Date 28.07.2020
10084 Bussipeatuse valgusarvutus
10084 Bussipeatuse valgusarvutus
Cover page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1. . .
Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3. . . . .
Product data sheets
Philips - BGP760 T25 1 xLED18-4S/830 DPR1 (1x LED18-4S/830) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4. . . . . . . . . . . . .
Site 1
Luminaire layout plan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Calculation objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7. . . . . . . . . .
Calculation surface 1 / Perpendicular illuminance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
10084 Bussipeatuse valgusarvutus
Luminaire list
Φtotal Ptotal Luminous efficacy
1645 lm 15.0 W 109.7 lm/W
pcs. Manufacturer Article No. Article name P Φ Luminous efficacy
1 PHILIPS BGP760 T25 1 xLED18-4S/830 DPR1 15.0 W 1645 lm 109.7 lm/W
3
10084 Bussipeatuse valgusarvutus
Product data sheet
PHILIPS BGP760 T25 1 xLED18-4S/830 DPR1
Article No.
P 15.0 W
ΦLamp 1800 lm
ΦLuminaire 1645 lm
η 91.42 %
Luminous efficacy 109.7 lm/W
Polar LDC
CCT 3000 K
CRI 100
Get your city ready for the future with DigiStreet Developed with the
aim to become your long term partner ,
the system ready architecture of DigiStreet enables you to enjoy the
benefits of connected lighting systems today and also gets the city
ready for the innovations to come!. Its two sockets enable you to
connect directly to the Philips CityTouch system and is also prepared
to connect you to the future innovations of IoT.
Next to this, each individual luminaire is uniquely identifiable, thanks
to the Philips Service tag application. With a simple scan of a QR
code, placed on the inside of the mast door, you gain instant access
to the luminaire configuration, making maintenance and
programming operations faster and easier, no matter what stage of
the luminaire’s lifetime. Digistreet is also equipped with dedicated
light recipes that: 1) maintain an optimal ecosystems for bats or 2)
preserve a dark night sky.
4
10084 Bussipeatuse valgusarvutus
Site 1
Luminaire layout plan
5
10084 Bussipeatuse valgusarvutus
Site 1
Luminaire layout plan
Manufacturer PHILIPS
Article No.
Article name BGP760 T25 1
xLED18-4S/830 DPR1
Individual luminaires
X Y Mounting Luminaire
height
7.300 m 28.600 m 7.000 m 1
6
10084 Bussipeatuse valgusarvutus
Site 1
Calculation objects
7
10084 Bussipeatuse valgusarvutus
Site 1
Calculation objects
Calculation surfaces
Properties Ē Emin Emax g1 g2 Index
Calculation surface 1 2.63 lx 0.037 lx 11.2 lx 0.014 0.003 S1
Perpendicular illuminance
Height: 0.000 m
Utilisation profile: DIALux presetting, Standard (outdoor transportation area)
8
10084 Bussipeatuse valgusarvutus
Site 1
Calculation surface 1
Properties Ē Emin Emax g1 g2 Index
Calculation surface 1 2.63 lx 0.037 lx 11.2 lx 0.014 0.003 S1
Perpendicular illuminance
Height: 0.000 m
Utilisation profile: DIALux presetting, Standard (outdoor transportation area)
9
Date 01.07.2020
Päri tee ja Kannikmäe tee L1 tänavavalgustuse
rekonstrueerimine, Päri küla, Viljandi vald
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Cover page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1. . .
Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Luminaire list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3. . . . .
Product data sheets
Philips - BGP761 T25 1 xLED54-4S/830 DM10 (1x LED54-4S/830) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4. . . . . . . . . . . . . .
Summary (according to EN 13201:2015) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5. . . . .
Kannikmäe tee (M6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8. . . . . . . . . . .
Summary (according to EN 13201:2015) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 ......
Kannikmäe tee (M6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Summary (according to EN 13201:2015) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 ......
Kannikmäe tee (M6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Luminaire list
Φtotal Ptotal Luminous efficacy
58044 lm 492.0 W 118.0 lm/W
pcs. Manufacturer Article No. Article name P Φ Luminous efficacy
12 PHILIPS BGP761 T25 1 xLED54-4S/830 DM10 41.0 W 4837 lm 118.0 lm/W
3
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Product data sheet
PHILIPS BGP761 T25 1 xLED54-4S/830 DM10
Article No.
P 41.0 W
ΦLamp 5400 lm
ΦLuminaire 4837 lm
η 89.57 %
Luminous efficacy 118.0 lm/W
Polar LDC
CCT 3000 K
CRI 100
Get your city ready for the future with DigiStreet Developed with the
aim to become your long term partner ,
the system ready architecture of DigiStreet enables you to enjoy the
benefits of connected lighting systems today and also gets the city
ready for the innovations to come!. Its two sockets enable you to
connect directly to the Philips CityTouch system and is also prepared
to connect you to the future innovations of IoT.
Next to this, each individual luminaire is uniquely identifiable, thanks
to the Philips Service tag application. With a simple scan of a QR
code, placed on the inside of the mast door, you gain instant access
to the luminaire configuration, making maintenance and
programming operations faster and easier, no matter what stage of
the luminaire’s lifetime. Digistreet is also equipped with dedicated
light recipes that: 1) maintain an optimal ecosystems for bats or 2)
preserve a dark night sky.
4
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/tanuma tee, (1,2m), 41W · Alternative 19
Summary (according to EN 13201:2015)
5
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/tanuma tee, (1,2m), 41W · Alternative 19
Summary (according to EN 13201:2015)
Manufacturer PHILIPS P 41.0 W
Article No. ΦLamp 5400 lm
Article name BGP761 T25 1 ΦLuminaire 4837 lm
xLED54-4S/830 DM10
η 89.57 %
Fitting 1x LED54-4S/830
BGP761 T25 1 xLED54-4S/830 DM10 (single side bottom)
Pole distance 45.000 m
(1) Light spot height 7.000 m
(2) Light point overhang -0.600 m
(3) Boom inclination 0.0°
(4) Boom length 0.600 m
Annual operating hours 4000 h: 100.0 %, 41.0 W
Consumption 902.0 W/km
ULR / ULOR 0.00 / 0.00
Max. luminous intensities ≥ 70°: 586 cd/klm
Any direction forming the specified angle from ≥ 80°: 99.5 cd/klm
the downward vertical, with the luminaire installed ≥ 90°: 0.00 cd/klm
for use.
Luminous intensity class G*3
The luminous intensity values in [cd/klm] for
calculation of the luminous intensity class refer to
the luminaire luminous flux according to EN
13201:2015.
Glare index class D.6
6
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/tanuma tee, (1,2m), 41W · Alternative 19
Summary (according to EN 13201:2015)
Results for valuation fields
Symbol Calculated Target Check
Kannikmäe tee (M6) Lav 0.41 cd/m² ≥ 0.30 cd/m²
Uo 0.43 ≥ 0.35
Ul 0.42 ≥ 0.40
TI 15 % ≤ 20 %
REI 0.73 ≥ 0.30
A maintenance factor of 0.80 was used for calculating for the installation.
