TJA vastus Saksa Administratsiooni t-kirjale 07.04.2016

Tarbijakaitse ja Tehnilise Järelevalve Amet · 9. mai 2016
Viit
16-0035-007
Registreeritud
9. mai 2016
Dokumendi liik
Väljaminev kiri
Adressaat
Bundesnetzagentur für Elektrizität, Gas, Telekommunikation, Post und Eisenbahnen
Funktsioon
18 Sageduste haldus (2014-2017)
Sari
18-5 Sagedushalduse sisenevad ja väljuvad koordinatsioonid
Toimik
16-0035
Vastutaja
TJA Migratsioon (Sagedushalduse osakond)

Failid

  • 📎EST-G_09.05.2016.txt22 KB
  • 📎Letter_Template_16-0035-007.docx17 KB

Sisu (failidest)

<HEAD> t_char_set = ISO-8859-1 t_email_addr = [email protected] t_adm = EST </HEAD> <NOTICE> t_notice_type = GT1 t_fragment = GE06D t_action = ADD t_adm_ref_id = P�RNU/24 t_freq_assgn = 498.000 t_ctry = EST t_site_name = P�RNU t_long = +0243455 t_lat = +582259 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 197 t_erp_h_dbw = 43.000 t_hgt_agl = 187 t_polar = H t_site_alt = 10 <ANT_HGT> t_eff_hgt@azm0 = 179 t_eff_hgt@azm10 = 176 t_eff_hgt@azm20 = 176 t_eff_hgt@azm30 = 175 t_eff_hgt@azm40 = 176 t_eff_hgt@azm50 = 179 t_eff_hgt@azm60 = 182 t_eff_hgt@azm70 = 179 t_eff_hgt@azm80 = 178 t_eff_hgt@azm90 = 178 t_eff_hgt@azm100 = 176 t_eff_hgt@azm110 = 177 t_eff_hgt@azm120 = 180 t_eff_hgt@azm130 = 175 t_eff_hgt@azm140 = 179 t_eff_hgt@azm150 = 181 t_eff_hgt@azm160 = 183 t_eff_hgt@azm170 = 182 t_eff_hgt@azm180 = 188 t_eff_hgt@azm190 = 194 t_eff_hgt@azm200 = 196 t_eff_hgt@azm210 = 196 t_eff_hgt@azm220 = 196 t_eff_hgt@azm230 = 197 t_eff_hgt@azm240 = 197 t_eff_hgt@azm250 = 196 t_eff_hgt@azm260 = 195 t_eff_hgt@azm270 = 195 t_eff_hgt@azm280 = 191 t_eff_hgt@azm290 = 187 t_eff_hgt@azm300 = 184 t_eff_hgt@azm310 = 182 t_eff_hgt@azm320 = 181 t_eff_hgt@azm330 = 180 t_eff_hgt@azm340 = 182 t_eff_hgt@azm350 = 182 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = P�RNU/24 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-08-05-PRN </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = P�RNU/34 t_freq_assgn = 578.000 t_ctry = EST t_site_name = P�RNU t_long = +0243433 t_lat = +582240 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 194 t_erp_h_dbw = 43.000 t_hgt_agl = 187 t_polar = H t_site_alt = 7 <ANT_HGT> t_eff_hgt@azm0 = 177 t_eff_hgt@azm10 = 173 t_eff_hgt@azm20 = 173 t_eff_hgt@azm30 = 172 t_eff_hgt@azm40 = 175 t_eff_hgt@azm50 = 175 t_eff_hgt@azm60 = 180 t_eff_hgt@azm70 = 177 t_eff_hgt@azm80 = 175 t_eff_hgt@azm90 = 176 t_eff_hgt@azm100 = 174 t_eff_hgt@azm110 = 173 t_eff_hgt@azm120 = 174 t_eff_hgt@azm130 = 175 t_eff_hgt@azm140 = 177 t_eff_hgt@azm150 = 177 t_eff_hgt@azm160 = 180 t_eff_hgt@azm170 = 180 t_eff_hgt@azm180 = 189 t_eff_hgt@azm190 = 191 t_eff_hgt@azm200 = 194 t_eff_hgt@azm210 = 194 t_eff_hgt@azm220 = 194 t_eff_hgt@azm230 = 194 t_eff_hgt@azm240 = 194 t_eff_hgt@azm250 = 194 t_eff_hgt@azm260 = 193 t_eff_hgt@azm270 = 192 t_eff_hgt@azm280 = 187 t_eff_hgt@azm290 = 187 t_eff_hgt@azm300 = 182 t_eff_hgt@azm310 = 182 t_eff_hgt@azm320 = 180 t_eff_hgt@azm330 = 177 t_eff_hgt@azm340 = 178 t_eff_hgt@azm350 = 179 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = P�RNU/34 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-09-05-PRN </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-07-05-PRN </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = P�RNU/38 t_freq_assgn = 610.000 t_ctry = EST t_site_name = P�RNU t_long = +0243433 t_lat = +582240 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 194 t_erp_h_dbw = 43.000 t_hgt_agl = 187 t_polar = H t_site_alt = 7 <ANT_HGT> t_eff_hgt@azm0 = 177 t_eff_hgt@azm10 = 173 t_eff_hgt@azm20 = 173 t_eff_hgt@azm30 = 172 t_eff_hgt@azm40 = 175 t_eff_hgt@azm50 = 175 t_eff_hgt@azm60 = 180 t_eff_hgt@azm70 = 177 t_eff_hgt@azm80 = 175 t_eff_hgt@azm90 = 176 t_eff_hgt@azm100 = 174 t_eff_hgt@azm110 = 173 t_eff_hgt@azm120 = 174 t_eff_hgt@azm130 = 175 t_eff_hgt@azm140 = 177 t_eff_hgt@azm150 = 177 t_eff_hgt@azm160 = 180 t_eff_hgt@azm170 = 180 t_eff_hgt@azm180 = 189 t_eff_hgt@azm190 = 191 t_eff_hgt@azm200 = 194 t_eff_hgt@azm210 = 194 t_eff_hgt@azm220 = 194 t_eff_hgt@azm230 = 194 t_eff_hgt@azm240 = 194 t_eff_hgt@azm250 = 194 t_eff_hgt@azm260 = 193 t_eff_hgt@azm270 = 192 t_eff_hgt@azm280 = 187 t_eff_hgt@azm290 = 187 t_eff_hgt@azm300 = 182 t_eff_hgt@azm310 = 182 t_eff_hgt@azm320 = 180 t_eff_hgt@azm330 = 177 t_eff_hgt@azm340 = 178 t_eff_hgt@azm350 = 179 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = P�RNU/38 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-06-05-PRN </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = P�RNU/41 t_freq_assgn = 634.000 t_ctry = EST t_site_name = P�RNU t_long = +0243455 t_lat = +582259 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 197 t_erp_h_dbw = 43.000 t_hgt_agl = 187 t_polar = H t_site_alt = 10 <ANT_HGT> t_eff_hgt@azm0 = 179 t_eff_hgt@azm10 = 176 t_eff_hgt@azm20 = 176 t_eff_hgt@azm30 = 175 t_eff_hgt@azm40 = 176 t_eff_hgt@azm50 = 179 t_eff_hgt@azm60 = 182 t_eff_hgt@azm70 = 179 t_eff_hgt@azm80 = 178 t_eff_hgt@azm90 = 178 t_eff_hgt@azm100 = 176 t_eff_hgt@azm110 = 177 t_eff_hgt@azm120 = 180 t_eff_hgt@azm130 = 175 t_eff_hgt@azm140 = 179 t_eff_hgt@azm150 = 181 t_eff_hgt@azm160 = 183 t_eff_hgt@azm170 = 182 t_eff_hgt@azm180 = 188 t_eff_hgt@azm190 = 194 t_eff_hgt@azm200 = 196 t_eff_hgt@azm210 = 196 t_eff_hgt@azm220 = 196 t_eff_hgt@azm230 = 197 t_eff_hgt@azm240 = 197 t_eff_hgt@azm250 = 196 t_eff_hgt@azm260 = 195 t_eff_hgt@azm270 = 195 t_eff_hgt@azm280 = 191 t_eff_hgt@azm290 = 187 t_eff_hgt@azm300 = 184 t_eff_hgt@azm310 = 182 t_eff_hgt@azm320 = 181 t_eff_hgt@azm330 = 180 t_eff_hgt@azm340 = 182 t_eff_hgt@azm350 = 182 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = P�RNU/41 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = P�RNU/46 t_freq_assgn = 674.000 t_ctry = EST t_site_name = P�RNU t_long = +0243433 t_lat = +582240 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 194 t_erp_h_dbw = 43.000 t_hgt_agl = 187 t_polar = H t_site_alt = 7 <ANT_HGT> t_eff_hgt@azm0 = 177 t_eff_hgt@azm10 = 173 t_eff_hgt@azm20 = 173 t_eff_hgt@azm30 = 172 t_eff_hgt@azm40 = 175 t_eff_hgt@azm50 = 175 t_eff_hgt@azm60 = 180 t_eff_hgt@azm70 = 177 t_eff_hgt@azm80 = 175 t_eff_hgt@azm90 = 176 t_eff_hgt@azm100 = 174 t_eff_hgt@azm110 = 173 t_eff_hgt@azm120 = 174 t_eff_hgt@azm130 = 175 t_eff_hgt@azm140 = 177 t_eff_hgt@azm150 = 177 t_eff_hgt@azm160 = 180 t_eff_hgt@azm170 = 180 t_eff_hgt@azm180 = 189 t_eff_hgt@azm190 = 191 t_eff_hgt@azm200 = 194 t_eff_hgt@azm210 = 194 t_eff_hgt@azm220 = 194 t_eff_hgt@azm230 = 194 t_eff_hgt@azm240 = 194 t_eff_hgt@azm250 = 194 t_eff_hgt@azm260 = 193 t_eff_hgt@azm270 = 192 t_eff_hgt@azm280 = 187 t_eff_hgt@azm290 = 187 t_eff_hgt@azm300 = 182 t_eff_hgt@azm310 = 182 t_eff_hgt@azm320 = 180 t_eff_hgt@azm330 = 177 t_eff_hgt@azm340 = 178 t_eff_hgt@azm350 = 179 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = P�RNU/46 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = ORISSAARE/24 t_freq_assgn = 498.000 t_ctry = EST t_site_name = ORISSAARE t_long = +0230357 t_lat = +583328 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 189 t_erp_h_dbw = 37.782 t_hgt_agl = 188 t_polar = H t_site_alt = 1 <ANT_HGT> t_eff_hgt@azm0 = 189 t_eff_hgt@azm10 = 186 t_eff_hgt@azm20 = 183 t_eff_hgt@azm30 = 179 t_eff_hgt@azm40 = 175 t_eff_hgt@azm50 = 171 t_eff_hgt@azm60 = 176 t_eff_hgt@azm70 = 180 t_eff_hgt@azm80 = 180 t_eff_hgt@azm90 = 183 t_eff_hgt@azm100 = 187 t_eff_hgt@azm110 = 187 t_eff_hgt@azm120 = 188 t_eff_hgt@azm130 = 185 t_eff_hgt@azm140 = 184 t_eff_hgt@azm150 = 185 t_eff_hgt@azm160 = 182 t_eff_hgt@azm170 = 182 t_eff_hgt@azm180 = 181 t_eff_hgt@azm190 = 180 t_eff_hgt@azm200 = 177 t_eff_hgt@azm210 = 176 t_eff_hgt@azm220 = 175 t_eff_hgt@azm230 = 174 t_eff_hgt@azm240 = 173 t_eff_hgt@azm250 = 175 t_eff_hgt@azm260 = 174 t_eff_hgt@azm270 = 173 t_eff_hgt@azm280 = 172 t_eff_hgt@azm290 = 175 t_eff_hgt@azm300 = 173 t_eff_hgt@azm310 = 181 t_eff_hgt@azm320 = 187 t_eff_hgt@azm330 = 189 t_eff_hgt@azm340 = 189 t_eff_hgt@azm350 = 189 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = ORISSAARE/24 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-08-06-ORS </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = ORISSAARE/26 