused trassid (dreaanaažtorustik) olema paigaldatud.
Dreenkihi ehitus
Dreenkiht ehitada projektis ettenähtud materjalist. Dreenkiht ehitada eelmises punktis
kirjeldatud viisil.
Dreenkiht tihendada (tihendustegur 0,98). Tihendamise ajal peab dreenkihi materjali niiskus
olema optimaalsele lähedane (vajadusel kuivatada või kasta).
14/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
Dreenkihi paksus ei tohi erineda nõutavast rohkem kui -10%.
Geomeetrilised parameetrid peavad vastama ettenähtule, lubatud on järgmised kõrvalekalded:
plaanis +10cm ja profiilis +3cm.
Aluste ehitus
Killustikaluse ehitus
Killustikalus ehitada kiilumismeetodil. Kõigepealt laotada killustiku põhifraktsioon koguses 80%
koguhulgast ja teostada esialgne tihendamine. Järgneb kiilekillustiku fraktsiooni (20%)
laotamine koos tihendamisega. Kinnikiilumise hõlbustamiseks tuleb rullimisel killustikku veega
kasta (ligikaudu 15…20 l/m2 põhifraktsioonil ja 10…12 l/m2 kinnikiilumisel).
Kihi paksus ei tohi erineda üle 10%. Pilu 3m lati all ei tohi olla üle 8mm, 5% mõõtmistulemustest
võib pilu olla 15mm. Põikkalle võib erineda projekteeritust 0,5%.
Pinna kõrgus võib erineda 20mm.
Aluse tihendamise kvaliteeti kontrollida 10-13t rulli kontrollkäikudega. Seejuures ei tohi alusele
jääda jälge, valtsi ees ei tohi tekkida lainet.
Katete ehitus
Asfaltbetoonkatte ehitus.
Töid võib teha kuiva ilmaga. Kevadel ja suvel peab õhutemperatuur olema vähemalt +5 kraadi,
sügisel +10 kraadi (harilikult 01. juuni ja 15. oktoobri vaheline periood).
Segu koostis peab vastama standardile.
Ettevalmistatud alus tuleb kruntida mitte varem kui 6 tundi enne asfaltbetoonkatte laotamist
bituumenemulsiooni või vedeldatud bituumeniga, norm 0.5...0.8 l/m² bituumenit või 0.7...1.2
l/m² bituumenemulsiooni. Töödeldud ala ei tohi ületada selleks päevaks asfalteerimiseks
planeeritavat ala.
Segu paigaldada laoturiga kogu ühesuguse kaldega laiuses. Laotamine peab toimuma ühtlases
tempos, reguleerides seguri ja laoturi jõudlust nii, et laotamisel ei tekiks vaheaegu. Segu
temperatuuri tuleb kontrollida iga saabuva veoki kastis. Laoturi punkris ei tohi segu
temperatuur olla üle 10 kraadi madalam, kui seda liiki segu madalam lubatud
segamistemperatuur.
Laoturi tööpausid ei tohi ületada 30 minutit, vastasel juhul tuleb jätkata põikvuugi ehitamisega.
Tihendamisega tuleb alustada kohe pärast laotamist. Kihi temperatuur tihendamise alguses
peab olema 120-160o C. Tihendamise lõpul ei tohi temperatuur olla madalam kui 90o C.
Tihendamise tulemusena peab kate saavutama nõutava tiheduse ja tasasuse. Valmis kattel ei
tohi olla rullimisjälgi, pragusid ega sideaine pinnaletõusuga libedaid kohti.
Varem paigaldatud paani serv peab olema korrapärane ning puhas. Jahtunud paani serv tuleb
eelnevalt soojendada või sitke bituumeniga kruntida. Tuleb tagada nõuetele vastava piki- ja
põikvuukide tasasus ja veekindlus.
Tartaankatte ehitus.
Teostada vastavalt tootjapoolsetele juhenditele.
3.6 KESKKONNAKAITSE JA MAASTIKUKUJUNDUSTÖÖD
Haljastus- ja maastikukujundustööd.
Antud töö piires ei lahendata haljastus- ja maastikujundustöid eraldi.
15/16
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMISE PÕHIPROJEKT
KLM PROJEKT OÜ TÖÖ NR. 2420
Keskkonnakaitse
Ehitusjäätmed sorteerida liikidesse ehitusplatsil ning vedada lähipiirkonnas ehitusjäätmete
utiliseerimisega tegelevasse ettevõttesse. Ehitustööd teostada head ehitustava järgides, mitte
kahjustada looduskeskkonda ja elanike elukeskkonna kvaliteeti, tagada turvalisus kogu tööde
teostamise alal. Ehitustööde teostamisel kasutatavate masinate müra ja vibratsioon ei tohi
ületada normidega lubatud nõudeid. Kaevetöödel tuleb järgida ohutusnõudeid, olemasolevate
kommunikatsioonide valdajate või hooldajate poolt seatud piiranguid ning haljastusalaseid
nõudeid.
3.7 KASUTUS- JA HOOLDUSJUHEND
Üldised kasutus- ja hooldusnõuded
Tee kasutamis- ja hooldamisjuhend sõltub tee valdaja ja hoolde tegija omavahelise kokkuleppe
tingimustest. "
Tööde kvaliteet tagatakse ehituse järelevalvega vastavalt: "Omanikujärelevalve tegemise korra
nr. 80, 2015" kohaselt.
Nõuded rajatise kasutajale
Tuleb järgida 01.07.2015.a. jõustunud "Ehitusseadustikku".
Rajatise pikaajalisuse tagab ehitusel kasutatud kvaliteetne tehnoloogia ja sertifitseeritud
ehitusmaterjalide kasutamine ning pidev hooldus.
Jalgpallimuru hoolduse kohta vt Lisa 2
3.8 OLEMASOLEVATE RAJATISTE KAITSMINE
Olemasolevate rajatiste kaitsevööndis teostada kaevetööd käsitsi. Kui kaevetööde käigus tekib
oht olemasolevatele kommunikatsioonidele või rajatistele tuleb ette võtta meetmed nende
kaitsmiseks. Ehitustööde teostamiseks teiste võrguvaldajate võrkude läheduses tuleb järgida
Võrguvaldaja nõudeid võrgu kaitsmiseks ja säilitamiseks.
Elektri maakaabelliini kaitsevöönd on 1m mõõdetuna äärmisest kaablist, siderajatise
kaitsevöönd on 2m siderajatise keskjoonest.
Ehitustöödel jälgida, et peale ehitustöid olemasolevate rajatiste sügavus planeeritud
maapinnast ei väheneks. Vajadusel näha ette elektri- ja siderajatiste viimine sügavamale.
Kaevikute kaevamisel kohtades, mis ohustavad olemasolevaid kommunikatsioone, kaevata V –
kujuline kaevik või toestada kaeviku sein, et vältida vajumisi ja varinguid, mis võivad kahjustada
kaableid. Kaablitega ristumiskohtades tihendada alt täidetav pinnas ümbruses oleva pinnase
tiheduseni ja seejärel katta kaabel nõuetekohaselt
Seletuskirja koostas: Aleksandr Lipkin, 14.09.2020
16/16
TINGMÄRGID
Likvideeritav objekt
Proj asfaldiserv
1.
86
Proj sõidutee betoonäärekivi 30*15*80 (h=10 cm)
00
00
2.
1.
Proj sõidutee langetatud betoonäärekivi, mõlemad suurused (h=2,5 cm)
7
A
HT
pe Proj kõnnitee betoonäärekivi (200x80x1000 mm,h=0)
KO
1. rs
50 ab p. l
22
ih iuv
oo ä
A
ne lja Proj kõnnitee betoonäärekivi (200x80x1000 mm, h=3 cm)
KL
78
0. 0
R
0
PA
2,
7
35
6.
2.
35 SPORTFIX Soft - pehmendusega äärekivi (1000 x 200/400 x 60 mm)
1
x3
15
SPORTFIX Sand - liivakogumismatt (1000 x 500 x 163 mm)
R K
PA
40
00
TE
.0
3.
0
0
Proj renn
.0
A
36
SK
00
3
KÄ
8.
S IP
AL Proj veerenn (Ikodor 400 x 400 x 70 mm)
L
36
x 40 Projekt truup (voolu suunaga)
6
3
5
4
3
4
2
1
2.
88 Projekt nõlv
00
4.
7.
77
0
Olol hoone
0
2.
1.50
4
3.
00 Olol hoone sissepääs
Proj staadioni rajakate (tüüp 1)
50
2.
00
8.
Proj siirdemuru (tüüp 2)
5.
67
R6.00
Proj külvimuru (tüüp 3)
30
2.
1.
02
0
3.0
6
Proj tõuke- ja heiteringide betoonkate (tüüp 4)
50
1.
2 5.
45
Proj kaugushüppekasti liiv (tüüp 5)
6
ÜN
90
x4
Ü
Proj kuulitõukesektori killustikkate (tüüp 6)
2.
IB
72
TR
6
48
6.
AK
LJ
R1.50 Proj sõidutee asfaltbetoonkate (tüüp 7)
VÄ
6.
I
25
LL
2
PA
7. Projekt sõidutee ülekate eelneva freesimisega (tüüp 8)
LG
ÜN
97
Ü
JA
IB
TR
Proj kõnniteede asfaltbetoonkate (tüüp 9)
6
5
1
4
Proj kõnniteede asfaltbetoonkate (tüüp 10 )
3
2
ÜN
1
Ü
7.
IB
51
TR
Proj betoonkivisillutis sõiduteel (tüüp11)
R2.05
0
.0
Proj betoonkivisillutis kõnniteel (tüüp 12)
12
Proj betoonkivisillutis kõnniteel (tüüp 13)
1
Proj killustikkate (tüüp 14)
8.
60
10
.6
0
Proj välitreeningala kummikate (tüüp 15)
5
5.
53 Proj multifunktsionaalse spordiväljaku kunstmurukate (tüüp 16)
1. 2
20 .00
Proj looduskividest kate (tüüp 17)
4.
50 KO
RV Proj kindlustatud nõlv (tüüp 18)
5
R5.0 PA
0 2.
LL 85
8 28 Projekt jalgrattaparkla Vivid (4020 x 2020 mm)
10 .00 x1
.0
A
5
AL
0
G
IN
Proj piirdeaed 3,0 m
EEN
TR
LI
8
VÄ
.5
22
15
.0
ST
8 Proj liiklusmärgi post
A KA
IV
LI
91
3.
Ø
TINGMÄRGID
Likvideeritav objekt
Proj asfaldiserv
Proj sõidutee betoonäärekivi 30*15*80 (h=10 cm)
1
22
Proj sõidutee langetatud betoonäärekivi, mõlemad suurused (h=2,5 cm)
1.
86 Proj kõnnitee betoonäärekivi (200x80x1000 mm,h=0)
00
89
00
2.
1b
1.
Proj kõnnitee betoonäärekivi (200x80x1000 mm, h=3 cm)
loa aja tud
va ar
Vä
ld v a
l
lja
33
1
SPORTFIX Soft - pehmendusega äärekivi (1000 x 200/400 x 60 mm)
A
HT
pe
KO
1. rs
5.
00 50 ab p. l SPORTFIX Sand - liivakogumismatt (1000 x 500 x 163 mm)
22
ih iuv
oo ä
LA
7. ne lja
RK
50
78
0. 0
0
PA
2,
Proj renn
89
35
5.
1b
01
6.
2.
loa aja tud
va ar
Vä
35
1
ld va
l
lja
x3
33
Proj veerenn (Ikodor 400 x 400 x 70 mm)
80
15
1
2.
A RK
Projekt truup (voolu suunaga)
EP
40
00
.0
3.
AT
0
0
.0
36
SK
00
KÄ Projekt nõlv
8.
SI
PA
LL Olol hoone
36
x4
0
Olol hoone sissepääs
2.
88
00
Proj staadioni rajakate (tüüp 1)
4.
7.
77
00
2.
1.50
Proj siirdemuru (tüüp 2)
3.
00
Proj külvimuru (tüüp 3)
50
2.
ND
Proj tõuke- ja heiteringide betoonkate (tüüp 4)
ÖÖ
00
8.
EV
TS
5.
AI
67
Proj kaugushüppekasti liiv (tüüp 5)
EK
R6.00
TE
30
2.
1.
02 Proj kuulitõukesektori killustikkate (tüüp 6)
0
3.0
50
1.
Proj sõidutee asfaltbetoonkate (tüüp 7)
5.
45
Projekt sõidutee ülekate eelneva freesimisega (tüüp 8)
6
N
90
ÜÜ
x4
2.
IB
72
TR
48
6.
Proj kõnniteede asfaltbetoonkate (tüüp 9)
K
JA
ÄL
R1.50
IV
6.
25 Proj kõnniteede asfaltbetoonkate (tüüp 10 )
LL
PA
7.
LG
Ü N 97
Proj betoonkivisillutis sõiduteel (tüüp11)
BÜ
JA
I
TR
Proj betoonkivisillutis kõnniteel (tüüp 12)
1
N
54
ÜÜ
7. Proj betoonkivisillutis kõnniteel (tüüp 13)
IB
US
51
TR
AT
PE
Proj killustikkate (tüüp 14)
R2.05
1
22
0
.0
12
Proj välitreeningala kummikate (tüüp 15)
Proj multifunktsionaalse spordiväljaku kunstmurukate (tüüp 16)
00
5.
8.
60
50
10 Proj looduskividest kate (tüüp 17)
7.
.6
0
00
5.
PE
AT
Proj kindlustatud nõlv (tüüp 18)
US
5. 54
53
1. 2 1
20 .00 Projekt jalgrattaparkla Vivid (4020 x 2020 mm)
)
ee
Proj piirdeaed 3,0 m
4. KO nt
aa
50
RV
m
u
PA
õr
R5.0 Proj liiklusmärgi post
(V
0 2.
L L 85
EE
28
NT
8
10 .00 x1
AA
.0
A
5
AL
M
0
NG
NA
NI
EE
I
ÄP
R
IT
Olol liiklusmärk
-R
8
L
VÄ
.5
0
22
15
12
RU
.0
T
8
AS
VÕ
AK
IV
65
331
LI
91
33
3.