Results for energy efficiency indicators
Symbol Calculated Consumption
Kannikmäe/tanuma tee, Dp 0.026 W/lx*m² -
(1,2m), 41W
BGP761 T25 1 De 0.7 kWh/m² yr 164.0 kWh/yr
xLED54-4S/830 DM10
(single side bottom)
7
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/tanuma tee, (1,2m), 41W · Alternative 19
Kannikmäe tee (M6)
Results for valuation field
Symbol Calculated Target Check
Kannikmäe tee (M6) Lav 0.41 cd/m² ≥ 0.30 cd/m²
Uo 0.43 ≥ 0.35
Ul 0.42 ≥ 0.40
TI 15 % ≤ 20 %
REI 0.73 ≥ 0.30
Results for observer
Symbol Calculated Target Check
Observer 1 Lav 0.41 cd/m² ≥ 0.30 cd/m²
Position:
-60.000 m, 1.350 m, 1.500 m Uo 0.43 ≥ 0.35
Ul 0.42 ≥ 0.40
TI 15 % ≤ 20 %
Observer 2 Lav 0.45 cd/m² ≥ 0.30 cd/m²
Position:
-60.000 m, 4.050 m, 1.500 m Uo 0.44 ≥ 0.35
Ul 0.52 ≥ 0.40
TI 12 % ≤ 20 %
Maintenance value, horizontal illuminance [lx] (Iso-illuminance curves)
8
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Maintenance value, horizontal illuminance [lx] (Value grid)
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500 31.500 34.500 37.500 40.500 43.500
4.950 11.66 9.12 6.60 4.61 3.38 2.45 1.92 1.74 1.92 2.45 3.38 4.61 6.60 9.12 11.66
4.050 13.79 10.35 7.15 4.79 3.39 2.38 1.83 1.64 1.83 2.38 3.39 4.79 7.15 10.35 13.79
3.150 15.99 11.55 7.60 4.86 3.28 2.28 1.75 1.55 1.75 2.28 3.28 4.86 7.60 11.55 15.99
2.250 17.98 12.59 7.88 4.79 3.13 2.15 1.67 1.53 1.67 2.15 3.13 4.79 7.88 12.59 17.98
1.350 19.13 13.18 7.88 4.61 2.93 2.01 1.60 1.50 1.60 2.01 2.93 4.61 7.88 13.18 19.13
0.450 19.16 13.06 7.58 4.33 2.70 1.87 1.53 1.43 1.53 1.87 2.70 4.33 7.58 13.06 19.16
Maintenance value, horizontal illuminance [lx] (Value chart)
Eav Emin Emax g1 g2
Maintenance value, horizontal illuminance 6.38 lx 1.43 lx 19.2 lx 0.224 0.075
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Iso-illuminance curves)
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Value grid)
9
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500 31.500 34.500 37.500 40.500 43.500
4.950 0.35 0.27 0.23 0.20 0.19 0.18 0.18 0.19 0.23 0.28 0.33 0.34 0.34 0.33 0.36
4.050 0.41 0.31 0.25 0.21 0.20 0.20 0.20 0.22 0.25 0.32 0.37 0.41 0.42 0.41 0.43
3.150 0.46 0.34 0.27 0.24 0.23 0.23 0.24 0.25 0.31 0.38 0.44 0.50 0.50 0.51 0.51
2.250 0.51 0.36 0.29 0.26 0.27 0.29 0.32 0.35 0.40 0.46 0.55 0.61 0.60 0.63 0.58
1.350 0.55 0.40 0.31 0.30 0.33 0.37 0.41 0.46 0.53 0.61 0.67 0.72 0.70 0.72 0.63
0.450 0.55 0.41 0.33 0.34 0.40 0.47 0.55 0.63 0.70 0.74 0.80 0.83 0.82 0.76 0.66
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 1: Maintenance value, luminance with dry 0.41 cd/m² 0.18 cd/m² 0.83 cd/m² 0.433 0.217
roadway
Observer 1: Luminance with new installation [cd/m²] (Iso-illuminance curves)
Observer 1: Luminance with new installation [cd/m²] (Value grid)
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500 31.500 34.500 37.500 40.500 43.500
4.950 0.43 0.34 0.29 0.25 0.24 0.22 0.22 0.24 0.28 0.35 0.41 0.42 0.43 0.42 0.45
4.050 0.51 0.39 0.31 0.27 0.25 0.25 0.26 0.27 0.31 0.40 0.46 0.51 0.52 0.51 0.54
3.150 0.58 0.43 0.34 0.30 0.29 0.29 0.30 0.32 0.39 0.47 0.55 0.62 0.63 0.63 0.64
2.250 0.64 0.45 0.36 0.33 0.34 0.36 0.40 0.44 0.50 0.57 0.68 0.76 0.76 0.79 0.73
1.350 0.68 0.50 0.39 0.38 0.42 0.46 0.51 0.58 0.67 0.76 0.84 0.90 0.88 0.89 0.79
0.450 0.69 0.51 0.41 0.42 0.50 0.59 0.68 0.79 0.87 0.92 1.00 1.03 1.02 0.95 0.83
Observer 1: Luminance with new installation [cd/m²] (Value chart)
10
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Lav Lmin Lmax g1 g2
Observer 1: Luminance with new installation 0.52 cd/m² 0.22 cd/m² 1.03 cd/m² 0.433 0.217
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Iso-illuminance curves)
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Value grid)
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500 31.500 34.500 37.500 40.500 43.500
4.950 0.35 0.27 0.24 0.21 0.20 0.20 0.21 0.21 0.25 0.30 0.35 0.36 0.36 0.34 0.36
4.050 0.41 0.32 0.26 0.24 0.23 0.23 0.23 0.25 0.29 0.35 0.41 0.44 0.43 0.41 0.44
3.150 0.47 0.36 0.29 0.27 0.27 0.29 0.31 0.32 0.35 0.43 0.49 0.54 0.53 0.52 0.52
2.250 0.52 0.39 0.33 0.32 0.34 0.36 0.38 0.43 0.49 0.55 0.60 0.65 0.63 0.65 0.59
1.350 0.56 0.42 0.35 0.36 0.42 0.49 0.54 0.60 0.64 0.70 0.76 0.77 0.75 0.73 0.64
0.450 0.54 0.40 0.32 0.33 0.40 0.50 0.59 0.69 0.75 0.79 0.85 0.86 0.84 0.77 0.67
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 2: Maintenance value, luminance with dry 0.45 cd/m² 0.20 cd/m² 0.86 cd/m² 0.440 0.230
roadway
11
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Observer 2: Luminance with new installation [cd/m²] (Iso-illuminance curves)
Observer 2: Luminance with new installation [cd/m²] (Value grid)
m 1.500 4.500 7.500 10.500 13.500 16.500 19.500 22.500 25.500 28.500 31.500 34.500 37.500 40.500 43.500
4.950 0.44 0.34 0.30 0.26 0.25 0.25 0.26 0.26 0.31 0.38 0.44 0.45 0.45 0.43 0.46
4.050 0.51 0.40 0.33 0.30 0.29 0.29 0.29 0.31 0.37 0.44 0.51 0.55 0.54 0.52 0.55
3.150 0.58 0.44 0.36 0.34 0.34 0.36 0.38 0.40 0.44 0.54 0.61 0.67 0.66 0.65 0.65
2.250 0.65 0.48 0.41 0.40 0.43 0.45 0.48 0.54 0.61 0.68 0.76 0.82 0.79 0.82 0.74
1.350 0.70 0.52 0.44 0.45 0.52 0.62 0.68 0.74 0.80 0.88 0.95 0.97 0.93 0.91 0.80
0.450 0.68 0.50 0.40 0.42 0.50 0.62 0.74 0.86 0.94 0.99 1.07 1.07 1.05 0.96 0.83
Observer 2: Luminance with new installation [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 2: Luminance with new installation 0.56 cd/m² 0.25 cd/m² 1.07 cd/m² 0.440 0.230
12
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/Tanuma tee, (1,8m), 41W · Alternative 25
Summary (according to EN 13201:2015)
13
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/Tanuma tee, (1,8m), 41W · Alternative 25
Summary (according to EN 13201:2015)
Manufacturer PHILIPS P 41.0 W
Article No. ΦLamp 5400 lm
Article name BGP761 T25 1 ΦLuminaire 4837 lm
xLED54-4S/830 DM10
η 89.57 %
Fitting 1x LED54-4S/830
BGP761 T25 1 xLED54-4S/830 DM10 (single side bottom)
Pole distance 47.000 m
(1) Light spot height 7.000 m
(2) Light point overhang -1.800 m
(3) Boom inclination 0.0°
(4) Boom length 0.600 m
Annual operating hours 4000 h: 100.0 %, 41.0 W
Consumption 861.0 W/km
ULR / ULOR 0.00 / 0.00
Max. luminous intensities ≥ 70°: 586 cd/klm
Any direction forming the specified angle from ≥ 80°: 99.5 cd/klm
the downward vertical, with the luminaire installed ≥ 90°: 0.00 cd/klm
for use.