t_freq_assgn = 514.000 t_ctry = EST t_site_name = ORISSAARE t_long = +0230357 t_lat = +583328 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 189 t_erp_h_dbw = 37.782 t_hgt_agl = 188 t_polar = H t_site_alt = 1 <ANT_HGT> t_eff_hgt@azm0 = 189 t_eff_hgt@azm10 = 186 t_eff_hgt@azm20 = 183 t_eff_hgt@azm30 = 179 t_eff_hgt@azm40 = 175 t_eff_hgt@azm50 = 171 t_eff_hgt@azm60 = 176 t_eff_hgt@azm70 = 180 t_eff_hgt@azm80 = 180 t_eff_hgt@azm90 = 183 t_eff_hgt@azm100 = 187 t_eff_hgt@azm110 = 187 t_eff_hgt@azm120 = 188 t_eff_hgt@azm130 = 185 t_eff_hgt@azm140 = 184 t_eff_hgt@azm150 = 185 t_eff_hgt@azm160 = 182 t_eff_hgt@azm170 = 182 t_eff_hgt@azm180 = 181 t_eff_hgt@azm190 = 180 t_eff_hgt@azm200 = 177 t_eff_hgt@azm210 = 176 t_eff_hgt@azm220 = 175 t_eff_hgt@azm230 = 174 t_eff_hgt@azm240 = 173 t_eff_hgt@azm250 = 175 t_eff_hgt@azm260 = 174 t_eff_hgt@azm270 = 173 t_eff_hgt@azm280 = 172 t_eff_hgt@azm290 = 175 t_eff_hgt@azm300 = 173 t_eff_hgt@azm310 = 181 t_eff_hgt@azm320 = 187 t_eff_hgt@azm330 = 189 t_eff_hgt@azm340 = 189 t_eff_hgt@azm350 = 189 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = ORISSAARE/26 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-09-06-ORS </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = TLN_TELETORN/34 t_freq_assgn = 578.000 t_ctry = EST t_site_name = TALLINN_TELETORN t_long = +0245315 t_lat = +592816 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 312 t_erp_h_dbw = 43.000 t_hgt_agl = 289 t_polar = H t_site_alt = 24 <ANT_HGT> t_eff_hgt@azm0 = 302 t_eff_hgt@azm10 = 308 t_eff_hgt@azm20 = 311 t_eff_hgt@azm30 = 312 t_eff_hgt@azm40 = 312 t_eff_hgt@azm50 = 311 t_eff_hgt@azm60 = 311 t_eff_hgt@azm70 = 305 t_eff_hgt@azm80 = 291 t_eff_hgt@azm90 = 278 t_eff_hgt@azm100 = 275 t_eff_hgt@azm110 = 273 t_eff_hgt@azm120 = 272 t_eff_hgt@azm130 = 269 t_eff_hgt@azm140 = 270 t_eff_hgt@azm150 = 272 t_eff_hgt@azm160 = 272 t_eff_hgt@azm170 = 269 t_eff_hgt@azm180 = 266 t_eff_hgt@azm190 = 266 t_eff_hgt@azm200 = 266 t_eff_hgt@azm210 = 267 t_eff_hgt@azm220 = 267 t_eff_hgt@azm230 = 272 t_eff_hgt@azm240 = 295 t_eff_hgt@azm250 = 304 t_eff_hgt@azm260 = 310 t_eff_hgt@azm270 = 312 t_eff_hgt@azm280 = 312 t_eff_hgt@azm290 = 312 t_eff_hgt@azm300 = 312 t_eff_hgt@azm310 = 308 t_eff_hgt@azm320 = 305 t_eff_hgt@azm330 = 292 t_eff_hgt@azm340 = 292 t_eff_hgt@azm350 = 296 </ANT_HGT> <ANT_DIAGR_H> t_attn@azm0 = 5.0 t_attn@azm10 = 5.5 t_attn@azm20 = 3.0 t_attn@azm30 = 0.5 t_attn@azm40 = 0.0 t_attn@azm50 = 1.0 t_attn@azm60 = 4.0 t_attn@azm70 = 5.0 t_attn@azm80 = 5.5 t_attn@azm90 = 3.0 t_attn@azm100 = 1.0 t_attn@azm110 = 0.0 t_attn@azm120 = 1.0 t_attn@azm130 = 3.5 t_attn@azm140 = 5.0 t_attn@azm150 = 5.5 t_attn@azm160 = 4.0 t_attn@azm170 = 1.0 t_attn@azm180 = 0.0 