Vä
1
Ø
lja
va ar
ld va
loa aja tud
89
l 4
54 Projekt liiklusmärk
1b
D
ÖN
331
Ö
EV
3a
54
TS
3
17
AI
EK
30
3 Nähtavuskolmnurk
TE
54
1
35
54 5
4
22
44
1
7
5
43 43
5
1
22
44
5
KLM Projekt OÜ Siduri 3, Tallinn 11313
Tel: +372 51 44 725
e-post:
[email protected]
Reg. kood: 11074214
MTR reg nr: TEL001389
TÖÖ NR: 2420-1
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜG
STAADIONI ELEKTRISEADMETE PÕHIPROJEKT
Tellija: Räpina Vallavalitsus
Kontaktisik: Riho Luht
tel: 525 6191
Projekteerija: KLM Projekt OÜ
vastutav projekteerija: Aleksandr Lipkin
kontaktisik: Kristjan Laurits
tel.: 514 4725
TALLINN 2020
SISUKORD
I SELETUSKIRI
1. ÜLDOSA................................................................................................................................ 3
1.1 VALGUSTID........................................................................................................................ 3
2. PROJEKTLAHENDUS ............................................................................................................. 5
2.1 PROJEKTEERITUD TÄNAVAVALGUSTUSE TOITEPUNKTID JA LÜLITUS ............................... 5
2.2 PROJEKTEERITUD SÕIDU- JA KERGTEE VALGUSTUS ...................................................... 5
2.3 PROJEKTEERITUD PALLIPLATSIDE VALGUSTUS .............................................................. 5
2.4 PROJEKTEERITUD PALLIPLATSIDE VALGUSTUSE JUHTIMINE ............................................ 6
2.5 PROJEKTEERITUD MAANDUSED....................................................................................... 6
2.6 PROJEKTEERITUD SEADMETE KAABELLIINID .................................................................... 6
2.7 PROJEKTEERITUD ELEKTRILEVI OÜ KAABELLIINID............................................................. 6
3. TÖÖKIRJELDUSED ................................................................................................................ 6
3.1 EHITUSPLATSI ETTEVALMISTUS ........................................................................................ 6
3.2 MASTIDE JA KAEVUDE PAIGALDUS .................................................................................. 6
3.3 OHUTUSE TAGAMINE JA LIIKLUSE KORRALDAMINE ......................................................... 6
3.4 OLEMASOLEVATE EHITISTE JA RAJATISTEGA ARVESTAMINE............................................ 7
3.5 TÖÖTERVISHOID JA TÖÖOHUTUSNÕUDED ...................................................................... 7
3.6 EHITUSTÖÖDE DOKUMENTEERIMINE JA JÄRELVALVE ..................................................... 7
4. MATERJALIDE SPETSIFIKATSIOON ....................................................................................... 7
5. TÖÖDE MAHUD ................................................................................................................... 8
II JOONISED
1 ASENDIPLAAN J-01
2 TÄNAVAVALGUSTUSE SKEEM J-02
3 LJS VÄLJAKUD SKEEM J-03
III LISAD
1 VALGUSARVUTUS
2 VALGUSTITE TOOTELEHED
3 PAIGALDUSJUHENDID TOOTJATELT
2
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜG STAADIONI ELEKTRISEADMETE PÕHIPROJEKT KLM PROJEKT OÜ TÖÖ NR. 2420-1
_________________________________________________________________________________________________________________
I SELETUSKIRI
1. ÜLDOSA
Käesolev projekt nimetusega „Räpina ÜG staadioni elektriseadmete põhiprojekt“, on
koostatud KLM Projekt OÜ poolt Räpina Vallavalitsuse tellimusel. Projekti eesmärk on
Kooli tn. 5 rajatavate palliplatside valgustamine ja olemasolevate kaablite kaitsmine.
Projekteerimisel on kasutatud järgnevaid alusdokumente:
Geodeetiliste mõõdistustööde aruanne nr GEO-025-20, Tartu 2020, OÜ WeW
Räpina Vallavalitsuse, Räpina Ühisgümnaasiumi ning Räpina spordiüldsuse esindajate
arvamused ja hinnangud
KLM Projekt OÜ poolt koostatud teeprojekt nr. 2420
Projekteerimisel on arvestatud järgmiste eeskirjade ja normidega.
CEN/TR 13201 - 1:2014 Teevalgustus. Osa 1: Valgustusklasside valiku juhised.
EVS-EN 13201 - 2:2015 Teevalgustus. Osa 2: Toimivusnõuded.
EVS-EN 13201 - 3:2015 Teevalgustus. Osa 3: Toimivuse arvutamine.
EVS-EN 13201 - 4:2015 Teevalgustus. Osa 4: Valgusliku toimivuse mõõtemeetodid.
EVS-EN 13201 - 5:2015 Teevalgustus. Osa 5: Energiatõhususnäitajad.
EVS 843:2016 Linnatänavad.
EVS-HD 60364-4-41:2017 Madalpingelised elektripaigaldised. Osa 4-41: Kaitseviisid.
Kaitse elektrilöögi eest.
EVS-HD 60364-4-43:2010 Madalpingelised elektripaigaldised. Osa 4-43: Kaitseviisid.
Liigvoolukaitse.
ELV 10421629-JV ST 5-6 0,4 – 20 kV võrgustandard.
Rajatise ehitusprojekt; EVS 932:2017
EVS-EN 62471:2008. Lampide ja lampseadmete fotobioloogiline ohutus
Madalpingelised elektripaigaldised. Osa 1: Põhialused, üldiseloomustus, määratlused;
EVS-HD 60364-1:2008
Ehitise elektripaigaldised. Osa7: Nõuded eripaigaldistele ja -paikadele. Jagu 714:
Välisvalgustuspaigaldised; EVS-HD 384.7.714:2012
Madalpingelised elektripaigaldised. Osa 5-559: Elektriseadmete valik ja paigaldamine.
Valgustid ja valgustuspaigaldised; EVS-HD 60364-5-559:2013
Ehitusseadustik, (11.02.2015, RT I 05.03.2015.)
RKAS Tehilised nõuded kooli- ja büroohoonetele Osa 10 Elekter
1.1 VALGUSTID
Üldjuhul kasutada leedvalgusteid. Valgusti vandaalikindlus valida vastavalt valgusti
paigalduskõrgusele: 6 meetrit ja kõrgem - IK07, kuni 6 meetrit - IK08, erijuhtudel IK09
kuni IK 10.
Valgustite välisdisain ja värvsustemperatuur peab sobima piirkonnas kasutatavate
teiste valgustitega ja linna keskkonnaga.
Valgusti peab olema kergesti hooldatav.
Valgustid peavad vastama kohalikele kliimatingimustele. (vastavalt ET-2 0102-0329,
„Eesti kliima teatmik ehitajale“).
3
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜG STAADIONI ELEKTRISEADMETE PÕHIPROJEKT KLM PROJEKT OÜ TÖÖ NR. 2420-1
_________________________________________________________________________________________________________________
Valgustite kaitseaste peab olema valitud vastavalt EVS-EN 60529:2001/A2:2014
Ümbristega tagatavad kaitseastmed (IP-kood) ja peab olema vähemalt IP65, IP66.
Juhul kui IP või IK astet muudetakse, siis peab olema selleks projektis väljatoodud
kindel põhjus ja eelnevalt kooskõlastatud täiendavalt tehniliste tingimuste
väljastajaga.
Valgustite ja juhtimisseadmete nimitalitlus peab olema tagatud töökeskkonna
temperatuuril -25 °C kuni +25 °C, valgustite piiratud talitlus peab olema tagatud
töökeskkonna temperatuuril -40 °C kuni +50 °C . Piiratud talitluses töötamine ei tohi
vähendada valgusti eluiga.
Valgusti leedmooduli värviesitusindeks CRI ≥70.
Valgusti nimipinge on 230V. Vastavalt standardi EVS-EN 50160:2010 nõudele peab
valgusti nimitalitlus olema tagatud vahemikus -15 % kuni +10 % nimipinge
väärtusest. Valgusti piiratud talitlus peab olema tagatud pingevahemikus 180 V kuni
277 V. Piiratud talitluses töötamine ei tohi vähendada valgusti eluiga. Valgusti cos φ
peab olema vähemalt 0,9.
Valgusti elektroonikakomponendid peavad vastama I impulsspinge
taluvuskategooriale. Valgustites tuleb kasutada liigpingepiirikut (kaitsetase 1,5 kV,
maksimaalne impulsspinge 10 kV). Liigpingepiirik võib olla paigaldatud valgusti
liiteseadmesse või eraldi plokina masti korpuse sisse.
Valgusti valgusviljakus peab olema vähemalt 90 lm/W värvustemperatuuril 4000 K
ning vähemalt 85 lm/W värvustemperatuuril 3000 K. Magistraalteedel 4000 K ja
muudel tänavatel 3000 K.
Valgustite värvustemperatuur peab olema vahemikus 3000 K kuni 4000 K. Ühe partii
erinevate valgustite värvustemperatuuri vahe võib olla ± 175 kuni 275 K (vastavalt
ANSI C78.377).
Valgusti eluiga peab olema vähemalt L80/alates 60 000 h.
Valgustil peavad olema CE ja ENEC sertifikaadid ning Euroopas tunnustatud
sertifitseerimislabori märgis.
Valgusallikas peab olema läbinud fotobioloogilise ohutuse testi ja vastama EN 62471
nõuetele.
Projektiga koos tuleb esitada valgusti tehnilised andmed ja valgustusarvutuse failid
(*.ies ja pdf formaadis) digitaalsel kujul. Valgustusarvutuse esitamisel tuleb sellel
kajastada objekti andmed (sh aadress, projekti number , arvutuse teostaja).
Valgusti garantii peab olema vähemalt 5 aastat alates paigaldamisest.
Valgusti kõik komponendid peavad olema vahetatavad ja saadaval varuosadena 10
aastat pärast paigaldust. Nõutav on tootjapoolne ametlik dokument.
Valgusti peab olema tehases suletud nõnda, et paigaldaja ei pea objektil valgusti
ühendamisel või paigaldamisel korpust avama. Valgustid tellida tehasest juba piisava
kaablivaruga, et ei peaks objektil valgusti korpust paigaldamisel ja ühendamisel
avama. Valgusti kaabel peab ulatuma terviklikult (ilma lisa ühendusteta) masti
ühendusklemmideni, mis asuvad teenindusluugi ava kohal.
Kõik elektritööd peavad olema tehtud projekti kohaselt ning vastama kehtivatele
normatiividele. Ehitajal on kohustus enne hinnapakkumise tegemist veenduda:
materjalide koguste õigsuses;
tutvuda kohapealsete oludega.
4
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜG STAADIONI ELEKTRISEADMETE PÕHIPROJEKT KLM PROJEKT OÜ TÖÖ NR. 2420-1
_________________________________________________________________________________________________________________
2. PROJEKTLAHENDUS
2.1 PROJEKTEERITUD TÄNAVAVALGUSTUSE TOITEPUNKTID JA LÜLITUS
Käesoleva projekteeritava tänavavalgustuse ja palliplatside toitepunktiks on olemasolev
liitumispunkt koolimajas, millest on projekteeritud toiteliin kaabliga XPJ-HF 5G16 kuni
projekteeriutd lülituskilbini „LJS VÄLJAKUD“. Kaabel paigaldada hoones pindpaigaldusena
järgides „RKAS Tehilised nõuded kooli- ja büroohoonetele Osa 10“. Kaabli läbiviigul hoone
seinas kasutada hülssi, freesauk tihendada veekindlaks. Uus lülituskilp paigaldada sokliga
pinnasesse joonisel J-01 näidatud kohta. Lülituskilp komplekteerida vastavalt skeemile J-
03.
Kilbi ukse siseküljele paigaldada uus täiendatud elektriline skeem. Lisaks on
projekteeritud promenaadi valgustus, mille toitepunktiks on olemasolev valgustimast.
2.2 PROJEKTEERITUD SÕIDU- JA KERGTEE VALGUSTUS
Sõidutee ja kergtee tänavavalgustuse kaabelliin (AXPK) on projekteeritud ühele
väljundgrupile nr. 1 .
Antud gruppide toitel on kasutatud (II klassi) valgusteid võimsusega 52W. Valgustid
paigaldada koonilistele tsingitud 14m prožektormastidele kõrgusele 8m. Kaablid
paigaldada terves ulatuses A-kaitseklassi torusse d=50mm, va. jalandise ülesviik, mis
paigaldada B-kaitseklassiga torusse d=50mm.
Kaabel AXPK 4g16mm2 ühendada mastil olevas teenindusruumis, kasutades klemmide
komplekti SV 15.06. Valgustid ühendada toiteliinile vaheldumisi (järjekorras L1,L2,L3
tagades sellega faaside ühtlase koormamise. Klemmide ja valgustite vaheline ühendus
teostada MCMK4x1,5/1,5 (kaabel valgustile ühendatud tehases).
Käesoleva tänavavalgustuse installeeritud võimsus kokku on 208W, mis jaguneb 3-le
faasile, 4-le valgustile (joonisel tähistega „TV“.
Keskmine arvutuslik valgusheledus sõiduteel on Lm=0.70 (cd/m2).
Valgustuse klass teedel M5. Pingesüsteem 400/230V.
Projekteeritav valgustuslahendus tohi häirida valgusreostuse ega valgusräigusega, peab
olemama maksimaalse valgusvärviga 4000K. Aktsepteeritavad standardi klassid on RG0 (
exempt group) ja RG1 (risk group 1).
Projekteeritud valgustid vastavad kõikidele kehtivatele Euroopa Standarditele ja
Normidele (vt. sertifikaadid käesoleva projekti LISAs valgusarvutuse juures).
2.3 PROJEKTEERITUD PALLIPLATSIDE VALGUSTUS
Palliplatside kaabelliin (AXPK) on projekteeritud kolmele väljundgrupile nr. 2, 3 ja 4.
Antud gruppide toitel on kasutatud prožektorvalgusteid võimsusega 1550W.
Valgustid paigaldada koonilistele tsingitud metallmastidele (h=14m) koos traaversiga.
Kaablid paigaldada terves ulatuses A-kaitseklassi torusse d=50mm, va. jalandise ülesviik,
mis paigaldada B-kaitseklassiga torusse d=50mm.
Kaabel AXPK 4g16mm2 ühendada mastil olevas teenindusruumis prožektoritega,
kasutades universaalklemme KE ja sularit vaskkaablitest allaviikude kaitseks. Valgustid
ühendada toiteliinile vaheldumisi vastavalt skeemile J-02. Klemmide ja valgustite
vaheline ühendus teostada MCMK3x2,5 (L, L, PE).
5
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜG STAADIONI ELEKTRISEADMETE PÕHIPROJEKT KLM PROJEKT OÜ TÖÖ NR. 2420-1
_________________________________________________________________________________________________________________
Käesoleva tänavavalgustuse installeeritud võimsus kokku on 50kW, mis jaguneb 3-le
faasile, 32-le prožektorvalgustile.
Projekteeritud valgustid vastavad kõikidele kehtivatele Euroopa Standarditele ja
Normidele.
2.4 PROJEKTEERITUD PALLIPLATSIDE VALGUSTUSE JUHTIMINE
Tänavavalgustuse juhtimine on projekteeritud vastavalt kilbi skeemile joonisel J-03.
TV fotosilm paigaldada kilbi tagaseina selliselt, et tehisvalgus „silmale“ peale ei paistaks.
Kasutada läbiviigu tihendit. Palliplatside valgustuse juhtimine on projekteeritud vastaval
skeemile, valitud seadmed ja süsteem võimaldab vlgusteid lülitada ja hämardada läbi
võrgu ja ka kohapeal.
2.5 PROJEKTEERITUD MAANDUSED
Mastidele vt. Asendiplaan ja skeem, ehitada maanduspaigaldis, mis vastaks
maandustakistusele R≤30 Ω. Maanduse paljasjuhe asetada 0,7-1,0 m sügavusele ja kaitsta
kaablikaitselindiga. Kaitsemaandusjuhtmeks kasutada vaskjuhet (16mm2). Ühele
kontuurile on arvestatud 2 komplekti maandust.
2.6 PROJEKTEERITUD SEADMETE KAABELLIINID
Sadevee pumpade kaabelliin (MCMK4x4/4) ja Tabloo kaabelliin (MCMK2x2,5/2,5)
ehitada asendiplaani näidatud trassil. Kaablite ühendused teostab käesolea projekti
töövõtja. Ühe sama seadme kaks kaablit võib paigaldada ühte hülssi.