Luminous intensity class G*3
The luminous intensity values in [cd/klm] for
calculation of the luminous intensity class refer to
the luminaire luminous flux according to EN
13201:2015.
Glare index class D.6
14
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/Tanuma tee, (1,8m), 41W · Alternative 25
Summary (according to EN 13201:2015)
Results for valuation fields
Symbol Calculated Target Check
Kannikmäe tee (M6) Lav 0.33 cd/m² ≥ 0.30 cd/m²
Uo 0.44 ≥ 0.35
Ul 0.40 ≥ 0.40
TI 17 % ≤ 20 %
REI 0.65 ≥ 0.30
A maintenance factor of 0.80 was used for calculating for the installation.
Results for energy efficiency indicators
Symbol Calculated Consumption
Kannikmäe/Tanuma tee, Dp 0.028 W/lx*m² -
(1,8m), 41W
BGP761 T25 1 De 0.6 kWh/m² yr 164.0 kWh/yr
xLED54-4S/830 DM10
(single side bottom)
15
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/Tanuma tee, (1,8m), 41W · Alternative 25
Kannikmäe tee (M6)
Results for valuation field
Symbol Calculated Target Check
Kannikmäe tee (M6) Lav 0.33 cd/m² ≥ 0.30 cd/m²
Uo 0.44 ≥ 0.35
Ul 0.40 ≥ 0.40
TI 17 % ≤ 20 %
REI 0.65 ≥ 0.30
Results for observer
Symbol Calculated Target Check
Observer 1 Lav 0.33 cd/m² ≥ 0.30 cd/m²
Position:
-60.000 m, 1.350 m, 1.500 m Uo 0.45 ≥ 0.35
Ul 0.40 ≥ 0.40
TI 17 % ≤ 20 %
Observer 2 Lav 0.36 cd/m² ≥ 0.30 cd/m²
Position:
-60.000 m, 4.050 m, 1.500 m Uo 0.44 ≥ 0.35
Ul 0.52 ≥ 0.40
TI 12 % ≤ 20 %
Maintenance value, horizontal illuminance [lx] (Iso-illuminance curves)
16
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Maintenance value, horizontal illuminance [lx] (Value grid)
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 9.13 7.60 5.81 4.27 3.24 2.43 1.91 1.68 1.68 1.91 2.43 3.24 4.27 5.81 7.60 9.13
4.050 11.00 8.80 6.49 4.60 3.39 2.45 1.85 1.59 1.59 1.85 2.45 3.39 4.60 6.49 8.80 11.00
3.150 13.08 10.03 7.09 4.83 3.45 2.39 1.78 1.50 1.50 1.78 2.39 3.45 4.83 7.09 10.03 13.08
2.250 15.28 11.27 7.62 4.95 3.37 2.31 1.71 1.42 1.42 1.71 2.31 3.37 4.95 7.62 11.27 15.28
1.350 17.43 12.42 8.00 4.94 3.23 2.19 1.63 1.39 1.39 1.63 2.19 3.23 4.94 8.00 12.42 17.43
0.450 18.89 13.23 8.12 4.80 3.05 2.05 1.55 1.36 1.36 1.55 2.05 3.05 4.80 8.12 13.23 18.89
Maintenance value, horizontal illuminance [lx] (Value chart)
Eav Emin Emax g1 g2
Maintenance value, horizontal illuminance 5.68 lx 1.36 lx 18.9 lx 0.239 0.072
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Iso-illuminance curves)
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Value grid)
17
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 0.26 0.23 0.21 0.17 0.17 0.15 0.15 0.16 0.17 0.20 0.25 0.28 0.27 0.26 0.27 0.27
4.050 0.32 0.26 0.23 0.19 0.18 0.16 0.16 0.17 0.19 0.23 0.28 0.32 0.32 0.32 0.32 0.34
3.150 0.39 0.30 0.24 0.21 0.19 0.18 0.18 0.20 0.21 0.26 0.32 0.36 0.39 0.40 0.39 0.41
2.250 0.44 0.33 0.26 0.23 0.21 0.21 0.22 0.23 0.25 0.31 0.38 0.44 0.48 0.48 0.47 0.49
1.350 0.50 0.36 0.28 0.24 0.24 0.26 0.28 0.31 0.35 0.39 0.46 0.54 0.59 0.58 0.60 0.56
0.450 0.54 0.39 0.29 0.27 0.29 0.34 0.37 0.41 0.46 0.53 0.60 0.66 0.70 0.68 0.70 0.62
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 1: Maintenance value, luminance with dry 0.33 cd/m² 0.15 cd/m² 0.70 cd/m² 0.451 0.215
roadway
Observer 1: Luminance with new installation [cd/m²] (Iso-illuminance curves)
Observer 1: Luminance with new installation [cd/m²] (Value grid)
18
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 0.33 0.29 0.26 0.22 0.21 0.19 0.19 0.20 0.21 0.25 0.31 0.35 0.34 0.33 0.33 0.34
4.050 0.41 0.33 0.28 0.24 0.22 0.21 0.21 0.21 0.23 0.28 0.36 0.40 0.40 0.40 0.40 0.42
3.150 0.48 0.37 0.30 0.26 0.23 0.22 0.23 0.25 0.27 0.32 0.41 0.46 0.49 0.50 0.48 0.51
2.250 0.55 0.42 0.32 0.28 0.27 0.27 0.28 0.28 0.32 0.39 0.47 0.55 0.60 0.60 0.59 0.61
1.350 0.62 0.45 0.34 0.30 0.30 0.32 0.35 0.39 0.43 0.49 0.58 0.67 0.73 0.73 0.74 0.71
0.450 0.67 0.48 0.37 0.34 0.36 0.42 0.47 0.52 0.58 0.67 0.75 0.82 0.87 0.85 0.87 0.77
Observer 1: Luminance with new installation [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 1: Luminance with new installation 0.42 cd/m² 0.19 cd/m² 0.87 cd/m² 0.451 0.215
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Iso-illuminance curves)
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Value grid)
19
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 0.26 0.24 0.21 0.18 0.17 0.16 0.16 0.17 0.19 0.22 0.27 0.29 0.28 0.27 0.27 0.27
4.050 0.33 0.26 0.23 0.20 0.18 0.18 0.18 0.20 0.21 0.25 0.30 0.34 0.34 0.34 0.33 0.34
3.150 0.39 0.30 0.25 0.22 0.22 0.21 0.21 0.22 0.25 0.29 0.36 0.39 0.41 0.41 0.39 0.41
2.250 0.45 0.34 0.27 0.24 0.24 0.26 0.28 0.29 0.31 0.36 0.43 0.48 0.51 0.50 0.49 0.49
1.350 0.51 0.38 0.30 0.28 0.30 0.34 0.35 0.38 0.43 0.49 0.53 0.60 0.63 0.61 0.61 0.57
0.450 0.55 0.40 0.32 0.31 0.35 0.43 0.50 0.54 0.58 0.63 0.70 0.74 0.75 0.71 0.71 0.63
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 2: Maintenance value, luminance with dry 0.36 cd/m² 0.16 cd/m² 0.75 cd/m² 0.442 0.215
roadway
Observer 2: Luminance with new installation [cd/m²] (Iso-illuminance curves)
Observer 2: Luminance with new installation [cd/m²] (Value grid)
20
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 0.33 0.29 0.26 0.22 0.21 0.20 0.20 0.22 0.24 0.27 0.33 0.36 0.35 0.34 0.34 0.34
4.050 0.41 0.33 0.29 0.25 0.23 0.22 0.23 0.25 0.26 0.31 0.38 0.42 0.42 0.42 0.41 0.43
3.150 0.48 0.38 0.31 0.28 0.27 0.26 0.27 0.28 0.31 0.37 0.44 0.48 0.52 0.52 0.49 0.52
2.250 0.56 0.43 0.34 0.31 0.30 0.32 0.34 0.37 0.39 0.45 0.54 0.60 0.64 0.63 0.61 0.62
1.350 0.63 0.47 0.37 0.35 0.37 0.42 0.44 0.48 0.53 0.61 0.67 0.74 0.78 0.76 0.77 0.71
0.450 0.68 0.50 0.40 0.39 0.44 0.53 0.63 0.68 0.73 0.79 0.87 0.93 0.93 0.88 0.89 0.78
Observer 2: Luminance with new installation [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 2: Luminance with new installation 0.45 cd/m² 0.20 cd/m² 0.93 cd/m² 0.442 0.215
21
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/Tanuma tee, (2,3m), 41W · Alternative 26
Summary (according to EN 13201:2015)
22
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/Tanuma tee, (2,3m), 41W · Alternative 26
Summary (according to EN 13201:2015)
Manufacturer PHILIPS P 41.0 W
Article No. ΦLamp 5400 lm
Article name BGP761 T25 1 ΦLuminaire 4837 lm
xLED54-4S/830 DM10
η 89.57 %
Fitting 1x LED54-4S/830
BGP761 T25 1 xLED54-4S/830 DM10 (single side bottom)
Pole distance 47.000 m
(1) Light spot height 7.000 m
(2) Light point overhang -1.800 m
(3) Boom inclination 0.0°
(4) Boom length 0.600 m
Annual operating hours 4000 h: 100.0 %, 41.0 W
Consumption 861.0 W/km
ULR / ULOR 0.00 / 0.00
Max. luminous intensities ≥ 70°: 586 cd/klm
Any direction forming the specified angle from ≥ 80°: 99.5 cd/klm
the downward vertical, with the luminaire installed ≥ 90°: 0.00 cd/klm
for use.
Luminous intensity class G*3
The luminous intensity values in [cd/klm] for
calculation of the luminous intensity class refer to
the luminaire luminous flux according to EN
13201:2015.
Glare index class D.6
23
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/Tanuma tee, (2,3m), 41W · Alternative 26
Summary (according to EN 13201:2015)
Results for valuation fields
Symbol Calculated Target Check
Kannikmäe tee (M6) Lav 0.33 cd/m² ≥ 0.30 cd/m²
Uo 0.44 ≥ 0.35
Ul 0.40 ≥ 0.40
TI 17 % ≤ 20 %
REI 0.65 ≥ 0.30
A maintenance factor of 0.80 was used for calculating for the installation.