t_attn@azm190 = 0.5 t_attn@azm200 = 3.0 t_attn@azm210 = 5.0 t_attn@azm220 = 5.5 t_attn@azm230 = 5.0 t_attn@azm240 = 2.0 t_attn@azm250 = 0.0 t_attn@azm260 = 0.5 t_attn@azm270 = 2.5 t_attn@azm280 = 5.0 t_attn@azm290 = 5.5 t_attn@azm300 = 5.0 t_attn@azm310 = 2.0 t_attn@azm320 = 0.0 t_attn@azm330 = 0.0 t_attn@azm340 = 2.0 t_attn@azm350 = 4.5 </ANT_DIAGR_H> t_ant_dir = D t_ref_plan_cfg = RPC1 t_sfn_id = TLN_TELETORN/34 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-09-01-TLN </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-08-01-TLN </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = KOHTLA-N�MME/35 t_freq_assgn = 586.000 t_ctry = EST t_site_name = KOHTLA-N�MME t_long = +0271148 t_lat = +592053 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 277 t_erp_h_dbw = 41.761 t_hgt_agl = 235 t_polar = H t_site_alt = 50 <ANT_HGT> t_eff_hgt@azm0 = 275 t_eff_hgt@azm10 = 271 t_eff_hgt@azm20 = 261 t_eff_hgt@azm30 = 262 t_eff_hgt@azm40 = 252 t_eff_hgt@azm50 = 243 t_eff_hgt@azm60 = 244 t_eff_hgt@azm70 = 243 t_eff_hgt@azm80 = 242 t_eff_hgt@azm90 = 239 t_eff_hgt@azm100 = 236 t_eff_hgt@azm110 = 235 t_eff_hgt@azm120 = 235 t_eff_hgt@azm130 = 235 t_eff_hgt@azm140 = 235 t_eff_hgt@azm150 = 236 t_eff_hgt@azm160 = 241 t_eff_hgt@azm170 = 246 t_eff_hgt@azm180 = 251 t_eff_hgt@azm190 = 252 t_eff_hgt@azm200 = 254 t_eff_hgt@azm210 = 253 t_eff_hgt@azm220 = 253 t_eff_hgt@azm230 = 254 t_eff_hgt@azm240 = 254 t_eff_hgt@azm250 = 256 t_eff_hgt@azm260 = 257 t_eff_hgt@azm270 = 258 t_eff_hgt@azm280 = 259 t_eff_hgt@azm290 = 261 t_eff_hgt@azm300 = 262 t_eff_hgt@azm310 = 263 t_eff_hgt@azm320 = 269 t_eff_hgt@azm330 = 274 t_eff_hgt@azm340 = 277 t_eff_hgt@azm350 = 276 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = KOHTLA-N�MME/35 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-09-02-KTL </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = KOERU/47 t_freq_assgn = 682.000 t_ctry = EST t_site_name = KOERU t_long = +0260324 t_lat = +585829 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 353 t_erp_h_dbw = 39.294 t_hgt_agl = 335 t_polar = H t_site_alt = 100 <ANT_HGT> t_eff_hgt@azm0 = 327 t_eff_hgt@azm10 = 331 t_eff_hgt@azm20 = 335 t_eff_hgt@azm30 = 335 t_eff_hgt@azm40 = 334 t_eff_hgt@azm50 = 336 t_eff_hgt@azm60 = 340 t_eff_hgt@azm70 = 338 t_eff_hgt@azm80 = 338 t_eff_hgt@azm90 = 339 t_eff_hgt@azm100 = 340 t_eff_hgt@azm110 = 344 t_eff_hgt@azm120 = 347 t_eff_hgt@azm130 = 348 t_eff_hgt@azm140 = 350 t_eff_hgt@azm150 = 353 t_eff_hgt@azm160 = 350 t_eff_hgt@azm170 = 348 t_eff_hgt@azm180 = 348 t_eff_hgt@azm190 = 348 t_eff_hgt@azm200 = 345 t_eff_hgt@azm210 = 346 t_eff_hgt@azm220 = 346 t_eff_hgt@azm230 = 346 t_eff_hgt@azm240 = 344 t_eff_hgt@azm250 = 344 t_eff_hgt@azm260 = 