2.7 PROJEKTEERITUD ELEKTRILEVI OÜ KAABELLIINID
Koostatakse eraldi projekt läbi Eletkrilevi Partnerite Portaali -EPP.
3. TÖÖKIRJELDUSED
3.1 EHITUSPLATSI ETTEVALMISTUS
Enne ehitustööde alustamist taotleda ehitusluba ja kaeveluba Räpina Vallavalitsuselt
ning ehitatav trassilõik tellijaga üle vaadata.
Ehitustöödel tekkinud küsimused ja probleemid, mida pole kajastatud käesolevas
projektis või on ebaselged, lahendatakse töö käigus kooskõlastatult projekti autori ja töö
tellijaga.
3.2 MASTIDE JA KAEVUDE PAIGALDUS
Maha märkida mastide asukohad; puurida/kaevata maasse augud; paigaldada jalandid;
tihendada pinnas ümber ja alt; kinnitada mastid jalandil, isoleerida kummiga, ühendada
kaabel klemmkarbis, ühendada valgusti.
3.3 OHUTUSE TAGAMINE JA LIIKLUSE KORRALDAMINE
Ehitustöödega mõjutatav piirkond peab kogu tööperioodi vältel olema tähistatud ja
vastavalt vajadusele ka valgustatud nii, et tööde teostamine ei ohustaks piirkonda
läbivate või seal töid teostavate inimeste elu ja tervist ning vara.
Tänavate sulgemine osaliselt või täielikult sõidukite liikluseks on võimalik ainult vastavalt
omavalitsuspiirkonnas kehtivale korrale.
6
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜG STAADIONI ELEKTRISEADMETE PÕHIPROJEKT KLM PROJEKT OÜ TÖÖ NR. 2420-1
_________________________________________________________________________________________________________________
Tööde teostaja peab arvestama kõigi projekti teostamiseks vajalike tööpiirkonna
tähistamisest tulenevate kulutustega. Tööde teostaja vastutab ajutiste tähiste, piirete ja
liiklusmärkide säilimise ning nende puudumisest tekkinud kahjude hüvitamise eest.
3.4 OLEMASOLEVATE EHITISTE JA RAJATISTEGA ARVESTAMINE
Enne tööde alustamist tuleb tööde teostajal koostöös olemasolevate maa-aluste rajatiste
valdajatega rajatiste asukoht täpsustada ja tähistada. Tööde teostajal tuleb täita
nimetatud rajatiste valdajate poolt esitatavaid nõudeid (näit. Toestamine) rajatiste
vahetus läheduses töötamisel.
Järgida tuleb kõikide kooskõlastusi andnud organisatsioonide nõudeid ning arvestada
neist tulenevate kuludega.
Ehituse ajal tuleb välistada raske transpordi ülesõit torustikust juhul kui seda katva
pinnase või katendikihi paksus on vähem kui 50 cm. Vajadusel kaitsta gaasitorustik
betoonplaatidega. Soovitavalt paigaldada gaasitrassi ümbritsevad katendikihid tee-
ehitustööde alguses.
3.5 TÖÖTERVISHOID JA TÖÖOHUTUSNÕUDED
Tööde teostamisel tuleb järgida Eesti Vabariigi seadustega ja määrustega sätestatud
nõudeid.
3.6 EHITUSTÖÖDE DOKUMENTEERIMINE JA JÄRELVALVE
Tööde teostamise kohta koostatakse kaetud tööde aktid. Kõik kõrvalekalded projektis
fikseeritakse vastavates protokollides ja kooskõlastatakse objekti projekteerijaga ning
tellijapoolse ehitusjärelvalve teostamisega.
4. MATERJALIDE SPETSIFIKATSIOON
NIMETUS MARK/TÄHIS KOGUS MÜ
Maakaabel AXPK4g16 1150 m
Maakaabel XPJ-HF 5G16 50 m
Maakaabel MCMK4x4/4 300 m
Maakaabel MCMK2x2,5/2,5 240 m
Maakaabel CAT6 10 m
Kaablikaitsetoru B-klass, d=50mm 50 m
Kaablikaitsetoru A-klass, d=50mm 1500 m
Kaablikaitsetoru A-klass, d=110mm 60 m
Kaabli märkelint 1500 m
Sõrmikotsamuhv,
termokahanev, 1kV EPKT 18 tk
plastkaablile
Maanduskomplekt (üks
FS 11, FS 21, 2x(FS 31) 3 tk
kontuur = 2kompl.)
Maandusklemm C6 7 tk
Maandusjuht, vask Cu-16mm² 100 m
LED Prožektor 1550W/202870 lm 5200K IP66 AAA-LUX 20 tk
7
PÕLVA MAAKOND, RÄPINA VALD, RÄPINA ÜG STAADIONI ELEKTRISEADMETE PÕHIPROJEKT KLM PROJEKT OÜ TÖÖ NR. 2420-1
_________________________________________________________________________________________________________________
NIMETUS MARK/TÄHIS KOGUS MÜ
WS2506.4.00.00 Staadioni valgustus
LED Prožektor 1550W/202870 lm 5200K IP66 AAA-LUX WS-
12 tk
STAD-03-06 v6.0.0, Tennis, korvpall valgustus
G6 Offset Bracket for G6 luminaires 32 tk
Control-box 2.0 2017 (incl antennebox), Staadioni valgustus 1 tk
InControl SB Simple Outdoor use and RF comm to lights. Pre
1 tk
defined scenes
Prožektormast CP18000F-223+TS330-000F 8 tk
Betoonjaland SJL-6L 14-18m mastile 8 tk
Pollarvalgusti Bocaro 4051859158202 6 tk
Pollarvalgusti Bocaro jalg 4051859160496 6 tk
LED valgusti Mini Martin 52 W, CRI>70, 4000 K, lens 09, RAL
4 tk
9006, NTD, L=8m 5x1.5mm2 toitekaabliga
Erikonsool 0,5m / 60mm vitskinnitusplaadiga koonilisele
4 tk
mastile
Lülituskilp (sokliga) (komplekteerida vastavalt skeemile) 1 kompl
Lülituskilp (sokliga) Reservkilp, kombipesaga 1 kompl
Tabloo 230V wifi 1 tk
Gsm ruuter +antenn 4G 1 kompl
Avatav toru D160 (2poolt) 460 m
5. TÖÖDE MAHUD
TEOSTATAV TÖÖ Kokku Mü
TÄNAVAVALGUSTUS/SEADMED
Metallmast traaversiga h=14m, ja seadmetega 8 kompl
paigaldus
Lülituskilp sokliga + tugevvoolu ühendused 2 kompl
Valgustite paigaldus 32+4+6 tk
Maanduskontuuride ehitus 3 tk
Kaevetrassi kaevamine proj. kaablitele 850 m
Pinnase äravedu /tagasitäide 350 m3
Täitedokumentatsioon vastavalt kehtivale 1 kompl
Ehitusseadustikule ja Seadme ohutuse seadusele
Koormusvoolude mõõteprotokoll 1 kompl
Elektripaigaldise nõuetekohasuse hindamine ja 1 kompl
tõendamine
Elektripaigaldise audit 1 kompl
Mastide demonteerimine/utiliseerimine 5 kompl
Seletuskirja koostas: Rünno Bruus
8
00 Proj kõnnitee betoonäärekivi 20*10*100 (h=5 cm)
41,
,90
40
80
SPORTFIX Soft - pehmendusega äärekivi (1000 x 200/400 x 60 mm)
40,
40,70
4
4 0,70
40 0,60
40 0,60
4 ,5
4 0, 0
0
40 40 0,3040
,5
4
40
40,
10 ,0 ,20
0 40,
30
SPORTFIX Sand - liivakogumismatt (1000 x 500 x 163 mm)
00 40,
40, 20
0
39,9 40,
90 10
39, 40,
00
Projekteeritud kombipesaga
39,
8 0 lülituskilp -LJS Uisuväljak- 40, Proj renn
7 39 39,
90
80
,80 39,
70
39,
60
39,
10
39,
50 Proj veerenn (Ikodor 400 x 400 x 70 mm)
,
0
0
40
39 39,9 430
,0
,7 39, 9,42
40
,9 0
0
80
Reservtoru ots
,80
39,
39
70
39
,70
39
75
39,
,6 9
3 Projekt truup (voolu suunaga)
,60
39 1 2
39 0
1 ,60 ,5
39
2
3
Projekt nõlv
0
,4
2
1
39
3
9,7
0 0
,4 39 9,4
3 39 ,4 2
3 0
2 329 1 1
,50
39
,60 Olol hoone
3
2
39,4 0 5
5 ,5 1 ,4
39 39
39,4
Olol hoone sissepääs
0 39,45
0
,4
39
39,3
5 39,4
23 4
0 0 Proj staadioni rajakate (tüüp 1)
3
1 ,4 5
1
39 9,4
3
3
39,
4
39,35
1
23 30 39
2 ,4 2
3 5
1 3
39 Proj siirdemuru (tüüp 2)
,40
2 1
2 ,35
39
Projekteeritud lülituskilp -LJS Väljakud- 39, 1
25 0
39 39,3
,4 39,3
0 1
2 0 Proj külvimuru (tüüp 3)
39, 3
4
20 3
5
2 1
,5
39
1
39,50 39
,3 2 3
4 2
Proj tõuke- ja heiteringide betoonkate (tüüp 4)
39,4 0
2 3 39, 5 3 3
15 4
391
3 ,5 0
1
39,
9
2 1 2
1
,2
0
4 5
39,6 0
5
39
39,7 0
,3 1 2 ,20 4 1
0 39
Proj kaugushüppekasti liiv (tüüp 5)
39,8 0
39, 39, 3 3 2
40 10
39,9 0
41
40,0 0
5 ,2
2
,10
3 39
3 4 2
40,1 0
39, 2 3
39
3
1 1
2
3
9,
1
5
40,2 0
,15
1
Proj kuulitõukesektori killustikkate (tüüp 6)
10
39 3 4 ,30
40,3 0
3 4
,2 2 39
2 39 5 1
39,30
40,4 0 39,35
2 1
1 ,2 40,0
0
40,5
39
3
,35
9,1
,1 39 0
40,6
,325
5 1
,1 5 2
41,10
39
0
392 120 39,80 Proj kinnistusiseste teede asfaltbetoonkate, ka katendi taastamine (tüüp 7)
40,70
39 20 39,30
2
,1
41
,
39
0
39
40,80
5
, 2 1 3 40 41,10
,2
3
,15
39 25 39, 60
25 ,
0
40,90
39,
1 1 23
39
3 4
6
, 4
39,30 ,10
2 39 4
41,0
5
1 39,25 3 1 3
41,00
39 ,40
1 2 2
1
39 Projekt sõidutee ülekate eelneva freesimisega
2
0
23 4
39,20
2
39,30
2 3
1
39 9,15
1
39,15 2
40,90
3
,1
5
,20
,2
1 3
0
39
39
39,10 1
2 Proj kõnniteede asfaltbetoonkate (tüüp 8)
0
3 4
,2
329,051
39
40
39
,80
39 6
,2
,10
0
39
2 2 3
Proj kõnniteede asfaltbetoonkate (tüüp )
39
,15 1
1 3
,2
5
1
23 4 3 4
39
2 2
,3
1 1
39 ,20
0
Proj kõnniteede tänavakattekivi, ka katendi taastamine (tüüp 9)
0
39
2
,1
39
40,7
,3
,10
5
2
0
39
39
1 3
,4
5
Proj sõiduteede tänavakattekivi, ka katendi taastamine (tüüp 10)
,4
0
1
39
2 2 3
39
,4
1
0
,4
5
39
5
2
5
Proj killustikkate (tüüp 10)
,2
,3
0
39
39
1 2
,2
1
39
1 3
2
0
39
1
,3
1
39
,
2 3
20
2 2
1
1
Proj välitreeningala kummikate (tüüp 11)
5
1
,2
39
2
5
3
1
0
39,
,2
39
39
39 ,20
2
39,3 1
Proj multifunktsionaalse spordiväljaku kunstmurukate (tüüp 12)
,2
5
0
39
1
0
,1
2 2 3
20
39,3
39
1
0
39,
,2
39,35
5
39,2 2 3
5
39,25
1
Proj looduskividest kate (tüüp 13)
2
3
39,30
1
39ühendused
Sadevee pumpade ,20
1
5
1
39,30
3 4 2 3
2 2 4 2
1
1 2 1 3 39,43 1
2 1 0
39,1
5 2
3
4
Proj kindlustatud nõlv (tüüp 13)
39
39,25
1
2 3 ,35
2 3
39,25
39,20
3 4 1
2 15 1 2
1
4
3 39
,30 Projekt jalgrattaparkla Vivid (4020 x 2020 mm)
39,25
2 3
1
39,30
39,20
39
5
2 3
2 ,25
1
0
1 39,25 23
,2
39,10
3
39 4
39
1 2
39,30 ,20 1
39,20
12 3
25
1 2 2 3
4
9,
2 1
30
,10
3
3
39,30
39 1 2 3
5
39,3
1
9, 3
39
,20 2 34
39,20
35 1
39 9,
39,40
,25 3
39, 5
,20
39
0 39,25
30
4 2
5
9, 39 1
,2
39
3
2
3 ,4 3
1 0
39,30 39
,3 39,30 39,30
5
1
39 3
2
,3 39,35
0
39,30 3 39,40 39,40
,3
39
39,35 ,30
39 39 Asfaltkattega sõidutee all
,35
39,30
,20
39,25 39
,10
39
Haljasala all
Projekti nr. TP1131 TINGMÄRGID
Proj.tud k/p kaabel
Proj.tud m/p kaabel
Proj.tud jätkumuhv (info viidal)
Proj.tud demonteeritav
Proj.tud MAANDUS
Proj.tud kaablitrass, kuni 4 kaablit trassis
Proj.tud reservtoru d110
Proj.tud maakilp sokliga
Demonteeritav
Proj.tud pollarvalgusti (RGB)
Proj.tud tänavavalgusti konsooliga
Proj.tud prožektormast (4 valgustit traaversil)
Proj.tud prožektormast (5 valgustit traaversil)
Proj.tud prožektormast (7 valgustit traaversil)
Proj.tud prožektormast (2 valgustit traaversil)
Proj.tud tabloo 230W (wifi)
Proj.tud maandus
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
SISUKORD
JOONISTE NIMEKIRI ...................................................................................................................................3
1. Üldosa ...............................................................................................................................................4
1.1. Üldandmed ....................................................................................................................................4
1.2. Lähteandmed.................................................................................................................................4
1.3. Normdokumendid ..........................................................................................................................4
2. Veevarustuse välisvõrgud .................................................................................................................4
2.1. Torustike materjalid .......................................................................................................................4
2.2. Kaevik ............................................................................................................................................4
2.3. Tasanduskiht .................................................................................................................................4
2.4. Torustiku paigaldus ja kaeviku täide .............................................................................................5
2.5. Külmumiskaitse ja soojusisolatsioon .............................................................................................5
2.6. Hüdraulilised katsetused ...............................................................................................................5
3. Reoveekanalisatsiooni välisvõrgud ...................................................................................................5
3.1. Projekteeritud reoveekanalisatsioon .............................................................................................5
3.2. Torustike materjalid .......................................................................................................................6
3.3. Kaevud ..........................................................................................................................................6
3.4. Kaevik ............................................................................................................................................6
3.5. Tasanduskiht .................................................................................................................................6
3.6. Torustiku paigaldus ja kaeviku täide .............................................................................................7
3.7. Torustike paigaldus eritingimustes ................................................................................................7
3.8. Hüdraulilised katsetused ...............................................................................................................7
4. Sademekanalisatsiooni ja drenaaži välisvõrgud ...............................................................................7
4.1. Arvutuslik vooluhulk .......................................................................................................................7
4.2. Eelvool ...........................................................................................................................................7
4.3. Projekteeritud sademeveekanalisatsioon ......................................................................................8
4.4. Pumpla ..........................................................................................................................................8
5. Nõuded materjalidele ja seadmetele .................................................................................................8
5.1. Üldnõuded .....................................................................................................................................8
5.2. Kanalisatsioon ja drenaaž .............................................................................................................8
5.2.1. Polüvinüülkloriid (PVC) torud ja liitmikud...................................................................................8
5.2.2. Polüpropüleen (PP) torud ja liitmikud ........................................................................................8
5.2.3. Polüetuleen (PE) drenaažitorud ja liitmikud ..............................................................................9
5.2.4. Tihendid ja määrdeained ...........................................................................................................9
5.2.5. Sademeveekanalisatsioonikaevud ............................................................................................9
5.2.6. Drenaažikaevud .........................................................................................................................9
5.2.7. Kaevukaaned ja raamid, kaped .................................................................................................9
6. Kaevetööd .........................................................................................................................................9
6.1. Kaevetöödele esitatavad põhinõuded ...........................................................................................9
6.2. Kaeviku kaevamine .......................................................................................................................9
6.3. Toru aluse, tasanduskihi rajamine...............................................................................................10
6.4. Ehituskaeviku tagasitäide ............................................................................................................10
6.4.1. Üldist ........................................................................................................................................10
6.4.2. Algtäide ....................................................................................................................................10
6.4.3. Lõpptäide .................................................................................................................................11
6.5. Torude ja toruarmatuuri paigaldamine ........................................................................................11
7. Katsetused ja kontrolltoimingud ......................................................................................................12
7.1. Isevoolsete torustike videouuring ................................................................................................12
7.2. Isevoolsete torustike kontrollimine ..............................................................................................12
8. Keskkonnakaitsemeetmed ..............................................................................................................12
8.1. Ehitusjäätmed ..............................................................................................................................12
8.2. Haljastuse kaitsmine....................................................................................................................12
PÕHIMATERJALIDE SPETSIFIKATSIOON ...............................................................................................13
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 2 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
JOONISTE NIMEKIRI
JOONISE NR JOONISE NIMI KUUPÄEV MÕÕTKAVA
VVK-1 VÄLISVÕRKUDE ASENDIPLAAN 11.09.2020 1:500
VVK-2 REOVEEKANALISATSIOONI PIKIROFIIL 11.09.2020 1:500: 1:50
VVK-3 REOVEEKANALISATSIOONI PIKIROFIIL 11.09.2020 1:500: 1:50
VVK-4 SADEMEVEEKANALISATSIOONI PIKIROFIIL 11.09.2020 1:500: 1:50
VVK-5 SADEMEVEEKANALISATSIOONI PIKIROFIIL 11.09.2020 1:500: 1:50
VVK-6 DRENAAŽI PIKIROFIIL 11.09.2020 1:500: 1:50
VVK-7 DRENAAŽI PIKIROFIIL 11.09.2020 1:500: 1:50
VVK-8 SURVEKANALISATSIOONI PIKIROFIIL 11.09.2020 1:500: 1:50
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 3 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
1. Üldosa
1.1. Üldandmed
Kinnistule on projekteeritud staadion koos jooksuraja ja palliplatsidega ning tuletõrjeveemahutid.