Results for energy efficiency indicators
Symbol Calculated Consumption
Kannikmäe/Tanuma tee, Dp 0.028 W/lx*m² -
(2,3m), 41W
BGP761 T25 1 De 0.6 kWh/m² yr 164.0 kWh/yr
xLED54-4S/830 DM10
(single side bottom)
24
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Kannikmäe/Tanuma tee, (2,3m), 41W · Alternative 26
Kannikmäe tee (M6)
Results for valuation field
Symbol Calculated Target Check
Kannikmäe tee (M6) Lav 0.33 cd/m² ≥ 0.30 cd/m²
Uo 0.44 ≥ 0.35
Ul 0.40 ≥ 0.40
TI 17 % ≤ 20 %
REI 0.65 ≥ 0.30
Results for observer
Symbol Calculated Target Check
Observer 1 Lav 0.33 cd/m² ≥ 0.30 cd/m²
Position:
-60.000 m, 1.350 m, 1.500 m Uo 0.45 ≥ 0.35
Ul 0.40 ≥ 0.40
TI 17 % ≤ 20 %
Observer 2 Lav 0.36 cd/m² ≥ 0.30 cd/m²
Position:
-60.000 m, 4.050 m, 1.500 m Uo 0.44 ≥ 0.35
Ul 0.52 ≥ 0.40
TI 12 % ≤ 20 %
Maintenance value, horizontal illuminance [lx] (Iso-illuminance curves)
25
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Maintenance value, horizontal illuminance [lx] (Value grid)
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 9.13 7.60 5.81 4.27 3.24 2.43 1.91 1.68 1.68 1.91 2.43 3.24 4.27 5.81 7.60 9.13
4.050 11.00 8.80 6.49 4.60 3.39 2.45 1.85 1.59 1.59 1.85 2.45 3.39 4.60 6.49 8.80 11.00
3.150 13.08 10.03 7.09 4.83 3.45 2.39 1.78 1.50 1.50 1.78 2.39 3.45 4.83 7.09 10.03 13.08
2.250 15.28 11.27 7.62 4.95 3.37 2.31 1.71 1.42 1.42 1.71 2.31 3.37 4.95 7.62 11.27 15.28
1.350 17.43 12.42 8.00 4.94 3.23 2.19 1.63 1.39 1.39 1.63 2.19 3.23 4.94 8.00 12.42 17.43
0.450 18.89 13.23 8.12 4.80 3.05 2.05 1.55 1.36 1.36 1.55 2.05 3.05 4.80 8.12 13.23 18.89
Maintenance value, horizontal illuminance [lx] (Value chart)
Eav Emin Emax g1 g2
Maintenance value, horizontal illuminance 5.68 lx 1.36 lx 18.9 lx 0.239 0.072
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Iso-illuminance curves)
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Value grid)
26
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 0.26 0.23 0.21 0.17 0.17 0.15 0.15 0.16 0.17 0.20 0.25 0.28 0.27 0.26 0.27 0.27
4.050 0.32 0.26 0.23 0.19 0.18 0.16 0.16 0.17 0.19 0.23 0.28 0.32 0.32 0.32 0.32 0.34
3.150 0.39 0.30 0.24 0.21 0.19 0.18 0.18 0.20 0.21 0.26 0.32 0.36 0.39 0.40 0.39 0.41
2.250 0.44 0.33 0.26 0.23 0.21 0.21 0.22 0.23 0.25 0.31 0.38 0.44 0.48 0.48 0.47 0.49
1.350 0.50 0.36 0.28 0.24 0.24 0.26 0.28 0.31 0.35 0.39 0.46 0.54 0.59 0.58 0.60 0.56
0.450 0.54 0.39 0.29 0.27 0.29 0.34 0.37 0.41 0.46 0.53 0.60 0.66 0.70 0.68 0.70 0.62
Observer 1: Maintenance value, luminance with dry roadway [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 1: Maintenance value, luminance with dry 0.33 cd/m² 0.15 cd/m² 0.70 cd/m² 0.451 0.215
roadway
Observer 1: Luminance with new installation [cd/m²] (Iso-illuminance curves)
Observer 1: Luminance with new installation [cd/m²] (Value grid)
27
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 0.33 0.29 0.26 0.22 0.21 0.19 0.19 0.20 0.21 0.25 0.31 0.35 0.34 0.33 0.33 0.34
4.050 0.41 0.33 0.28 0.24 0.22 0.21 0.21 0.21 0.23 0.28 0.36 0.40 0.40 0.40 0.40 0.42
3.150 0.48 0.37 0.30 0.26 0.23 0.22 0.23 0.25 0.27 0.32 0.41 0.46 0.49 0.50 0.48 0.51
2.250 0.55 0.42 0.32 0.28 0.27 0.27 0.28 0.28 0.32 0.39 0.47 0.55 0.60 0.60 0.59 0.61
1.350 0.62 0.45 0.34 0.30 0.30 0.32 0.35 0.39 0.43 0.49 0.58 0.67 0.73 0.73 0.74 0.71
0.450 0.67 0.48 0.37 0.34 0.36 0.42 0.47 0.52 0.58 0.67 0.75 0.82 0.87 0.85 0.87 0.77
Observer 1: Luminance with new installation [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 1: Luminance with new installation 0.42 cd/m² 0.19 cd/m² 0.87 cd/m² 0.451 0.215
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Iso-illuminance curves)
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Value grid)