342 t_eff_hgt@azm270 = 340 t_eff_hgt@azm280 = 333 t_eff_hgt@azm290 = 333 t_eff_hgt@azm300 = 331 t_eff_hgt@azm310 = 327 t_eff_hgt@azm320 = 324 t_eff_hgt@azm330 = 322 t_eff_hgt@azm340 = 320 t_eff_hgt@azm350 = 325 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = KOERU/47 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-08-03-KRU </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = KOERU/25 t_freq_assgn = 506.000 t_ctry = EST t_site_name = KOERU t_long = +0260324 t_lat = +585829 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 353 t_erp_h_dbw = 39.294 t_hgt_agl = 335 t_polar = H t_site_alt = 100 <ANT_HGT> t_eff_hgt@azm0 = 327 t_eff_hgt@azm10 = 331 t_eff_hgt@azm20 = 335 t_eff_hgt@azm30 = 335 t_eff_hgt@azm40 = 334 t_eff_hgt@azm50 = 336 t_eff_hgt@azm60 = 340 t_eff_hgt@azm70 = 338 t_eff_hgt@azm80 = 338 t_eff_hgt@azm90 = 339 t_eff_hgt@azm100 = 340 t_eff_hgt@azm110 = 344 t_eff_hgt@azm120 = 347 t_eff_hgt@azm130 = 348 t_eff_hgt@azm140 = 350 t_eff_hgt@azm150 = 353 t_eff_hgt@azm160 = 350 t_eff_hgt@azm170 = 348 t_eff_hgt@azm180 = 348 t_eff_hgt@azm190 = 348 t_eff_hgt@azm200 = 345 t_eff_hgt@azm210 = 346 t_eff_hgt@azm220 = 346 t_eff_hgt@azm230 = 346 t_eff_hgt@azm240 = 344 t_eff_hgt@azm250 = 344 t_eff_hgt@azm260 = 342 t_eff_hgt@azm270 = 340 t_eff_hgt@azm280 = 333 t_eff_hgt@azm290 = 333 t_eff_hgt@azm300 = 331 t_eff_hgt@azm310 = 327 t_eff_hgt@azm320 = 324 t_eff_hgt@azm330 = 322 t_eff_hgt@azm340 = 320 t_eff_hgt@azm350 = 325 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = KOERU/25 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-09-03-KRU </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-10-03-KRU </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = VALGJ�RVE/25 t_freq_assgn = 506.000 t_ctry = EST t_site_name = VALGJ�RVE t_long = +0264041 t_lat = +580550 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 383 t_erp_h_dbw = 43.000 t_hgt_agl = 336 t_polar = H t_site_alt = 150 <ANT_HGT> t_eff_hgt@azm0 = 360 t_eff_hgt@azm10 = 372 t_eff_hgt@azm20 = 374 t_eff_hgt@azm30 = 372 t_eff_hgt@azm40 = 374 t_eff_hgt@azm50 = 369 t_eff_hgt@azm60 = 372 t_eff_hgt@azm70 = 373 t_eff_hgt@azm80 = 383 t_eff_hgt@azm90 = 379 t_eff_hgt@azm100 = 374 t_eff_hgt@azm110 = 361 t_eff_hgt@azm120 = 348 t_eff_hgt@azm130 = 347 t_eff_hgt@azm140 = 346 t_eff_hgt@azm150 = 343 t_eff_hgt@azm160 = 343 t_eff_hgt@azm170 = 337 t_eff_hgt@azm180 = 331 t_eff_hgt@azm190 = 319 t_eff_hgt@azm200 = 313 t_eff_hgt@azm210 = 309 t_eff_hgt@azm220 = 307 t_eff_hgt@azm230 = 313 t_eff_hgt@azm240 = 323 t_eff_hgt@azm250 = 335 t_eff_hgt@azm260 = 343 t_eff_hgt@azm270 = 347 t_eff_hgt@azm280 = 348 t_eff_hgt@azm290 = 348 t_eff_hgt@azm300 = 345 t_eff_hgt@azm310 = 352 t_eff_hgt@azm320 = 338 