1.2. Lähteandmed
Projekti koostamisel on aluseks järgmised lähteandmed:
Geodeetiline alusplaan, WEW OÜ, Töö nr.: GEO-025-20; 07.02.2020
1.3. Normdokumendid
Projekteerimisel kasutatud normdokumendid:
EVS 848:2013 Väliskanalisatsioonivõrk;
EVS 921:2014 Veevarustuse välisvõrk;
RIL 77-2013 – Plasttorude paigaldusjuhend projekteerijale ja ehitajale;
EVS-EN 1610:2015 Äravoolu- ja kanalisatsioonitorustike ehitamine ja katsetamine.
2. Veevarustuse välisvõrgud
Perspektiivse liuvälja kastmisvee saamiseks on projekteeritud veetorustik mis tuleb lõpetada
el.keevispimedataega (jätkatakse järgnevate projektidega).
2.1. Torustike materjalid
Kõik torustike rajamiseks kasutatavad materjalid peavad olema uued. Materjale tuleb transportida,
ladustada, virnastada, jne vastavalt tootja juhistele ja nõuetele. Defektsed materjalid ja tooted tuleb
ehitusplatsilt eemaldada.
PE survetorud peavad vastama standardi EN12201 nõuetele.
2.2. Kaevik
Kaevik teha võimalikult kitsas, võttes arvesse võimalike tugitarindite jaoks vajalikku laiust, töötamisruumi
ja seda, et torustiku ümber paiknevat algtäidet saaks nõuetekohaselt tihendada. Teostamata kaeviku
põhja minimaalne laius on 1.0m ja vähemalt 0.4 m laiem toru läbimõõdust. Kaeviku laiuse ja torude
vahekauguse määramisel tuleb arvestada torude läbimõõtu, läbimõõtude ja paigaldussügavuste erinevust
ning tihendamisel kasutatavate mehhanismide mõõtmeid.
Kaevik teha nõlvade püsivuse parandamiseks kalletega. Nõrkades pinnastes tuleb kaeviku põhi kaevata
käsitsi või väiksema mehhanismiga, et vältida aluspinnase rikkumist ning ebaühtlase paksusega aluse
kujunemist. Töötamisel allpool pinnasevee taset eemaldatakse vesi.
Hoone vundamentide vahetus läheduses teostatavate kaevetööde puhul talvistes tingimustes tuleb
tarvitada meetmeid vundamentide aluse pinnase läbikülmumise vältimiseks.
Torustikukraavide kaevandamisel peab kanalites olema vaba ruumi vähemalt järgmiselt:
torude alla 100 mm;
torude kõrvale 200 mm;
kaevude ümber 300 mm.
2.3. Tasanduskiht
Kaeviku põhja, täitepinnase kihi või aluse peale teha tasanduskiht, mille kõrgus toru sirge osa põhjast
mõõdetuna on vähemalt 150 mm (muhvi alla peab jääma vähemalt 100 mm). Tasanduskiht
peenefraktaioonilisest killustikust.
Tasanduskihina kasutatava kivimaterjali suurim lubatud fraktsioon (dmax) sõltub paigaldatava toru
välisläbimõõdust (de).
Suurim osakeste suurus (prEN 1046):
de < 110 15mm;
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 4 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
110 de < 315 20mm.
Tasanduskihi materjal peab olema osakeste suuruse poolest võimalikult lähedane aluse ja algtäite (ja
ümbritseva loodusliku pinnase) materjalile, et vähendada nende segunemise ohtu.
Aluskiht tihendada 98% tihedusastmeni vältides pinnase rikkumist. Enne kaevikute täitmist tuleb
torustikud esitada tellija esindajale ülevaatuseks.
2.4. Torustiku paigaldus ja kaeviku täide
Torude leidmise hõlbustamiseks ning kaevetöödel nende kahjustamise vältimiseks tuleb veetorustike
paigaldamisel torustiku külge kinnita asukoha määramiseks min 2,5mm² ristlõikega isoleeritud
vaskkaabel, pinnasesse jäävad kaabli jätkud peavad olema veetihedad. Kaabli otsad tuua
veemõõdusõlme ja tänaval kape alla. Veetoru kohale umbes 0,4 m kõrgusele paigaldada sinine märkelint
kirjaga “Ettevaatust veetorustik”.
Algtäide (sängituskiht, külgtäide)
Nõuded on üldiselt samad, mis tasanduskihil. Algtäide de160 torude korral peab ulatuma vähemalt
300mm toru ülaservast kõrgemale. Sängitusmaterjali tihendada kihiti. Esimene kiht võib ulatuda
maksimaalselt toruläbimõõdu kõrguseni. Vajadusel võib torustiku tihendamistööde ajaks täita veega. Otse
torude peal olevat sängitusmaterjali tohib mehhanismidega tihendada alles siis, kui kiht on vähemalt
300mm paksune, kuid tihendusvõtteid kasutades peab kihi paksus olema vähemalt 150mm.
Lõpptäide
Liikluspiirkonnas peab lõpptäitematerjal olema 98%tihendatav. Väljaspool liikluspiirkonda võib lõpptäite
jätta tihendamata või siis tihendada see vastavalt kohalikele tingimustele. Kaevik tuleb täita sellise
kõrguseni, et täide hiljem tihenedes jääks planeeritud kõrgusele või maapinnaga ühele tasemele.
Toru ülaservast mõõdetuna 1 meetri paksuses lõpptäitekihis ei tohi olla üle 300 mm läbimõõduga kive
ega kamakaid.
Enne kaevikute täitmist tuleb torustikud esitada tellija esindajale ülevaatuseks.
Ehitusjärgsed vajumid peavad jääma lubatud piiridesse.
2.5. Külmumiskaitse ja soojusisolatsioon
Veetorustikud paigaldada maapinna külmumispiirist allapoole. Toru peal pinnase paksus vähemalt 1,8m.
2.6. Hüdraulilised katsetused
Paigaldatud torustikud tuleb katsetada vastavalt EN 805-le. Töövõtja eraldab vajaliku tööjõu, paigaldab
kogu katsetamise seadmestiku ja ankurdab selle nii, et oleks võimalik läbi viia kõik ettenähtud katsetused.
Plasttorudele HDPE on nõutav kaks katsetust:
eelkatse: torustiku nimirõhul, kestvus enam kui 12 tundi;
põhikatse: otsekohe pärast eelkatse lõppu, kestvus 3 tundi, proovirõhk 1, 5 kordne torustiku töörõhk,
kuid mitte alla 8 bar (PN10 torustiku puhul).
3. Reoveekanalisatsiooni välisvõrgud
3.1. Projekteeritud reoveekanalisatsioon
Osaliselt rekonstrueeritakse kinnistul paiknevad amortiseerunud torustikud ja vaatluskaevud.
Torustiku lõik kaevust K21-13 kuni OK-2 on ette nähtud rekonstrueerida kinnisel meetodil.
Kinnistu torustik on ette nähtud ehitada plastmass jäikusklass SN8 torudest.
Vaatluskaevudeks kasutada reoveekanalisatsioonis plastik teleskoopkaevusid Ø400/315 ja Ø560/500, 40T
kandevõimeliste metallkaantega.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 5 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
Plastist kontrollkaevude ehitamisel kasutatakse kaevuelemente: kaevupõhjad koos sisseehitatud
toruühendusmuhvidega ja teleskoopseid pikendusi.
Kaevudes peavad olema poole torustiku läbimõõdu kõrgused voolurennid.
3.2. Torustike materjalid
Lahtisel meetodil rajatavate isevoolsete reoveekanalisatsiooni torustike ehitamiseks tuleb kasutada
ühekihilisi siledaseinalisi PVC või PP torusid.
PVC torud ja toruliitmikud peavad olema toodetud vastavalt Euroopa standardile EN 1401. PVC torud
peavad olema ühendatavad muhvotsliitega, rõngasjäikus SN8, varustatud kummitihenditega.
Toruliitmikud (kolmikud, põlved, otsakorgid, jne) peavad vastama samale standardile kui torudki ning olema
valmistatud sama tootja poolt.
3.3. Kaevud
Reoveekanalisatsioon kasutada vaatluskaevudeks kasutada plastik teleskoopseid keeviskaevusid 40T
kandevõimeliste metallkaantega.
Plastist kontrollkaevude ehitamisel kasutatakse kaevuelemente: kaevupõhjad koos sisseehitatud
toruühendusmuhvidega ja teleskoopseid pikendusi.
Kui joonistel ei ole teisiti määratud, peetakse kinni plastist kaevudele esitatavatest nõuetest. Kaevudes
peavad olema poole torustiku läbimõõdu kõrgused voolurennid.
3.4. Kaevik
Kaevik teha võimalikult kitsas, võttes arvesse võimalike tugitarindite jaoks vajalikku laiust, töötamisruumi ja
seda, et torustiku ümber paiknevat algtäidet saaks nõuetekohaselt tihendada. Teostamata kaeviku põhja
minimaalne laius on 1.0m ja vähemalt 0.4 m laiem toru läbimõõdust. Kaeviku laiuse ja torude vahekauguse
määramisel tuleb arvestada torude läbimõõtu, läbimõõtude ja paigaldussügavuste erinevust ning
tihendamisel kasutatavate mehhanismide mõõtmeid.
Kaevik teha nõlvade püsivuse parandamiseks kalletega. Nõrkades pinnastes tuleb kaeviku põhi kaevata
käsitsi või väiksema mehhanismiga, et vältida aluspinnase rikkumist ning ebaühtlase paksusega aluse
kujunemist. Töötamisel allpool pinnasevee taset eemaldatakse vesi.
Hoone vundamentide vahetus läheduses teostatavate kaevetööde puhul talvistes tingimustes tuleb tarvitada
meetmeid vundamentide aluse pinnase läbikülmumise vältimiseks.
Torustikukraavide kaevandamisel peab kanalites olema vaba ruumi vähemalt järgmiselt:
torude alla 100 mm;
torude kõrvale 200 mm;
kaevude ümber 300 mm.
3.5. Tasanduskiht
Kaeviku põhja, täitepinnase kihi või aluse peale teha tasanduskiht, mille kõrgus toru sirge osa põhjast
mõõdetuna on vähemalt 150 mm (muhvi alla peab jääma vähemalt 100 mm). Tasanduskiht teha peene
fraktsioonilisest killustikust.
Tasanduskihina kasutatava kivimaterjali suurim lubatud fraktsioon (dmax) sõltub paigaldatava toru
välisläbimõõdust (de).
Suurim osakeste suurus (prEN 1046):
de < 110 15mm
110 de < 315 20mm
Tasanduskihi materjal peab olema osakeste suuruse poolest võimalikult lähedane aluse ja algtäite (ja
ümbritseva loodusliku pinnase) materjalile, et vähendada nende segunemise ohtu.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 6 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
Aluskiht tihendada 98% tihedusastmeni vältides pinnase rikkumist. Enne kaevikute täitmist tuleb torustikud
esitada tellija esindajale ülevaatuseks.
3.6. Torustiku paigaldus ja kaeviku täide
Algtäide (sängituskiht, külgtäide)
Nõuded on üldiselt samad, mis tasanduskihil. Algtäide de110 torude korral peab ulatuma vähemalt 300mm
toru ülaservast kõrgemale. Sängitusmaterjali tihendada kihiti. Esimene kiht võib ulatuda maksimaalselt
toruläbimõõdu kõrguseni. Vajadusel võib torustiku tihendamistööde ajaks täita veega. Otse torude peal
olevat sängitusmaterjali tohib mehhanismidega tihendada alles siis, kui kiht on vähemalt 300mm paksune,
kuid tihendusvõtteid kasutades peab kihi paksus olema vähemalt 150mm.