28
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 0.26 0.24 0.21 0.18 0.17 0.16 0.16 0.17 0.19 0.22 0.27 0.29 0.28 0.27 0.27 0.27
4.050 0.33 0.26 0.23 0.20 0.18 0.18 0.18 0.20 0.21 0.25 0.30 0.34 0.34 0.34 0.33 0.34
3.150 0.39 0.30 0.25 0.22 0.22 0.21 0.21 0.22 0.25 0.29 0.36 0.39 0.41 0.41 0.39 0.41
2.250 0.45 0.34 0.27 0.24 0.24 0.26 0.28 0.29 0.31 0.36 0.43 0.48 0.51 0.50 0.49 0.49
1.350 0.51 0.38 0.30 0.28 0.30 0.34 0.35 0.38 0.43 0.49 0.53 0.60 0.63 0.61 0.61 0.57
0.450 0.55 0.40 0.32 0.31 0.35 0.43 0.50 0.54 0.58 0.63 0.70 0.74 0.75 0.71 0.71 0.63
Observer 2: Maintenance value, luminance with dry roadway [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 2: Maintenance value, luminance with dry 0.36 cd/m² 0.16 cd/m² 0.75 cd/m² 0.442 0.215
roadway
Observer 2: Luminance with new installation [cd/m²] (Iso-illuminance curves)
Observer 2: Luminance with new installation [cd/m²] (Value grid)
29
Päri tee ja Kannikmäe tee L1 tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
m 1.469 4.406 7.344 10.281 13.219 16.156 19.094 22.031 24.969 27.906 30.844 33.781 36.719 39.656 42.594 45.531
4.950 0.33 0.29 0.26 0.22 0.21 0.20 0.20 0.22 0.24 0.27 0.33 0.36 0.35 0.34 0.34 0.34
4.050 0.41 0.33 0.29 0.25 0.23 0.22 0.23 0.25 0.26 0.31 0.38 0.42 0.42 0.42 0.41 0.43
3.150 0.48 0.38 0.31 0.28 0.27 0.26 0.27 0.28 0.31 0.37 0.44 0.48 0.52 0.52 0.49 0.52
2.250 0.56 0.43 0.34 0.31 0.30 0.32 0.34 0.37 0.39 0.45 0.54 0.60 0.64 0.63 0.61 0.62
1.350 0.63 0.47 0.37 0.35 0.37 0.42 0.44 0.48 0.53 0.61 0.67 0.74 0.78 0.76 0.77 0.71
0.450 0.68 0.50 0.40 0.39 0.44 0.53 0.63 0.68 0.73 0.79 0.87 0.93 0.93 0.88 0.89 0.78
Observer 2: Luminance with new installation [cd/m²] (Value chart)
Lav Lmin Lmax g1 g2
Observer 2: Luminance with new installation 0.45 cd/m² 0.20 cd/m² 0.93 cd/m² 0.442 0.215
30
TELLIJA: Viljandi Vallavalitsus TÖÖPROJEKT
Kauba tn 9, Viljandi linn
Tel. 4350112
Päri tänavavalgustuse rekonstrueerimine
Päri küla, Viljandi vald
Viljandimaa
Projekteerija Ivo Maaten
[email protected]
Nr 10084
Tallinn
13.08.2020
LEONHARD WEISS OÜ Vesse 8 Tel +372 6012285
[email protected]
Registrikood 12083348 11415 TALLINN www.leonhard-weiss.ee
Tööprojekt Päri tänavavalgustuse rekonstrueerimine,
LEONHARD WEISS OÜ 13.08.2020 Lk 2/10
Nr 10084 Päri küla, Viljandi vald
Projekti koostamisel osalesid:
Projekteerija Ivo Maaten
Tel. +372 5282137
[email protected]
Tööprojekt Päri tänavavalgustuse rekonstrueerimine,
LEONHARD WEISS OÜ 13.08.2020 Lk 3/10
Nr 10084 Päri küla, Viljandi vald
Sisukord
1. Asukoht 4
2. Seletuskiri 5
2.1. Üldosa 5
2.2. Tehniline lahendus 6
2.2.1. Maakaabelliinid 6
2.2.2. Valgustus 6
2.2.3. Puutepingekaitse 7
3. Maastiku ja teede taastamine 7
4. Ehitustööde dokumenteerimine ja järelvalve 7
5. Käidujuhend 8
LISAD JA JOONISED
Lisa 1. Spetsifikatsioon ja mahud
Lisa 2. Lähtematerjalid
Lisa 3. ELV tehnilised tingimused ühiskasutuse jaoks
Lisa 3. Valgusti infoleht
Lisa 4. Valgusarvutus
Joonis 10084-1 Elektripaigaldise plaan
Joonis 10084-2 Elektriskeem
Joonis 10084-3 Kilbi skeem
Tööprojekt Päri tänavavalgustuse rekonstrueerimine,
LEONHARD WEISS OÜ 13.08.2020 Lk 4/10
Nr 10084 Päri küla, Viljandi vald
1. Asukoht
Joonis 1.1 Projekteeritud objekti asukohaplaan
Tööprojekt Päri tänavavalgustuse rekonstrueerimine,
LEONHARD WEISS OÜ 13.08.2020 Lk 5/10
Nr 10084 Päri küla, Viljandi vald
2. Seletuskiri
2.1. Üldosa
Käesoleva projektiga on lahendatud Viljandi maakonnas Viljandi vallas Päri tee ja
Kannikmäe tee T1 valgustuse rekonstrueerimine. Liinide projekteeritud pikkused koos
varuga on toodud elektriskeemidel ja spetsifikatsioonis, trasside projektsioonide pikkused
tööde mahtude tabelis.