t_eff_hgt@azm330 = 347 t_eff_hgt@azm340 = 348 t_eff_hgt@azm350 = 356 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = VALGJ�RVE/25 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-07-04-VLG </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = VALGJ�RVE/43 t_freq_assgn = 650.000 t_ctry = EST t_site_name = VALGJ�RVE t_long = +0264038 t_lat = +580553 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 413 t_erp_h_dbw = 40.000 t_hgt_agl = 336 t_polar = H t_site_alt = 180 <ANT_HGT> t_eff_hgt@azm0 = 389 t_eff_hgt@azm10 = 400 t_eff_hgt@azm20 = 404 t_eff_hgt@azm30 = 402 t_eff_hgt@azm40 = 404 t_eff_hgt@azm50 = 400 t_eff_hgt@azm60 = 402 t_eff_hgt@azm70 = 401 t_eff_hgt@azm80 = 413 t_eff_hgt@azm90 = 409 t_eff_hgt@azm100 = 403 t_eff_hgt@azm110 = 392 t_eff_hgt@azm120 = 379 t_eff_hgt@azm130 = 377 t_eff_hgt@azm140 = 377 t_eff_hgt@azm150 = 372 t_eff_hgt@azm160 = 372 t_eff_hgt@azm170 = 362 t_eff_hgt@azm180 = 360 t_eff_hgt@azm190 = 347 t_eff_hgt@azm200 = 345 t_eff_hgt@azm210 = 340 t_eff_hgt@azm220 = 337 t_eff_hgt@azm230 = 343 t_eff_hgt@azm240 = 354 t_eff_hgt@azm250 = 365 t_eff_hgt@azm260 = 375 t_eff_hgt@azm270 = 377 t_eff_hgt@azm280 = 378 t_eff_hgt@azm290 = 380 t_eff_hgt@azm300 = 380 t_eff_hgt@azm310 = 378 t_eff_hgt@azm320 = 371 t_eff_hgt@azm330 = 376 t_eff_hgt@azm340 = 379 t_eff_hgt@azm350 = 388 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = VALGJ�RVE/43 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = GT1 t_action = ADD t_fragment = GE06D t_action = ADD t_adm_ref_id = VALGJ�RVE/44 t_freq_assgn = 658.000 t_ctry = EST t_site_name = VALGJ�RVE t_long = +0264038 t_lat = +580553 t_d_inuse = 2017-07-01 t_is_pub_req = TRUE t_assgn_code = L t_plan_entry = 2 t_eff_hgtmax = 413 t_erp_h_dbw = 40.000 t_hgt_agl = 336 t_polar = H t_site_alt = 180 <ANT_HGT> t_eff_hgt@azm0 = 389 t_eff_hgt@azm10 = 400 t_eff_hgt@azm20 = 404 t_eff_hgt@azm30 = 402 t_eff_hgt@azm40 = 404 t_eff_hgt@azm50 = 400 t_eff_hgt@azm60 = 402 t_eff_hgt@azm70 = 401 t_eff_hgt@azm80 = 413 t_eff_hgt@azm90 = 409 t_eff_hgt@azm100 = 403 t_eff_hgt@azm110 = 392 t_eff_hgt@azm120 = 379 t_eff_hgt@azm130 = 377 t_eff_hgt@azm140 = 377 t_eff_hgt@azm150 = 372 t_eff_hgt@azm160 = 372 t_eff_hgt@azm170 = 362 t_eff_hgt@azm180 = 360 t_eff_hgt@azm190 = 347 t_eff_hgt@azm200 = 345 t_eff_hgt@azm210 = 340 t_eff_hgt@azm220 = 337 t_eff_hgt@azm230 = 343 t_eff_hgt@azm240 = 354 t_eff_hgt@azm250 = 365 t_eff_hgt@azm260 = 375 t_eff_hgt@azm270 = 377 t_eff_hgt@azm280 = 378 t_eff_hgt@azm290 = 380 t_eff_hgt@azm300 = 380 t_eff_hgt@azm310 = 378 t_eff_hgt@azm320 = 371 t_eff_hgt@azm330 = 376 t_eff_hgt@azm340 = 379 t_eff_hgt@azm350 = 388 </ANT_HGT> t_ant_dir = ND t_ref_plan_cfg = RPC1 t_sfn_id = VALGJ�RVE/44 t_spect_mask = N <COORD> t_adm = FIN t_adm = LVA t_adm = RUS t_adm = S </COORD> </NOTICE> <NOTICE> t_notice_type = TB5 t_fragment = GE06D t_action = SUPPRESS t_trg_adm_ref_id = EST-09-04-vlg </NOTICE> <TAIL> t_num_notices = 28 </TAIL> Bundesnetzagentur für Elektrizität , Gas, Telekommunikation , Post und Eisenbahnen [email protected] Your e-mail from 07.04.2016 Our 09.05.16 nr 18-5/ 16-0035-007 Regional Agreement Geneva, 2006 (GE06D) Dear Madam/Sir Thank you for the quick replay regarding the publication (BRIFIC 2812, GE06/114) of new Estonian allotments. Now the biggest problem for Estonia is the time pressure to clear the 700 MHz band from broadcasting and to find additional TV channels to compensate the 49-60 channels. We have the preliminary agreement from our neighbour administrations for the new channels, but no final agreements yet and no fixed target date. In total, we have seven TV channels missing below 700 MHz (one in ORISSAARE, three in PÄRNU, one in KOERU and two in VALGJÄRVE). From that seven channels four are not that important today (can be replaced later), but three are relevant now. Implementation of PÄRNU allotment is the most difficult, because today it has the most above 694 MHz channels that needs to be replaced. In accordance to the Article 4 of the Geneva 2006 Agreement Estonian Administration seeks for your approval the following digital terrestrial broadcasting assignments: PÄRNU channel 34 (ADD) PÄRNU channel 56 (SUP); PÄRNU channel 24 (ADD) PÄRNU channel 53 (SUP); PÄRNU channel 38 (ADD) PÄRNU channel 62 (SUP); PÄRNU channel 41 (ADD) PÄRNU channel 49 (SUP); PÄRNU channel 46 (ADD); ORISSAARE channel 24 (ADD) ORISSAARE channel 67 (SUP); ORISSAARE channel 26 (ADD) ORISSAARE channel 69 (SUP); TALLINN channel 34 (ADD) TALLINN channel 64 (SUP); TALLINN channel 59 (SUP); KOHTLA channel 35 (ADD) KOHTLA channel 58 (SUP); KOERU channel 47 (ADD) KOERU channel 57 (SUP); KOERU channel 25 (ADD) KOERU channel 60 (SUP); KOERU channel 63 (SUP); VALGJÄRVE channel 25 (ADD) VALGJÄRVE channel 52 (SUP); VALGJÄRVE channel 43 (ADD) VALGJÄRVE channel 55 (SUP); VALGJÄRVE channel 44 (ADD) VALGJÄRVE channel 61 (SUP); The complete technical characteristics of the above assignments in electronic format together with this cover letter have been sent to the e-mail address [email protected] with a copy to [email protected] . The changes have been introduced in order to clear the 700 MHz band for mobile broadband services in Estonia by the end of June 2017. We look forwar d receiving your prompt comments. Sincerely Alo Einla Head of Frequency Management Department Vladimir Jakovlev 667 2123 [email protected]
Allikas: Tarbijakaitse ja Tehnilise Järelevalve Amet dokumendiregister →