Lõpptäide
Liikluspiirkonnas peab lõpptäitematerjal olema tihendatav. Väljaspool liikluspiirkonda võib lõpptäite jätta
tihendamata või siis tihendada see vastavalt kohalikele tingimustele. Kaevik tuleb täita sellise kõrguseni, et
täide hiljem tihenedes jääks planeeritud kõrgusele või maapinnaga ühele tasemele.
Toru ülaservast mõõdetuna 1 meetri paksuses lõpptäitekihis ei tohi olla üle 300 mm läbimõõduga kive ega
kamakaid.
Enne kaevikute täitmist tuleb torustikud esitada tellija esindajale ülevaatuseks.
Surveta torud ühendatakse kummitihenditega muhvühendustega. Ühendused teha toru valmistaja poolt
esitatud juhiste kohaselt. Vajaduse korral tuleb tihendid puhastada vee või nõrga soodalahusega. Tihendite
paigaldamisel võib kasutada neid libisemist soodustavaid aineid, mis on soovitatud tihendite valmistaja poolt.
Ehitusjärgsed vajumid peavad jääma lubatud piiridesse.
Konkreetseid geoloogilisi uuringuid ei ole teostatud, kuid antud piirkonna varasema uuringud näitavad, et
tegemist on paepinnasega.
3.7. Torustike paigaldus eritingimustes
Eritingimused puuduvad.
3.8. Hüdraulilised katsetused
Isevoolsete kanalisatsioonitorustike veepidavuskatsed tuleb läbi viia vastavalt EVS-EN 1610-le. Pärast
katsetusi ühendatakse torustikulõik süsteemiga.
Isevoolsete plasttorustike ovaalsust kontrollitakse, kui Tellijal on kahtlusi, et toru ristlõike kuju on paigalduse
ja täite tegemise käigus muutunud rohkem kui tootja poolt lubatud. Lubatud maksimaalne ovaalsus
plasttorudel on 8% peale paigaldamist
Kaevude tihedust kontrollitakse visuaalsel vaatlusel. Kui osutub vajalikuks, tuleb kaevude veetiheduse
katsetamine teha vastavalt SFS 3113 ja SFS 3135-le.
4. Sademekanalisatsiooni ja drenaaži välisvõrgud
4.1. Arvutuslik vooluhulk
Kinnistu vooluhulk:
platsid 55 l/s
drenaaz 8 l/s.
4.2. Eelvool
Kinnistu sademevee eelvooluks Aia tänava ääres asuv rekonstrueeritav kraav (teede projekti osa) ning
drenaaži eelvooluks on Võpsu mnt sademeveekanalisatsiooni torustik. Võõpsu maantee alt läbiv ja
Võõpsu mnt 16a kinnistut läbiv torustik on ette nähtud paigaldada kinnistel meetodil (lahendakase eraldi
projektiga).
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 7 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
4.3. Projekteeritud sademeveekanalisatsioon
Kinnistult tulevad sademeveed on ette nähtud kokku koguda ja juhtida Aia tänava kraavi. Kinnistu
torustik on ette nähtud ehitada plastmass jäikusklass SN8 torudest. TORUSTIKUD MILLE
PAIGALDUSSÜGAVUS ON MADALAM KUI 70cm TULEB VIGASTAMISE VÄLTIMISEKS KAITSTA
BETOON PLAADIGA MILLE PAKSUS 10CM JA LAIUS 1.0m.
Vaatluskaevudeks kasutada reoveekanalisatsioonis plastik teleskoopkaevusid Ø400/315 ja Ø560/500,
40T kandevõimeliste metallkaantega.
Plastist kontrollkaevude ehitamisel kasutatakse kaevuelemente: kaevupõhjad koos sisseehitatud
toruühendusmuhvidega ja teleskoopseid pikendusi.
4.4. Pumpla
Kuna isevoolselt ei ole võimalik drenaažvett ära pumbata, siis projekteeritud 1 täisautomaatne
drenaažveepumpla. Projekteeritud pumplakorpus on kavandatud kas PEHD (kõrgsurve polüetüleen)
lehtplastist või -spirotorudest ehitatavad ühekambrilised ja koonuselise põhjaga (pumpla korpuspeab
olema valmistatud min SN4 kN/m² jäikusklassist). Pumplasse on ette nähtud juhtsiinidel allalastavad
kiirkinnitusega drenaaživee sukelpumbad. Vajadusel töötavad pumbad paralleelselt korraga. Pumpla
varustatakse redeli, katteluugi ja õhustustorudega Ø110mm ning komplekteeritakse automaatkilbiga ja
vajalike kaablitega. Pumpla elektri- ja automaatikakilp paigaldada pumpla kõrvale. Pumpade
survetorustikele paigaldatakse sulgemisarmatuur ja tagasilöögiklapp. Pumpla tarnida varustatakse
andur- ja alarmsüsteemiga – häiried GSM võrku (kilp paigaldada pumpla kõrvale).
Pumpla on ühekambriline ja 1600mm läbimõõduga. Pumpla projekteeritakse kahe pumbaga.
Ühe pumba parameetrid:
Qa=8,0 l/s
H= 11.0m.
Ühe pumba ligikaudne elektrivõimsus on ca 2,5 kW.
Pumbad käivitub kui ujuklüliti tõuseb käivitustasemeni ja seiskub kui ujuklüliti alaneb seiskamistasemeni.
5. Nõuded materjalidele ja seadmetele
5.1. Üldnõuded
Kõik alalise töö tegemisel (püsivasse kasutusse) kasutatavad materjalid peavad olema uued. Materjale
tuleb transportida, ladustada ja virnastada vastavalt tootja juhistele ja nõuetele. Defektsed materjalid ja
tooted tuleb ehitusplatsilt eemaldada ja asendada Töövõtja kulul.
5.2. Kanalisatsioon ja drenaaž
5.2.1. Polüvinüülkloriid (PVC) torud ja liitmikud
Polüvinüülkloriid (PVC) torud ja liitmikud peavad vastama standardile EN 1401-2-2000 või EN 13476.
Torud ja liitmikud peavad olema klassiga SN8. Torud ja liitmikud ühendatakse elastsete tihenditega
muhvliidetega. Veekindlate toruliitmike ühendamine toimub vastavalt torutootja juhenditele. Igal juhul
tuleb tihend, muhvi või liitmiku sisemus, eriti servatav pind (kui just ei paigaldata püsivat tihendit) ja muhv
puhastada enne ühendamist mustuse ja muude kõrvalainete eemaldamiseks lapi, messingi või
paberkäterätiga.
Tihend, muhvi servad, servatav pind ja tihenduspind tuleb üle kontrollida, et ei esineks vigastusi või
deformatsiooni. Kui tihendid ei ole paigaldatud tehase poolt, siis tuleb kasutada vaid neid tihendeid, mis
on mõeldud ja tarnitud koos antud toruga. Tootja soovitab kasutada kaasapandud tihendeid.
5.2.2. Polüpropüleen (PP) torud ja liitmikud
Polüpropüleen (PP) torud ja liitmikud peavad vastama ühele järgmistest standarditest: EN 1852-1:1998,
EN 13476 või SFS 3453.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 8 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
PP torud ja liitmikud peavad olema klassiga SN8.
5.2.3. Polüetuleen (PE) drenaažitorud ja liitmikud
Dreenitoruna kasutada jäika PE ehitusdreenitoru Ø110÷160 mm, augustatud täisring, rõngasjäikus SN8.
Torud peavad vastama vastavas standardile SFS 3520.
5.2.4. Tihendid ja määrdeained
Survetorustike liitmike, siibrite ja maakraanide puhul kasutatavad tihendid peavad olema valmistatud
etüleen-propüleen-dieenkummist (EPDM) ja vastama standardile BS 2874.
Isevoolsete torustike ühendusmuhvides ja liitmikes kasutatavad NBR tihendid peavad vastama
standardile SS 367612 ja SBR tihendid standardile SS 367611.
5.2.5. Sademeveekanalisatsioonikaevud
Sademeveekaevudele kehtivad reoveekanalisatsiooni kaevudele esitatavad nõuded koos käesolevas
punktis kirjeldatud erisustega. Kaevud ei pea olema varustatud voolurennidega. Restkaevud peavad
olema 560/500 läbimõõduga ja varustatud 0.6m settekotiga.
5.2.6. Drenaažikaevud
Drenaazikaevudele kehtivad reoveekanalisatsiooni kaevudele esitatavad nõuded koos käesolevas
punktis kirjeldatud erisustega. Kaevud ei pea olema varustatud voolurennidega. Kaevud peavad olema
minimaalselt 400/315 läbimõõduga ja varustatud 0.2m settekotiga.
5.2.7. Kaevukaaned ja raamid, kaped
Kaevukaaned ja nende raamid peavad olema tempermalmist (DIN 1693). Kaevud ja nende kaaned
peavad sobima kasutamiseks teede all ja olema “ujuva” paigaldusega. Liikluspiirkonnas asuvate
kaevude kaante tugevus peab vastama normi EN124 klassile D400 (kandejõud 400 kN), väljaspool
liikluspiirkonda võib kasutada kandejõuga 250 kN kaasi.
Kaevude kaaned tuleb paigaldada teekattega samale kaldele.
PE-kaevu kaane suurus valitakse vastavalt kaevu läbimõõdule.
Kaevuluugid ei tohi kolksuda.
6. Kaevetööd
6.1. Kaevetöödele esitatavad põhinõuded
Kaevetöödel juhinduda Tellija tingimustes esitatud nõuetest ja tingimustest, kohaliku omavalitsuse
ettekirjutustest, järelevalveinseneri (edaspidi Insener) poolt esitatavatest nõuetest.
Kaevetööd hõlmavad kogu selle pinnase väljakaevamist olenemata selle olemusest, mis on vajalik tööde
teostamiseks. Kaevetööd on lubatud kaeveloa alusel.
Ülejääv ehituskaevikust väljakaevatud materjal tuleb ehitusplatsilt eemaldada, keskkonnaohutu materjali
ladustamine lepitakse kokku Tellijaga.
Kaevetöid teostatakse nende piiride, tasapindade, ulatuste ja sügavusteni, mis on ära märgitud joonistel
või spetsifikatsioonides või määratud Inseneri poolt. Juhul kui ei ole võimalik kinni pidada projektis
esitatust, tuleb teha projektimuudatus ja saada selleks Inseneri heakskiit.
6.2. Kaeviku kaevamine
Maa-aluste torustike, kaevude ja pumplate kaevikute kaevetöödel tuleb järgida projektjooniseid ja nõutud
täpsusega järgida seal esitatud suundasid, pikkusi ja kõrgusi.
Töövõtja kaitseb ja toestab kõiki maa-aluseid rajatisi (torustikud, kaablid jm), et need säilitaksid oma
esialgse positsiooni. Tööde planeerimisel tuleb arvestada, et maa-aluste rajatiste avamine ja nende
vahetus läheduses kaevetööde teostamine tuleb reeglina teha käsitsi.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 9 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
Üldjuhul tehakse ehituskaevik võimalikult kitsas, võttes arvesse võimalike tugitarindite jaoks vajalikku
laiust, töötamisruumi ja seda, et torustiku ümber paiknevat algtäidet saaks nõuetekohaselt tihendada.
Ehituskaeviku ristlõige (ehituskaeviku nõlva kalle) selgitatakse konkreetsel töölõigul Töövõtja poolt
sõltuvalt antud asukohas valitsevatest geoloogilistest tingimustest.
Kitsastes oludes kasutada kaevetöödel väikemehhanisme.
Ehituskaeviku sügavuse määramisel peab juhinduma EVS-EN 1610:2007 „Dreenide ja
kanalisatsioonitorustike ehitamine ja katsetamine“, mille kohaselt torustiku alla tehakse vähemalt 150
mm paksune tasanduskiht.
Töövõtjal tuleb ehituskaevik rajada nii, et kõik ohutusnõuded oleksid tagatud. Kaevikud kaevata
sissevarisemist vältiva kaldega või selle ohu korral sügavusel ≥1.8 m või allpool pinnaseveetaset
teostada tugiseintega. Ehituskaeviku toestamisel on soovitav kasutada tehases valmistatud tugikilpe ja
vahetugesid. Viimased võib eemaldada alles siis, kui see ei sea ohtu töötajaid või kaevikusse
paigaldatud kommunikatsioone. Ehituskaeviku toestamise vajadus konkreetsel töölõigul otsustatakse
Töövõtja poolt sõltuvalt tööde teostamise ajal valitsevatest ehitustingimustest ja kooskõlastatakse
Inseneriga.
Kaevik hoida torustiku paigaldamise ajal vaba pinnaveest. Veetõrjetööde vajadus ja aeg sõltub
veetasemest pinnases ehitustööde ajal ning pinnase omadustest konkreetsel kaeviku lõigul.
6.3. Toru aluse, tasanduskihi rajamine
Toru aluse, tasanduskihi rajamisel tuleb juhinduda standardist EVS-EN 1610:2007 „Dreenide ja
kanalisatsioonitorustike ehitamine ja katsetamine“. Tasanduskiht tehakse ehituskaeviku põhja.
Tasanduskiht peab olema vähemalt 0,4 m laiem kui toru läbimõõt. Tasanduskihi tihendusaste peab
olema vähemalt 90% ja tihendamine peab olema tehtud mehhanismidega kogu kaeviku laiuselt.
Sõltuvalt geoloogilistest tingimustest tehakse toru alus, tasanduskiht ehituskaeviku põhja paigaldatud
peenefraktsioonilisest killustikust fraktsiooniga 2…16 mm, kihi paksus on 150 mm. Materjal ei tohi
sisaldada orgaanilisi ja kahjulikke aineid ning savi või liivsavi (kas eraldi või kokku) rohkem kui 15%
materjali kaalust. Materjal peab olema tihendatav.
Torustiku alus ei tohi olla torustiku paigaldamisel läbikülmunud. Pehmete pinnaste korral paigaldada
tasanduskihi alla geotekstiil.
6.4. Ehituskaeviku tagasitäide
6.4.1. Üldist
Ehituskaeviku tagasitäidet tohib teostada ainult pärast kooskõlastamist Inseneriga ning tagasitäite
tegemisel juhinduda Tellija tingimustes ja EVS-EN 1610:2007 esitatud juhistest ja nõuetest.
Ehituskaeviku täitmine toimub ettevaatlikult ja kihtide kaupa. Töövõtja säilitab tagasitäite säilimise
määratud tasapinnal ja tagab, et tagasitäidetud pinnas oleks rahuldavas olukorras kogu projekti
elluviimise perioodil. Vajumise korral pärast tagasitäite tegemist täidetakse kaevik sama klassi
materjaliga ja hoitakse täide nõutud kõrgusel. Kui vajumine võib osutuda ohtlikuks inimestele, rajatistele
või sõidukitele, siis tehakse taastäitmine samal päeval, kui vajumist märgati või kui sellest informeeriti
Töövõtjat. Kui vajumine toimub suures ulatuses ja viitab kehvale tihendamise kvaliteedile, siis kaevab
Töövõtja kaeviku lahti vajaliku sügavuseni ja tihendab kaeviku uuesti vastavalt nõutud standarditele.