Elektripaigaldise projekteerimisel on lähtutud Eesti Vabariigi seadustest ja õigusaktidest,
Eesti Standardikeskuse poolt välja antud ehitusvaldkonna standarditest ja
juhendmaterjalidest.
Projekti koostamisel aluseks võetud olulisemad standardid ja normid:
- CEN/TR 13201- 1:2014 Teevalgustus. Osa 1: Valgustusklasside valiku juhised
- EVS-EN 13201- 2:2015 Teevalgustus. Osa 2: Toimivusnõuded
- EVS-EN 13201- 3:2015 Teevalgustus. Osa 3: Toimivuse arvutamine
- EVS-EN 13201- 4:2015 Teevalgustus. Osa 4: Valgustusliku toimivuse mõõtemeetodid
- EVS-EN 13201- 5:2015 Teevalgustus – Energiatõhususnäitajad.
- EVS 843:2016 Linnatänavad
- EVS 932:2017 Ehitusprojekt
- EVS-HD 60364-4-41:2017 Madalpingelised elektripaigaldised. Osa 4-41: Kaitseviisid.
Kaitse elektrilöögi eest.
- EVS-HD 60364-4-43:2010 Madalpingelised elektripaigaldised. Osa 4-43: Kaitseviisid.
Liigvoolukaitse.
- Elektrilevi OÜ 0,4 – 20 kV võrgustandard
- Elektroonilise side seadus
Kolm päeva enne liiniehitustööde algust on ehitajal kohustus võtta ühendust kinnistute
valdajatega, teavitades neid tööde teostamisest nende maaüksusel ning arvestama nende
tingimuste ja nõudmistega ning tehnovõrkude valdajatega (vastavalt kooskõlastuse
tingimustele). Tööd teostatakse vastavalt tellija ja kohalikku omavalitsuse kehtestatud
korrale. Meetmed ohutuks tööks elektriseadmetel ja nende kaitsetsoonis määrata kindlaks
tööjuhatuse koosolekul enne tööde alustamist. Ehitustöödel või selle ettevalmistamisel
tekkinud küsimused ja probleemid, mida pole kajastatud käesolevas projektis või on
ebaselged/vastuolulised, lahendatakse töö käigus kooskõlastatult projekteerija ja tellijaga.
Ehitustööde käigus ja elektripaigaldiste hilisemal käidul juhinduda eespool toodud
eeskirjadest ja Eesti vabariigis kehtivatele normatiividest ja seadustest ning kinni pidada
töötervishoiu, tööohutuse ja elektriohutuse nõuetest ning headest tavadest.
Tööprojekt Päri tänavavalgustuse rekonstrueerimine,
LEONHARD WEISS OÜ 13.08.2020 Lk 6/10
Nr 10084 Päri küla, Viljandi vald
2.2. Tehniline lahendus
2.2.1. Maakaabelliinid
Projekteeritud kaablite parameetrid koos algus- ja lõpp-punktidega on toodud elektriskeemil,
kaablite kulgemine looduses on esitatud asendiplaanil, põhimaterjalid loetletud
spetsifikatsioonis ning tööde mahud on esitatud vormikohases tööde mahtude tabelis.
Kaabel paigaldada teedega ristumisel min 1,0 m (haljasalal 0,7) m sügavusel kaitsetorus.
Kaablitrass puhastada vajadusel vajalikus ulatuses puudest/võsast ja kividest. Ristumisel
kommunikatsioonidega juhinduda normidekohastest püst- ja horisontaalvahekaugustest
ning kooskõlastustes toodud tingimustest. Kaabli montaažil jälgida kaabli tootja poolt
lubatud painderaadiusi ja tõmbejõudusid. Ristuvale allmaarajatisele lähemal kui 2 m
kaevata üldjuhul käsitsi (vt. kooskõlastuste tingimusi). Ristumistel allmaarajatistega tuleb
kaabli paigaldussügavus täpsustada kohapeal ehituse käigus, tehes käsitsi kaevates
kindlaks nende täpse asukoha ja suuna.
Kogu kaablitrassi ulatuses tähistada kaabel märkelindiga.
Trassi paiknemine looduses kanda teostusjoonisele.
2.2.2. Valgustus
Valgustiteks on valitud Philips Digistreet valgustid 31W (BGP760 T25 1xLED39-
4S/830DM10), 41W (BGP761 T25 1xLED54-4S/830DM10), 51W (BGP761 T25 1xLED69-
4S/830DM10) LED lampidega. Bussipeatuses kasutada parempoolse optikaga 15W
BGP760 T25 1xLED18-4S/830DPR1 valgustit mis on eelprogrammeeritud hämardamisega
30% peale kell 23.00-06.00. Valgustite värvustemperatuur 3000K. Valgusti kaitseaste on
IP66 ja löögikindlus IK09. Valgustid paigaldada 6m metallmastidele ja 9 m puit- ja
raudbetoonmastidele (kasutadades maksimaalselt olemasolevaid maste). Valgustite
kinnitamisel kasutada 0,6 m ja 2,5m postikinnitusi. Päri tee valgustusklassiks on valitud M5,
Kannikmäe tee L1 ja Tiigi teel M6.