Külgtäite ja tagasitäite paigaldamist võib alustada vaid siis, kui toru ühendused ja aluskiht võimaldavad
koormamist. Tagasitäitmist, sealhulgas alg-ja lõpptäite paigaldamist, kaeviku tugistuse eemaldamist ja
tihendamist tuleb teostada viisil, mis tagab torustiku kandevõime vastavuse projekteerimisnõuetele.
Enne tagasitäitmist peab veenduma, et kaevikus ei ole lahtist mulda, prügi, vett. Tagasitäitena on
keelatud kasutada külmunud materjali, mis sisaldab jääd.
6.4.2. Algtäide
Algtäite all mõeldakse toru ja kaevu ümber tasanduskihi peal kasutatavat materjali. Algtäide peab torude
puhul ulatuma 300 mm toru ülaservast kõrgemale.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 10 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
Algtäidet tuleb paigaldada viisil, mis takistab oleva pinnase sissevajumist või täitematerjali segunemist
oleva pinnasega. Täidet tuleb kaitsta igasuguste ettenähtavate kandevõime, stabiilsuse või paigutuse
muutuste eest, mida võivad põhjustada kaeviku toestuse eemaldamine, pinnaseveetase, muud
külgnevad kaevamistööd.
Täite paigaldamise ajal tuleb eritähelepanu pöörata torustiku suuna ja kõrguse paigaltnihkumise
vältimisele.
Algtäite tegemisel asetatakse materjal samaaegselt enam-vähem samale kõrgusele mõlemale poole
toru, kaevu, alustuge, tugisammast või silda. Toru ja kaev peavad säilitama oma esialgse asukoha ja
kalde. Kaeviku täitmine külgedelt toimub ettevaatlikult ja mitte paksema kui 150 mm täitekihiga. Esimene
täitekiht võib ulatuda maksimaalselt poole torukõrguseni.
Töö esimesel etapil lükatakse täide laiali labidatega või muul viisil ning tihendatakse nii, et õigele
kõrgusele paigaldatud toru ei nihkuks paigast ega saaks kahjustatud. Kaeviku algtäide tehakse ja
tihendatakse homogeense kihina ka toru pikisuunas, eriti oluline on seejuures toru alumist poolt toetava
täitekihi hoolikas tihendamine.
Algtäide tehakse liivast. Materjal peab olema homogeenne, puhas, ühtlane ning osakesi, mis on
väiksemad kui 0.02 mm peab olema vähem kui 10%. Materjal ei tohi sisaldada orgaanilisi ja kahjulikke
aineid ning savi või liivsavi rohkem kui 15% materjali kaalust. Materjal peab olema tihendatav.
Iga kiht tihendatakse eraldi käsitsi kuni kuivtihedusaste saavutatud on vähemalt 95%
maksimumtihedusest. Kui toru ei asu liikluspiirkonnas ja uute teede all, siis peab tihendusaste olema
vähemalt 90%.
6.4.3. Lõpptäide
Ülejäänud tagasitäide, lõpptäide kuni maapinnani asetakse kaevikusse 300 mm kihtidena ja
tihendatakse. Torude puhul, mille välsmõõt on Ø200 ei rakendata tugevat tihendamist kuni 300 mm
kõrguseni toru ülaservast. Suuremate torude puhul on see kõrgus 500 mm.
Liikluspiirkonnas peab lõpptäitematerjal olema tihendatav. Liikluspiirkonnas tuleb üldjuhul kasutada
juurdeveetavat, lõpptäiteks sobivat pinnast. Kui kaevikust väljakaevatud pinnas on sobiv ja Insener selle
heaks kiidab, võib väljakaevatud pinnast kasutada lõpptäiteks ka liikluspiirkonnas. Väljaspool
liikluspiirkonda võib lõpptäiteks kasutada kaevikust väljakaevatud pinnast või juurdeveetavat lõpptäiteks
sobivat pinnast. Tihendamine tuleb sooritada kihtide kaupa. Toru ülaservast mõõdetud 1,0 m paksuses
lõpptäitekihis ei tohi olla üle 300 mm läbimõõduga kive ega kamakaid. Lõpptäite ülaosas ei tohi kivide
läbimõõt ületada 2/3 ühekorraga tihendatava kihi paksusest. Täitematerjal peab olema mitmekesise
teralise koostisega, et täitesse ei jääks tühimikke.
Liikluspiirkonnas tuleb lõpptäide tihendada vastavalt teekatte konstruktsioonile, so asfaltbetoonkatte
korral 98% maksimumtiheduseni ja killustikkatte korral 95% maksimumtiheduseni.
Väljaspool liikluspiirkonda (haljasaladel) on soovitav lõpptäide tihendada 90% maksimumtiheduseni või
juhinduda Inseneri ettekirjutustest. Kaevik tuleb täita sellise kõrguseni, et täide hiljem tihenedes jääks
planeeritud kõrgusele või maapinnaga ühele tasemele.
Kui tihendusaste on väiksem kui nõutud, siis tehakse täiendav tihendamine ning uut tagasitäitematerjali
kihti ei paigaldata enne, kui eelnevalt paigaldatud materjali kiht on nõuetekohaselt tihendatud. Kui
tihendusaste ei ole ikkagi vastuvõetav, siis eemaldatakse tagasitäitematerjal 150 mm paksuselt kuni
eelmise vastuvõetava tihendusastmega kihini ning tehakse täiendav tihenda-mine, kuni saadakse
rahuldav tulemus. Alles seejärel pannakse kaevikusse uus tagasi-täitematerjali kiht.
6.5. Torude ja toruarmatuuri paigaldamine
Toruarmatuuri paigaldamisel tuleb lähtuda tootjate poolt koostatud kasutus- ja paigaldusjuhenditest.
Paigaldamisel on lubatud järgmised kõrvalekalded projektis märgitud asukohast:
horisontaalkaugus projekteeritud asukohast ± 100 mm;
vertikaalkaugus projekteeritud asukohast ± 50 mm;
maksimaalne lubatud kõverus kaevude vahel on ± 1/300 kaevude vahekaugusest;
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 11 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
kaevu seina lubatud hälve vertikaalist 5 mm/m;
rajatud torustiku langu lubatud erinevus projekteeritust kaevude vahelisel lõigul on projekteeritud
langu 5 ‰ ja rohkem korral 1.5 ‰, projekteeritud langu 3 - 5 ‰ korral 1.0 ‰.
Kõrvalekalded projektlahendusest on lubatud järgmistel eeldustel:
teiste projekteeritud torustike paigaldamine ei saa takistatud;
tagatud on minimaalne projektis märgitud paigaldussügavus;
kaevu suubuva isevoolse toru põhi ei jää madalamaks kaevust väljuva toru põhjast;
torustik jääb kogu pikkuses isevoolselt tühjenevaks.
7. Katsetused ja kontrolltoimingud
7.1. Isevoolsete torustike videouuring
Peale ehituskaeviku lõplikku tagasitäitmist, kuid mitte varem kui 10 päeva on möödunud lõpliku
tagasitäite tegemisest, tuleb Töövõtjal kõik isevoolse kanalisatsioonitorustiku lõigud äbi pesta veega,
kasutades selleks spetsiaalset survepesurit, et eemaldada torustikku ehituse käigus sattunud liiv, kivid,
mustus, jms.
Vahetult peale torustiku survepesu tuleb kõikide isevoolsete kanalisatsioonitorustiku lõikudele teha
videouuring torustiku paigaldusjärgse seisukorra väljaselgitamiseks.
Tellijale üleantavate eksemplaride arv ja formaat lepitakse kokku Tellija ja Töövõtja vahel.
7.2. Isevoolsete torustike kontrollimine
Kui isevoolsete torustike videouuringu alusel tekib kahtlus torustiku paigaldamise kvaliteedis, tuleb
kahtlusi tekkinud lõikudes teha torustiku deformatsiooni kontrollimine mõõtsilindriga.
Deformatsiooni piirväärtus sõltub eelkõige toru materjalist. Torustiku deformatsioon ei tohi ületada
standardis SFS3135 määratud suurusi Vastavalt standardile SFS 3135 on PE torude paigaldamisjärgne
suurim lubatud ovaalsusaste 2% ja toru ristlõike suurim lubatud kujumuutus pärast paigaldamist on 8%.
Kui torustiku vastuvõtmisel tehtud deformatsioonimõõtmiste tulemused ületavad standardis esitatud
piirväärtusi, tuleb selgitada põhjused ning esitada põhjuste analüüsi tulemused Insenerile. Seejärel
otsustatakse, kuidas igal konkreetsel juhul toimida, kas jätkata torude deformatsiooni mõõtmisi ja milliste
ajavahemike tagant.
8. Keskkonnakaitsemeetmed
Ehituse käigus tuleb järgida keskkonnakaitse reegleid.
8.1. Ehitusjäätmed
Ehituse Töövõtja vastutab ehitusperioodil keskkonnakaitse eest ehitusplatsil ja sellega vahetult piirnevail
aladel vastavalt Eesti Vabariigis kehtivaile seadustele ja nõuetele ning Tellija poolt esitatud juhistele.
Tähelepanu tuleb pöörata ehitustöödel tekkivate jäätmete käitlusele. Ohtlikud jäätmed tuleb koguda
muudest jäätmetest eraldi ning üle anda ohtlike jäätmete käitlemise litsentsi omavatele ettevõtetele.
Ehitusjäätmete kogumine ja utiliseerimine on ehitaja kohustus.
8.2. Haljastuse kaitsmine
Kaevetöö tegemisel säilitatavate puude läheduses, kus võib olla tegemist kergesti variseva pinnasega,
rajatakse tugiseinad, mis väldivad juurestiku kahjustumist pinnase nihkumise tagajärjel. Kaevetööga seotud
alal piiratakse üksikpuud või puude ja põõsaste grupid piki juurestiku kaitseala piiri ajutise piirdeaiaga.
Kaevetöö tegemisel juurestiku kaitsealal paigaldatakse puudele tüvekaitsed ning kaevetöö tehakse kas
käsitsi sügavamal kui 1m. Tehnovõrkude paigaldamist segavate üle 4cm läbimõõduga puujuurte
läbilõikamine kooskõlastatakse keskkonnaametiga. Peenemad juured lõigatakse läbi sirgelt terava
lõikevahendiga. Kuivaperioodil kastetakse kahjustatud juurtega puid ning paljastunud juured kaetakse
kuivamise vältimiseks. Liiklemise või materjalide ladustamise vajadusel juurestiku kaitsealal kaetakse
maapind viisil, mis välistab pinnase tihenemise. Kaevetööd segavate puude raie ning okste kärpimine on
lubatud vaid keskkonnaameti poolt väljastatud kirjaliku loa alusel.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 12 / 13
TELLIJA: KLM PROJEKT OÜ
TÖÖ NIMETUS: RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE
AADRESS: KOOLI TN 5, RÄPINA, RÄPINA VALD, PÕLVA MAAKOND OÜ Smart Pipes
TÖÖ NR: 20027
OSA: VEEVARUSTUS JA KANALISATSIOON
STAADIUM: PÕHIPROJEKT
PÕHIMATERJALIDE SPETSIFIKATSIOON
Jrk. Materjali nimetus Tüüp Mõõt- Kogus Märkus
nr. ühik
VEEVARUSTUS
1. PE survetoru Ø32 PN12.5 m 20
2. Maakraan koos spindlipikenduse ja kapega DN25 kompl 1
3. Elekterkeevis üleminek 32 tk 2
REOVEEKANALISATSIOON
Plastmass kanalisatsioonitoru, SN8 Ø110 m 7
4. Ø160 m 213
Ø200 m 123
5. Kinnisel meetodil rekonstrueeritav torustik Ø200 m 79
Kanalisatsioonikaev, plastmass, teleskoopne ja Ø400/315 kompl 13
6.
kaanega 40T Ø560/500 kompl 4
SADEMEVEEKANALISATSIOON JA DRENAAŽ
Plastmass kanalisatsioonitoru SN8 Ø110 m 172
Ø160 m 196
7. Ø200 m 79
Ø250 m 87
Ø315 m 43
Drenaažitoru SN8 Ø110/100 m 1085
8.
Ø160/140 m 294
9. PE survetoru Ø110 PN10 m 155
Kontrollkaev (plastmass, teleskoopne ja Ø400/315 kompl 16
10.
malmkaanega 40T) Ø560/500 kompl 6
Drenaažikaev (plastmass, teleskoopne ja Ø400/315 kompl 18
11.
malmkaanega 40T, setteosa 20cm) Ø560/500 kompl 1
Restkaev (plastmass, teleskoopne ja
12. Ø560/500 kompl 6
malmkaanega 40T, setteosa 60cm)
Muru restkaev (plastmass, teleskoopne ja
13. Ø560/500 kompl 1
malmkaanega 40T, setteosa 60cm)
Drenaažipumpla h=4.70m 2 pumpa (a´ Q=8.0
14. Ø1600 kompl 1
l/s, H=11m, N=2.5 kW).
15. Rennkanal V100, malmrestiga C250, 1 äravool L=17m kompl 2
Rennkanal V200, malmrestiga C250, 1 äravool L32m kompl 1
16.
L=47m kompl 1
17. Rennkanal V200, malmrestiga C250, 3 äravoolu L=81m kompl 1
Loetelus on toodud põhimaterjalid. Kui joonistel kujutatud tööde teostamiseks on vajalikud
spetsifikatsioonis mittetoodud materjalid, kuuluvad need töövõtu sisse. Täiendavalt arvestada
välisvõrkudel kaevikute tagasitäide jms. Kanalisatsioonitorustike monteerimisel kasutada laugeid
ühendusdetaile. Spetsifikatsioonis toodud kogused tuleb töövõtjal üle kontrollida ja vajadusel täpsustada
enne hinnapakkumuse tegemist.
Majaka tn 44-9, Tallinn, Harjumaa, 11412 11.09.2020
[email protected] Vastutav spetsialist: Veiko Loorents
tel +372 526 8802
MTR EEP001966, EPE000622 13 / 13
40.68
38.85
KEEVISPIME Ø32
PERSPEKTIIVNE VEEÜHENDUS
PEØ32 PN12.5
L=18.5m
39.79
37.96
MK-1
39.65
K21-1 39.12 W
Tingimärgid
W
1. MAAKRAAN DN25
2
1
W V1
2
39.12 W 2 39.83
2
1 KEEVISPIME Ø32
W
Ø110 SN8 W 1 38.00 K11 Projekteeritud kinnistusisene reoveekanalisatsioonitorustik
1. 1. PERSPEKTIIVNE VEEVÕTUKOHT
L=4.2m 1 W W
i=0.008 39.53 1. K01 Projekteeritud kinnisel meetodil rekonstrueeritav reoveekanalisatsioonitorustik
K21-2 38.98
A
1
11W
W
HT
39.72 pe Projekteeritud kinnistusisene sademeveekanalisatsioonitorustik
39.02 11W
W Ø160 SN8 K21
KO
39.15 39.02 rs 39.40
39.15 5. ab . lp WW1 L=6.8m
38.55
D11-18
00 Projekteeritud kinnistusisene drenaažitorustik
22
ih iuv 2 .1 i=0.006 D11
39.15 Ø160 SN8 oo ä
2
38.55
W
A
W
ne lja
1.
L=2.9m
L
Ø110 SN8 7. Projekteeritud sademeveekanalisatsiooni survetorustik
1
KS2
RK
L=2.7m 50 i=0.006 W
2 1
PA
1
W.1
11WW
i=0.008 1W2 V11 Projekteeritud kinnistusisene veetorustik
8
SN
2
5.
W
1W
m
W
01 39.78
00
.2
1.
KS2-2
12
/1
Olemasolev veetorustik
1
1
10
W1.1 37.98 V
L=
39.40
x3
11W
W
Ø1
LAHENDATAKSE ERALDI JÄRGMISE PROJEKTIGA
05
37.98
39.40 D1
W
.0
80
1
38.43
15
2
2 Ø Olemasolev reoveekanalisatsiooni torustik
i=0
11WW
39.75 Ø1 2 K
2.
2
SVL-4 39.18 i=0 38.43 38.49 11W
1W110 W
W
3 10 3
W
1
RK
1.
2 .0 SN 38.43 38.49 /1 1
1 0 00 .1
1
9 Olemasolev sademveekanalisatsiooni torustik
8
L= 8 SK
SN
38.49 SN
PA
11
m
8
00
.1
.4 39.40 Wi=0
12
m
/1
39.52 3
D11-19 38.36 2 .0 Olemasolev drenaažitorustik
E
10
L=
D
K11-2 38.16 39.37 1W06 L W1
1W
8
2 1
W1
Ø1
2 1
Ø1 W
SN
AT
RENN-1
05
.1
X
2m
.1 X
1
WØ W1
11W 38.36 D1 Ø =4 .
1
.0
39.02 2. 1
10
5.
K2
m
i=0
Ø110 SN8 38.16 Olemasolev sidekanalisatsioon
L=
2
1m
.9
SK
1 39.38
D1 W
S
60
1 110/1
20
2
39.69
8
X
X
3
KÄ D11-5
00
K1 SN8 i= W1 1
L=
W1
SVL-3 39.32 L=3.0m
W
1.1 38.25
0.
Ø160 SN8 39.37 112W1 W1
.1
00
6
i=
8
i=0.008 1K2 0.006 .1 Olemasolev madalpingekaabel
0
W RENN-1
8
SN
SI
.0
SN 38.30
m
SN
X
1
X
Ø110 SN8 L=33.5m W
i=0
39.00
.2
.1
K 1 1W
m
1Ø110
1
39.59 8
1 L=2
K2
PA
=9
00
38.30
.7
Ø160 SN8 i=0
8
K11-1 38.33 i=0.007
i=0.009 L=3.8m
12
L
/1
SN
.0 2
i=0.009 L=19.1m Olemasolev kõrgepingekaabel
.1009
X
10
L=
07
1.
LL
Ø160 SN8
X
L=24.2m
W
60
6m
Ø1
1W
W
W.
L=
05
W11i=0
38.44 W
1.
Ø1
i=0.007 RK 1 39.32 D1 Ø 42 1.1
.0
1. 39.32 PEØ110 PN10
1
36
X
i=0
38.33 Ø160 SN8 39.53 1 K21-4 .2
2
D1m Olemasolev kõrgepingekaabel
X
39,37
SVL-2 39.09 38.78 39.28 1 110/1
WW L= N8
38.20 L=47.8m
x
2
Ø1 W
m
1W
1
S
23 4
40
1 .8
L=6.6m
6
38.84 K11-3 1 11W
X
10
00 38.20 i=0.014
1. 10
1
WW W
Ki=01
5
3 2
39.37 1 Ø2
W 38.78 37.93 Olemasolev soojustorustik
X
39.68 i=0.007 SN
W
W T
2 1.
4
RK-1 38.90 39.37 38.20
N8
00
W
8
8
HK11-1 38.38 Ø110 SN83 1 1 1
1.
3
.01 1. 37.93
00
K21-3 38.81 X i=0
0S
SN
1
m
X 23
1
1
1
2
0.
03
i=0.004 L=
.0
.2
Ø110/100
39.25
2
8
Ø1
i=
/14
Olemasolev soojustorustik
1
Ø110 SN8 0
12
L
i=X0
i=0.065 L= 7 D11-6
KS
2T
38.85 39.45 2 =8
10
39.23
60
6.9m
L=
L= X
38.35
.01
.6 3
39.25
38.85 38.88 K21-13 K21-5
Ø11
L=4.3m 42
m
D
SN
39.53 Ø
04
39.68
1.
8
0L
1 2
38.73 .2 38.35
SVL-15 39.68 2
SVL-16i=0.009
SN
W 1 Ø
.0
00
8
1m
D1 m 38.15 Likvideeritud reoveekanalisatsioonitorustik
W
2
i=0
=4
Ø160 SN8 38.85 38.88 39.18 SN 1. 1 11 38.77
X 2 3
K
5.
10
38.54
13.8m
SN8
1W
.0m
1 0/ 38.15
L=
39.67 1 8
Ø1
L=4.6m K21-18 Ø160 SN8 38.88 39.30 i=0 10 38.73 1 1
09
SVL-5 39.23 .0 0
SN 39.13 38.15 X 2
.0
0 K21-6 38.66
8
i=0.007
W
38.88 3
i=0
SN
L=2.6m 39.53 L= 8
40 1
39.68 39.23 39.24 Ø11
m
i=0
SVL-17 SVL-5 39.21 K W
/1 1.
14 1 0/10
.1
HK11-2 38.47 i=0.007 1 .0 38.71 X D11-4 2
60W
39.69 0 SN
1
12
39.23 .4
Ø110/10
38.95
i=0.005
38.82 . 0 38.10
SVL-1 39.27 1 m 1 5 8 i=0 11W W
L=
39.57 L =4 38.66 3
.004
L=24 W 2
39.25 D11 SPORTFIX Soft - pehmendusega äärekivi (1000 x 200/400 x 60 mm)
Ø1
3
38.15 D11-7
04
HK11-3 39.53 2
2
X
39.12 Ø1 2 .3 39.15
.0
8
38.02 SVL-7 1 .6m 38.45 2
SN
38.10
KS
m
RK-6 D K11-4
9m
i=0
6 2 3 Ø W
L=5.7m
1
0 SN8
38.36 38.94 0 0 m 1 0/10 38.45
1. 11
Ø200 SN8 37.70 .
4.
Ø
10
Ø160 SN8 S W 38.43 6
1
Ø110 SN8 N8 20 L=1
1 0 SN SPORTFIX Sand - liivaogumismatt (1000 x 500 x 163 mm)
L=
X
1.
1
Ø1
2
Ø110 SN8 38.42 i=0.005
4 8 i=0
39.48 0 37.70 38.45 1
N8 W
L=8.9m i=0 1
09
L=6.4m K11-9 38.00 L=13.1m SN .004 D11 D1
8 3 W
.0
2 3
L=6.5m .0 8 N L=19 3
i=0.004 S
N8
0
i=0
L= K .0
2
8
i=0.010 i=0
X .8m
0S
i=0.009 39.40 7 0
m
0
SN
0/ 1
m
2 1 1 1
0S
2
SVL-8 33 2 03
.6
38.00 i=0.013 Ø11
6m
/14
.6
Proj renn
2
39.20
12
10
38.87 .2 K1 L=
3
/10
W
W
11W
5.
L=
60
Ø1
L=
Ø110/10
X
W
L=
39.52 m 1
10
1
3
3.2
Ø1
39.34 39.40 Ø160 SN8 2 38.57
09
2
.1
4
Ø200 SN8 SVL-10 38.92 0. 4 1
1
Ø1
8
Ø1
0
HK11-4
09
K21-14 38.77 S N 1
.0
3m /10 0
.0
K1 1 1 W
0 38.57 39.20
0
3
.0
38.09 Ø 2
i=0
L=4.5m 3
10/
i=
1
L=2.0m 1. W
8
i=0
2 3
Proj veerenn (Ikodor 400 x 400 x 70 mm)
1.
RK 2
SN
4
Ø1
7m
1 L1=13.0m Ø1 38.57 38.50 2
W
38.82
100
39.07 i=0.005
0 SN8 i=
W
i=0.008 i=0.005
5m
Ø110 SN8 1 5
10
5.
1.
10/
m
39,1239.27 RK-2 38.73RK 3 38.57
L=
38.77 3 1 38.50
.7
5.
Ø1
1
0
D11
SN
SVL-13 3 4 2
/
1
=1
1
L=3.9m
50 X
10
D11
09
8
=2
1 2
00
38.82 38.50
SN
1
39.25
Ø160 SN8 38.76
mL
39.31 39,0739.14 W 39.20 0
8 i=
2
Projekt truup (voolu suunaga)
.0
1
1 009 L
i=0.012 SN
0.94
HK11-6 36.10 SVL-6 D D11-8
i=0
SN
0.005 L=
2 1
D 38.50
=.04
D11
39.40 39.23 1. 38.49 8 38.55
0.0
3 4 Ø
38.73 1
Ø2
39.13 1
=L0
3 4 i=0
8 i=
SVL-11 16 K21-15 Ø1
DN18 i=0.
L=12.2m i
11 .008
.5 X
21 7m
=
KS2-1 1 10/
R6.00
2
m
04
W
03i
2
38.86 39.33 0 1 0 38.69 38.49 38.55
N.08
2 .0
L= 6.
SN 1
0.0
i=0.008 39.11 37.33
1.
39.29 K11-10 37.88 0 1
7X =1
Projekt nõlv
L=2
=S0
6L 8 38.75 SVL-9 00 L= W 38.55
1
1
K11-16 36.08 38.49
S
22.7m
0
00 L
Ø160 SN8
40i
=1 37.33 24 2
00
38.69 SN
4L
0. 03
4.6
/1
W
X
2.6 38.69 .5
/1
K1 37.96 8
X8 i==0.0
60
1
1 m 39.40
=19
L=2.2m
10
2
Ø160 SN8 m i
m
36.08 1 39.13 =0 .
Ø1
37.88 38
1 D11-9
Ø1
0 K 1
N 2
.0
SN 8 i
S K21-7
1
39.24 1 i=0.008 Olol hoone
.8m
K 1 1 2 05 38.57
1 .1m Ø16
SN
L=20.6m
K11
W
K11-13 36.04 1
X
2 3
K1 38.00 Ø 1 3 38.64 L=
X 16.606m
L=4i 1
K2
39.33
1.
Ø 250
i=0.007 32
8
39.30 1 HK11-5 09 =0.0 38.69 1 23
1
3 4 1 Ø110/100 SN8 i=0.005
Ø110 SN
0 .7
8
K11-12 0.0
2
4
L=22.7m
Ø
36.04 X SN m W
SN
36.39 D D11
i=Ø0.009 L=
2
39.25 i= 0 38.69 5 Ø11
4 0/100
SN8
36.28
KS
6 1. 3
m
36.18
1
X SVL-12 L 8
D 1
3 1 2 Olol hoone sissepääs
0
8
2
.8
1 X
= 1
14
SN
36.28 X 39.10 1 38.64 1
12
38.79 11 110
Ø1
1
0 2
i=0. 005
m
Ø Ø
0/
W
K21-8 38.58 L=5.7m
X
X .6
L=
39.20
00
11
.9
m 23 4
16
Ø160 SN8 39.20
10
39.20
i=0
W
2
X K2
.1m
10
0
/1
04
SVL-14 38.63
/10
2 3 /1 /1
1.
.00
10
i=0.00
L=
1
38.04 00
X
00
.0
L=12.2m 38.68 38.58 Proj staadioni rajakate (tüüp 1)
1
0S
Ø110
W
Ø1
L=16
1
i=0
39.27
4L
05
1 SN SN
1
i=0.008 Ø110 SN8 K11-11 39.30
2
K21-17 38.29 38.04 1. 38.58
N8
38.63 D
.0
X
8 8
=8
1
K0
1
m
X
i=0
i i = 39.19
9 L=7.9
3 =
L=17.6m 1
38.04 1
.5
.2m
m
36.38 38.58 0. 0. 38.58
0.006
X
SN8
2
39.45 1 RK-7
1
Di=11
00
5.6
39.20 01
1Ø126 12 3 L=2
38.53
5m
39.07 i=0.009 36.38 7 39.45 8
L= 38.58 38.66 Proj siirdemuru (tüüp 2)
8
39.09 D11-3
=3
W
X
W
L=
N
6.
K21-16 38.56 38.59
6
/14 X
38.53 K11-5
0S
3 4
4L
1.
37.99
K1KKXSIBi=Ü0.Ü00N
2
=1
m
3 38.69
2
Ø2
m
D1 Ø 2. W 4. .7m
X
x4
.8
37.50
1
38.59
1 005 L
5m
SN8
6m
.00
38.29 Ø160 SN8 1 0 1. 16
12
37.99
39.10 D
2
38.60 0 Ø1 38.69 1 L=
X
0
i=0
37.73 1
L=
SN
72
11
11
R8
L=1.4m 1 Proj külvimuru (tüüp 3)
D1 i=0.
38.42 /1 38.69 6
STN
8 0/ RENN-3 0
/100
.00
04
N8
38.60 Ø200 SN8 i=0 37.55 10
=0 1
X
38.71 00
.0
50
38.60 i=0.006
8
38.69
1 200 S
0
.0 8i 2 RK 7
SN
AK
i=0
SN
X
2 Ø
Ø2
SN
Ø110
W
04 2 3
0S K
L=39.1m D38.69
8 W 1 1 N
00
1.
39.04 RK 4i=0.005 L= 8
W
11i=0.007 39.201.1 i=0 1 0/1 39,19
K0 Ø
i=0 Proj tõuke- ja heiteringide betoonkate (tüüp 4)
1
3
/1
1
LJ
RK-3 38.61
X
13 39.45 16
2
00
10
.0 .0
39,036 .5
8X
SN Ø
X
R1 .50 m4 39.20 05 1 08
Ø1
Ä
39.10 L= 38.59 L=38.48 L= 3 48 2
SN
23 2
RENN-4 38.52 30
IV
5. 1
m
37.94 32
X
D1 Ø 38.59 38.48
.2
40
7m
8
1 .7 Proj kaugushüppekasti liiv (tüüp 5)
X
2.
m
W
m
D
/1
37.94
LL
W
N8
1
04 X
38.48
60
1 10/1
L=
1.
1 1
1
0S
m
.1
Ø1
37.94
1
1 2
1
PA
.0
X
/14
Ø1
X
10
00
X 0.0
K1 KS
39.13 10
60
L=
SN Proj kuulitõukesektori killustikkate (tüüp 6)
i=
2
K21-9 2
/1
LG
Ø1
05
8 00
N
39.23 38.51 i
X
39.45
ÜÜ
3 =
.0
39.30
X 1.1
1 SN 39.25
N8
1 2 3
K21-10 0.
W
i=0
K11-14 35.89 38.51 02
D
JA
D11-10
IB
39.20 8
m
0S
38.45 1
m
0 38.59 i=0 1
1
3.1
38.44
TR
L
.6
38.51 Proj kinnistusiseste teede asfaltbetoonkate, ka katendi taastamine (tüüp 7)
/14
Ø160 SN8 = .
38.58 2
1 08 L0
15
37.88
X
=1
35.89 3 38.59
D 2. 38.44
1
60
L=
38.51
4L
6m
X
38.45
m
1
K2
L=1.0m 37.88 D
Ø1
=3 38.44
03
Ø1
.2
Ø200 SN8
.00
39.15 1 2 L=43
.1
11 0.