F-1 valgustid 11-19 ja F-2 valgustid 31-57 peavad olema eelprogrammeeritud
hämardusprogrammiga DDF3, ülejäänud valgustitel DDF2 (va bussipeatuse oma).
Pärioja alajaama masti 59 juurde paigaldada uus valgustuse juhtimiskilp. Kilbi toite jaoks
paigaldada kaabel AJ seinani, perspektiivse liitumiskilbi. Liitumiskilbi paigaldus toimub
Elektrilevi mahus, ja selleks peab Vallavalitsus esitama taotluse 3-faasile üleminekuks koos
liitumiskilbi asukoha muutmisega. Hetkel liitumine alajaamas, 1x50A, üleminekul arvestada
3x25A-ga.
Valgustites tuleb kasutada liigpingepiirikut (kaitsetase 1,5 kV, maksimaalne impulsspinge
10 kV). Liigpingepiirik peab olema paigaldatud valgusti liiteseadmesse ja ühendatud
jadamisi. Valgustil peab olema piisava varuga (ilmastikukindel, kiuline, hülsitud ja 3
sooneline kummikaabel) ja selle paigaldus peab toimuma sisetingimustes. Kaabel peab
ulatuma terviklikult (lisaühendusteta) valgustist kuni masti ühendusklemmideni, mis asuvad
teenindusluugi ava kohal/taga või kaitsmepesani mastil.
Tööprojekt Päri tänavavalgustuse rekonstrueerimine,
LEONHARD WEISS OÜ 13.08.2020 Lk 7/10
Nr 10084 Päri küla, Viljandi vald
2.2.3. Puutepingekaitse
Metallist maakaabli toitel olevad valgustusmastid varustada 6A sulavkaitsmetega.
Valgustusmastide ühendusklemmid isoleerida vastavalt II kaitseklassi nõuetele
(kahekordne isolatsioon). Kuna valgustitena on kasutatud II klassi valgusteid ja
valgustusmastis II klassi ühendusklemmikomplekti koos kaitsega, siis on kaitsejuhtide
kasutamine ja valgustimastide juhtivate osade tahtlik ühendamine maandussüsteemiga
keelatud. PEN juhti ei tohi olla ühenduses valgustusmasti korpusega juhul, kui
valgustusmast ei ole täiendavalt maandatud. Kuna PEN-juhi potentsiaal võib olla erinev
masti lähiümbruse potentsiaalist, st valgustusmasti puudutamisel võib tekkida elektrilöögi
oht. Samas tuleb maandamata mastikorpuses paigalda ühendusklemmidele kahekordne
isolatsioon, mis tagab II klassi nõuetele vastava kaitse, st. katta ühendusklemmid täiendava
isolatsioonikihiga.
Valgustuse juhtimiskilpi on projekteeritud liinikaitselülitid, mis peavad lühise korral
rakenduma 5 sekundi jooksul.
3. Maastiku ja teede taastamine
Ehitus- ja demonteerimistööde käigus tekkinud kahjustuste ulatus sõltub ehitusajast.
Ehitajal lasub kohustus taastada ehitustöödele eelnenud olukord; muuhulgas tuleb taastada
ehituse käigus kahjustada saanud pinnas, siluda ja täita mehhanismide poolt tekitatud jäljed
ning demonteeritud liini mastiaugud, samuti vajunud pinnasega kaablitrass. Kõlvikult
koristada tööde käigus tekkinud ehitusjäätmed ja muu ehituspraht.
Kaevealade katted taastada vähemalt töödele eelnevas seisus. Kaevis tihendada tagasitäite
käigus kihtide kaupa. Hilisemate erimeelsuste vältimiseks on soovitav koos huvitatud
instantsidega fikseerida (fotod vmt) olukord enne ehitustööde algust ja pärast ehitustööde
lõppu.
Enne tööde alustamist on vajalik hankida kaevetööde luba ning pinnakatete taastamine
peab toimuma vastavalt kohaliku omavalituse poolt kehtestatud normidele.
Tööde teostamisel kasutada keskkonnasõbralikke meetodeid.
Pärast ehitustööde lõppu tööplats puhastatakse ja korrastatakse. Rikutud haljastus
taastatakse. Kõik ehitusjäätmed ja ajutised tarindid kõrvaldatakse, lammutatud või
vigastatud piirded taastatakse.
4. Ehitustööde dokumenteerimine ja järelvalve
Ehitustööde dokumenteerimisel lähtuda Eesti Vabariigi “Ehitusseadustik” protseduurist.
Ehituse järelevalvet teostab tellija poolt volitatud isik või ettevõte. Kõik kõrvalekalded
projektist kooskõlastada kõigi huvitatud instantsidega s.h. tellija ja projekteerijaga ning
fikseerida kirjalikult.
Tööprojekt Päri tänavavalgustuse rekonstrueerimine,
LEONHARD WEISS OÜ 13.08.2020 Lk 8/10
Nr 10084 Päri küla, Viljandi vald
5. Käidujuhend
Käesolev juhend sätestab käsitletava elektripaigaldise kasutamise ja hooldamise üldised
nõuded. Juhend on koostatud vastavalt eeskirjadele EVS-EN 50110-1:2013,
“Elektripaigaldiste käit, osa 1: Üldnõuded ”, lähtudes "Seadme ohutuse seadusest ja sealt
tulenevatest viidetest teistele standarditele ja määrustele.
Projekteeritud elektripaigaldise kasutustingimused ei esita kõrgendatud nõudmisi
kasutusele ja hooldusele. Seadmete ja aparaatide hooldust teha vastavalt tootja poolt antud
juhistele. Valgusteid puhastada ja lampe vahetada vastavalt vajadusele.
Peale valmisehitamist teostab elektripaigaldise ehitaja paigaldise elektrimõõtmised,
vajalikud katsetused ja organiseerib tehnilise kontrolli teostuse, et saada kinnitust
elektripaigaldise kasutuskõlblikkuses ning annab paigaldise omanikule üle järgmise
dokumentatsiooni:
• Elektripaigaldise teostusjoonised.
• Kaetud tööde aktid süvistatud juhtmestiku ja maasse paigaldatud kaablite kohta.
• Elektrimõõtmiste protokollid.
• Tööde vastuvõtu-üleandmisakt.
• Tehnilise kontrolliakt.
Pärast elektripaigaldise kasutuselevõttu tuleb teha seadmete ja liinitrassi ülevaatus peale
esimest ekspluatatsiooniaastat. Ülevaatus teha päevasel ajal, kontrollides põhjalikult
elektriseadmete kõiki elemente. Kontrollimisel pöörata erilist tähelepanu järgmistele
elementidele:
• mastide, valgustite, jaotus-lülituskilpide ja teiste seadmete seisukorrale
• kaablite ja juhtmete kinnituste seisukorrale
• märkide, plakatite, hoiatuste ja pealkirjade olemasolule
Seadmete ülevaatusel täita ülevaatuse leht ja kanda sellele avastatud defektid. Defektide
avastamisel määratakse selle kõrvaldamise viis ja aeg tellija poolt.
Elektripaigaldise omanik peab tagama, et elektripaigaldist kasutatakse õigusaktides
kehtestatud nõuete kohaselt ning vastutab temale kuuluva paigaldise korrasoleku eest ja
peab tagama selle käidukorralduse. Juhtmete lahtiühendamine või seadmete vahetamine
peab teostama vajalikku elektrialast haridust ja oskust omav isik (elektrialaisik). Viimane
hõlmab ka kõiki hooldustöid, mille käigus on vajalik kaitsekatete eemaldamine, (kaitseaste
muutub väiksemaks, kui IP20). Tööde loetelu, käsitletavas elektripaigaldises, mida võib teha
tavaisik, koostab elektripaigaldise käidukorraldaja poolt täiendavalt. Elektritööde teostamise
vajadusel annab loa tööde alustamiseks elektripaigaldise käidukorraldaja.
Käiduohtus
Enne töötoimingu sooritamist või käiduga seotud tegevust elektripaigaldises, selle juures või
lähedal tuleb selgeks teha elektriohud, nende allikad ja riski olemus. Seejuures tuleb
Tööprojekt Päri tänavavalgustuse rekonstrueerimine,
LEONHARD WEISS OÜ 13.08.2020 Lk 9/10
Nr 10084 Päri küla, Viljandi vald
üksikasjalikult kavandada tegevuse või töötoimingu sooritamise selline viis, mis tagaks
elektriohutuse. Tööd, mille juures elektriohu või trauma vältimiseks on vaja tehnilisi teadmisi
või kogemusi, tohib ette võtta ainult isik, kellel on sellised teadmised või kogemused või kes
töötab pideva järelvalve all. Kõigile elektripaigaldises, selle juures või lähedal
töötoimingutega seotud isikutele tuleb nende tööks vajalikus mahus selgeks teha
ohutusnõuded, ohutuseeskirjad ja ettevõttesisesed juhised. Töötajad on kohustatud neid
nõudeid, eeskirju ja juhiseid jälgima.
Elektripaigaldiste käidu, tehnohoolde teostamise ja tegemise korra töötab välja käidujuht või
selleks õigust omav firma, kehtivate seaduste ja eeskirjade kohaselt.
Nõuded
Elektriohu vältimiseks tuleb lähtuda kehtivatest eeskirjades ja standardites välja toodud
toimingutel kasutada sobivaid tööriistu ja –seadmeid ettenähtud viisil.
Elektriseadmeid võib paigaldada ja remontida vaid kvalifitseeritud elektrik, arvestades
seadme valmistajatehase poolt esitatud ja kehtivaid eeskirju.
Isolatsioonirikete korral väldib aparaatide metallkorpuste pinge alla sattumist
kaitseseadmete kiire rakendumine. Sellest tulenevalt on keelatud projektis ettenähtud
nimivooluga kaitseseadmete ja sulav-kaitsmete remont.
Installatsioonil lähtuda kehtivates standardite nõuetest.
Toimingu lõpetamisel tuleb teostada ülevaatus, mille eesmärgiks on kas elektripaigaldis
vastab asjaomaste standarditega määratud tehnika- ja ohutusnõuetele.
Pingestamist võib teostada selleks pädev isik.
Koostas: Ivo Maaten
Tööprojekt Päri tänavavalgustuse rekonstrueerimine,
LEONHARD WEISS OÜ 13.08.2020 Lk 10/10
Nr 10084 Päri küla, Viljandi vald
LISAD JA JOONISED
Lisa 1. Spetsifikatsioon ja mahud
Lisa 2. Lähtematerjalid
Lisa 3. ELV tehnilised tingimused ühiskasutuse jaoks
Lisa 3. Valgusti infoleht
Lisa 4. Valgusarvutus
Joonis 10084-1 Elektripaigaldise plaan
Joonis 10084-2 Elektriskeem
Joonis 10084-3 Kilbi skeem
TAOTLUS KOOSKÕLASTADA TEHNOVÕRGU JA -RAJATISE PROJEKT Kellele MAANTEEAMET Registrikood 7000 1490 Juriidiline aadress Tallinn 10916, Pärnu mnt 463 a Kellelt Asutuse nimi LEONHARD WEISS OÜ Registri- või isikukood 12083348 Juriidiline aadress või elukoht Vesse 8, Tallinn Kontaktaadress Vesse 8, Tallinn FORMTEXT Telefon 5282137 E-post i.maaten @leonhard-weiss.com 1. E sitatavad materjalid: Dokumendi liik (ehitusprojekt, tehniliste tingimuste või nõuete taotlus) Dokumenti nimetus (esitatava dokumendi täpne nimetus) Dokumendi nr. Ehitusprojekt 100 84 -1 Elektri paigalduse plaan 100 84 FORMTEXT FORMTEXT 2. O bjekti asukoht ( maakond, vald, küla, tee nr, nimetus, asukoht teel ( km -vähemalt 10 m täpsusega ja/või vajadusel koordinaadid ) 92 Tartu-Viljandi-Kilingi-Nõmme tee , p aralleelkulgemine teemaal 80,24-80 ,26 km ; valgustite vahetus 80,16-80,38 km 3. Selgitus kavandatava tegevuse kohta, kavandatav läbiviimise aeg Tänavavalgustuse lisamasti paigaldus ja olemasolevate valgustite vahetus FORMTEXT 4. Põhjendus vajaduse kohta projekteerida tehnovõrk ja –rajatis riigitee maale ( Asjaõigusseadus § 158 lõige 1 ja § 158 1 lõige 1) 5 . Eelnevad kooskõlastused teistelt Maanteeameti osakondadelt FORMTEXT T aotleja Ees- ja perekonnanimi Ivo Maaten (juriidilisest isikust taotleja puhul juriidilise isiku esindaja) Allkiri Taotluse esitamise kuupäev 25 . 0 8 .20 20
Saatja: Liis Ninn <
[email protected]>
Saadetud: 27.08.2020 08:25
Adressaat: Liis Ninn <
[email protected]>
Teema: FW: Kooskõlastamiseks - 10084 Päri tänavavalgustuse rekonstrueerimine, Päri küla,
Viljandi vald
Manused: 10084-Taotlus_tehnovõrgu_rajamiseks.asice
From: Maaten, Ivo <
[email protected]>
Sent: Tuesday, August 25, 2020 4:27 PM
To:
[email protected]
Subject: Kooskõlastamiseks - 10084 Päri tänavavalgustuse rekonstrueerimine, Päri küla, Viljandi vald
Tere,
Palun kooskõlastada.
Lugupidamisega
LEONHARD WEISS OÜ
elektriteenuste divisjon
põhja projekteerimispiirkond
Ivo Maaten
Projekteerija
Vesse 8, 11415 Tallinn
Mob +372 52 82 137
[email protected]
http://www.leonhard-weiss.ee
LEONHARD WEISS grupi ettevõte
Meie juriidiliste teadetega tutvumiseks külastage meie kodulehte.