.0
1
Ø160 SN8 i=0.082 1 37.88 W1 2
K11-6 37.30
X
0/
i=0
m 38.56
i=0
Projekt sõidutee ülekate eelneva freesimisega (tüüp 8)
K0
L=17.9m 2 10 Ø1
X
0
KSi=0.001
L=3.2m
8
10
6
SN
i=0.004 2 SN /
37.30
5
i=0.005
1
Ø 8 1 00 39.25
40
X
4
3 1 W 39.20 i=
39.33 Ø200 SN8 1 10 39.45 S
D11-2 0.022
/1
3
8
WW
38.38
i=0 /11.
DN18 i=0. Proj kõnniteede asfaltbetoonkate (tüüp 9)
X
HK11-7 35.81
1 0041L 50NSN
60
2
1
1.1.
. 001 37.83 38.59
Ø1
39.20 L=41.1m 0 38.38
1
11
PEØ110 PN10 05 L=
DNK18 i1=K01. 2 IBØÜ2 Ü
SN 2 3
Ø200 SN8 35.81
2
RENN-5 L 8 37.83 3 2.
2
38.59 1 5L 00
38.38
7m
L=107.0m 38.50 i=0.005 =8 6m 1
X
1
TR
1 . 38.42 D1 =
4.
L=9.9m 1 m 30 Proj kõnniteede asfaltbetoonkate (tüüp 10 )
=2
i=0.001 Ø160 SN8 2 W 39.45
N8
1 .2
i=0.010 3
1 m
0S
.1
WW
m
Ø1
m
L=13.5m 38.59
X
.8
1.1.
L=18.5
Ø1 10
/14
12
11
i=0.008 10 38.59 /1
39.17
60
L=
00 Proj kõnniteede tänavakattekivi, ka katendi taastamine (tüüp11)
R2.05
39.08 /1
K21-19
Ø1
00 S
04
HK11-9 35.71 2
Ø315 SN8
DN18 i=0.
S
2
35.60
X
SNW 39.25
.0
0.006
40
1
KS
i=0
1
39.18 35.63 D 81.
/1
D11
L=18.1m i 1 2 3
38.33
35.71 1 = 2
1 01
60
K11-17 37.49
WW
39.20 0. 2 Proj sõiduteede tänavakattekivi, ka katendi taastamine (tüüp 12)
1
N8 i=
Ø1
i=0.008 00 1
1.1.
X
5 L= 38.33
X
11
37.49 39.33 39.20 38.46 L =2 3 0. 38.33
8
2 3
D11-1 39.45 2m
/100 S
SN
Ø200 SN8 Ø160 SN8 37.72 38.46 4 .5W
1
Ø1
m
38.36 38.46 m1 Proj killustikkate (tüüp 13)
40
1
.8
38.59 1
K0X
2
. 1 0
12
37.72
/1
L=15.6m L=7.9m 3 38.36 /1
60
Ø110
L=
38.59 00
X
1 Ø16
WW
37.72 39.25
Ø1
i=0.010
1
i=0.008 39.17 0/14 38.36 SN
04
38.59 D11-11
1.11.1
0
K1
D
X
.0
i=0. SN8 8
K11-7 38.36 m 1
i=0 38.28 Proj välitreeningala kummikate (tüüp 14)
i=0
0 L=2 2.7
04 L i=0 .010 5
38.59 1
X
37.10 10/ 100 SN 8 W .0 2 3
38.98 Ø1
1 4L
D11
3 4 4 2
2 =13 38.44
00
2
1 1
OK-2 35.50 3
.1 38.59
1
39.25 .8m
3
1 37.43 1 2 1 1
5.
2 1
38.28
K2
D11-16 37.78 4 Ø1 =3
m
X
39.11 37.10 39.16 3 0.
Ø1
8
.0
36.65 39.10 2 W
14
.57
1 2 Proj multifunktsionaalse spordiväljaku kunstmurukate (tüüp 15)
SN
RK-4 0 m
22
SVL-18 39.16 /1
W
HK11-8 37.76 Ø 1
m
10/
Ø110/100 SN8 i=0.010 L=22.7m
38.30.1 00
L=
35.51 38.35 38.53 i= 11 RK-5
40
X
1
.8
1.1
SW
50
Ø1
RK 5 0S
X
12
100
5
2 3
38.51 39.20
/1
0.0 37.78
DN118.i1=0.
11 .00
35.55
60
N8
7.
L=
2 3
60/
Ø160 SN8 09
39,11
D 8 i=0
Ø1
SN
3 4
Ø160 SN8 1
38.46 Proj looduskividest kate (tüüp 16)
04
L= 2
140
15
K21 1 2
1 5L 0
X
D8 i=10.10
6
.0
X
L=2.4m . 39.20 0
SN
3
5m 1
W 38.46
i=0
L=2.0m 39.15 4
RENN-6 2 3 39.25
SN
2m
1
D11
=
0
i=0.007 i=0.006 K21-11 38.30
00
.1 38.51 24 W 38.46
0
/1
D11
6.
38.23
8 i=
W
.5 1 1
5.
X
10
07
X
.6m
1 =1
Ø160 SN8 m. Proj kindlustatud nõlv (tüüp 17)
1.1
Ø1
1 38.23
KK1210.003 L
38.48 39.20
0.0
1 2
L=1
8
1 18
SN
2
39.12 L=19.4m 38.23
05
38.34 39.20
Ki2=0.007 L=
m
38.48
5.9
K11-15 37.74 W
L=3.6m
40
.9
1
i=
23
L
38.30 X i=0.007 3 Ø
N8
1.
12
0/1
m
Projekt jalgrattaparkla Vivid (4020 x 2020 mm)
=20
38.48 38.36
8
39.25 RK 6 1 4 11W
SN
L=
1
6
SVL-19 38.34 2 0
Ø110 S
37.74 38.34 i=0 /110
Ø1
1
38.48 38.36
.5m
04
15
.01
X
X 39,16 Ø160 SN8 .0 39.25
.0
Ø3
i=0.009
12 3 05
Ø11 38.48 38.36 S
8
i=0
Ø160 SN8 1 2
L= 2 N38 1
SN
0/10
2
L=5.2m 3 0 SND 38.36 8 . 4 m 5 .6 38.18 Proj piirdeaed 3,0 m
101.00 1
X
L=11.1m
60
1 2 3 X 8 i= L = m
1 i=0.007 1 1 .006 38.18
Ø1
i=0.007
X Ø160 SN8
Ø16
0/14 7 L=
17.7
2 34
0 SN
D8 i= 0
38.18
3m
39.27 0
0.
X
Ø315 SN8 0 SN8 m 1 0 / 1 Proj piirdeaed 5,0 m
K21-21 38.01 Ø11
=2
L=4.4m D1 .005 Li=
KO
1 004 L
L=8.3m Ø160 SN8 0
38.31 i=0.003
i=0.008 1 =22.5m
RV
DN18 i=0.
L=7.5m
X
2
38.02 39.15 i=0.005 39.22 39.25 1 Proj liiklusmärgi post
KV-1 38.21
3
K21-22 D11-15 PA 3 Ø 39.25
S
2
R5.0 38.47 37.88 16 D11-12
40
1 0/1
i=0
X
0 38.13
38.45 L
/1
38.47 .0 40
60
37.88 L 05 S 38.44
Ø1
L= N8
38.47 28
X
39.27 10 38.13
38.47 .3
OK-1 35.38 x m 1 2
15
A
X
3
OL.OLEV DRENAAŽI SISEND TAMPONEERIDA
AL
36.94 W2 Proj.tud k/p kaabel
G
Ø200 SN8 39.25 39.33
IN
35.38 D11-14 37.99 D11-13
6m
X
EN
L=12.8m 38.05 Proj.tud m/p kaabel
2.
1W
RE
=2
i=0.005 38.30 38.05
1 005 L
T
LI
X
37.99 38.10 Proj.tud jätkumuhv (info viidal)
VÄ
D18 i=0.
39.33 39.30 Proj.tud demonteeritav
K21-12 38.24
T
RENN-7
SN
AS
38.60 Proj.tud MAANDUS
00
AK
38.24
/1
IV
39.23
10
LI
K21-20
Ø1
35.58
91
39.35
K11-8 37.00
3.
35.58 Proj.tud kaablitrass, kuni 4 kaablit trassis
Ø
37.62 W1.1
37.66 Proj.tud reservtoru d110
37.00 Ø200 SN8
L=19.0m Proj.tud maakilp sokliga
i=0.005
Demonteeritav
39.25
DRENAAŽIPUMPLA DVP-1 37.45 Proj.tud pollarvalgusti (RGB)
Ø1600, H=4.7m, 2-pumbaga (8 l/s, h=10m) 35.55 39.10
38.21
D11-17
Proj.tud tänavavalgusti konsooliga
OL.OLEV SISEND TAMPONEERIDA
Proj.tud prožektormast (4 valgustit traaversil)
Proj.tud prožektormast (5 valgustit traaversil)
Proj.tud prožektormast (7 valgustit traaversil)
Proj.tud prožektormast (2 valgustit traaversil)
Proj.tud tabloo 230W (wifi)
Proj.tud MAANDUS
Tähis Muudatus Teostaja Kuupäev
TÖÖ NIMETUS TELLIJA
RÄPINA ÜHISGÜMNAASIUMI STAADIONI REKONSTRUEERIMINE KLM PROJEKT OÜ
AADRESS JOONIS
KOOLI TN 5, RÄPINA, RÄPINA VALD
PÕLVA MAAKOND VÄLISVÕRKUDE ASENDIPLAAN
Smart Pipes OÜ
VASTUTAV SPETSIALIST
V.LOORENTS
Registrikood 11979398 PROJEKTEERIJA FAILI NIMI
tel +372 526 8802 20027_PP_VK_välisvõrk.dwg
[email protected] V.LOORENTS
Majaka tn 44-9, Tallinn, Harjumaa, 11412 OSA STAADIUM KUUPÄEV TÖÖ NR MÕÕTKAVA JOONISE NR JOONISTE ARV
MTR EEP001966, EPE000622 VK PP 11.09.2020 20027 1:500 VVK-1
Henri Vosokovski
Räpina Vallavalitsus Teie 15.09.2020
[email protected]
Kooli 1 Meie 15.09.2020 nr 15-2/20/42439-2
Räpina vald, 64504, Räpina, Põlva
maakond
Räpina linnas Kooli tn 5 kinnistu staadioni
rekonstrueerimise ehitusloa eelnõu
kooskõlastamine märkustega
Olete esitanud meile kooskõlastamiseks Põlva maakonna Räpina valla Räpina linna Kooli tn 5
kinnistu (katastritunnus 70501:004:0403) ehitusloa eelnõu (menetlus nr 229120).
Kinnistu asub riigitee nr 65 Võru – Räpina (edaspidi riigitee) km 43,69-43,91 kaitsevööndis.
Ehitusluba antakse välja Räpina Ühisgümnaasiumi staadioni, reoveekanalisatsiooni,
külmaveetorustiku, drenaažitorustiku ja sademevee kanalisatsiooni ehitamiseks. Ehitusloa aluseks
on järgmised projektid:
1. KLM Projekt OÜ projekt „Põlva maakond, Räpina vald, Räpina Ühisgümnaasiumi
staadioni rekonstrueerimise põhiprojekt“ (töö nr 2420);
2. OÜ Smart Pipes projekt „Räpina Ühisgümnaasiumi staadioni rekonstrueerimine.
Põhiprojekt. Veevarustus ja kanalisatsioon“ (töö nr 20027, peaprojekteerija KLM Projekt
OÜ);
3. KLM Projekt OÜ projekt „Põlva maakond, Räpina vald, Räpina ÜG staadioni
elektriseadmete põhiprojekt“ (töö nr 2420-1).
Oleme esitanud ettepanekud projekteerimistingimuste eelnõule 18.10.2019 kirjaga nr 15-
2/19/45838-2. Oleme projektiga tutvunud ning edastasime projekteerijale oma arvamuse
05.06.2020 kirjaga nr 15-2/20/24583-2. Kooskõlastamiseks esitatud projekti koosseisus puuduvad
kasutusala plaanid (vt meie projekteerimistingimuste eelnõule esitatud ettepanekud p 8). Jalgtee
ehitamiseks riigitee alusele maale on vajalik sõlmida isikliku kasutusõiguse leping. Palume
koostada kasutusala plaan ja saata see Maanteeameti teemaa osakonnale koos kasutusõiguse
lepingu sõlmimise taotlusega.
Lähtudes ehitusseadustiku § 70 lg 3 kooskõlastame ehitusloa eelnõu ja anname nõusoleku
teekaitsevööndis kehtivatest piirangutest kõrvale kaldumiseks tingimusel, et hiljemalt staadioni
kasutusloa väljastamise hetkeks on meile edastatud projekteeritud jalgtee kasutusala plaanid.
Projekti realiseerimisel tuleb arvestada järgnevate asjaoludega:
1. EhS § 70 lg 2 p 1 kohaselt ei tohi ehitus- ega muu tegevus kaitsevööndis ohustada riigiteed
Teelise 4 / 10916 Tallinn / 6119 300 / Registrikood 70001490 / www.mnt.ee /
[email protected], 620 1200 (kliendiinfo) /
[email protected]; 611 9300 (teedealased küsimused)
või selle korrakohast kasutamist.
2. Vastavalt EhS § 72 lg 2 on tee kaitsevööndi maa kinnisasja omanik kohustatud lubama
kõrvaldada nähtavust piirava istandiku, puu, põõsa või liiklusele ohtliku rajatise, mistõttu
ehitiste ehitamisel peavad olema tagatud majandus- ja taristuministri 5.08.2015 määruse
nr 106 „Tee projekteerimise normid“ lisas „Maanteede projekteerimisnormid“ toodud
nõuded külgnähtavuse ja ristumiskoha nähtavuskolmnurga kohta.
3. Materjalide veod korraldada olemasolevate tänavate (Kooli ja Aia tn) kaudu.
4. Projekti realiseerimisel tuleb vältida pinnase (muda, kruus jms) kandumist riigiteele.
Vajadusel näha ette vastavaid leevendavaid meetmeid, näiteks sõidukite puhastamine enne
riigiteele sõitmist.
5. Me ei võta kohustusi projektiga seotud rajatiste väljaehitamiseks.
Kooskõlastus kehtib kaks aastat kirja välja andmise kuupäevast. Kui ehitusluba ei ole selleks ajaks
välja antud, siis palume meid kaasata uuesti ehitusloa või projekteerimistingimuste menetlusse.
Lugupidamisega
(allkirjastatud digitaalselt)
Marek Lind
juhtivspetsialist
taristu teenuste osakond
Lisad:
1. 2420_PP_TL-3-01_seletuskiri
2. 2420_PP_TL-4-02_asendiplaan
3. 2420_PP_TL-4-03_liikluskorraldus
4. 24201_PP_EL-3-01_seletuskiri
5. 24201_PP_EL-4-02_asendiplaan
6. 20027_PP_VK-3-01_seletuskiri
7. 20027_PP_VK-4-01_VVK-1-valisvork
Tuuli Tsahkna
58073001
[email protected]
2 (2)